<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Built Environ.</journal-id>
<journal-title>Frontiers in Built Environment</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Built Environ.</abbrev-journal-title>
<issn pub-type="epub">2297-3362</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3389/fbuil.2017.00053</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Built Environment</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Spatial&#x02013;Temporal Analysis of the Heat and Electricity Demand of the Swiss Building Stock</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes">
<name><surname>Schneider</surname> <given-names>Stefan</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<xref ref-type="corresp" rid="cor1">&#x0002A;</xref>
<uri xlink:href="http://frontiersin.org/people/u/411392"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Hollmuller</surname> <given-names>Pierre</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Le Strat</surname> <given-names>Pascale</given-names></name>
<xref ref-type="aff" rid="aff2"><sup>2</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Khoury</surname> <given-names>Jad</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
<uri xlink:href="http://frontiersin.org/people/u/485078"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Patel</surname> <given-names>Martin</given-names></name>
<xref ref-type="aff" rid="aff3"><sup>3</sup></xref>
<uri xlink:href="http://frontiersin.org/people/u/132093"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Lachal</surname> <given-names>Bernard</given-names></name>
<xref ref-type="aff" rid="aff1"><sup>1</sup></xref>
</contrib>
</contrib-group>
<aff id="aff1"><sup>1</sup><institution>Energy System Group, Institute for Environmental Sciences (ISE), Department F.-A. Forel for Environmental and Aquatic Sciences (DEFSE), University of Geneva</institution>, <addr-line>Geneva</addr-line>, <country>Switzerland</country></aff>
<aff id="aff2"><sup>2</sup><institution>Services industriels de Gen&#x000E8;ve</institution>, <addr-line>Le Lignon</addr-line>, <country>Switzerland</country></aff>
<aff id="aff3"><sup>3</sup><institution>Faculty of Science, Department F.-A. Forel for Environmental and Aquatic Sciences (DEFSE), Institute for Environmental Sciences (ISE), University of Geneva</institution>, <addr-line>Geneva</addr-line>, <country>Switzerland</country></aff>
<author-notes>
<fn fn-type="edited-by"><p>Edited by: Nahid Mohajeri, &#x000C9;cole Polytechnique F&#x000E9;d&#x000E9;rale de Lausanne, Switzerland</p></fn>
<fn fn-type="edited-by"><p>Reviewed by: Changyoon Ji, Yonsei University, South Korea; Rokia Raslan, University College London, United Kingdom</p></fn>
<corresp content-type="corresp" id="cor1">&#x0002A;Correspondence: Stefan Schneider, <email>stefan.schneider&#x00040;unige.ch</email></corresp>
<fn fn-type="other" id="fn001"><p>Specialty section: This article was submitted to Sustainable Design and Construction, a section of the journal Frontiers in Built Environment</p></fn>
</author-notes>
<pub-date pub-type="epub">
<day>25</day>
<month>08</month>
<year>2017</year>
</pub-date>
<pub-date pub-type="collection">
<year>2017</year>
</pub-date>
<volume>3</volume>
<elocation-id>53</elocation-id>
<history>
<date date-type="received">
<day>31</day>
<month>05</month>
<year>2017</year>
</date>
<date date-type="accepted">
<day>08</day>
<month>08</month>
<year>2017</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#x000A9; 2017 Schneider, Hollmuller, Le Strat, Khoury, Patel and Lachal.</copyright-statement>
<copyright-year>2017</copyright-year>
<copyright-holder>Schneider, Hollmuller, Le Strat, Khoury, Patel and Lachal</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/"><p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p></license>
</permissions>
<abstract>
<p>In 2015, space heating and domestic hot water production accounted for around 40% of the Swiss final energy consumption. Reaching the goals of the 2050 energy strategy will require significantly reducing this share despite the growing building stock. Renewables are numerous but subject to spatial&#x02013;temporal constraints. Territorial planning of energy distribution systems enabling the integration of renewables requires having a spatial&#x02013;temporal characterization of the energy demand. This paper presents two bottom-up statistical extrapolation models for the estimation of the geo-dependent heat and electricity demand of the Swiss building stock. The heat demand is estimated by means of a statistical bottom-up model applied at the building level. At the municipality level, the electricity load curve is estimated by combining socio-economic indicators with average consumption per activity and/or electric device. This approach also allows to break down the estimated electricity demand according to activity type (e.g., households, various industry, and service activities) and appliance type (e.g., lighting, motor force, fridges). The total estimated aggregated demand is 94&#x02009;TWh for heat and 58&#x02009;TWh for electricity, which represent a deviation of 2.9 and 0.5%, respectively compared to the national energy consumption statistics. In addition, comparisons between estimated and measured electric load curves are done to validate the proposed approach. Finally, these models are used to build a geo-referred database of heat and electricity demand for the entire Swiss territory. As an application of the heat demand model, a realistic saving potential is estimated for the existing building stock; this potential could be achieved through by a deep retrofit program. One advantage of the statistical bottom-up model approach is that it allows to simulate a building stock that replicates the diversity of building demand. This point is important in order to correctly account for the mismatch between gross and net energy saving potential, often called performance gap. The impact of this performance gap is substantial since the estimated net saving potential is only half of the gross one.</p>
</abstract>
<kwd-group>
<kwd>geo-depended energy demand</kwd>
<kwd>energy consumption by use</kwd>
<kwd>building classification</kwd>
<kwd>electric load curve</kwd>
<kwd>bottom-up model</kwd>
</kwd-group>
<contract-num rid="cn01">KTI.2014.0119</contract-num>
<contract-sponsor id="cn01">Kommission f&#x000FC;r Technologie und Innovation<named-content content-type="fundref-id">10.13039/501100001808</named-content></contract-sponsor>
<counts>
<fig-count count="12"/>
<table-count count="3"/>
<equation-count count="16"/>
<ref-count count="44"/>
<page-count count="17"/>
<word-count count="11926"/>
</counts>
</article-meta>
</front>
<body>
<sec id="S1" sec-type="introduction">
<title>Introduction</title>
<p>The global energy statistic report (BFE, <xref ref-type="bibr" rid="B5">2016</xref>) and the sectorial energy consumption analysis of Kemmler et al. (<xref ref-type="bibr" rid="B17">2014</xref>) show that around 40% of the Swiss final energy consumption is used for space heating (SH) and domestic hot water (DHW) production. Adding the energy consumed by other building services to heat demand, shows that around half of the total final energy consumption can be attributed to the building sector. For this reason, the 2050 Swiss Energy Strategy targets to reduce the demand of the Swiss building stock by 63%, while increasing the share of renewable energy (Kirchner et al., <xref ref-type="bibr" rid="B20">2012</xref>). The 2050 Swiss Energy Strategy has ambitious CO<sub>2</sub> emission reduction targets as well. Replacing fossil energy resources by electricity will raise questions on how to satisfy the increasing electricity demand (58&#x02009;TWh in 2015).</p>
<p>Using Kaya&#x02019;s identity, Mavromatidis et al. (<xref ref-type="bibr" rid="B24">2016</xref>) emphasize that reaching these targets will require to work along two axes: energy efficiency to reduce energy demand and substitution of fossil resources by renewables to reduce emissions per produced energy unit. A precondition to design strategies allowing to progress along these two axes is to have a better knowledge of the territorial energy demand. Territorial aspects related to heat and electricity consumption are a main concern of major EU research projects, such as Connolly et al. (<xref ref-type="bibr" rid="B8">2013</xref>), Persson et al. (<xref ref-type="bibr" rid="B30">2014</xref>), and David et al. (<xref ref-type="bibr" rid="B9">2017</xref>). The territorial aspect of heat demand is predominant, since heat is difficult and expensive to transport over long distances. Renewable heat resources are numerous but often linked to spatial&#x02013;temporal constraints. For example, the use of high enthalpy geothermal and/or waste heat requires the development of district heating networks. At the Swiss national level, the potential use of these resources is studied by the SCCER FEEB&#x00026;D (<xref ref-type="bibr" rid="B33">2017</xref>) project hosted by the Swiss Center of Competence in Energy Research (SCCER). The project is based on a spatial&#x02013;temporal characterization of energy demand and renewable energy supply; one of its tasks is to design optimal decentralized energy systems that are able to match both the demand and supply side.</p>
<p>The characterization of heat and electricity consumption is also an important topic to better understand the effectiveness of energy efficiency programs. Heat demand reduction can be achieved, for example, by retrofitting the building envelope, using ventilation with heat recovery and improved building control systems. The effect of the performance gap, defined as the discrepancy between the expected and real savings achieved by building retrofit, was quantified by Khoury (<xref ref-type="bibr" rid="B18">2014</xref>) the for post-war multi-family residential buildings of the Canton of Geneva. How this gap impacts the projected heat demand reduction of the entire Swiss building stock is estimated in Section &#x0201C;<xref ref-type="sec" rid="S3-8">Impact of Large-scale Retrofit on Heat Demand</xref>.&#x0201D; The design of programs that target the reduction of electricity demand is more complex because of the different possible uses of electricity. Detailed knowledge of how the electricity demand of a territory breaks down into various activities and electric appliances is a precondition for such a program. This is illustrated by Le Strat&#x02019;s (Le Strat, <xref ref-type="bibr" rid="B21">2008</xref>) study giving a detailed analysis of how electric consumption has evolved in the Canton of Geneva. In 2009, this study was used to redesign the large-scale electricity savings program ECO21 launched by the energy service company SIG. This knowledge allows, for example, to make <italic>ex ante</italic> estimations of savings achievable by large-scale electric device replacement, such as efficient lighting in the common areas of residential buildings. Expected versus actual savings for two ECO21 subprograms were compared (Cabrera et al., <xref ref-type="bibr" rid="B6">2012</xref>) using three different approaches.</p>
<p>Geographical information systems (GIS) have gained major importance thanks to the increasing computing power and data storage capacities combined with big data analysis techniques. The use of GIS databases to assess energy demand and renewable resources is relevant at several territorial scales. Studies at the regional scale use building level demand as input for their models, as, for example, Saner et al. (<xref ref-type="bibr" rid="B32">2014</xref>) and Orehounig et al. (<xref ref-type="bibr" rid="B28">2014</xref>). The potential of combining thermal and PV solar panels is assessed for one urban and one suburban district by Quiquerez et al. (<xref ref-type="bibr" rid="B31">2015</xref>) using a GIS analysis. At the Swiss national scale Eicher et al. (<xref ref-type="bibr" rid="B14">2014</xref>) use GIS demand models aggregated on a hectare raster. At a much bigger scale, such as the European Union, Connolly et al. (<xref ref-type="bibr" rid="B8">2013</xref>) or Persson et al. (<xref ref-type="bibr" rid="B30">2014</xref>) use a 1-km<sup>2</sup> raster grid.</p>
<p>This paper presents two geo-dependent energy demand models, the first deals with final energy demand for SH and DHW production and the second one concerns electricity demand. The two following subsections give specific background information for these two models.</p>
<sec id="S1-1">
<title>Geo-Dependent Heat Demand</title>
<p>The review paper of Swan and Ugursal (<xref ref-type="bibr" rid="B43">2009</xref>) outlines a clear classification of available models that estimate heat demand of buildings. Bottom-up models have the advantage that they estimate the energy demand of small consumer aggregates, as for example buildings that can be linked to geographical coordinates. To estimate the energy demand at the building level, the two main alternatives are to use either engineering or statistical models.</p>
<p>Engineering models are based on building physics and require detailed information on the building geometry as well as the envelope components and their associated <italic>U</italic> and <italic>g</italic> values. At the national scale such detailed data are not available and default values for many parameters must be used (Perez et al., <xref ref-type="bibr" rid="B29">2011</xref>) when simulating the heat demand of a large building stock. Choosing this approach implies that buildings of same type have the same losses by conduction through the building envelope. Energy demand, therefore, only depends on local climate conditions and solar gains.</p>
<p>Statistical models encapsulate the complex set of building characteristics that explain the energy demand in a smaller set of parameters. Regression models estimate these parameters using calibration samples of buildings with known energy consumption. Another advantage of basing the model on measured energy demand is that it includes the influence of the users (inhabitants and facility manager). This influence often leads to a difference between calculated and actual consumption even in cases where the characteristics of the building are known in detail (De Wilde, <xref ref-type="bibr" rid="B10">2014</xref>).</p>
<p>These reasons motivate the choice of a statistical extrapolation method based on measured final energy consumption; such a method accounts for the behavior of the user and the variability of demand between buildings with similar characteristics. A representative sample of around 27,000 buildings containing measured final energy for SH and DHW is used to calibrate the model.</p>
</sec>
<sec id="S1-2">
<title>Geo-Dependent Electricity Demand</title>
<p>There are numerous methods to simulate load curves. The review paper of Grandjean et al. (<xref ref-type="bibr" rid="B15">2012</xref>) classifies the most relevant algorithms into five groups, including both random (replicating the diversity of consecutive days) and deterministic models (replicating average behavior). For example, high-resolution models, such as Marszal-Pomianowska et al. (<xref ref-type="bibr" rid="B23">2016</xref>), seek to include the stochastic variability of electricity demand related to the behavior of the inhabitants. At the Swiss national level, the goal is rather to provide a large-scale model based on the average behavior of users and their related activities. The proposed approach is closer to that of the FORECAST/eLOAD model (Jakob et al., <xref ref-type="bibr" rid="B16">2014</xref>). The primary target is to offer the Swiss municipalities a tool allowing to identify electricity saving potential and to predesign an ECO21 type program. The key question is how the electric demand of a municipality is divided into the various activities and electric appliances.</p>
<p>The model presented in Section &#x0201C;<xref ref-type="sec" rid="S2-4">Geo-Dependent Electricity Demand</xref>&#x0201D; is the result of a collaboration between the academic research project SCCER FEEB&#x00026;D (<xref ref-type="bibr" rid="B33">2017</xref>) and the local utility SIG. The basis for this model is a study of Le Strat (<xref ref-type="bibr" rid="B22">2011</xref>) that characterizes the electric consumption of a territory including all the energy service companies (ESCO) of the EOS holding group. This model decomposes the electricity demand into 36 activities and 18 groups of electric appliances. The planned outcome of this collaboration is the <italic>ElectroWhat</italic> web platform, which seeks to answer the question &#x0201C;who consumes where, when and for what use&#x0201D; at the national level. Throughout this paper, the term <italic>ElectroWhat</italic> often also refers to the geo-dependent electricity demand model.</p>
<p>Finally, the resulting GIS data of both models is stored in a database developed in collaboration with EPFL in Lausanne, also containing the renewable PV rooftop potential (Assouline et al., <xref ref-type="bibr" rid="B1">2015</xref>) and low enthalpy geothermal potential (in preparation). Such a database offers the opportunity to perform many territorial studies at the Swiss national level.</p>
</sec>
</sec>
<sec id="S2" sec-type="methods">
<title>Methods</title>
<p>This section describes the methods used to make a geo-dependent characterization of heat and electricity demand. These two demands are linked for buildings that are heated using electricity. In this case, we first start to estimate the final energy demand for SH and DHW using the heat demand model. For each municipality we use the fraction of dwellings that are equipped with electric heat production systems. For this fraction, the heat demand is then converted into electricity using efficiency factors that depend on the heat production system (resistance electric heating or heat pump). The yearly demand estimations are then divided in monthly demands using ratios of monthly degree day (DD) over yearly DD.</p>
<sec id="S2-3">
<title>Geo-Dependent Heat Demand</title>
