<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xml:lang="EN" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="editorial">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Cardiovasc. Med.</journal-id>
<journal-title>Frontiers in Cardiovascular Medicine</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Cardiovasc. Med.</abbrev-journal-title>
<issn pub-type="epub">2297-055X</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fcvm.2022.891914</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Cardiovascular Medicine</subject>
<subj-group>
<subject>Editorial</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Editorial: Current Devices in Mitral Valve Replacement and Their Potential Complications</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes">
<name><surname>Buzzatti</surname> <given-names>Nicola</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="corresp" rid="c001"><sup>&#x0002A;</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/658183/overview"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Taramasso</surname> <given-names>Maurizio</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Puri</surname> <given-names>Rishi</given-names></name>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/427665/overview"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Van Der Heyden</surname> <given-names>Jan</given-names></name>
<xref ref-type="aff" rid="aff4"><sup>4</sup></xref>
<uri xlink:href="http://loop.frontiersin.org/people/655188/overview"/>
</contrib>
</contrib-group>
<aff id="aff1"><sup>1</sup><institution>Department of Cardiac Surgery, San Raffaele Scientific Institute</institution>, <addr-line>Milan</addr-line>, <country>Italy</country></aff>
<aff id="aff2"><sup>2</sup><institution>Department of Cardiac Surgery, HerzZentrum Hirslanden Zurich</institution>, <addr-line>Zurich</addr-line>, <country>Switzerland</country></aff>
<aff id="aff3"><sup>3</sup><institution>Cliveland Clinic</institution>, <addr-line>Cleveland, OH</addr-line>, <country>United States</country></aff>
<aff id="aff4"><sup>4</sup><institution>AZ Sint-Jan Brugge &#x02013; Oostende AV</institution>, <addr-line>Brugge</addr-line>, <country>Belgium</country></aff>
<author-notes>
<fn fn-type="edited-by"><p>Edited and reviewed by: Michel R. Labrosse, University of Ottawa, Canada</p></fn>
<corresp id="c001">&#x0002A;Correspondence: Nicola Buzzatti <email>buzzatti.nicola&#x00040;hsr.it</email></corresp>
<fn fn-type="other" id="fn001"><p>This article was submitted to Structural Interventional Cardiology, a section of the journal Frontiers in Cardiovascular Medicine</p></fn></author-notes>
<pub-date pub-type="epub">
<day>26</day>
<month>04</month>
<year>2022</year>
</pub-date>
<pub-date pub-type="collection">
<year>2022</year>
</pub-date>
<volume>9</volume>
<elocation-id>891914</elocation-id>
<history>
<date date-type="received">
<day>08</day>
<month>03</month>
<year>2022</year>
</date>
<date date-type="accepted">
<day>30</day>
<month>03</month>
<year>2022</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#x000A9; 2022 Buzzatti, Taramasso, Puri and Van Der Heyden.</copyright-statement>
<copyright-year>2022</copyright-year>
<copyright-holder>Buzzatti, Taramasso, Puri and Van Der Heyden</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/"><p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p></license>
</permissions>
<related-article id="RA1" related-article-type="commentary-article" xlink:href="https://www.frontiersin.org/research-topics/9472/current-devices-in-mitral-valve-replacement-and-their-potential-complications" ext-link-type="uri">Editorial on the Research Topic <article-title>Current Devices in Mitral Valve Replacement and Their Potential Complications</article-title>
</related-article>
<kwd-group>
<kwd>mitral</kwd>
<kwd>replacement</kwd>
<kwd>transcatheter</kwd>
<kwd>repair</kwd>
<kwd>regurgitation</kwd>
</kwd-group>
<counts>
<fig-count count="0"/>
<table-count count="0"/>
<equation-count count="0"/>
<ref-count count="0"/>
<page-count count="2"/>
<word-count count="1072"/>
</counts>
</article-meta>
</front>
<body>
<p>When the first ever percutaneous mitral valve replacement was performed on a patient in 2012 it raised great enthusiasm as well as the expectations to follow swiftly the road already laid down by transcatheter aortic valve implantation, expanding rapidly to a wide patient population, and growing year after year to become soon a routine procedure. Several different devices have been developed over the past decade to fulfill these promises.</p>