<p>The chosen approach, presented in this section, is a statistical regression bottom-up model (Schneider et al., <xref ref-type="bibr" rid="B35">2016</xref>). It is based on measured heat demand and heated surfaces values of a representative set of around 27,000 buildings. It estimates the heat demand per square meter of each building of the Swiss national building register as a function of its category, age, and location, and its heated surface as a function of the category, gross surface, and/or dwelling surface. A bootstrap resampling algorithm quantifies the uncertainty inherent to the use of average demand values per age and category. This model improves previous work done by Eicher et al. (<xref ref-type="bibr" rid="B13">2011</xref>). Figure <xref ref-type="fig" rid="F1">1</xref> outlines the general structure of the model. The heated surface <italic>A<sub>E</sub></italic> (square meter) and the floor specific heat demand <italic>E</italic> (MJ/m<sup>2</sup>/year) are estimated combining basic information provided by the Swiss building register (OFS, <xref ref-type="bibr" rid="B26">2014a</xref>) with average statistics calculated using calibration sets. The estimations of the heated surface <italic>A<sub>E</sub></italic> and floor specific heat demand <italic>E</italic> are done separately, since they allow to take account of regional climate conditions that may vary a lot depending on geographical position. We assume that only <italic>E</italic> depends on climatic conditions, whereas the relation between <italic>A<sub>E</sub></italic> and gross building surface (<italic>A</italic><sub>gross</sub>) and/or dwelling surface (<italic>A</italic><sub>dwelling</sub>) do not. The final energy demand SE<italic><sub>B</sub></italic> (MJ/year) of a building is obtained by multiplying these two estimations.</p>
<fig position="float" id="F1">
<label>Figure 1</label>
<caption><p>Heat demand model overview.</p></caption>
<graphic xlink:href="fbuil-03-00053-g001.tif"/>
</fig>
<p>Finally, for each pixel of territory, the estimated heat demand is summed over all buildings and a bootstrap algorithm allows to compute a confidence interval around the estimated value given by the model.</p>
<sec id="S2-3-1">
<title>Datasets</title>
<p>The model uses the following datasets:
<list list-type="simple">
<list-item><label>(i)</label> <p>The Swiss national building register (GWR) maintained by the Swiss Federal Statistical Office (OFS, <xref ref-type="bibr" rid="B26">2014a</xref>) that contains basic building information such as: geographical coordinates, category, age, ground, and dwelling surface as well as the main energy carrier for approximately two million buildings. This database is not exhaustive for non-residential buildings. A comparison with the Swiss building footprint data layer (Swiss Topo, <xref ref-type="bibr" rid="B44">2015</xref>) shows that around 400,000 buildings are missing. A unique federal building identification number (EGID) identifies each building, which allows to link these data with other databases. Basic building information data, such as building category, construction period, <italic>A</italic><sub>gross</sub>, <italic>A</italic><sub>dwelling</sub>, geographical coordinates, and main energy carrier are extracted from this dataset.</p></list-item>
<list-item><label>(ii)</label> <p>The Geneva SITG IDC database contains measured energy consumption as well as heated surface <italic>A<sub>E</sub></italic> defined according to the SIA 416/1 standard for residential multi-family buildings and buildings used for non-residential purpose. This declaration is mandatory and is updated each year by a network of trained agents. This database (SITG, <xref ref-type="bibr" rid="B42">2015</xref>) contains around 16,000 buildings, out of a total of approximately 48,000 buildings for the Canton of Geneva.</p></list-item>
<list-item><label>(iii)</label> <p>The GEAK database contains the energy consumption for SH and DHW averaged over 3&#x02009;years. The database contains 11,500 buildings (approximately 0.5% of the Swiss building stock) spread over the entire Swiss territory.</p></list-item>
<list-item><label>(iv)</label> <p>The SIA 2028 standard (SIA, <xref ref-type="bibr" rid="B39">2010</xref>) contains DD for 40 meteorological stations. Figure <xref ref-type="fig" rid="F2">2</xref> displays the fit of a linear regression between the DD, altitude and latitude in CH_LV03 coordinates. Each dot of the scatterplot represents the estimated versus measured DD of a meteorological station. This linear fit will be used at later stage to estimate the DD for each building of the GWR using its altitude and geographical coordinates. The <italic>R</italic><sup>2</sup> is 0.95, the maximum observed relative difference is 14% and the average difference is 4%.</p></list-item>
</list></p>
<fig position="float" id="F2">
<label>Figure 2</label>
<caption><p>Model degree day <italic>DD</italic> versus SIA 2028 <italic>DD</italic> for all Swiss meteorological stations.</p></caption>
<graphic xlink:href="fbuil-03-00053-g002.tif"/>
</fig>
</sec>
<sec id="S2-3-2">
<title>Estimation of Heated Surface <italic>A<sub>E</sub></italic></title>
<p>Cross-matching the SITG IDC and GWR databases allows to study the relations between building category, gross surface, dwelling surface, and actual heated surface indicated in the SITG IDC database. Figure <xref ref-type="fig" rid="F3">3</xref> shows such a linear regression for the multi-family residential buildings. The buildings with known heated surface <italic>A<sub>E</sub></italic> of the SITG IDC database are divided into four main categories and ten sub-categories based on a classification that divides the sample into groups with significant differences for the ratio <italic>A<sub>E</sub></italic>/<italic>A</italic><sub>gross</sub>. Table <xref ref-type="table" rid="T1">1</xref> gives the regression coefficients obtained from ten different building categories, given by 8,951 observations from the SITG IDC database. These regression coefficients allow to estimate for each building of the GWR database, the heated surface <italic>A<sub>E</sub></italic> by means of the gross surface (number of floors x ground surface) and/or the dwelling surface. If both estimations are possible, priority is given to the estimation based on gross surface because the coefficient of determination <italic>R<sup>2</sup></italic> of the linear regression is higher.</p>
<fig position="float" id="F3">
<label>Figure 3</label>
<caption><p>Heated floor area <italic>A<sub>E</sub></italic> as a function of gross surface <italic>A</italic><sub>gross</sub> and <italic>A</italic><sub>dwelling</sub> for multi-family buildings.</p></caption>
<graphic xlink:href="fbuil-03-00053-g003.tif"/>
</fig>
<table-wrap position="float" id="T1">
<label>Table 1</label>
<caption><p>Regression coefficients between heated floor surface and gross surface (<italic>f</italic><sub>gross</sub>) and between heated floor surface and dwelling surface (<italic>f</italic><sub>dwell</sub>), as observed in the IDC database.</p></caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th valign="top" align="left">Category</th>
<th valign="top" align="left">Subcategory</th>
<th valign="top" align="center"><italic>f</italic><sub>gross</sub></th>
<th valign="top" align="center"><italic>R</italic><sup>2</sup></th>
<th valign="top" align="center"><italic>N</italic></th>
<th valign="top" align="center"><italic>f</italic><sub>dwell</sub></th>
<th valign="top" align="center"><italic>R</italic><sup>2</sup></th>
<th valign="top" align="center"><italic>N</italic></th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left">MF residential</td>
<td valign="top" align="left">Only residential</td>
<td valign="top" align="center">0.890</td>
<td valign="top" align="center">0.973</td>
<td valign="top" align="center">5,103</td>
<td valign="top" align="center">1.275</td>
<td valign="top" align="center">0.952</td>
<td valign="top" align="center">4,591</td>
</tr>
<tr>
<td valign="top" align="left"/>
<td valign="top" align="left">With annex use</td>
<td valign="top" align="center">0.845</td>
<td valign="top" align="center">0.962</td>
<td valign="top" align="center">2,639</td>
<td valign="top" align="center">1.406</td>
<td valign="top" align="center">0.889</td>
<td valign="top" align="center">2,350</td>
</tr>
<tr>
<td valign="top" align="left">SF residential</td>
<td valign="top" align="left">Only res. or with annex use</td>
<td valign="top" align="center">0.732</td>
<td valign="top" align="center">0.936</td>
<td valign="top" align="center">462</td>
<td valign="top" align="center">1.398</td>
<td valign="top" align="center">0.963</td>
<td valign="top" align="center">313</td>
</tr>
<tr>
<td valign="top" align="left">Non-residential</td>
<td valign="top" align="left">Office and commercial<xref ref-type="table-fn" rid="tfnT1_1"><sup>a</sup></xref></td>
<td valign="top" align="center">0.787</td>
<td valign="top" align="center">0.917</td>
<td valign="top" align="center">282</td>
<td valign="top" align="center"/>
<td valign="top" align="center"/>
<td valign="top" align="center"/>
</tr>
<tr>
<td valign="top" align="left"/>
<td valign="top" align="left">Agricultural and industrial<xref ref-type="table-fn" rid="tfnT1_2"><sup>b</sup></xref></td>
<td valign="top" align="center">0.681</td>
<td valign="top" align="center">0.920</td>
<td valign="top" align="center">134</td>
<td valign="top" align="center"/>
<td valign="top" align="center"/>
<td valign="top" align="center"/>
</tr>
<tr>
<td valign="top" align="left"/>
<td valign="top" align="left">Others</td>
<td valign="top" align="center">0.702</td>
<td valign="top" align="center">0.921</td>
<td valign="top" align="center">29</td>
<td valign="top" align="center"/>
<td valign="top" align="center"/>
<td valign="top" align="center"/>
</tr>
<tr>
<td valign="top" align="left">Mixed use</td>
<td valign="top" align="left">Office and commercial<xref ref-type="table-fn" rid="tfnT1_1"><sup>a</sup></xref></td>
<td valign="top" align="center">0.636</td>
<td valign="top" align="center">0.894</td>
<td valign="top" align="center">313</td>
<td valign="top" align="center">1.847</td>
<td valign="top" align="center">0.189</td>
<td valign="top" align="center">161</td>
</tr>
<tr>
<td valign="top" align="left"/>
<td valign="top" align="left">Agricultural and industrial<xref ref-type="table-fn" rid="tfnT1_2"><sup>b</sup></xref></td>
<td valign="top" align="center">0.664</td>
<td valign="top" align="center">0.906</td>
<td valign="top" align="center">31</td>
<td valign="top" align="center">12.428</td>
<td valign="top" align="center">0.553</td>
<td valign="top" align="center">27</td>
</tr>
<tr>
<td valign="top" align="left"/>
<td valign="top" align="left">Others</td>
<td valign="top" align="center">0.631</td>
<td valign="top" align="center">0.889</td>
<td valign="top" align="center">57</td>
<td valign="top" align="center">2.337</td>
<td valign="top" align="center">0.232</td>
<td valign="top" align="center">42</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn id="tfnT1_1"><p><italic><sup>a</sup>Includes hotels, schools, and hospitals</italic>.</p></fn>
<fn id="tfnT1_2"><p><italic><sup>b</sup>Includes depositories, garages, and museums</italic>.</p></fn>
<p><italic>R<sup>2</sup>, coefficient of determination of the linear regression; N, number of buildings</italic>.</p>
</table-wrap-foot>
</table-wrap>
<p>Finally, for each building of the IDC database and for both linear regressions, we compute the relative error &#x00394;<italic>A<sub>E</sub></italic> (%) between the actual and the estimated heated surface using
<disp-formula id="E1"><label>(1)</label><mml:math id="M1"><mml:mn>&#x00394;</mml:mn><mml:msub><mml:mrow><mml:mi>A</mml:mi></mml:mrow><mml:mrow><mml:mi>E</mml:mi></mml:mrow></mml:msub><mml:mo class="MathClass-rel">&#x0003D;</mml:mo><mml:mfrac><mml:mrow><mml:msub><mml:mrow><mml:mi>A</mml:mi></mml:mrow><mml:mrow><mml:mi>E</mml:mi></mml:mrow></mml:msub><mml:mo class="MathClass-bin">&#x02212;</mml:mo><mml:msub><mml:mrow><mml:mi>f</mml:mi></mml:mrow><mml:mrow><mml:mtext>gross</mml:mtext></mml:mrow></mml:msub><mml:mo class="MathClass-bin">&#x022C5;</mml:mo><mml:msub><mml:mrow><mml:mi>A</mml:mi></mml:mrow><mml:mrow><mml:mtext>gross</mml:mtext></mml:mrow></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mrow><mml:mi>f</mml:mi></mml:mrow><mml:mrow><mml:mtext>gross</mml:mtext></mml:mrow></mml:msub><mml:mo class="MathClass-bin">&#x022C5;</mml:mo><mml:msub><mml:mrow><mml:mi>A</mml:mi></mml:mrow><mml:mrow><mml:mtext>gross</mml:mtext></mml:mrow></mml:msub></mml:mrow></mml:mfrac><mml:mo class="MathClass-punc">,</mml:mo></mml:math></disp-formula>
<disp-formula id="E2"><label>(2)</label><mml:math id="M2"><mml:mn>&#x00394;</mml:mn><mml:msub><mml:mrow><mml:mi>A</mml:mi></mml:mrow><mml:mrow><mml:mi>E</mml:mi></mml:mrow></mml:msub><mml:mo class="MathClass-rel">&#x0003D;</mml:mo><mml:mfrac><mml:mrow><mml:msub><mml:mrow><mml:mi>A</mml:mi></mml:mrow><mml:mrow><mml:mi>E</mml:mi></mml:mrow></mml:msub><mml:mo class="MathClass-bin">&#x02212;</mml:mo><mml:msub><mml:mrow><mml:mi>f</mml:mi></mml:mrow><mml:mrow><mml:mtext>dwell</mml:mtext></mml:mrow></mml:msub><mml:mo class="MathClass-bin">&#x022C5;</mml:mo><mml:msub><mml:mrow><mml:mi>A</mml:mi></mml:mrow><mml:mrow><mml:mtext>dwelling</mml:mtext></mml:mrow></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mrow><mml:mi>f</mml:mi></mml:mrow><mml:mrow><mml:mtext>dwell</mml:mtext></mml:mrow></mml:msub><mml:mo class="MathClass-bin">&#x022C5;</mml:mo><mml:msub><mml:mrow><mml:mi>A</mml:mi></mml:mrow><mml:mrow><mml:mtext>dwelling</mml:mtext></mml:mrow></mml:msub></mml:mrow></mml:mfrac><mml:mo class="MathClass-punc">.</mml:mo></mml:math></disp-formula></p>
<p>These values, which are stored per building subcategory, will be used further down in Eq. <xref ref-type="disp-formula" rid="E10">10</xref> for the calculation of confidence intervals.</p>
<p>Note that the GEAK database, which is anonymous, could not be linked to the gross and dwelling surfaces of the GWR, reason why it is not used in this part of the calculation.</p>
</sec>
<sec id="S2-3-3">
<title>Heat Demand Estimation</title>
<p>For each building of the GWR database, the specific final energy for the heat demand <italic>SE<sub>B</sub></italic> is estimated by means of its age and category, using average values given by the SITG IDC and GEAK datasets, which are normalized to a common climatic reference. Due to its geographical specificities, Switzerland has important climatic differences between regions that depend mainly on altitude variations. To take this into account, a climatic correction is done to adapt the heat demand of a building to the local climatic conditions it is subject to.</p>
<sec id="S2-3-3-1">
<title>Normalization of Calibration Data to a Common Reference</title>
<p>Since the heat demand data of the GEAK and SITG IDC calibration sets concern a variety of energy carriers and locations, it must first be normalized to a common reference. Therefore, for each building of these datasets, the measured final energy demand <italic>E</italic> (MJ/m<sup>2</sup> year) is converted into useful heat demand for SH using the relation
<disp-formula id="E3"><label>(3)</label><mml:math id="M3"><mml:msub><mml:mrow><mml:mi>Q</mml:mi></mml:mrow><mml:mrow><mml:mtext>SH</mml:mtext></mml:mrow></mml:msub><mml:mo class="MathClass-rel">&#x0003D;</mml:mo><mml:msub><mml:mrow><mml:mn>&#x003B7;</mml:mn></mml:mrow><mml:mrow><mml:mtext>EC</mml:mtext></mml:mrow></mml:msub><mml:mi>E</mml:mi><mml:mo class="MathClass-bin">&#x02212;</mml:mo><mml:msub><mml:mrow><mml:mi>Q</mml:mi></mml:mrow><mml:mrow><mml:mtext>DHW</mml:mtext></mml:mrow></mml:msub><mml:mo class="MathClass-punc">,</mml:mo></mml:math></disp-formula></p>
<p>&#x003B7;<sub>EC</sub> (depending on energy carrier) is the transformation efficiency factor estimated by Khoury (<xref ref-type="bibr" rid="B18">2014</xref>) and <italic>Q</italic><sub>DHW</sub> the useful heat demand for DHW according to the SIA 380/1 norm. For buildings with thermal solar panels, <italic>Q</italic><sub>DHW</sub> only accounts for the fraction of the DHW demand which is produced by the main heat production system. In such a case, using <inline-formula><mml:math id="M4"><mml:msubsup><mml:mrow><mml:mi>Q</mml:mi></mml:mrow><mml:mrow><mml:mtext>DHW</mml:mtext></mml:mrow><mml:mrow><mml:mtext>SIA</mml:mtext></mml:mrow></mml:msubsup></mml:math></inline-formula> in Eq. <xref ref-type="disp-formula" rid="E3">3</xref> would lead to overestimating <italic>Q</italic><sub>DHW</sub> and underestimating <italic>Q</italic><sub>SH</sub>. To avoid underestimated <italic>Q</italic><sub>SH</sub> values the following constraint is added, which implies that at least one third of the total produced heat is used for SH
<disp-formula id="E4"><label>(4)</label><mml:math id="M5"><mml:msub><mml:mrow><mml:mi>Q</mml:mi></mml:mrow><mml:mrow><mml:mtext>DHW</mml:mtext></mml:mrow></mml:msub><mml:mo class="MathClass-rel">&#x0003D;</mml:mo><mml:mi mathvariant="normal">min</mml:mi><mml:mspace width="0.3em" class="thinspace"/><mml:mfenced separators="" open="(" close=")"><mml:mrow><mml:msubsup><mml:mrow><mml:mi>Q</mml:mi></mml:mrow><mml:mrow><mml:mtext>DHW</mml:mtext></mml:mrow><mml:mrow><mml:mtext>SIA</mml:mtext></mml:mrow></mml:msubsup><mml:mo class="MathClass-punc">,</mml:mo><mml:mn>2</mml:mn><mml:mo class="MathClass-bin">/</mml:mo><mml:mn>3</mml:mn><mml:msub><mml:mrow><mml:mn>&#x003B7;</mml:mn></mml:mrow><mml:mrow><mml:mtext>EC</mml:mtext></mml:mrow></mml:msub><mml:mi>E</mml:mi></mml:mrow></mml:mfenced><mml:mo class="MathClass-punc">.</mml:mo></mml:math></disp-formula></p>
<p>This thumb rule sets an upper limit for the ratio between <italic>Q</italic><sub>DHW</sub> and <italic>Q</italic><sub>SH</sub> that corresponds to very efficient buildings. This limit is based on observations made in buildings with high energy standards for which the energy required for DHW can be higher than the one for SH. Note that this choice will have limited influence on the final result since it only impacts the fraction <italic>Q</italic><sub>SH</sub> of <italic>E</italic> that is subject to the climatic correction of Eq. <xref ref-type="disp-formula" rid="E5">5</xref> and only concerns a small fraction of buildings. The impact of this thumb rule was evaluated by looking at the difference between <inline-formula><mml:math id="M6"><mml:mover accent="false" class="mml-overline"><mml:mrow><mml:msubsup><mml:mrow><mml:mi>Q</mml:mi></mml:mrow><mml:mrow><mml:mtext>SH</mml:mtext></mml:mrow><mml:mrow><mml:mtext>GE</mml:mtext></mml:mrow></mml:msubsup></mml:mrow><mml:mo accent="true">&#x000AF;</mml:mo></mml:mover></mml:math></inline-formula> (see Eq. <xref ref-type="disp-formula" rid="E7">7</xref>) calculated with the constraint (4) and <inline-formula><mml:math id="M7"><mml:mover accent="false" class="mml-overline"><mml:mrow><mml:msubsup><mml:mrow><mml:mi>Q</mml:mi></mml:mrow><mml:mrow><mml:mtext>SH</mml:mtext></mml:mrow><mml:mrow><mml:mtext>GE</mml:mtext></mml:mrow></mml:msubsup></mml:mrow><mml:mo accent="true">&#x000AF;</mml:mo></mml:mover></mml:math></inline-formula> calculated without. All absolute differences are below 2% and the average difference is 0.2% considering all categories and construction periods.</p>
<p>The useful energy demand values for SH are further normalized for each building to a common climatic reference (arbitrarily Geneva) using
<disp-formula id="E5"><label>(5)</label><mml:math id="M8"><mml:msubsup><mml:mrow><mml:mi>Q</mml:mi></mml:mrow><mml:mrow><mml:mtext>SH</mml:mtext></mml:mrow><mml:mrow><mml:mtext>GE</mml:mtext></mml:mrow></mml:msubsup><mml:mo class="MathClass-rel">&#x0003D;</mml:mo><mml:msub><mml:mrow><mml:mi>Q</mml:mi></mml:mrow><mml:mrow><mml:mtext>SH</mml:mtext></mml:mrow></mml:msub><mml:mfrac><mml:mrow><mml:mtext>DD</mml:mtext><mml:mfenced separators="" open="(" close=")"><mml:mrow><mml:mtext>GE</mml:mtext></mml:mrow></mml:mfenced></mml:mrow><mml:mrow><mml:mtext>DD</mml:mtext><mml:mfenced separators="" open="(" close=")"><mml:mrow><mml:mtext>building</mml:mtext></mml:mrow></mml:mfenced></mml:mrow></mml:mfrac><mml:mo class="MathClass-punc">,</mml:mo></mml:math></disp-formula></p>
<p>DD(building) stands for the standard SIA 2028 heating DDs of the climatic station associated to the building of the calibration set. The assumption behind this climatic correction is that the yearly demand for SH depends linearly on the DD. For this reason a ratio of DD between two climatic regions allows to estimate the <italic>Q</italic><sub>SH</sub> of a building in various climates.</p>
<p>Finally, the SITG IDC and GEAK data sets allow computing 15,588 and 11,499 <inline-formula><mml:math id="M9"><mml:msubsup><mml:mrow><mml:mi>Q</mml:mi></mml:mrow><mml:mrow><mml:mtext>SH</mml:mtext></mml:mrow><mml:mrow><mml:mtext>GE</mml:mtext></mml:mrow></mml:msubsup></mml:math></inline-formula> values normalized to the Geneva climatic reference.</p>
</sec>
<sec id="S2-3-3-2">
<title>Computing the DD for Each Building of the GWR</title>
<p>Combining the geographical coordinates with a topographic altitude model permits to compute the altitude of each building of the GWR using Eq. <xref ref-type="disp-formula" rid="E6">6</xref>. Figure <xref ref-type="fig" rid="F2">2</xref> illustrates the fit of the linear regression model estimating DD(building) by means of the building altitude Alt(building) and latitude Lat(building)
<disp-formula id="E6"><label>(6)</label><mml:math id="M10"><mml:mtext>DD</mml:mtext><mml:mfenced separators="" open="(" close=")"><mml:mrow><mml:mtext>building</mml:mtext></mml:mrow></mml:mfenced><mml:mo class="MathClass-rel">&#x0003D;</mml:mo><mml:mn>1484</mml:mn><mml:mo class="MathClass-bin">&#x0002B;</mml:mo><mml:mn>2</mml:mn><mml:mo class="MathClass-punc">.</mml:mo><mml:mn>42</mml:mn><mml:mtext>&#x000A0;Alt</mml:mtext><mml:mfenced separators="" open="(" close=")"><mml:mrow><mml:mtext>building</mml:mtext></mml:mrow></mml:mfenced><mml:mo class="MathClass-bin">&#x0002B;</mml:mo><mml:mn>0</mml:mn><mml:mo class="MathClass-punc">.</mml:mo><mml:mn>0035</mml:mn><mml:mtext>&#x000A0;Lat</mml:mtext><mml:mfenced separators="" open="(" close=")"><mml:mrow><mml:mtext>building</mml:mtext></mml:mrow></mml:mfenced><mml:mo class="MathClass-punc">.</mml:mo></mml:math></disp-formula></p>
</sec>
<sec id="S2-3-3-3">
<title>Statistical Analysis by Building Category and Age</title>
<p>For the purpose of statistical analysis, the previous data is grouped in four categories of buildings (multi-family residential, individual residential, non-residential, mixed use). For each of these categories, the data is further divided into 12 construction periods, and analyzed in terms of the statistical distribution of <inline-formula><mml:math id="M11"><mml:msubsup><mml:mrow><mml:mi>Q</mml:mi></mml:mrow><mml:mrow><mml:mtext>SH</mml:mtext></mml:mrow><mml:mrow><mml:mtext>GE</mml:mtext></mml:mrow></mml:msubsup></mml:math></inline-formula> as displayed in Figure <xref ref-type="fig" rid="F4">4</xref>. At this stage, it is worthwhile noticing that the variability within each construction period is much higher than between the periods, as previously observed by Khoury (<xref ref-type="bibr" rid="B18">2014</xref>). Note that this subdivision is different from the one used for the <italic>A<sub>E</sub></italic> estimation, since the building characteristics that influence the specific heat demand are not the same as those influencing the ratio between <italic>A<sub>E</sub></italic> and <italic>A</italic><sub>gross</sub>.</p>
<fig position="float" id="F4">
<label>Figure 4</label>
<caption><p>Boxplot distribution of <inline-formula><mml:math id="M12"><mml:msubsup><mml:mrow><mml:mi>Q</mml:mi></mml:mrow><mml:mrow><mml:mtext>SH</mml:mtext></mml:mrow><mml:mrow><mml:mtext>GE</mml:mtext></mml:mrow></mml:msubsup></mml:math></inline-formula> by construction period and building category (SITG IDC database).</p></caption>
<graphic xlink:href="fbuil-03-00053-g004.tif"/>
</fig>
<p>Finally, for each building category and construction period, the average SH demand, which will be used for extrapolation of the GWR database is defined by
<disp-formula id="E7"><label>(7)</label><mml:math id="M13"><mml:mover accent="false" class="mml-overline"><mml:mrow><mml:msubsup><mml:mrow><mml:mi>Q</mml:mi></mml:mrow><mml:mrow><mml:mtext>SH</mml:mtext></mml:mrow><mml:mrow><mml:mtext>GE</mml:mtext></mml:mrow></mml:msubsup></mml:mrow><mml:mo accent="true">&#x000AF;</mml:mo></mml:mover><mml:mo class="MathClass-rel">&#x0003D;</mml:mo><mml:mfrac><mml:mrow><mml:msub><mml:mrow><mml:mo class="MathClass-op">&#x02211;</mml:mo></mml:mrow><mml:mrow><mml:mrow><mml:mo class="MathClass-open">&#x0007B;</mml:mo><mml:mo class="MathClass-close">&#x0007D;</mml:mo></mml:mrow></mml:mrow></mml:msub><mml:msubsup><mml:mrow><mml:mi>Q</mml:mi></mml:mrow><mml:mrow><mml:mtext>SH</mml:mtext></mml:mrow><mml:mrow><mml:mtext>GE</mml:mtext></mml:mrow></mml:msubsup><mml:msub><mml:mrow><mml:mi>A</mml:mi></mml:mrow><mml:mrow><mml:mi>E</mml:mi></mml:mrow></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mrow><mml:mo class="MathClass-op">&#x02211;</mml:mo></mml:mrow><mml:mrow><mml:mrow><mml:mo class="MathClass-open">&#x0007B;</mml:mo><mml:mo class="MathClass-close">&#x0007D;</mml:mo></mml:mrow></mml:mrow></mml:msub><mml:msub><mml:mrow><mml:mi>A</mml:mi></mml:mrow><mml:mrow><mml:mi>E</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfrac><mml:mo class="MathClass-punc">.</mml:mo></mml:math></disp-formula></p>
<p>The sum in Eq. <xref ref-type="disp-formula" rid="E7">7</xref> is made for all buildings of same category and construction period contained in the calibration samples. The average is weighted by <italic>A<sub>E</sub></italic> to give more importance to large buildings since they will also have more influence in the energy demand of a portion of territory. This will reduce the bias that could be introduced by small buildings having extreme specific heat demand <inline-formula><mml:math id="M14"><mml:msubsup><mml:mrow><mml:mi>Q</mml:mi></mml:mrow><mml:mrow><mml:mtext>SH</mml:mtext></mml:mrow><mml:mrow><mml:mtext>GE</mml:mtext></mml:mrow></mml:msubsup></mml:math></inline-formula>.</p>
<p>This analysis is done separately for the SITG IDC and GEAK datasets, the respective values being used for the reconstruction of the entire GWR building stock located in Geneva, respectively, for the rest of Switzerland.</p>
</sec>
<sec id="S2-3-3-4">
<title>Heat Demand at Building and Pixel Levels</title>
<p>For each building of the GWR database, the final energy demand per square meter is estimated by the average demand of the corresponding category and construction period using
<disp-formula id="E8"><label>(8)</label><mml:math id="M15"><mml:mover accent='true'><mml:mi>E</mml:mi><mml:mo>&#x0005E;</mml:mo></mml:mover><mml:mo class="MathClass-rel">&#x0003D;</mml:mo><mml:mrow><mml:mfrac bevelled='true'><mml:mrow><mml:mn>1</mml:mn></mml:mrow><mml:mrow><mml:msub><mml:mrow><mml:mn>&#x003B7;</mml:mn></mml:mrow><mml:mrow><mml:mtext>EC</mml:mtext></mml:mrow></mml:msub></mml:mrow></mml:mfrac></mml:mrow><mml:mfenced separators="" open="(" close=")"><mml:mrow><mml:mover accent="false" class="mml-overline"><mml:mrow><mml:msubsup><mml:mrow><mml:mi>Q</mml:mi></mml:mrow><mml:mrow><mml:mtext>SH</mml:mtext></mml:mrow><mml:mrow><mml:mtext>GE</mml:mtext></mml:mrow></mml:msubsup></mml:mrow><mml:mo accent="true">&#x000AF;</mml:mo></mml:mover><mml:mfrac><mml:mrow><mml:mtext>DD</mml:mtext><mml:mrow><mml:mo class="MathClass-open">(</mml:mo><mml:mrow><mml:mtext>building</mml:mtext></mml:mrow><mml:mo class="MathClass-close">)</mml:mo></mml:mrow></mml:mrow><mml:mrow><mml:mtext>DD</mml:mtext><mml:mrow><mml:mo class="MathClass-open">(</mml:mo><mml:mrow><mml:mtext>GE</mml:mtext></mml:mrow><mml:mo class="MathClass-close">)</mml:mo></mml:mrow></mml:mrow></mml:mfrac><mml:mo class="MathClass-bin">&#x0002B;</mml:mo><mml:msub><mml:mrow><mml:mi>Q</mml:mi></mml:mrow><mml:mrow><mml:mtext>DHW</mml:mtext></mml:mrow></mml:msub></mml:mrow></mml:mfenced></mml:math></disp-formula></p>
<p>Since the average specific heat demand <inline-formula><mml:math id="M16"><mml:mover accent="false" class="mml-overline"><mml:mrow><mml:msubsup><mml:mrow><mml:mi>Q</mml:mi></mml:mrow><mml:mrow><mml:mtext>SH</mml:mtext></mml:mrow><mml:mrow><mml:mtext>GE</mml:mtext></mml:mrow></mml:msubsup></mml:mrow><mml:mo accent="true">&#x000AF;</mml:mo></mml:mover></mml:math></inline-formula> is normalized to the Geneva climate, it must then be adapted to the local climate conditions in which this estimation will be used. The DD ratio of Eq. <xref ref-type="disp-formula" rid="E8">8</xref>&#x02014;the inverse of the one of Eq. <xref ref-type="disp-formula" rid="E5">5</xref>&#x02014;transforms the <italic>Q<sub>h</sub></italic> of the Geneva climate into the ambient building climate. The DD(building) of the building is computed by using in Eq. <xref ref-type="disp-formula" rid="E6">6</xref> the geographical coordinates and the altitude of the building.</p>
<p>On this basis, the sum of the estimated heat demand of all buildings contained in a pixel of territory is computed using
<disp-formula id="E9"><label>(9)</label><mml:math id="M17"><mml:msub><mml:mrow><mml:mover accent='true'><mml:mi mathvariant="italic">SE</mml:mi><mml:mo>&#x0005E;</mml:mo></mml:mover></mml:mrow><mml:mrow><mml:mtext>Pixel</mml:mtext></mml:mrow></mml:msub><mml:mo class="MathClass-rel">&#x0003D;</mml:mo><mml:mstyle displaystyle='true'><mml:munder><mml:mo>&#x02211;</mml:mo><mml:mrow><mml:mi>B</mml:mi><mml:mo class="MathClass-rel">&#x02208;</mml:mo><mml:mtext>Pixel</mml:mtext></mml:mrow></mml:munder></mml:mstyle><mml:mover accent="false"><mml:mrow><mml:msub><mml:mrow><mml:mtext>SE</mml:mtext></mml:mrow><mml:mrow><mml:mi>B</mml:mi></mml:mrow></mml:msub></mml:mrow><mml:mrow><mml:mo class="MathClass-op">&#x0005E;</mml:mo></mml:mrow></mml:mover><mml:mo class="MathClass-rel">&#x0003D;</mml:mo><mml:mstyle displaystyle='true'><mml:munder><mml:mo>&#x02211;</mml:mo><mml:mrow><mml:mi>B</mml:mi><mml:mo class="MathClass-rel">&#x02208;</mml:mo><mml:mtext>Pixel</mml:mtext></mml:mrow></mml:munder></mml:mstyle><mml:mover accent="false"><mml:mrow><mml:msub><mml:mrow><mml:mi>A</mml:mi></mml:mrow><mml:mrow><mml:mi>E</mml:mi></mml:mrow></mml:msub></mml:mrow><mml:mo class="MathClass-op">&#x0005E;</mml:mo></mml:mover><mml:mover accent="false"><mml:mrow><mml:mi>E</mml:mi></mml:mrow><mml:mo class="MathClass-op">&#x0005E;</mml:mo></mml:mover><mml:mo class="MathClass-punc">.</mml:mo></mml:math></disp-formula></p>
<p>The upper procedure is repeated for the entire Swiss territory, for square pixels of scalable sizes, ranging from 100&#x02009;m to 1.6&#x02009;km.</p>
</sec>
<sec id="S2-3-3-5">
<title>Confidence Intervals</title>
<p>For each of the above pixels, we compute a confidence interval for the estimated heat demand value. It is computed using the bootstrap resampling algorithm (Efron and Tibshirani, <xref ref-type="bibr" rid="B12">1993</xref>), which consists in generating a heat demand distribution replicating the dispersion of the calibration datasets. A random sampling within the sets of relative errors <inline-formula><mml:math id="M18"><mml:mn>&#x00394;</mml:mn><mml:mover accent="false"><mml:mrow><mml:msub><mml:mrow><mml:mi>A</mml:mi></mml:mrow><mml:mrow><mml:mi>E</mml:mi></mml:mrow></mml:msub></mml:mrow><mml:mo class="MathClass-op">&#x0005E;</mml:mo></mml:mover></mml:math></inline-formula> defined by Eqs. <xref ref-type="disp-formula" rid="E1">1</xref> and <xref ref-type="disp-formula" rid="E2">2</xref> allows to replicate the error of the linear regression models used to estimate the heated surface <italic>A<sub>E</sub></italic>. A random sampling in the distribution of <inline-formula><mml:math id="M19"><mml:msubsup><mml:mrow><mml:mi>Q</mml:mi></mml:mrow><mml:mrow><mml:mtext>SH</mml:mtext></mml:mrow><mml:mrow><mml:mtext>GE</mml:mtext></mml:mrow></mml:msubsup></mml:math></inline-formula> values replicates the diversity of heat demand per square meter within a building category.</p>
<p>Finally, for each building of the pixel, a replicated <inline-formula><mml:math id="M20"><mml:msup><mml:mrow><mml:mi>&#x000CA;</mml:mi></mml:mrow><mml:mrow><mml:mo class="MathClass-bin">&#x02217;</mml:mo></mml:mrow></mml:msup></mml:math></inline-formula> value is generated by replacing the average <inline-formula><mml:math id="M21"><mml:mover accent="false" class="mml-overline"><mml:mrow><mml:msubsup><mml:mrow><mml:mi>Q</mml:mi></mml:mrow><mml:mrow><mml:mtext>SH</mml:mtext></mml:mrow><mml:mrow><mml:mtext>GE</mml:mtext></mml:mrow></mml:msubsup></mml:mrow><mml:mo accent="true">&#x000AF;</mml:mo></mml:mover></mml:math></inline-formula> value of Eq. <xref ref-type="disp-formula" rid="E8">8</xref> by a randomly picked value in the corresponding calibration dataset (same building category and construction period). Similarly, the heated surface <inline-formula><mml:math id="M22"><mml:mover accent="false"><mml:mrow><mml:msub><mml:mrow><mml:mi>A</mml:mi></mml:mrow><mml:mrow><mml:mi>E</mml:mi></mml:mrow></mml:msub></mml:mrow><mml:mo class="MathClass-op">&#x0005E;</mml:mo></mml:mover></mml:math></inline-formula> is replaced by
<disp-formula id="E10"><label>(10)</label><mml:math id="M23"><mml:msup><mml:mrow><mml:mover accent="false"><mml:mrow><mml:msub><mml:mrow><mml:mi>A</mml:mi></mml:mrow><mml:mrow><mml:mi>E</mml:mi></mml:mrow></mml:msub></mml:mrow><mml:mo class="MathClass-op">&#x0005E;</mml:mo></mml:mover></mml:mrow><mml:mrow><mml:mo class="MathClass-bin">&#x02217;</mml:mo></mml:mrow></mml:msup><mml:mo class="MathClass-rel">&#x0003D;</mml:mo><mml:mfenced separators="" open="(" close=")"><mml:mrow><mml:mn>1</mml:mn><mml:mo class="MathClass-bin">&#x0002B;</mml:mo><mml:mn>&#x00394;</mml:mn><mml:mover accent="false"><mml:mrow><mml:msub><mml:mrow><mml:mi>A</mml:mi></mml:mrow><mml:mrow><mml:mi>E</mml:mi></mml:mrow></mml:msub></mml:mrow><mml:mo class="MathClass-op">&#x0005E;</mml:mo></mml:mover></mml:mrow></mml:mfenced><mml:mover accent="false"><mml:mrow><mml:msub><mml:mrow><mml:mi>A</mml:mi></mml:mrow><mml:mrow><mml:mi>E</mml:mi></mml:mrow></mml:msub></mml:mrow><mml:mo class="MathClass-op">&#x0005E;</mml:mo></mml:mover><mml:mo class="MathClass-punc">,</mml:mo></mml:math></disp-formula>
where <inline-formula><mml:math id="M24"><mml:mn>&#x00394;</mml:mn><mml:mover accent="false"><mml:mrow><mml:msub><mml:mrow><mml:mi>A</mml:mi></mml:mrow><mml:mrow><mml:mi>E</mml:mi></mml:mrow></mml:msub></mml:mrow><mml:mo class="MathClass-op">&#x0005E;</mml:mo></mml:mover></mml:math></inline-formula> is a randomly picked relative error of the corresponding linear regression model. Feeding the <inline-formula><mml:math id="M25"><mml:msup><mml:mrow><mml:mi>&#x000CA;</mml:mi></mml:mrow><mml:mrow><mml:mo class="MathClass-bin">&#x02217;</mml:mo></mml:mrow></mml:msup></mml:math></inline-formula> and <inline-formula><mml:math id="M26"><mml:msup><mml:mrow><mml:mover accent="false"><mml:mrow><mml:msub><mml:mrow><mml:mi>A</mml:mi></mml:mrow><mml:mrow><mml:mi>E</mml:mi></mml:mrow></mml:msub></mml:mrow><mml:mo class="MathClass-op">&#x0005E;</mml:mo></mml:mover></mml:mrow><mml:mrow><mml:mo class="MathClass-bin">&#x02217;</mml:mo></mml:mrow></mml:msup></mml:math></inline-formula> values into Eq. <xref ref-type="disp-formula" rid="E9">9</xref>, generates a replicated heat demand for the entire pixel. Repeating this procedure a 1,000 times per pixel generates the heat demand distribution of each pixel. Finally, the limits of the 10% level confidence interval are the 5 and 95% percentiles of this distribution. Similarly, this distribution is used to calculate the 5 and 1% level confidence intervals.</p>
</sec>
</sec>
</sec>
<sec id="S2-4">
<title>Geo-Dependent Electricity Demand</title>
<p>This section describes the model used to decompose the electric demand of a territorial unit into various activities and groups of electric appliances (Schneider et al., <xref ref-type="bibr" rid="B36">2017</xref>). The choice of a Swiss municipality is adequate since it represents the smallest political entity of Switzerland. For this reason many socioeconomic indicators are available at this level. In 2016, Switzerland had 2,287 municipalities of quite heterogeneous size. The number of residential dwellings ranges from 14 to 224,774, the city of Z&#x000FC;rich being the biggest municipality after the city of Geneva. Since the spatial constraint for electricity is lower than for heat, it did not seem of interest to break down the territory into pixels as in the case of heat demand. Another particularity of certain regions is that the ratio between main and secondary residences varies a lot. The percentage of main residential dwellings ranges from 52% for the Canton of Graub&#x000FC;nden to 98.8% for the Canton of Basel. This socio-economic characteristic has an important influence on energy demand.</p>