<p>In reality, compared to the aortic valve, the mitral is indeed a much more complicated apparatus with specific clinical, anatomical, and technical challenges which soon became very clear, such as the big dimensions of the mitral valve, the difficult anchoring, the anatomical interference the surrounding structures and the functional interdependence with the left ventricle. Such challenges proved difficult to overcome and indeed, after 10 years, only a minority of highly selected patients have been treated with transcatheter mitral replacement worldwide.</p>
<p>The purpose of the present anthology is to present the devices currently available for transcatheter mitral replacement along with their positive outcomes as well as their potential complication and discuss the challenges the field is facing to progress further in the next future.</p>
<p><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3389/fcvm.2020.531843">Gheorghe et al.</ext-link> present a complete review of the most important devices developed, detailing the technical aspects which differentiate each one from the other, reporting their main outcomes as well as their possible complications. Some complications, such as the risk of left ventricle outflow tract obstruction are shared by all devices, while some others can be peculiar to each different replacement technology.</p>
<p>The transapical Tendyne valve is currently the only CE approved device for mitral replacement and indeed the one with the biggest experience in the clinical setting. Importantly this therapy can be applied not only to pure mitral regurgitation but also to selected cases of mixed regurgitation/stenosis as well as patients with severe mitral annular calcification, who represent one of the most challenging setting for both surgery and transcatheter devices. A focus on the Tendyne valve is provided by <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3389/fcvm.2020.592909">Dahle</ext-link>.</p>
<p>The blood flow around the mitral valve, slower than in the aorta, and the bulky design and fabrics of the transcatheter replacement devices make thrombosis a typical complication of such procedures during follow-up. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3389/fcvm.2021.621258">Ascione and Denti</ext-link> discuss with available data the reasons why transcather mitral prostheses carry a heavy thrombotic burden as well as recommendations to prevent and to treat protheses thrombosis.</p>
<p><ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3389/fcvm.2021.639058">Kargoli et al.</ext-link> provide further details on the different complications after transcatheter mitral valve replacement. The management of each complication is described. Advanced interventional techniques may be required in some peculiar extreme cases but a patient-tailored multidisciplinary Heart-Team approach is always the common base to deal with such complex situations and help prevent issues in the first place.</p>
<p>Surgical mitral repair, when appropriate, is always to be preferred to surgical replacement. While the role of transcatheter mitral replacement in comparison to transcatheter mitral repair remains to be determined, the current excellent results of transcatheter mitral repair, especially in terms of safety, further raise the quality bar that replacement needs to meet to be considered a valid alternative. Indeed percutaneous mitral repair, rather than surgery, is currently the first competitor of transcatheter mitral replacement. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3389/fcvm.2021.738756">Russo et al.</ext-link> discuss the repair vs. replacement dilemma while also elaborating on future developments and directions of replacement therapies.</p>
<p>Transcatheter mitral replacement is a precious option for patients who are not eligible for transcatheter mitral repair nor conventional surgery. Unfortunately its adoption is currently still bound to specific anatomies and technological limitations. Such challenges will require time to be fully overcome and indeed we are just still facing the early phase of the field but significant new mitral knowledge has already been acquired over the past decade thanks to transcatheter mitral replacement that will be the ground for future further improvements and developments. The road ahead is still long and it is not straightforward but the goal remains to allow more patients to be able to benefit from a safe and effective percutaneous mitral treatment, and it is well worth it.</p>
<sec id="s1">
<title>Author Contributions</title>
<p>All authors listed have made a substantial, direct, and intellectual contribution to the work and approved it for publication.</p>
</sec>
<sec sec-type="COI-statement" id="conf1">
<title>Conflict of Interest</title>
<p>JV was employed by AZ Sint-Jan Brugge &#x02013; Oostende AV, Brugge, Belgium. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec sec-type="disclaimer" id="s2">
<title>Publisher&#x00027;s Note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
</body>
</article>