<p>As illustrated in Figure <xref ref-type="fig" rid="F5">5</xref>, the yearly demand of a municipality is split into three main sectors, each one with its own estimation algorithm as described in the following two subsections. The yearly consumption (YC) is split into 36 activities and 18 electric appliances such as lighting, fridges, TV, etc. A further step consists in transforming the yearly demand into estimated load curves using a library of load curve shapes.</p>
<fig position="float" id="F5">
<label>Figure 5</label>
<caption><p>Overview of the geo-dependent electricity demand model.</p></caption>
<graphic xlink:href="fbuil-03-00053-g005.tif"/>
</fig>
<p>The heat demand model of Section &#x0201C;<xref ref-type="sec" rid="S2-3">Geo-Dependent Heat Demand</xref>&#x0201D; allows to estimate the final energy demand for SH and DHW. Combining these estimations with fractions of dwelling using electric heat production systems permits to estimate the amount of electricity used for SH and DHW. In case electric heat production is based on a heat pump, we use an average coefficient of performance of 2.5 to convert useful heat into electric demand.</p>
<sec id="S2-4-4">
<title>Yearly Demand per Activity and Electric Appliance</title>
<sec id="S2-4-4-6">
<title>Industry and Services</title>
<p>For each municipality, the estimation of the YC of the industry and services sector is based on the number of employees per NOGA activity code available in the STATENT database (OFS, <xref ref-type="bibr" rid="B27">2014b</xref>). This statistic is combined with unitary average consumption per employe and NOGA code. For the territory of Geneva and of the EOSh group, these unitary consumptions are estimated using the total billed electricity per activity. For the remaining Swiss municipalities, the average unitary consumptions are calculated using a yearly national survey collected from approximately 12,000 companies (Bendel et al., <xref ref-type="bibr" rid="B4">2011</xref>). This approach is similar to the one used by the FORECAST/eLOAD model (Jakob et al., <xref ref-type="bibr" rid="B16">2014</xref>), with the difference that FORECAST/eLOAD uses profiles for occupancy and appliance distribution over time provided by the SIA Standard 2024 (SIA, <xref ref-type="bibr" rid="B40">2015</xref>).</p>
<p>A next step consists in estimating for each NOGA activity code, the amount of electricity used for each group of electric appliances. This further distribution of the electric consumption is based on average fractions of the total electricity consumed by each group of electric appliances; these fractions come from audit and case studies. Finally, for each NOGA activity code these fractions allow to split up the total yearly demand into different appliances, as for example lighting, motor force, heat, etc. After completion of this step, the yearly estimated electricity consumption of the Industry and services sector is split into 55 activities and 15 electric appliances.</p>
</sec>
<sec id="S2-4-4-7">
<title>Common Appliances and Public Lighting</title>
<p>The common appliances of a collective residential building include the lighting of the staircase, the elevator, the common laundry, air ventilation and other technical installations. The size and age will of course have an influence on the consumption of these services. Nevertheless, for estimation on a large scale, average values representing an average sized building will be accurate enough. For public lighting the main underlying assumption is that the installed light power (including traffic lights) is linked to urban density. This approximation does not account for specificities, as for example extra urban highways and tunnels. These two kinds of electric consumption are supposed to depend mainly on the number of collective dwellings. Consumption is estimated by combining number of dwellings and unitary consumptions per dwelling.</p>
<p>As in the previous section, priority is given to unitary consumptions calibrated on local ESCO bills to account for regional differences. For example, there are big differences among several Swiss regions in use practices of lighting in the common areas of buildings. In Geneva, for example, it is mandatory to have the staircase illuminated day and night. The ECO21 program promotes low consumption light fixtures with occupancy sensors allowing the light to switch on only when required. In the Canton of Vaud, the common practice is to have staircase lighting with a manual switch.</p>
</sec>
<sec id="S2-4-4-8">
<title>The Residential Sector</title>
<p>The consumption of the average household is estimated by combining equipment rates, times of use and average power for each main use appliance. The unexplained part is included in the appliance &#x0201C;other.&#x0201D; A stock model, based on sales statistics of electric devices per energy efficiency label, permits to estimate the average power used by a device. Such sales statistics are available in the report (EAE, <xref ref-type="bibr" rid="B11">2009</xref>), for example.</p>
<p>Several European norms define the efficiency of the device in terms of the electric consumption per unit according to the device type. For fridges (2003/66/CE), the label gives the ratio between the consumptions of the labeled device and a standard one. In this case, the normal consumption of the standard fridge depends mainly on the refrigerated volume.</p>
<p>The average YC of a device currently in operation is computed by summing the products of average consumption per efficiency label YC(<italic>E</italic><sub>Label</sub>) and the fraction of devices in operation
<disp-formula id="E11"><label>(11)</label><mml:math id="M27"><mml:mtext>YC</mml:mtext><mml:mo class="MathClass-rel">&#x0003D;</mml:mo><mml:mstyle displaystyle='true'><mml:munder><mml:mo>&#x02211;</mml:mo><mml:mrow><mml:mrow><mml:mo class="MathClass-open">(</mml:mo><mml:mrow><mml:msub><mml:mrow><mml:mi>E</mml:mi></mml:mrow><mml:mrow><mml:mtext>Label</mml:mtext></mml:mrow></mml:msub></mml:mrow><mml:mo class="MathClass-close">)</mml:mo></mml:mrow></mml:mrow></mml:munder></mml:mstyle><mml:mtext>YC</mml:mtext><mml:mrow><mml:mo class="MathClass-open">(</mml:mo><mml:mrow><mml:msub><mml:mrow><mml:mi>E</mml:mi></mml:mrow><mml:mrow><mml:mtext>Label</mml:mtext></mml:mrow></mml:msub></mml:mrow><mml:mo class="MathClass-close">)</mml:mo></mml:mrow><mml:mi>F</mml:mi><mml:mrow><mml:mo class="MathClass-open">(</mml:mo><mml:mrow><mml:msub><mml:mrow><mml:mi>E</mml:mi></mml:mrow><mml:mrow><mml:mtext>Label</mml:mtext></mml:mrow></mml:msub></mml:mrow><mml:mo class="MathClass-close">)</mml:mo></mml:mrow><mml:mo class="MathClass-punc">.</mml:mo></mml:math></disp-formula></p>
<p>For most electric devices, the same average estimated YCs are used for the entire Swiss territory. The main regional difference concerns the equipment rate of electric cookers.</p>
</sec>
</sec>
<sec id="S2-4-5">
<title>Estimation of Load Curves</title>
<p>A library of average load curve shapes per electric appliance type and activity permits to split the YC into monthly estimations. The used percentages defining these shapes are based on measured seasonal effects that are particularly pronounced for heating and lighting. Monthly demand is further broken down into daily demand for working and non-working days and finally into hourly demand. The load curve of a particular municipality is estimated by adding the individual load curves of all activities and all electric appliances.</p>
</sec>
</sec>
<sec id="S2-5">
<title>GIS Energy Demand and Renewable Resources Database</title>
<p>Relational database servers and data exchange protocols, as for example the simple object access protocol (SOAP) are powerful tools allowing data interconnection originating from different sources. To facilitate data exchange, a database has been set-up in collaboration with EPFL that consolidates results of the geo-dependent energy supply and demand models. This consolidation fulfills the following requirements:
<list list-type="bullet">
<list-item><p>Gives the results of our model estimations for energy supply and demand on a harmonized geographical aggregation level (municipality level and 200&#x02009;m&#x02009;&#x000D7;&#x02009;200&#x02009;m pixel size).</p></list-item>
<list-item><p>Displays documentation on the delivered data.</p></list-item>
<list-item><p>Provides easy and flexible access to data using a web-service.</p></list-item>
<list-item><p>Provides scripts allowing to build a part of this database (heat demand).</p></list-item>
</list></p>
<p>The actual release of the database contains rooftop PV potential (Assouline et al., <xref ref-type="bibr" rid="B2">2017</xref>) with monthly and yearly values for each municipality in Switzerland as well as yearly heat demand and electricity estimations derived from the models presented in this paper. The database provides PV supply potential and heat demand estimations up to a resolution of 200&#x02009;m&#x02009;&#x000D7;&#x02009;200&#x02009;m pixels. Concerning electricity demand, the database contains for each municipality the yearly demand estimation split up into activities and appliances. A dedicated web-service allows to query the database using the SOAP protocol. The user manual and sample of scripts to query the database are in the report of Schneider et al. (<xref ref-type="bibr" rid="B34">2015</xref>).</p>
</sec>
</sec>
<sec id="S3">
<title>Results and Applications of the Models</title>
<p>The primary target of both models is to achieve a geo-dependent energy characterization of the Swiss energy demand. Nevertheless, it is of interest to derive some statistics aggregated at the national level and to compare them (as shown in Sections &#x0201C;<xref ref-type="sec" rid="S3-6">Heat Demand Statistics Aggregated at the National Level</xref>&#x0201D; and &#x0201C;<xref ref-type="sec" rid="S3-9">Validation of the Electricity Demand Model</xref>&#x0201D;) with other available statistics. This helps identifying potential biases of the models.</p>
<p>Sections &#x0201C;<xref ref-type="sec" rid="S3-7">Heat Demand Maps</xref>,&#x0201D; &#x0201C;<xref ref-type="sec" rid="S3-8">Impact of Large-scale Retrofit on Heat Demand</xref>,&#x0201D; and &#x0201C;<xref ref-type="sec" rid="S3-10">Electricity Demand Maps and Web Platform</xref>&#x0201D; give some applications of the models, as for example drawing GIS maps and estimating possible potentials of reduction of demand linked to retrofit scenarios.</p>
<sec id="S3-6">
<title>Heat Demand Statistics Aggregated at the National Level</title>
<p>Table <xref ref-type="table" rid="T2">2</xref> contains aggregated values&#x02014;per building category and construction period&#x02014;of the total heated surface <italic>A<sub>E</sub></italic> and final energy consumption for SH and DHW. Sufficient information is available to calculate these estimations for around 90% of the 1.93 million buildings listed in the 2013 version of the GWR. These values lead to a total heated surface estimation of 702 million m<sup>2</sup> and a total final energy demand of 93.7&#x02009;TWh/year (76.8&#x02009;TWh/year for residential and 16.9&#x02009;TWh/year for mixed use and non-residential buildings). Within the residential sector 71% of the energy is consumed by buildings built before 1980. The fact that these buildings also have a high heat demand per square meter emphasizes the importance of thermal envelope retrofitting.</p>
<table-wrap position="float" id="T2">
<label>Table 2</label>
<caption><p>Aggregated results of geo-dependent heat demand model.</p></caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th valign="top" align="center"/>
<th valign="top" align="center" colspan="4">Construction periods<hr/></th>
<th valign="top" align="center">Total (%) (all constr. periods)</th>
</tr>
<tr>
<th valign="top" align="center"/>
<th valign="top" align="center">Before 1945</th>
<th valign="top" align="center">1945&#x02013;1980</th>
<th valign="top" align="center">After 1980</th>
<th valign="top" align="center">Unknown</th>
<th valign="top" align="center"/>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left" colspan="6"><bold>Total number of buildings in GWR</bold></td>
</tr>
<tr>
<td valign="top" align="left">MF</td>
<td valign="top" align="center">110,436</td>
<td valign="top" align="center">127,381</td>
<td valign="top" align="center">118,319</td>
<td valign="top" align="center">61</td>
<td valign="top" align="center">356,197 (18%)</td>
</tr>
<tr>
<td valign="top" align="left">SF</td>
<td valign="top" align="center">384,627</td>
<td valign="top" align="center">405,943</td>
<td valign="top" align="center">464,848</td>
<td valign="top" align="center">594</td>
<td valign="top" align="center">1,256,012 (65%)</td>
</tr>
<tr>
<td valign="top" align="left">MU</td>
<td valign="top" align="center">39,175</td>
<td valign="top" align="center">24,003</td>
<td valign="top" align="center">15,906</td>
<td valign="top" align="center">79</td>
<td valign="top" align="center">79,163 (4%)</td>
</tr>
<tr>
<td valign="top" align="left">NR</td>
<td valign="top" align="center">38,841</td>
<td valign="top" align="center">46,961</td>
<td valign="top" align="center">51,000</td>
<td valign="top" align="center">103,644</td>
<td valign="top" align="center">240,446 (12%)</td>
</tr>
<tr>
<td valign="top" align="left">Total</td>
<td valign="top" align="center">573,079</td>
<td valign="top" align="center">604,288</td>
<td valign="top" align="center">650,073</td>
<td valign="top" align="center">104,378</td>
<td valign="top" align="center">1,931,818</td>
</tr>
<tr>
<td valign="top" align="left" colspan="6"><bold>Nb of buildings with heated surface</bold></td>
</tr>
<tr>
<td valign="top" align="left">MF</td>
<td valign="top" align="center">109,428</td>
<td valign="top" align="center">125,832</td>
<td valign="top" align="center">116,987</td>
<td valign="top" align="center">47</td>
<td valign="top" align="center">352,294 (20%)</td>
</tr>
<tr>
<td valign="top" align="left">SF</td>
<td valign="top" align="center">379,976</td>
<td valign="top" align="center">402,058</td>
<td valign="top" align="center">460,062</td>
<td valign="top" align="center">527</td>
<td valign="top" align="center">1,242,623 (71%)</td>
</tr>
<tr>
<td valign="top" align="left">MU</td>
<td valign="top" align="center">37,605</td>
<td valign="top" align="center">23,023</td>
<td valign="top" align="center">15,090</td>
<td valign="top" align="center">58</td>
<td valign="top" align="center">75,776 (4%)</td>
</tr>
<tr>
<td valign="top" align="left">NR</td>
<td valign="top" align="center">20,130</td>
<td valign="top" align="center">26,579</td>
<td valign="top" align="center">23,216</td>
<td valign="top" align="center">9,979</td>
<td valign="top" align="center">79,904 (5%)</td>
</tr>
<tr>
<td valign="top" align="left">Total</td>
<td valign="top" align="center">547,139</td>
<td valign="top" align="center">577,492</td>
<td valign="top" align="center">615,355</td>
<td valign="top" align="center">10,611</td>
<td valign="top" align="center">1,750,597</td>
</tr>
<tr>
<td valign="top" align="left" colspan="6"><bold>Total heated surface A<sub>E</sub> (millions of m<sup>2</sup>)</bold></td>
</tr>
<tr>
<td valign="top" align="left">MF</td>
<td valign="top" align="center">69.64</td>
<td valign="top" align="center">121.92</td>
<td valign="top" align="center">129.08</td>
<td valign="top" align="center">0.04</td>
<td valign="top" align="center">320.7 (46%)</td>
</tr>
<tr>
<td valign="top" align="left">SF</td>
<td valign="top" align="center">88.71</td>
<td valign="top" align="center">75.17</td>
<td valign="top" align="center">94.91</td>
<td valign="top" align="center">0.07</td>
<td valign="top" align="center">258.9 (37%)</td>
</tr>
<tr>
<td valign="top" align="left">MU</td>
<td valign="top" align="center">22.38</td>
<td valign="top" align="center">22.25</td>
<td valign="top" align="center">18.20</td>
<td valign="top" align="center">0.04</td>
<td valign="top" align="center">62.9 (9%)</td>
</tr>
<tr>
<td valign="top" align="left">NR</td>
<td valign="top" align="center">11.58</td>
<td valign="top" align="center">20.77</td>
<td valign="top" align="center">23.31</td>
<td valign="top" align="center">3.62</td>
<td valign="top" align="center">59.3 (8%)</td>
</tr>
<tr>
<td valign="top" align="left">Total</td>
<td valign="top" align="center">192.3</td>
<td valign="top" align="center">240.1</td>
<td valign="top" align="center">265.5</td>
<td valign="top" align="center">3.8</td>
<td valign="top" align="center">701.7</td>
</tr>
<tr>
<td valign="top" align="left" colspan="6"><bold>Total final energy demand SE<sub>CH</sub> for SH and domestic hot water (TWh/year)</bold></td>
</tr>
<tr>
<td valign="top" align="left">MF</td>
<td valign="top" align="center">10.36</td>
<td valign="top" align="center">18.41</td>
<td valign="top" align="center">12.77</td>
<td valign="top" align="center">0.00</td>
<td valign="top" align="center">41.5 (44%)</td>
</tr>
<tr>
<td valign="top" align="left">SF</td>
<td valign="top" align="center">13.42</td>
<td valign="top" align="center">12.40</td>
<td valign="top" align="center">9.48</td>
<td valign="top" align="center">0.01</td>
<td valign="top" align="center">35.3 (38%)</td>
</tr>
<tr>
<td valign="top" align="left">MU</td>
<td valign="top" align="center">4.17</td>
<td valign="top" align="center">3.77</td>
<td valign="top" align="center">2.62</td>
<td valign="top" align="center">0.01</td>
<td valign="top" align="center">10.6 (11%)</td>
</tr>
<tr>
<td valign="top" align="left">NR</td>
<td valign="top" align="center">1.33</td>
<td valign="top" align="center">2.68</td>
<td valign="top" align="center">1.89</td>
<td valign="top" align="center">0.37</td>
<td valign="top" align="center">6.3 (7%)</td>
</tr>
<tr>
<td valign="top" align="left">Total</td>
<td valign="top" align="center">29.3</td>
<td valign="top" align="center">37.2</td>
<td valign="top" align="center">26.8</td>
<td valign="top" align="center">0.4</td>
<td valign="top" align="center">93.7</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<p><italic>MF, multi-family residential; MU, mixed use; SF, single family residential; NR, non-residential</italic>.</p>
</table-wrap-foot>
</table-wrap>
<p>Comparing these numbers with the estimation of an alternative study permits to detect a possible bias of the present model. For year 2013, Kemmler et al. (<xref ref-type="bibr" rid="B17">2014</xref>) estimate SE<sub>CH</sub> to be 91.1&#x02009;TWh/year, (59.5&#x02009;TWh/year for residential and 31.6&#x02009;TWh/year for mixed use and non-residential buildings). Although the two models have a good concordance for global demand, significant differences exist when considering the residential and non-residential sectors separately, mainly due to the differences between the estimated heated surfaces. In the case of the residential buildings, our model estimates a heated surface of 580&#x02009;million square meter that is significantly higher than the one 509&#x02009;million square meter estimated by Kemmler et al. (<xref ref-type="bibr" rid="B17">2014</xref>). This lower estimation would lead to a ratio <italic>f</italic> <sub>dwell</sub> of 1.2 that is significantly lower than the value of Table <xref ref-type="table" rid="T1">1</xref>.</p>
</sec>
<sec id="S3-7">
<title>Heat Demand Maps</title>
<p>Since the model delivers energy demand estimation at the building level, Eq. <xref ref-type="disp-formula" rid="E9">9</xref> permits to compute the aggregated demand for pixels of any size. Dividing the Swiss territory into a raster of pixels and exporting, pixel by pixel, the demand to an information system such as QGIS, allows us to draw heat demand maps. Figure <xref ref-type="fig" rid="F6">6</xref> gives an example of such a heat density map for Switzerland, with a zoom on the town of Martigny. A color ramp indicates the final energy consumption per square meter of territory for each pixel of 200&#x02009;m&#x02009;&#x000D7;&#x02009;200&#x02009;m size. Such maps permit to identify portions of territory having high demand density, being consequently suitable for district heating deployment. Cross-matching these demand maps with other geo-referred information, as for example availability of waste heat, permits to estimate the exploitation potential of such resources. Other information, as for instance, the percentage of demand covered by fossil energy carriers can be added to derive estimated CO<sub>2</sub> emission maps.</p>
<fig position="float" id="F6">
<label>Figure 6</label>
<caption><p>Swiss geographical information system map for heat demand and zoom on the town of Martigny.</p></caption>
<graphic xlink:href="fbuil-03-00053-g006.tif"/>
</fig>
</sec>
<sec id="S3-8">
<title>Impact of Large-scale Retrofit on Heat Demand</title>
<p>The previously presented geo-dependent heat demand database allows estimating the savings that could be achieved by large-scale retrofit of building envelope. The new energy policy scenario (NEP) of the Swiss Energy Strategy 2050 targets reducing today final energy demand for SH and DHW production to around 42&#x02009;TWh/year; this represents a decrease of 53%. This section challenges this scenario by making the optimistic assumption that today retrofit rate will double to reach 2%. If current retrofit practices are applied, the SIA 380 standard (SIA, <xref ref-type="bibr" rid="B38">2009</xref>) sets an upper limit <italic>Q</italic><sub>SH,lim</sub> (MJ/m<sup>2</sup>) for the calculated useful energy demand per square meter. This demand is calculated under normed conditions for indoor temperature and ventilation rate that are not often fulfilled in real use conditions after retrofit. This discrepancy between the normed and real use of the building induces a performance gap. This gap is the difference between the theoretical savings <italic>QS</italic><sub>Gross</sub> (MJ/m<sup>2</sup>) defined by
<disp-formula id="E12"><label>(12)</label><mml:math id="M28"><mml:msub><mml:mrow><mml:mi mathvariant="italic">QS</mml:mi></mml:mrow><mml:mrow><mml:mtext>Gross</mml:mtext></mml:mrow></mml:msub><mml:mo class="MathClass-rel">&#x0003D;</mml:mo><mml:msub><mml:mrow><mml:mi>Q</mml:mi></mml:mrow><mml:mrow><mml:mtext>SH</mml:mtext></mml:mrow></mml:msub><mml:mo class="MathClass-bin">&#x02212;</mml:mo><mml:msub><mml:mrow><mml:mi>Q</mml:mi></mml:mrow><mml:mrow><mml:mtext>SH,lim</mml:mtext></mml:mrow></mml:msub><mml:mo class="MathClass-punc">,</mml:mo></mml:math></disp-formula>
and the actual savings <italic>QS</italic><sub>Net</sub> (MJ/m<sup>2</sup>) defined by
<disp-formula id="E13"><label>(13)</label><mml:math id="M29"><mml:msub><mml:mrow><mml:mi mathvariant="italic">QS</mml:mi></mml:mrow><mml:mrow><mml:mtext>Net</mml:mtext></mml:mrow></mml:msub><mml:mo class="MathClass-rel">&#x0003D;</mml:mo><mml:msub><mml:mrow><mml:mi>Q</mml:mi></mml:mrow><mml:mrow><mml:mtext>SH</mml:mtext></mml:mrow></mml:msub><mml:mo class="MathClass-bin">&#x02212;</mml:mo><mml:msub><mml:mrow><mml:mi>Q</mml:mi></mml:mrow><mml:mrow><mml:mtext>SH_AR</mml:mtext></mml:mrow></mml:msub><mml:mo class="MathClass-punc">,</mml:mo></mml:math></disp-formula>
where <italic>Q</italic><sub>SH,AR</sub> is the actual measured energy demand per square meter after retrofit. The analysis of ten representative case studies (Khoury et al., <xref ref-type="bibr" rid="B19">2016</xref>) of recently retrofitted post-war multi-family residential buildings allowed to characterize the performance gap by means of a statistical correlation between <italic>QS</italic><sub>Gross</sub> and <italic>QS</italic><sub>Net</sub>
<disp-formula id="E14"><label>(14)</label><mml:math id="M30"><mml:msub><mml:mrow><mml:mi mathvariant="italic">QS</mml:mi></mml:mrow><mml:mrow><mml:mtext>Net</mml:mtext></mml:mrow></mml:msub><mml:mo class="MathClass-rel">&#x0003D;</mml:mo><mml:mn>0</mml:mn><mml:mo class="MathClass-punc">.</mml:mo><mml:mn>0009</mml:mn><mml:msup><mml:mrow><mml:mrow><mml:mo class="MathClass-open">(</mml:mo><mml:mrow><mml:msub><mml:mrow><mml:mi mathvariant="italic">QS</mml:mi></mml:mrow><mml:mrow><mml:mtext>Gross</mml:mtext></mml:mrow></mml:msub></mml:mrow><mml:mo class="MathClass-close">)</mml:mo></mml:mrow></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow></mml:msup><mml:mo class="MathClass-bin">&#x0002B;</mml:mo><mml:mn>0</mml:mn><mml:mo class="MathClass-punc">.</mml:mo><mml:mn>17</mml:mn><mml:msub><mml:mrow><mml:mi mathvariant="italic">QS</mml:mi></mml:mrow><mml:mrow><mml:mtext>Gross</mml:mtext></mml:mrow></mml:msub><mml:mspace width="1em" class="quad"/><mml:mtext>if</mml:mtext><mml:mspace width="1em" class="quad"/><mml:msub><mml:mrow><mml:mi mathvariant="italic">QS</mml:mi></mml:mrow><mml:mrow><mml:mtext>Gross</mml:mtext></mml:mrow></mml:msub><mml:mo class="MathClass-rel">&#x0003C;</mml:mo><mml:mn>600</mml:mn><mml:mtext>MJ</mml:mtext><mml:mo class="MathClass-bin">/</mml:mo><mml:msup><mml:mrow><mml:mtext>m</mml:mtext></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow></mml:msup><mml:mo class="MathClass-punc">.</mml:mo></mml:math></disp-formula></p>
<p>This relation (<italic>R</italic><sup>2</sup>&#x02009;&#x0003D;&#x02009;0.9897) takes account of the entire retrofit process, from the design stage (choice of solutions and use of simulation software) to the use of the buildings by the occupants and energy managers. It can be viewed as a characterization of the current retrofit and operation practices. In case <italic>QS</italic><sub>Gross</sub> exceeds 600, we use the more conservative value <italic>QS</italic><sub>Net</sub>&#x02009;&#x0003D;&#x02009;0.7 <italic>QS</italic><sub>Gross</sub>. This rule applies to buildings having a theoretical energy savings that lies outside the range of the building sample analyzed by Khoury et al. (<xref ref-type="bibr" rid="B19">2016</xref>).</p>
<p>The analysis of this section will show that taking account of the performance gap has a significant effect on the savings of large-scale retrofit programs. Figure <xref ref-type="fig" rid="F7">7</xref> shows the procedure used to estimate the net saving potential of a group of buildings that are supposed to be retrofitted in accordance with the efficiency limit of the SIA 380 standard. We start by assigning to each of these buildings a shape factor, which is defined as the ratio between the building thermal envelope surface <italic>A</italic><sub>th</sub> and its heated surface <italic>A<sub>E</sub></italic>. These ratios are taken from the SIA 2031 standard (SIA, <xref ref-type="bibr" rid="B41">2016</xref>) for all the building categories, except for the multi-family residential buildings. For the latter, the factors are estimated on the basis of the number of floors using the relation below, which was derived from the GEAK database.</p>
<disp-formula id="E15"><label>(15)</label><mml:math id="M31"><mml:mrow><mml:mfrac bevelled='true'><mml:mrow><mml:msub><mml:mrow><mml:mi>A</mml:mi></mml:mrow><mml:mrow><mml:mtext>th</mml:mtext></mml:mrow></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mrow><mml:mi>A</mml:mi></mml:mrow><mml:mrow><mml:mi>E</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfrac></mml:mrow><mml:mo class="MathClass-rel">&#x0003D;</mml:mo><mml:mn>0</mml:mn><mml:mo class="MathClass-punc">.</mml:mo><mml:mn>32</mml:mn><mml:mo class="MathClass-bin">&#x0002B;</mml:mo><mml:mrow><mml:mfrac bevelled='true'><mml:mrow><mml:mn>1</mml:mn><mml:mo class="MathClass-punc">.</mml:mo><mml:mn>97</mml:mn></mml:mrow><mml:mrow><mml:msqrt><mml:mrow><mml:msub><mml:mrow><mml:mi>N</mml:mi></mml:mrow><mml:mrow><mml:mtext>floors</mml:mtext></mml:mrow></mml:msub></mml:mrow></mml:msqrt></mml:mrow></mml:mfrac><mml:mo class="MathClass-punc">.</mml:mo></mml:mrow></mml:math></disp-formula>
<fig position="float" id="F7">
<label>Figure 7</label>
<caption><p>Estimation of gross and net energy saving potential after retrofit of a building group.</p></caption>
<graphic xlink:href="fbuil-03-00053-g007.tif"/>
</fig>
<p>These shape factors permit to compute for all buildings the limit value <italic>Q</italic><sub>SH,lim</sub>, which is the heat per square meter demand a building should not exceed after retrofit. The heat demand of the building for SH before retrofit is estimated by a randomly picked <italic>Q</italic><sub>SH</sub> value taken from our calibration set of buildings of same category and construction period (see Eq. <xref ref-type="disp-formula" rid="E5">5</xref>). This randomization replicates the variability of the observed distribution of heat demand of buildings of same category. Using an average value instead of this distribution would not have any effect on the average <italic>QS</italic><sub>Gross</sub> value, but would bias the <italic>QS</italic><sub>Net</sub> estimation, because of the quadratic term of Eq. <xref ref-type="disp-formula" rid="E14">14</xref>. Putting these two values into Eq. <xref ref-type="disp-formula" rid="E12">12</xref> allows to estimate the gross saving potential per square meter <italic>QS</italic><sub>Gross</sub> for each building. Eq. <xref ref-type="disp-formula" rid="E14">14</xref> allows to compute the net saving potential per square meter that is then converted into final energy using Eq. <xref ref-type="disp-formula" rid="E16">16</xref>.</p>
<disp-formula id="E16"><label>(16)</label><mml:math id="M32"><mml:msub><mml:mrow><mml:mi mathvariant="italic">ES</mml:mi></mml:mrow><mml:mrow><mml:mtext>Net</mml:mtext></mml:mrow></mml:msub><mml:mo class="MathClass-rel">&#x0003D;</mml:mo><mml:mrow><mml:mfrac bevelled='true'><mml:mrow><mml:mn>1</mml:mn></mml:mrow><mml:mrow><mml:msub><mml:mrow><mml:mn>&#x003B7;</mml:mn></mml:mrow><mml:mrow><mml:mtext>EC</mml:mtext></mml:mrow></mml:msub></mml:mrow></mml:mfrac></mml:mrow><mml:mspace width="1em" class="quad"/><mml:msub><mml:mrow><mml:mi mathvariant="italic">QS</mml:mi></mml:mrow><mml:mrow><mml:mtext>Net</mml:mtext></mml:mrow></mml:msub><mml:mspace width="1em" class="quad"/><mml:msub><mml:mrow><mml:mi>A</mml:mi></mml:mrow><mml:mrow><mml:mi>E</mml:mi></mml:mrow></mml:msub><mml:mo class="MathClass-punc">.</mml:mo></mml:math></disp-formula>
<p>Finally, to compute the total net savings <inline-formula><mml:math id="M33"><mml:mi>E</mml:mi><mml:msubsup><mml:mrow><mml:mi>S</mml:mi></mml:mrow><mml:mrow><mml:mtext>Net</mml:mtext></mml:mrow><mml:mrow><mml:mtext>CH</mml:mtext></mml:mrow></mml:msubsup></mml:math></inline-formula>, we sum the net saving potential <italic>ES</italic><sub>Net</sub> of all buildings supposed to be retrofitted. This procedure is repeated 1,000 times and the average of the <inline-formula><mml:math id="M34"><mml:mi>E</mml:mi><mml:msubsup><mml:mrow><mml:mi>S</mml:mi></mml:mrow><mml:mrow><mml:mtext>Net</mml:mtext></mml:mrow><mml:mrow><mml:mtext>CH</mml:mtext></mml:mrow></mml:msubsup></mml:math></inline-formula> values gives the net saving potential of the retrofitted building group.</p>
<p>For future projections concerning the building stock size and the evolution of its energy demand, we refer to the report of Prognos (Kirchner et al., <xref ref-type="bibr" rid="B20">2012</xref>). This study expects an increase of heated surface of 32% between 2010 and 2050. In the present simulation, it was supposed that all new buildings added to the current building stock consume 100&#x02009;MJ/m<sup>2</sup>/y of final energy for SH and DHW.</p>
<p>Figure <xref ref-type="fig" rid="F8">8</xref> shows how the possible evolution of the final energy demand for 2020, 2035, and 2050 using the previously explained estimation procedure. Under the assumption no retrofit is done, the total demand SE<sub>CH</sub> will increase proportionally less than the additional heated surface, since the new buildings are supposed to be very efficient. The doted gray lines are the expected evolution of demand according to the new energy policy scenario (NEP) and business as usual scenario (WWB) of the 2050 Swiss energy strategy. In our 2% per year retrofit rate scenario, it is assumed that the buildings offering the highest saving potential are retrofitted first. Even following this optimistic assumption the expected savings <inline-formula><mml:math id="M35"><mml:mi>E</mml:mi><mml:msubsup><mml:mrow><mml:mi>S</mml:mi></mml:mrow><mml:mrow><mml:mtext>Net</mml:mtext></mml:mrow><mml:mrow><mml:mtext>CH</mml:mtext></mml:mrow></mml:msubsup></mml:math></inline-formula> are significantly lower than the projection given by the WWB scenario. Disregarding the performance gap leads to savings <inline-formula><mml:math id="M36"><mml:mi>E</mml:mi><mml:msubsup><mml:mrow><mml:mi>S</mml:mi></mml:mrow><mml:mrow><mml:mtext>Gross</mml:mtext></mml:mrow><mml:mrow><mml:mtext>CH</mml:mtext></mml:mrow></mml:msubsup></mml:math></inline-formula> that are close to the projections of Prognos.</p>
<fig position="float" id="F8">
<label>Figure 8</label>
<caption><p>Evolution of final energy demand of the Swiss building stock for SH and domestic hot water (DHW).</p></caption>
<graphic xlink:href="fbuil-03-00053-g008.tif"/>
</fig>
</sec>
<sec id="S3-9">
<title>Validation of the Electricity Demand Model</title>
<p>This section presents two kinds of validations done by comparing estimates obtained from the model with available electricity consumption statistics. A first validation consists in comparing estimated and actual annual consumptions at the national and at different regional levels. This enables to check the accuracy of the unitary consumptions used to estimate the YCs in the various sectors of activity. A second validation compares the estimated hourly demand with the measured one. The way the model builds the estimated hourly load curve implies that load curves are identical for all the days of the same month and day type (working, non-working). It is thus adequate to compare the estimated load curve with the average load computed by taking separately working and non-working days for each month and hour of the day. This kind of comparison checks if the shapes of the load curve library and the weights used for aggregation replicate actual demand.</p>
<sec id="S3-9-6">
<title>Validation of Annual Consumptions</title>
<p>The annual consumptions are compared at the national, cantonal and municipality levels. Table <xref ref-type="table" rid="T3">3</xref> compares for the year 2008 estimated electricity consumptions and alternative statistics from several sources. As explained in Section &#x0201C;<xref ref-type="sec" rid="S2-4-4">Yearly Demand per Activity and Electric Appliance</xref>,&#x0201D; the estimations of the model give priority to unitary consumptions calibrated on local ESCO bills to take account of regional differences. If such data are not available for the region of interest, average Swiss default values are used. For this reason, the accuracy of the model depends on the level of available information.</p>
<table-wrap position="float" id="T3">
<label>Table 3</label>
<caption><p>Comparison of aggregated yearly demand estimations with other data sources.</p></caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th valign="top" align="left">Territory</th>
<th valign="top" align="center">Measured (TWh)</th>
<th valign="top" align="center">ElectroWhat (TWh)</th>
<th valign="top" align="center">Diff (%)</th>
</tr>
</thead>
<tbody>
<tr>
<td valign="top" align="left"><bold>National level</bold></td>
</tr>
<tr>
<td valign="top" align="left">CH</td>
<td valign="top" align="center">57.42<sup>(i)</sup></td>
<td valign="top" align="center">57.68</td>
<td valign="top" align="center">0.45</td>
</tr>
<tr>
<td valign="top" align="left"><bold>Cantonal level</bold></td>
</tr>
<tr>
<td valign="top" align="left">GE</td>
<td valign="top" align="center">2.851<sup>(ii)</sup></td>
<td valign="top" align="center">2.85</td>
<td valign="top" align="center">&#x02212;0.004</td>
</tr>
<tr>
<td valign="top" align="left">VD</td>
<td valign="top" align="center">3.88<sup>(iii)</sup></td>
<td valign="top" align="center">3.34</td>
<td valign="top" align="center">&#x02212;13.92</td>
</tr>
<tr>
<td valign="top" align="left">ZH</td>
<td valign="top" align="center">9.3<sup>(iv)</sup></td>
<td valign="top" align="center">9.52</td>
<td valign="top" align="center">2.37</td>
</tr>
<tr>
<td valign="top" align="left"><bold>District level</bold></td>
</tr>
<tr>
<td valign="top" align="left">Geneva (BSF No. 6621)</td>
<td valign="top" align="center">1.26<sup>(v)</sup></td>
<td valign="top" align="center">1.33</td>
<td valign="top" align="center">5.56</td>
</tr>
<tr>
<td valign="top" align="left">Russin (BSF No. 6637)</td>
<td valign="top" align="center">0.0013<sup>(v)</sup></td>
<td valign="top" align="center">0.0026</td>
<td valign="top" align="center">96.00</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<p><italic>(i) National demand statistics of Kemmler et al. (<xref ref-type="bibr" rid="B17">2014</xref>); (ii) OCSTAT Table T 08.03.2.01 (OCSTAT, <xref ref-type="bibr" rid="B25">2017</xref>); (iii) Canton Vaud table T08.03.01-A2017 (Canton VD, <xref ref-type="bibr" rid="B7">2017</xref>); (iv) AWEL, Abteilung Energie (AWEL, Abteilung Energie, <xref ref-type="bibr" rid="B3">2014</xref>); (v) Based on SIG issued bills</italic>.</p>
</table-wrap-foot>
</table-wrap>
<p>At the national level, the report of Kemmler et al. (<xref ref-type="bibr" rid="B17">2014</xref>) provides yearly estimations for the main sectors of activity. At this aggregation level there is a very good match showing that the used average Swiss unitary consumptions per activity do not introduce a bias at this level.</p>
<p>Certain cantonal energy offices publish electricity consumption statistics on their home pages. The calibration values of the model for the Canton of Geneva are based on bills issued by the local utility SIG. Therefore, the cantonal aggregated estimated consumption is very close to the actual consumption. For the two other examples of Cantons, bigger differences are observed. The estimation for the Canton of Zurich uses Swiss average default values for all unitary consumptions, since no statistics for unitary consumption per activity are available for this region.</p>
<p>The collaboration with SIG has allowed to access almost all electricity bills of the Canton of Geneva. Comparing actual and estimated electricity demand for each municipality of the Canton Geneva permits to check how accurate the estimation remains when used for smaller territorial units. Figure <xref ref-type="fig" rid="F9">9</xref> plots estimated versus billed electricity demand for the 44 municipalities of the Canton. For the Canton of Geneva, the average difference between actual and estimated demand of a municipality is 16%, with differences ranging from 0.6% (Aire-la-Ville) to 96% (Russin).</p>
<fig position="float" id="F9">
<label>Figure 9</label>
<caption><p>Actual versus estimated electricity consumption for the year 2008 of the 44 municipalities of the Canton of Geneva.</p></caption>
<graphic xlink:href="fbuil-03-00053-g009.tif"/>
</fig>
</sec>
<sec id="S3-9-7">
<title>Validation of Load Curve Profiles</title>
<p>This section compares the estimated load curve with two measured load curves; the first aggregated at the level of the Canton of Geneva and the second at the level of Switzerland. The comparison is done by comparing for each month the estimated and actual load curve representative of an average day. Taking separately for each hour the average demand of all days of the same month permits to compute a load curve representative of an average day. Since a large part of the demand is due to the industry and services sector, working and non-working days are considered separately.</p>
<p>Figure <xref ref-type="fig" rid="F10">10</xref> displays for each month (1&#x02013;12 on the <italic>x</italic>-axis) the average daily load curve in black and the simulated one in gray. The increase of demand in the cold winter months is quite limited since Geneva has almost no electric heating. The simulation replicates the daily shape quite well with morning (11 a.m.) and evening peaks (7 p.m.) due to cooking as well as lighting appliances in the evening. The evening peak is greater due to earlier sunset during winter. For week-ends, the overall load is less because the activity in the services and industry sector is lower; however, the evening peak induced by households becomes more obvious, especially during winter.</p>
<fig position="float" id="F10">
<label>Figure 10</label>
<caption><p>Actual and simulated average hourly load curve from January (1) to December (12) 2008 for the Canton of Geneva.</p></caption>
<graphic xlink:href="fbuil-03-00053-g010.tif"/>
</fig>
<p>Figure <xref ref-type="fig" rid="F11">11</xref> gives the same comparison for the Swiss overall load curve. The measured hourly load curve is estimated by SFOE (<xref ref-type="bibr" rid="B37">2009</xref>) every third Wednesday of each month. It is based on a consolidation of the net production (taking account of imports and exports) of all Swiss electricity producers. An estimated loss of 12% due to transportation and distribution was removed to reflect the final energy used by the end consumer. The main differences are seen for June and July where the model significantly overestimates the demand. At the Swiss level, around 10% of the SH and DHW production (Schneider et al., <xref ref-type="bibr" rid="B35">2016</xref>) is covered by electricity. This explains a seasonal variability with higher demand during the winter months.</p>
<fig position="float" id="F11">
<label>Figure 11</label>
<caption><p>Actual and simulated average hourly load curve from January (1) to December (12) 2008 for Switzerland.</p></caption>
<graphic xlink:href="fbuil-03-00053-g011.tif"/>
</fig>
</sec>
</sec>
<sec id="S3-10">
<title>Electricity Demand Maps and Web Platform</title>
<p>Figure <xref ref-type="fig" rid="F12">12</xref> shows an example of a GIS map combining yearly demand per capita, distribution of demand into four main activity sectors and total demand for some municipalities near the city of Lausanne. A quite high heterogeneity exists among the shares consumed per sector, also influencing the per capita consumption. In the municipalities of Aclens and Mex a large part of the demand is attributable to the services and industry sector, which induces a high demand per capita compared to a residential municipality such as Bussigny. This difference of socio-economic structure influences the distribution of demand into electric appliances and the shape of the load curve.</p>
<fig position="float" id="F12">
<label>Figure 12</label>
<caption><p>Example of electricity consumption map in the surroundings of the city of Lausanne.</p></caption>
<graphic xlink:href="fbuil-03-00053-g012.tif"/>
</fig>
<p>The <italic>Electowhat</italic> model is used to set-up a prototype web platform allowing to explore the consumption specificities of each Swiss municipality. A report containing the main indicators is enriched with charts illustrating the distribution of the yearly demand into activities and electric appliances. This detailed distribution of electric consumption can be downloaded in Excel format for further treatment. A future step will be to include on this platform the experience gained by SIG during the implementation and monitoring of their electricity efficiency program ECO21. The platform will use the decomposed electricity demand provided by the model to help the user to design an efficiency program of ECO21 type in any region of Switzerland.</p>
</sec>
</sec>
<sec id="S4" sec-type="discussion">
<title>Discussion</title>
<sec id="S4-11">
<title>Geo-Dependent Heat Demand</title>
<p>The geo-dependent heat demand model presented in Section &#x0201C;<xref ref-type="sec" rid="S2-3">Geo-Dependent Heat Demand</xref>&#x0201D; is an alternative to commonly used calculation models based on building physics, which suffer from a lack of accuracy when used at large territorial scale, due to the limited available information on the building characteristics. Calibrating the model using measured final energy consumption bears the advantage of replicating the difference in energy demand between buildings with very similar characteristics. An innovative approach consists in using a bootstrap algorithm to compute a confidence interval in addition to the estimated demand of a pixel of territory. These confidence intervals quantify the part of variability the model cannot reproduce, when the specific heat demand <italic>Q<sub>h</sub></italic> of a building is replaced by the average demand of the buildings of same category and age.</p>
<p>There are two important assumptions linked to this kind of approach. The first is that the GWR database contains the majority of the heated buildings of Switzerland. The second is that the samples used to calibrate the bottom-up model are representative. Important deviations from these assumptions would introduce bias in the estimations. One possibility to detect bias is to compare, for example, the aggregate demand of all buildings with other available national scale statistics. As shown in Section &#x0201C;<xref ref-type="sec" rid="S3-6">Heat Demand Statistics Aggregated at the National Level</xref>,&#x0201D; the total aggregated final energy demand for heating is 93.7&#x02009;TWh/year (76.8&#x02009;TWh/year for residential and 16.9&#x02009;TWh/year for mixed use and non-residential buildings). Total demand is in good agreement with an alternative estimation based on national statistics, but significant differences exist when considering the demand of residential and non-residential sectors separately. The main cause for this discrepancy is the differences between the estimations of heated surfaces. Since the <italic>f</italic> <sub>dwell</sub> values of Table <xref ref-type="table" rid="T1">1</xref> are based on a large number of observations, we are quite confident with our larger heated surface estimations for the residential sector. The alternative estimation used for comparison also comes from a model, which is subject to its own uncertainties.</p>
<p>The actual consumption data for buildings contained in the SITG IDC database allows to identify 206 pixels of 200&#x02009;m&#x02009;&#x000D7;&#x02009;200&#x02009;m with known total final energy demand. Estimated demand together with its confidence interval and actual demand are compared for each of these pixels to test the accuracy of the bootstrap algorithm. For three chosen confidence levels &#x003B1;&#x02009;&#x0003D;&#x02009;10, 5, and 1%, the proportion of pixels having their actual energy demand value outside the confidence interval are 15.5, 8.3, and 2.4%, respectively. The fact that these proportions are close to &#x003B1;, show the adequacy of the bootstrap algorithm.</p>
<p>Since retrofit has a major role to play in reducing demand and achieving the goals of the 2050 energy strategy of the Swiss Federal council, it is interesting to challenge the projections made by Prognos (Kirchner et al., <xref ref-type="bibr" rid="B20">2012</xref>). Section &#x0201C;<xref ref-type="sec" rid="S3-8">Impact of Large-scale Retrofit on Heat Demand</xref>&#x0201D; gives an example of how the heat demand model can be used to estimate the achievable heat demand saving potential of the Swiss building stock. For this sake, we relied on previous results (Khoury et al., <xref ref-type="bibr" rid="B19">2016</xref>) concerning the performance gap between the gross and net heat demand savings achieved by building retrofit, which reflects the current retrofit and operation practices. When applying the results of the above mentioned study to our model, we estimate that if the entire Swiss building stock undergoes deep energy retrofit, the gross saving potential for SH would amount to 38.1&#x02009;TWh/year. When taking into account the performance gap, the net saving potential for SH reduces to 18.4&#x02009;TWh/year, i.e., almost half of the gross saving potential. A similar ratio between net and gross saving potential was already observed at a smaller scale in the canton of Geneva. Comparing projected savings for years 2020, 2035, and 2050 with the goals of the energy strategy 2050, we see that even when making optimistic assumptions on retrofit rate and selection of buildings, the net estimated savings remain far from the anticipated targets. This result is based on the assumption that the relation between net and gross saving potential applies to all building categories. Even if the projection of Figure <xref ref-type="fig" rid="F8">8</xref> deserves deeper investigation, this first approximation already raises interesting questions. The projections of Prognos do not take into account the performance gap and may for this reason be too optimistic.</p>
<p>The approach given here has some limitations that are due to data availability. For instance, having an exhaustive GWR register would answer questions concerning possibly missing heated surface. A larger calibration set uniformly covering the entire Swiss territory and all building categories would also increase the accuracy of the model, as well as reducing the size of the confidence intervals.</p>
</sec>
<sec id="S4-12">
<title>Geo-Dependent Electricity Demand</title>
<p>The accuracy of the geo-dependent electricity demand model strongly depends on the detail level of the data available to calibrate the unitary consumptions per activity. This is illustrated in Table <xref ref-type="table" rid="T3">3</xref> that compares the estimated versus actual total aggregated demand for Cantons where local demand data was available&#x02014;or not&#x02014;for calibration. In the case of the Canton of Geneva, detailed consumption per activity is known, leading to representative unitary consumption of this region. In the Canton of Zurich, average Swiss values are used based on national energy consumption surveys for various activities. Although these default values lead to an unbiased estimation at the national level, they cannot replicate in detail the variability that energy demand may have between different regions, within the same activity. This phenomenon is also observed on a smaller scale, as shown in Figure <xref ref-type="fig" rid="F9">9</xref>, showing the errors at the level of each municipality, even when the model is calibrated with accurate Cantonal unitary consumptions. This reflects the fact that electricity demand within a same group of activities has a quite high variance that a large-scale model cannot reproduce.</p>
<p>A second type of validation compares estimated and actual load curves to check if the aggregation of the individual estimated load curves per activity and electric appliance lead to an overall demand, which is close to the average demand of a representative working and non-working day. Again, the added value of having local calibration data available is highlighted by the fact that the model replicates more accurately the demand of the Canton of Geneva than the overall national demand. Unlike the algorithm used for the FORECAST/eLOAD platform, no adaptations are done after the comparison. In our case the validation only serves to check if the load curve library and the weights used to combine the individual load curves reflect the average actual demand. Making further adaptations based on least square difference minimization may lead to completely biased coefficients since the number of degrees of freedom of the model is larger than the number of measured observations. We choose to let the model rely on parameters based on case study measurements and time of use model estimations for household appliances, without making any <italic>a posteriori</italic> adjustments.</p>
<p>It is interesting to observe that the fraction of heat production covered by electricity varies considerably according to the considered region (from 1% for Basel up to 25% for Vallis). This has an effect on the seasonal variation of the electric load curve of the region under consideration. The canton of Geneva has, for example, only a small fraction of electric heating (around 5% of total final energy). Consequently, the seasonal effect is less marked on Figure <xref ref-type="fig" rid="F10">10</xref> than in Figure <xref ref-type="fig" rid="F11">11</xref>, since other regions of Switzerland have higher shares of electric heat production systems.</p>
</sec>
</sec>
<sec id="S5">
<title>Conclusion</title>
<p>Specific approaches are used to estimate geo-dependent heat and electricity demand due to the variety of goals. In the case of heat demand, emphasis is placed on the spatial aspect because heat is more difficult to transport. Modeling electricity demand is more complex, since electricity has many possible uses. To decompose electricity demand per activity and per electric appliances in addition to the spatial characterization provides a big added value. It gives the base input to design electricity efficiency programs considering regional specificities. Further conclusions are given separately for the geo-dependent heat and electricity demand.</p>
<sec id="S5-13">
<title>Geo-Dependent Heat Demand</title>
<p>The proposed bottom-up model operates at the building level and allows heat demand estimations for every geographical aggregation level. It is calibrated using large sets of measured final energy demand. This data was used to compute heat demand statistics per building category and construction period. Basing the model on measured consumptions has the advantage of including the influence of the user. In addition, this approach allows to estimate confidence intervals by means of a bootstrap resampling algorithm. The aggregated overall demand for the entire Swiss territory is in good agreement with national statistics, speaking in favor of the model.</p>
<p>A first outcome of the model is to build a database providing the heat demand for a pixel grid of the entire Swiss territory. As second possible use of the model, is the estimation of expected savings achievable through retrofit (see &#x0201C;<xref ref-type="sec" rid="S3-8">Impact of Large-scale Retrofit on Heat Demand</xref>&#x0201D;). It is interesting to notice that taking account of the performance gap significantly reduces the projected savings (of approximately 50%). This kind of observation was already pointed out by Khoury (<xref ref-type="bibr" rid="B18">2014</xref>) in his study on multi-family residential buildings of the Canton of Geneva. Such discrepancies reveal key questions on some of the energy savings projections made for the 2050 energy strategy of the Swiss Federal council.</p>
</sec>
<sec id="S5-14">
<title>Geo-Dependent Electricity Demand</title>
<p>The used model breaks down the total estimated electricity demand of a municipality into estimated hourly load curves per activity and electric appliance. The University of Geneva, in collaboration with the local utility SIG, is currently updating the model in view of simulating the year 2015. The model&#x02014;today calibrated using the year 2008&#x02014;replicates well the average behavior at large-scale, but of course cannot replicate all local specificities. This is a consequence of the fact that the chosen groups of activities have some heterogeneity concerning the consumption per employee. For example, consider the activity &#x0201C;manufacture of machines and tools,&#x0201D; for which the energy intensity varies a lot depending on the type of manufactured good. Some regions might be more specialized in one or the other type of good, having consequently differences of consumption per employee. The consequence of using Swiss average values for large portions of the Swiss territory is that a part of the variability of demand remains unexplained, as seen in Table <xref ref-type="table" rid="T3">3</xref> and in Figure <xref ref-type="fig" rid="F9">9</xref>.</p>
<p>The comparison of aggregated estimated load curves with actual ones shows that the model replicates the most important seasonal and intraday variations. The present simulation can be done for any geographical level for which the required input variables reflecting socioeconomic activity and building stock are available. By default, the municipality level should be used, since it is the smallest geographical unit having all the required input information easily available at the national scale. This model also opens the perspective of making <italic>ex ante</italic> estimations of savings that could be achieved by standard efficiency measure packages. To this end, in collaboration with the SIG, it is planned to set-up a web-platform helping the user to design an efficiency program similar to ECO21 in any region of Switzerland.</p>
<p>Finally, the results of the geo-dependent heat and electricity models are consolidated with geo-dependent renewable resource data. This database is shared with other research partners and serves as base input to assess energy transition scenarios. Between 2018 and 2020, the second phase of the SCCER FEEB&#x00026;D project (SCCER FEEB&#x00026;D, <xref ref-type="bibr" rid="B33">2017</xref>) will explore how to find the best trade-off between energy efficiency (building retrofit, ECO21 type programs, etc.) and use of renewable resources (PV, geothermal, heat pumps, waste heat, free-cooling, etc.). Such models combined with a consolidated database are the foundation for exploring energy transition pathways and deriving policy recommendations.</p>
</sec>
</sec>
<sec id="S6">
<title>Nomenclature</title>
<table-wrap position="float">
<table frame="hsides" rules="groups">
<tbody>
<tr>
<td valign="top" align="left" colspan="2"><italic><bold>Abbreviations</bold></italic></td>
</tr>
<tr>
<td valign="top" align="left">ECO21</td>
<td valign="top" align="left">Large-scale energy efficiency program launched in 2007 by SIG</td>
</tr>
<tr>
<td valign="top" align="left">EGID</td>
<td valign="top" align="left">Federal building identification number</td>
</tr>
<tr>
<td valign="top" align="left">ESCO</td>
<td valign="top" align="left">Energy service company</td>
</tr>
<tr>
<td valign="top" align="left">DHW</td>
<td valign="top" align="left">Domestic hot water</td>
</tr>
<tr>
<td valign="top" align="left">GEAK</td>
<td valign="top" align="left">Cantonal building energy certificate</td>
</tr>
<tr>
<td valign="top" align="left">GIS</td>
<td valign="top" align="left">Geographical information system</td>
</tr>
<tr>
<td valign="top" align="left">GWR</td>
<td valign="top" align="left">Swiss national building register maintained by the Swiss Federal Statistical Office</td>
</tr>
<tr>
<td valign="top" align="left">NOGA</td>
<td valign="top" align="left">General classification of economic activities, providing a numeric code per activity</td>
</tr>
<tr>
<td valign="top" align="left">SH</td>
<td valign="top" align="left">Space heating</td>
</tr>
<tr>
<td valign="top" align="left">SIG</td>
<td valign="top" align="left">Geneva&#x02019;s energy service company <italic>Services Industriels de Gen&#x000E8;ve</italic></td>
</tr>
<tr>
<td valign="top" align="left">SITG IDC</td>
<td valign="top" align="left">Territorial information system of Geneva&#x02019;s territory, index of heat consumption layer</td>
</tr>
<tr>
<td valign="top" align="left">SOAP</td>
<td valign="top" align="left">Simple object access protocol</td>
</tr>
<tr>
<td valign="top" align="left" colspan="2"><italic><bold>Latin symbols</bold></italic></td>
</tr>
<tr>
<td valign="top" align="left"><italic>A<sub>E</sub></italic></td>
<td valign="top" align="left">Heated surface or energy reference surface defined by standard SIA 416/1 (m<sup>2</sup>)</td>
</tr>
<tr>
<td valign="top" align="left"><italic>A</italic><sub>dwelling</sub></td>
<td valign="top" align="left">Total surface of all residential dwelling of a buildings (m<sup>2</sup>)</td>
</tr>
<tr>
<td valign="top" align="left"><italic>A</italic><sub>gross</sub></td>
<td valign="top" align="left">Gross building surface as ground surface multiplied by the number of floors (m<sup>2</sup>)</td>
</tr>
<tr>
<td valign="top" align="left"><italic>A</italic><sub>th</sub></td>
<td valign="top" align="left">Surface of the building thermal envelope (m<sup>2</sup>)</td>
</tr>
<tr>
<td valign="top" align="left">&#x00394;<italic>A<sub>E</sub></italic></td>
<td valign="top" align="left">Relative error between estimated and actual <italic>A<sub>E</sub></italic> (-)</td>
</tr>
<tr>
<td valign="top" align="left">DD(<italic>l</italic>)</td>
<td valign="top" align="left">Degree day of geographical location <italic>l</italic> (K&#x0016F;day)</td>
</tr>
<tr>
<td valign="top" align="left"><italic>E</italic></td>
<td valign="top" align="left">Final energy demand per m<sup>2</sup> for SH and DHW production (MJ/m<sup>2</sup>/year)</td>
</tr>
<tr>
<td valign="top" align="left"><italic>ES</italic><sub>Net</sub></td>
<td valign="top" align="left">Net final energy saving potential for SH after retrofit (MJ/year)</td>
</tr>
<tr>
<td valign="top" align="left"><italic>F</italic>(<italic>L</italic>)</td>
<td valign="top" align="left">Fraction of electric devices actually in operation having efficiency label <italic>L</italic> (%)</td>
</tr>
<tr>
<td valign="top" align="left"><italic>g</italic></td>
<td valign="top" align="left">Solar energy transmittance of glass windows (%)</td>
</tr>
<tr>
<td valign="top" align="left"><italic>Q</italic><sub>SH</sub></td>
<td valign="top" align="left">Useful energy demand per m<sup>2</sup> for SH (MJ/m<sup>2</sup>/year)</td>
</tr>
<tr>
<td valign="top" align="left"><italic>Q</italic><sub>SH,lim</sub></td>
<td valign="top" align="left">Upper limit of calculated useful energy demand per m<sup>2</sup> for SH according to standard SIA 380/1 (MJ/m<sup>2</sup>/year)</td>
</tr>
<tr>
<td valign="top" align="left"><italic>Q</italic><sub>SH,AR</sub></td>
<td valign="top" align="left">Useful energy demand per m<sup>2</sup> for SH after retrofit (MJ/m<sup>2</sup>/year)</td>
</tr>
<tr>
<td valign="top" align="left"><italic>Q</italic><sub>DHW</sub></td>
<td valign="top" align="left">Useful energy demand per m<sup>2</sup> for DHW (MJ/m<sup>2</sup>/year)</td>
</tr>
<tr>
<td valign="top" align="left"><italic>QS</italic><sub>Gross</sub></td>
<td valign="top" align="left">Gross useful energy saving potential per m<sup>2</sup> for SH after retrofit (MJ/m<sup>2</sup>/year)</td>
</tr>
<tr>
<td valign="top" align="left"><italic>QS</italic><sub>Net</sub></td>
<td valign="top" align="left">Net useful energy saving potential per m<sup>2</sup> for SH after retrofit (MJ/m<sup>2</sup>/year)</td>
</tr>
<tr>
<td valign="top" align="left"><italic>U</italic></td>
<td valign="top" align="left">Thermal transmittance of a building&#x02019;s envelope component (W/m<sup>2</sup>&#x0016F;K)</td>
</tr>
<tr>
<td valign="top" align="left">SE<italic><sub>B</sub></italic></td>
<td valign="top" align="left">Final energy for SH and DHW production for a building (MJ/year)</td>
</tr>
<tr>
<td valign="top" align="left">SE<sub>CH</sub></td>
<td valign="top" align="left">Final energy for SH and DHW production for the Swiss building stock (TWh/year)</td>
</tr>
<tr>
<td valign="top" align="left"><inline-formula><mml:math id="M37"><mml:mover accent='true'><mml:mi>X</mml:mi><mml:mo>&#x000AF;</mml:mo></mml:mover></mml:math></inline-formula></td>
<td valign="top" align="left">Average value of variable X. For example <inline-formula><mml:math id="M38"><mml:mover accent="false" class="mml-overline"><mml:mrow><mml:msub><mml:mrow><mml:mi>Q</mml:mi></mml:mrow><mml:mrow><mml:mtext>SH</mml:mtext></mml:mrow></mml:msub></mml:mrow><mml:mo accent="true">&#x000AF;</mml:mo></mml:mover></mml:math></inline-formula> is the average useful energy demand for SH of a given building category</td>
</tr>
<tr>
<td valign="top" align="left"><inline-formula><mml:math id="M39"><mml:mover accent='true'><mml:mi>X</mml:mi><mml:mo>&#x0005E;</mml:mo></mml:mover></mml:math></inline-formula></td>
<td valign="top" align="left">Estimated value of variable X. For example <inline-formula><mml:math id="M40"><mml:mover accent='true'><mml:mi>E</mml:mi><mml:mo>&#x0005E;</mml:mo></mml:mover></mml:math></inline-formula> is the estimated final energy demand for SH and DHW production</td>
</tr>
<tr>
<td valign="top" align="left">YC</td>
<td valign="top" align="left">Yearly electric consumption of an electric device (kWh/year)</td>
</tr>
<tr>
<td valign="top" align="left" colspan="2"><italic><bold>Greek symbols</bold></italic></td>
</tr>
<tr>
<td valign="top" align="left">&#x003B7;<sub>EC</sub></td>
<td valign="top" align="left">Efficiency of energy conversion system</td>
</tr>
</tbody>
</table>
</table-wrap>
</sec>
<sec id="S7">
<title>Author Contributions</title>
<p>SS and PH are the main contributors of the methods described in section &#x0201C;Geo-Dependent Heat Demand.&#x0201D; JK and BL contribute to section &#x0201C;Impact of Large-scale Retrofit on Heat Demand.&#x0201D; PS and SS are the main contributors of the methods described in section &#x0201C;Geo-Dependent Electricity Demand.&#x0201D; MP provided the access to the GEAK database. SS wrote the manuscript.</p>
</sec>
<sec id="S8">
<title>Conflict of Interest Statement</title>
<p>The author declares that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
</body>
<back>
<ack>
<p>This research is part of the activities of SCCER FEEB&#x00026;D, which is financially supported by the Swiss Commission for Technology and Innovation (CTI). The authors thanks the Swiss Federal Statistical Office for the free access to the GWR database.</p>
</ack>
<ref-list>
<title>References</title>
<ref id="B1"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Assouline</surname> <given-names>D.</given-names></name> <name><surname>Mohajeri</surname> <given-names>N.</given-names></name> <name><surname>Scartezzini</surname> <given-names>J.-L.</given-names></name></person-group> (<year>2015</year>). <source>A Machine Learning Methodology for Estimating Roof-top Photovoltaic Solar Energy Potential in Switzerland</source>.<pub-id pub-id-type="doi">10.5075/epfl-cisbat2015-555-560</pub-id></citation></ref>
<ref id="B2"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Assouline</surname> <given-names>D.</given-names></name> <name><surname>Mohajeri</surname> <given-names>N.</given-names></name> <name><surname>Scartezzini</surname> <given-names>J.-L.</given-names></name></person-group> (<year>2017</year>). <article-title>Quantifying rooftop photovoltaic solar energy potential: a machine learning approach</article-title>. <source>Solar Energy</source> <volume>141</volume>, <fpage>278</fpage>&#x02013;<lpage>296</lpage>.<pub-id pub-id-type="doi">10.1016/j.solener.2016.11.045</pub-id></citation></ref>
<ref id="B3"><citation citation-type="book"><collab>AWEL, Abteilung Energie</collab>. (<year>2014</year>). <source>Energieplanungsbericht 2013, Bericht Des Regierungsrats &#x000DC;ber Die Energieplanung Des Kantons Z&#x000FC;rich</source>. <publisher-loc>Z&#x000FC;rich</publisher-loc>: <publisher-name>AWEL, Abteilung Energie</publisher-name>. Available at: <uri xlink:href="http://www.energie.zh.ch">www.energie.zh.ch</uri></citation></ref>
<ref id="B4"><citation citation-type="book"><person-group person-group-type="author"><name><surname>Bendel</surname> <given-names>R.</given-names></name> <name><surname>Brunner</surname> <given-names>F.</given-names></name> <name><surname>Ferster</surname> <given-names>M.</given-names></name></person-group> (<year>2011</year>). <source>Energieverbrauch in Der Industrie Und Im Dienstleistungssektor, Resultate 2010</source>. <publisher-name>Helbling Beratung &#x0002B; Bauplanung AG</publisher-name>.</citation></ref>
<ref id="B5"><citation citation-type="book"><collab>BFE</collab>. (<year>2016</year>). <source>Statistique Globale Suisse De L&#x02019;&#x000E9;nergie 2015</source>. <publisher-loc>Bern</publisher-loc>: <publisher-name>Bundesamt f&#x000FC;r Energie</publisher-name>.</citation></ref>
<ref id="B6"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Cabrera</surname> <given-names>D.</given-names></name> <name><surname>Seal</surname> <given-names>T.</given-names></name> <name><surname>Bertholet</surname> <given-names>J.-L.</given-names></name> <name><surname>Lachal</surname> <given-names>B.</given-names></name> <name><surname>Jeanneret</surname> <given-names>C.</given-names></name></person-group> (<year>2012</year>). <article-title>Evaluation of energy efficiency program in Geneva: evaluation methodology and experience feedback for two subprograms using bottom-up approach</article-title>. <source>Energy Effic.</source> <volume>5</volume>, <fpage>87</fpage>&#x02013;<lpage>96</lpage>.<pub-id pub-id-type="doi">10.1007/s12053-011-9110-1</pub-id></citation></ref>
<ref id="B7"><citation citation-type="web"><person-group person-group-type="author"><name><surname>Canton</surname> <given-names>VD.</given-names></name></person-group> (<year>2017</year>). <article-title>&#x0201C;Statistique Vaud,&#x0201D;</article-title> in <source>Estimation De La Consommation Finale D&#x02019;&#x000E9;nergie, Par Agent &#x000C9;nerg&#x000E9;tique, En TJ, Vaud, 1996&#x02013;2015</source>. Available at: <uri xlink:href="http://www.scris.vd.ch/Default.aspx?DocID=1197&#x00026;DomId=2211">http://www.scris.vd.ch/Default.aspx?DocID&#x0003D;1197&#x00026;DomId&#x0003D;2211</uri></citation></ref>
<ref id="B8"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Connolly</surname> <given-names>D.</given-names></name> <name><surname>Lund</surname> <given-names>H.</given-names></name> <name><surname>Mathiesen</surname> <given-names>B. V.</given-names></name> <name><surname>Werner</surname> <given-names>S.</given-names></name> <name><surname>M&#x000F6;ller</surname> <given-names>B.</given-names></name> <name><surname>Persson</surname> <given-names>U.</given-names></name> <etal/></person-group> (<year>2013</year>). <article-title>Heat roadmap Europe: combining district heating with heat savings to decarbonise the EU energy system</article-title>. <source>Energy Policy</source> <volume>65</volume>, <fpage>475</fpage>&#x02013;<lpage>489</lpage>.<pub-id pub-id-type="doi">10.1016/j.enpol.2013.10.035</pub-id></citation></ref>
<ref id="B9"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>David</surname> <given-names>A.</given-names></name> <name><surname>Mathiesen</surname> <given-names>B. V.</given-names></name> <name><surname>Averfalk</surname> <given-names>H.</given-names></name> <name><surname>Werner</surname> <given-names>S.</given-names></name> <name><surname>Lund</surname> <given-names>H.</given-names></name></person-group> (<year>2017</year>). <article-title>Heat roadmap Europe: large-scale electric heat pumps in district heating systems</article-title>. <source>Energies</source> <volume>10</volume>, <fpage>578</fpage>.<pub-id pub-id-type="doi">10.3390/en10040578</pub-id></citation></ref>
<ref id="B10"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>De Wilde</surname> <given-names>P.</given-names></name></person-group> (<year>2014</year>). <article-title>The gap between predicted and measured energy performance of buildings: a framework for investigation</article-title>. <source>Autom. Constr.</source> <volume>41</volume>, <fpage>40</fpage>&#x02013;<lpage>49</lpage>.<pub-id pub-id-type="doi">10.1016/j.autcon.2014.02.009</pub-id></citation></ref>
<ref id="B11"><citation citation-type="book"><collab>EAE</collab>. (<year>2009</year>). <source>Verkaufszahlenbasierte Energieeffizienzanalyse Von Elektroger&#x000E4;tenSI/40017</source>. <publisher-name>Energie agentur electroger&#x000E4;te(EAE)</publisher-name>. Available at: <uri xlink:href="https://www.eae-geraete.ch/effizienzanalyse/">https://www.eae-geraete.ch/effizienzanalyse/</uri></citation></ref>
<ref id="B12"><citation citation-type="book"><person-group person-group-type="author"><name><surname>Efron</surname> <given-names>B.</given-names></name> <name><surname>Tibshirani</surname> <given-names>R.</given-names></name></person-group> (<year>1993</year>). <source>An Introduction to the Bootstrap. Monographs on Statistics and Applied Probability 57</source>. <publisher-loc>New York</publisher-loc>: <publisher-name>Chapman &#x00026; Hall</publisher-name>.</citation></ref>
<ref id="B13"><citation citation-type="book"><person-group person-group-type="author"><name><surname>Eicher</surname> <given-names>H.</given-names></name> <name><surname>Pauli</surname> <given-names>H.</given-names></name> <name><surname>Erb</surname> <given-names>M.</given-names></name> <name><surname>Gutzwiller</surname> <given-names>S.</given-names></name></person-group> (<year>2011</year>). <source>Ausbau Von WKK in Der Schweiz WKK-Standortevaluation Auf Basis Einer GIS-Analyse</source>. <publisher-loc>Liestal</publisher-loc>: <publisher-name>Dr. Eicher&#x0002B;Pauli AG planer f&#x000FC;r Energie und Geb&#x000E4;ude Technik</publisher-name>.</citation></ref>
<ref id="B14"><citation citation-type="book"><person-group person-group-type="author"><name><surname>Eicher</surname> <given-names>H.</given-names></name> <name><surname>Pauli</surname> <given-names>H.</given-names></name> <name><surname>Sres</surname> <given-names>A.</given-names></name> <name><surname>Nussbaumer</surname> <given-names>B.</given-names></name></person-group> (<year>2014</year>). <source>Weissbuch Fernw&#x000E4;rme Schweiz &#x02013; VFS Strategie, Langfristperspektiven F&#x000FC;r Erneuerbare Und Energieeffiziente Nah- Und Fernw&#x000E4;rme in Der Schweiz</source>. <publisher-loc>Liestal</publisher-loc>: <publisher-name>Dr. Eicher&#x0002B;Pauli AG planer f&#x000FC;r Energie und Geb&#x000E4;ude Technik</publisher-name>.</citation></ref>
<ref id="B15"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Grandjean</surname> <given-names>A.</given-names></name> <name><surname>Adnot</surname> <given-names>J.</given-names></name> <name><surname>Binet</surname> <given-names>G.</given-names></name></person-group> (<year>2012</year>). <article-title>A review and an analysis of the residential electric load curve models</article-title>. <source>Renew. Sustain. Energ. Rev.</source> <volume>16</volume>, <fpage>6539</fpage>&#x02013;<lpage>6565</lpage>.<pub-id pub-id-type="doi">10.1016/j.rser.2012.08.013</pub-id></citation></ref>
<ref id="B16"><citation citation-type="confproc"><person-group person-group-type="author"><name><surname>Jakob</surname> <given-names>M.</given-names></name> <name><surname>Kallio</surname> <given-names>S.</given-names></name> <name><surname>Bossmann</surname> <given-names>T.</given-names></name></person-group> (<year>2014</year>). <article-title>&#x0201C;Generating Electricity Demand-Side Load Profiles of the Tertiary Sector for Selected European Countries,&#x0201D;</article-title> in <conf-name>Proceedings of 8th International Conference Improving Energy Efficiency in Commercial Buildings (IEECB&#x02019;14)</conf-name>, <conf-loc>Frankfurt</conf-loc>.<pub-id pub-id-type="doi">10.2790/32838</pub-id></citation></ref>
<ref id="B17"><citation citation-type="book"><person-group person-group-type="author"><name><surname>Kemmler</surname> <given-names>A.</given-names></name> <name><surname>Pi&#x000E9;gsa</surname> <given-names>A.</given-names></name> <name><surname>Ley</surname> <given-names>A.</given-names></name> <name><surname>W&#x000FC;thrich</surname> <given-names>P.</given-names></name> <name><surname>Keller</surname> <given-names>M.</given-names></name> <name><surname>Jakob</surname> <given-names>M.</given-names></name> <etal/></person-group> (<year>2014</year>). <source>Analyse Des Schweizerischen Energieverbrauchs 2000&#x02013;2013 Nach Verwendungszwecken</source>. <publisher-loc>Bern</publisher-loc>: <publisher-name>Bundesamt f&#x000FC;r Energie</publisher-name>.</citation></ref>
<ref id="B18"><citation citation-type="book"><person-group person-group-type="author"><name><surname>Khoury</surname> <given-names>J.</given-names></name></person-group> (<year>2014</year>). <source>R&#x000E9;novation &#x000C9;nerg&#x000E9;tique Des B&#x000E2;timents R&#x000E9;sidentiels Collectifs: &#x000C9;tat Des Lieux, Retours D&#x02019;exp&#x000E9;rience Et Potentiels Du Parc Genevois</source>. <publisher-name>Universit&#x000E9; de Gen&#x000E8;ve</publisher-name>, th&#x000E8;se de doctorat No 4752, direction Bernard Lachal. Available at: <uri xlink:href="http://archive-ouverte.unige.ch/unige:48085">http://archive-ouverte.unige.ch/unige:48085</uri></citation></ref>
<ref id="B19"><citation citation-type="book"><person-group person-group-type="author"><name><surname>Khoury</surname> <given-names>J.</given-names></name> <name><surname>Hollmuller</surname> <given-names>P.</given-names></name> <name><surname>Lachal</surname> <given-names>B. M.</given-names></name></person-group> (<year>2016</year>). <article-title>&#x0201C;Energy performance gap in building retrofit: characterization and effect on the energy saving potential,&#x0201D;</article-title> in <source>19. Status-Seminar</source> (<publisher-loc>Zurich</publisher-loc>: <publisher-name>ETHZ</publisher-name>). Available at: <uri xlink:href="http://archive-ouverte.unige.ch/unige:86086">http://archive-ouverte.unige.ch/unige:86086</uri></citation></ref>
<ref id="B20"><citation citation-type="book"><person-group person-group-type="author"><name><surname>Kirchner</surname> <given-names>A.</given-names></name> <name><surname>Bredow</surname> <given-names>D.</given-names></name> <name><surname>Ess</surname> <given-names>F.</given-names></name></person-group> (<year>2012</year>). <source>Die Energie Perpectiven F&#x000FC;r Die Schweiz by 2050</source>. <publisher-loc>Basel</publisher-loc>: <publisher-name>Prognos AG</publisher-name>.</citation></ref>
<ref id="B21"><citation citation-type="book"><person-group person-group-type="author"><name><surname>Le Strat</surname> <given-names>P.</given-names></name></person-group> (<year>2008</year>). <source>Analyse De La Demande D&#x02019;&#x000E9;lectricit&#x000E9; Du Canton De Gen&#x000E8;ve499 937 605 00016</source>. <publisher-loc>Bures sur Yvette, France</publisher-loc>: <publisher-name>Action &#x000E9;nergies</publisher-name>.</citation></ref>
<ref id="B22"><citation citation-type="book"><person-group person-group-type="author"><name><surname>Le Strat</surname> <given-names>P.</given-names></name></person-group> (<year>2011</year>). <source>Programme EOSh De Ma&#x000EE;trise De La Demande d&#x02019;Electricit&#x000E9;517 421 202 00014</source>. <publisher-loc>La Baule, France</publisher-loc>: <publisher-name>APOGEE</publisher-name>.</citation></ref>
<ref id="B23"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Marszal-Pomianowska</surname> <given-names>A.</given-names></name> <name><surname>Heiselberg</surname> <given-names>P.</given-names></name> <name><surname>Kalyanova Larsen</surname> <given-names>O.</given-names></name></person-group> (<year>2016</year>). <article-title>Household electricity demand profiles &#x02013; a high-resolution load model to facilitate modelling of energy flexible buildings</article-title>. <source>Energy</source> <volume>103</volume>, <fpage>487</fpage>&#x02013;<lpage>501</lpage>.<pub-id pub-id-type="doi">10.1016/j.energy.2016.02.159</pub-id></citation></ref>
<ref id="B24"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mavromatidis</surname> <given-names>G.</given-names></name> <name><surname>Orehounig</surname> <given-names>K.</given-names></name> <name><surname>Richner</surname> <given-names>P.</given-names></name> <name><surname>Carmeliet</surname> <given-names>J.</given-names></name></person-group> (<year>2016</year>). <article-title>A strategy for reducing CO<sub>2</sub> emissions from buildings with the Kaya identity &#x02013; a Swiss energy system analysis and a case study</article-title>. <source>Energy Policy</source> <volume>88</volume>, <fpage>343</fpage>&#x02013;<lpage>354</lpage>.<pub-id pub-id-type="doi">10.1016/j.enpol.2015.10.037</pub-id></citation></ref>
<ref id="B25"><citation citation-type="book"><collab>OCSTAT</collab>. (<year>2017</year>). <source>Statistiques Cantonales Gen&#x000E8;ve (OCSTAT)</source>. <publisher-name>Statistiques Cantonales, Electricit&#x000E9;</publisher-name>. Available at: <uri xlink:href="http://www.ge.ch/statistique/domaines/08/08_02/tableaux.asp#3">http://www.ge.ch/statistique/domaines/08/08_02/tableaux.asp&#x00023;3</uri></citation></ref>
<ref id="B26"><citation citation-type="book"><collab>OFS</collab>. (<year>2014a</year>). <source>Eidgen&#x000F6;ssisches Geb&#x000E4;ude- Und Wohnungsregister,Web Services,Technisches Dossier Zum Datenaustausch via WebServices</source>. <publisher-loc>Neuch&#x000E2;tel</publisher-loc>: <publisher-name>Bundesamt f&#x000FC;r Statistik BFS</publisher-name>.</citation></ref>
<ref id="B27"><citation citation-type="book"><collab>OFS</collab>. (<year>2014b</year>). <source>Erhebungen, Quellen &#x02013; Unternehmensstatistik (STATENT)</source>. <publisher-name>Office f&#x000E9;d&#x000E9;rals de la Statistique</publisher-name>. Available at: <uri xlink:href="http://www.bfs.admin.ch/bfs/portal/de/index/infothek/erhebungen__quellen/blank/blank/statent/01.html">http://www.bfs.admin.ch/bfs/portal/de/index/infothek/erhebungen__quellen/blank/blank/statent/01.html</uri></citation></ref>
<ref id="B28"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Orehounig</surname> <given-names>K.</given-names></name> <name><surname>Mavromatidis</surname> <given-names>G.</given-names></name> <name><surname>Evins</surname> <given-names>R.</given-names></name> <name><surname>Dorer</surname> <given-names>V.</given-names></name> <name><surname>Carmeliet</surname> <given-names>J.</given-names></name></person-group> (<year>2014</year>). <article-title>Towards an energy sustainable community: an energy system analysis for a village in Switzerland</article-title>. <source>Energy Build.</source> <volume>84</volume>, <fpage>277</fpage>&#x02013;<lpage>286</lpage>.<pub-id pub-id-type="doi">10.1016/j.enbuild.2014.08.012</pub-id></citation></ref>
<ref id="B29"><citation citation-type="confproc"><person-group person-group-type="author"><name><surname>Perez</surname> <given-names>D.</given-names></name> <name><surname>K&#x000E4;mpf</surname> <given-names>J. H.</given-names></name> <name><surname>Wilke</surname> <given-names>U.</given-names></name> <name><surname>Papadopoulou</surname> <given-names>M.</given-names></name> <name><surname>Robinson</surname> <given-names>D.</given-names></name></person-group> (<year>2011</year>). <article-title>&#x0201C;CitySimsimulation: the case study of Alt-Wiedikon, a neighbourhood of Z&#x000FC;rich city,&#x0201D;</article-title> in <conf-name>Proceedings of CISBAT 2011 &#x02013; CleanTech for Sustainable Buildings</conf-name>, <conf-loc>Lausanne</conf-loc>.</citation></ref>
<ref id="B30"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Persson</surname> <given-names>U.</given-names></name> <name><surname>M&#x000F6;ller</surname> <given-names>B.</given-names></name> <name><surname>Werner</surname> <given-names>S.</given-names></name></person-group> (<year>2014</year>). <article-title>Heat roadmap Europe: identifying strategic heat synergy regions</article-title>. <source>Energy Policy</source> <volume>74</volume>, <fpage>663</fpage>&#x02013;<lpage>681</lpage>.<pub-id pub-id-type="doi">10.1016/j.enpol.2014.07.015</pub-id></citation></ref>
<ref id="B31"><citation citation-type="book"><person-group person-group-type="author"><name><surname>Quiquerez</surname> <given-names>L.</given-names></name> <name><surname>Faessler</surname> <given-names>J.</given-names></name> <name><surname>Lachal</surname> <given-names>B. M.</given-names></name> <name><surname>Mermoud</surname> <given-names>F.</given-names></name> <name><surname>Hollmuller</surname> <given-names>P.</given-names></name></person-group> (<year>2015</year>). <source>GIS Methodology and Case Study Regarding Assessment of the Solar Potential at Territorial Level: PV or Thermal?</source> <publisher-loc>Aalborg University Press</publisher-loc>. Available at: <uri xlink:href="http://journals.aau.dk/index.php/sepm/article/view/1043">http://journals.aau.dk/index.php/sepm/article/view/1043</uri></citation></ref>
<ref id="B32"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Saner</surname> <given-names>D.</given-names></name> <name><surname>Vadenbo</surname> <given-names>C.</given-names></name> <name><surname>Steubing</surname> <given-names>B.</given-names></name> <name><surname>Hellweg</surname> <given-names>S.</given-names></name></person-group> (<year>2014</year>). <article-title>Regionalized LCA-based optimization of building energy supply: method and case study for a Swiss municipality</article-title>. <source>Environ. Sci. Technol.</source> <volume>48</volume>, <fpage>7651</fpage>&#x02013;<lpage>7659</lpage>.<pub-id pub-id-type="doi">10.1021/es500151q</pub-id><pub-id pub-id-type="pmid">24865977</pub-id></citation></ref>
<ref id="B33"><citation citation-type="web"><collab>SCCER FEEB&#x00026;D</collab>. (<year>2017</year>). <source>SCCER Future Energy Efficient Buildings &#x00026; Districts</source>. Available at: <uri xlink:href="https://www.sccer-feebd.ch/">https://www.sccer-feebd.ch/</uri></citation></ref>
<ref id="B34"><citation citation-type="web"><person-group person-group-type="author"><name><surname>Schneider</surname> <given-names>S.</given-names></name> <name><surname>Assouline</surname> <given-names>D.</given-names></name> <name><surname>Mohajeri</surname> <given-names>N.</given-names></name> <name><surname>Scartezzini</surname> <given-names>J.-L.</given-names></name></person-group> (<year>2015</year>). <source>Geo-Dependent Energy Demand and Supply Web-Service</source>. Available at: <uri xlink:href="http://wisesccer1.unige.ch/">http://wisesccer1.unige.ch/</uri></citation></ref>
<ref id="B35"><citation citation-type="confproc"><person-group person-group-type="author"><name><surname>Schneider</surname> <given-names>S.</given-names></name> <name><surname>Khoury</surname> <given-names>J.</given-names></name> <name><surname>Lachal</surname> <given-names>B.</given-names></name> <name><surname>Hollmuller</surname> <given-names>P.</given-names></name></person-group> (<year>2016</year>). <article-title>&#x0201C;Geo-dependent heat demand model of the Swiss building stock,&#x0201D;</article-title> in <conf-name>Sustainable Built Environment Regional Conference. SBE 2016</conf-name>, <edition>17th Edn</edition> (<conf-loc>Zurich</conf-loc>: <conf-sponsor>SBE</conf-sponsor>). Available at: <uri xlink:href="https://archive-ouverte.unige.ch/unige:84240">https://archive-ouverte.unige.ch/unige:84240</uri>.</citation></ref>
<ref id="B36"><citation citation-type="confproc"><person-group person-group-type="author"><name><surname>Schneider</surname> <given-names>S.</given-names></name> <name><surname>Le Strat</surname> <given-names>P.</given-names></name> <name><surname>Patel</surname> <given-names>M.</given-names></name></person-group> (<year>2017</year>). <article-title>&#x0201C;<italic>Electro what: a platform for territorial analysis of the electricity consumption</italic>,&#x0201D;</article-title> in <conf-name>Proceedings of CISBAT 2017</conf-name>, <conf-loc>Lausanne, Switzerland</conf-loc>: <conf-sponsor>EPFL</conf-sponsor>.<pub-id pub-id-type="doi">10.1016/j.egypro.2017.07.376</pub-id></citation></ref>
<ref id="B37"><citation citation-type="book"><collab>SFOE</collab>. (<year>2009</year>). <source>Schweizerische Elektrizit&#x000E4;tsstatistik 2008 Report: 805.005.08.d</source>. <publisher-loc>Ittigen</publisher-loc>.</citation></ref>
<ref id="B38"><citation citation-type="book"><collab>SIA</collab>. (<year>2009</year>). <source>Norme SIA 380/1:2009. L&#x02019;&#x000E9;nergie Thermique Dans Le B&#x000E2;timent</source>. <publisher-loc>Zurich</publisher-loc>: <publisher-name>Soci&#x000E9;t&#x000E9; suisse des ing&#x000E9;nieurs et des architectes (SIA)</publisher-name>.</citation></ref>
<ref id="B39"><citation citation-type="book"><collab>SIA</collab>. (<year>2010</year>). <source>Norme SIA 2028: Donn&#x000E9;es Climatiques Pour La Physique Du B&#x000E2;timent, L&#x02019;&#x000E9;nergie Et Les Installations Du B&#x000E2;timent</source>. <publisher-loc>Zurich</publisher-loc>: <publisher-name>Soci&#x000E9;t&#x000E9; suisse des ing&#x000E9;nieurs et des architectes</publisher-name>.</citation></ref>
<ref id="B40"><citation citation-type="book"><collab>SIA</collab>. (<year>2015</year>). <source>Norme SIA 2024: Donn&#x000E9;es D&#x02019;utilisation Des Locaux Pour L&#x02019;&#x000E9;nergie Et Les Installations Du B&#x000E2;timent</source>. <publisher-loc>Zurich</publisher-loc>: <publisher-name>Soci&#x000E9;t&#x000E9; suisse des ing&#x000E9;nieurs et des architectes</publisher-name>.</citation></ref>
<ref id="B41"><citation citation-type="book"><collab>SIA</collab>. (<year>2016</year>). <source>Norme SIA 2031: Certificat &#x000C9;nerg&#x000E9;tique Des B&#x000E2;timents</source>. <publisher-loc>Zurich</publisher-loc>: <publisher-name>Soci&#x000E9;t&#x000E9; suisse des ing&#x000E9;nieurs et des architectes</publisher-name>.</citation></ref>
<ref id="B42"><citation citation-type="web"><collab>SITG</collab>. (<year>2015</year>). <source>SITG Indice De D&#x000E9;pense De Chaleur (IDC) Des B&#x000E2;timents (LEn &#x0003E; 5.8.2010) &#x02013; Moyenne Sur 2 Ou 3 Ans</source>. Available at: <uri xlink:href="http://ge.ch/sitg/sitg_catalog/sitg_donnees/i?keyword=IDC">http://ge.ch/sitg/sitg_catalog/sitg_donnees/i?keyword&#x0003D;IDC</uri></citation></ref>
<ref id="B43"><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Swan</surname> <given-names>L. G.</given-names></name> <name><surname>Ugursal</surname> <given-names>V. I.</given-names></name></person-group> (<year>2009</year>). <article-title>Modeling of end-use energy consumption in the residential sector: a review of modeling techniques</article-title>. <source>Renew. Sustain. Energ. Rev.</source> <volume>13</volume>, <fpage>1819</fpage>&#x02013;<lpage>1835</lpage>.<pub-id pub-id-type="doi">10.1016/j.rser.2008.09.033</pub-id></citation></ref>
<ref id="B44"><citation citation-type="web"><collab>Swiss Topo</collab>. (<year>2015</year>). <source>Swiss Topo Topographic Landscape Model TLM</source>. Available at: <uri xlink:href="https://www.swisstopo.admin.ch/de/wissen-fakten/topografisches-landschaftsmodell.html">https://www.swisstopo.admin.ch/de/wissen-fakten/topografisches-landschaftsmodell.html</uri></citation></ref>
</ref-list>
</back>
</article>