<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3-mathml3.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:ali="http://www.niso.org/schemas/ali/1.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" article-type="research-article" dtd-version="1.3" xml:lang="EN">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Bioeng. Biotechnol.</journal-id>
<journal-title-group>
<journal-title>Frontiers in Bioengineering and Biotechnology</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Bioeng. Biotechnol.</abbrev-journal-title>
</journal-title-group>
<issn pub-type="epub">2296-4185</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">1658728</article-id>
<article-id pub-id-type="doi">10.3389/fbioe.2025.1658728</article-id>
<article-version article-version-type="Version of Record" vocab="NISO-RP-8-2008"/>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Original Research</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Is an additional cannulated screw necessary for unstable femoral neck fractures with comminuted posteromedial cortex by femoral neck system (FNS) fixation? a biomechanical and clinical study</article-title>
<alt-title alt-title-type="left-running-head">Fan et al.</alt-title>
<alt-title alt-title-type="right-running-head">
<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3389/fbioe.2025.1658728">10.3389/fbioe.2025.1658728</ext-link>
</alt-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" equal-contrib="yes">
<name>
<surname>Fan</surname>
<given-names>Jixing</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<xref ref-type="author-notes" rid="fn001">
<sup>&#x2020;</sup>
</xref>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Data curation" vocab-term-identifier="https://credit.niso.org/contributor-roles/data-curation/">Data curation</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="methodology" vocab-term-identifier="https://credit.niso.org/contributor-roles/methodology/">Methodology</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="software" vocab-term-identifier="https://credit.niso.org/contributor-roles/software/">Software</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; original draft" vocab-term-identifier="https://credit.niso.org/contributor-roles/writing-original-draft/">Writing &#x2013; original draft</role>
</contrib>
<contrib contrib-type="author" equal-contrib="yes">
<name>
<surname>Hao</surname>
<given-names>Youliang</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<xref ref-type="author-notes" rid="fn001">
<sup>&#x2020;</sup>
</xref>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Data curation" vocab-term-identifier="https://credit.niso.org/contributor-roles/data-curation/">Data curation</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="software" vocab-term-identifier="https://credit.niso.org/contributor-roles/software/">Software</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; review &amp; editing" vocab-term-identifier="https://credit.niso.org/contributor-roles/writing-review-editing/">Writing &#x2013; review &amp; editing</role>
</contrib>
<contrib contrib-type="author" equal-contrib="yes">
<name>
<surname>Cao</surname>
<given-names>Yuan</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<xref ref-type="author-notes" rid="fn001">
<sup>&#x2020;</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1623677"/>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Data curation" vocab-term-identifier="https://credit.niso.org/contributor-roles/data-curation/">Data curation</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; review &amp; editing" vocab-term-identifier="https://credit.niso.org/contributor-roles/writing-review-editing/">Writing &#x2013; review &amp; editing</role>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Cui</surname>
<given-names>Zengzhen</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1946226"/>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="software" vocab-term-identifier="https://credit.niso.org/contributor-roles/software/">Software</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; review &amp; editing" vocab-term-identifier="https://credit.niso.org/contributor-roles/writing-review-editing/">Writing &#x2013; review &amp; editing</role>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Lv</surname>
<given-names>Yang</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<xref ref-type="corresp" rid="c001">&#x2a;</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1365345"/>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Data curation" vocab-term-identifier="https://credit.niso.org/contributor-roles/data-curation/">Data curation</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="validation" vocab-term-identifier="https://credit.niso.org/contributor-roles/validation/">Validation</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; review &amp; editing" vocab-term-identifier="https://credit.niso.org/contributor-roles/writing-review-editing/">Writing &#x2013; review &amp; editing</role>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Zhou</surname>
<given-names>Fang</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<xref ref-type="corresp" rid="c001">&#x2a;</xref>
<uri xlink:href="https://loop.frontiersin.org/people/829864"/>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="investigation" vocab-term-identifier="https://credit.niso.org/contributor-roles/investigation/">Investigation</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="supervision" vocab-term-identifier="https://credit.niso.org/contributor-roles/supervision/">Supervision</role>
<role vocab="credit" vocab-identifier="https://credit.niso.org/" vocab-term="Writing &#x2013; review &amp; editing" vocab-term-identifier="https://credit.niso.org/contributor-roles/writing-review-editing/">Writing &#x2013; review &amp; editing</role>
</contrib>
</contrib-group>
<aff id="aff1">
<label>1</label>
<institution>Department of Orthopedics, Peking University Third Hospital</institution>, <city>Beijing</city>, <country country="CN">China</country>
</aff>
<aff id="aff2">
<label>2</label>
<institution>Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education</institution>, <city>Beijing</city>, <country country="CN">China</country>
</aff>
<author-notes>
<corresp id="c001">
<label>&#x2a;</label>Correspondence: Fang Zhou, <email xlink:href="zhouf@bjmu.edu.cn">zhouf@bjmu.edu.cn</email>; Yang Lv, <email xlink:href="lvyang42@126.com">lvyang42@126.com</email>
</corresp>
<fn fn-type="equal" id="fn001">
<label>&#x2020;</label>
<p>These authors have contributed equally to this work</p>
</fn>
</author-notes>
<pub-date publication-format="electronic" date-type="pub" iso-8601-date="2025-11-14">
<day>14</day>
<month>11</month>
<year>2025</year>
</pub-date>
<pub-date publication-format="electronic" date-type="collection">
<year>2025</year>
</pub-date>
<volume>13</volume>
<elocation-id>1658728</elocation-id>
<history>
<date date-type="received">
<day>03</day>
<month>07</month>
<year>2025</year>
</date>
<date date-type="rev-recd">
<day>07</day>
<month>10</month>
<year>2025</year>
</date>
<date date-type="accepted">
<day>30</day>
<month>10</month>
<year>2025</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#xa9; 2025 Fan, Hao, Cao, Cui, Lv and Zhou.</copyright-statement>
<copyright-year>2025</copyright-year>
<copyright-holder>Fan, Hao, Cao, Cui, Lv and Zhou</copyright-holder>
<license>
<ali:license_ref start_date="2025-11-14">https://creativecommons.org/licenses/by/4.0/</ali:license_ref>
<license-p>This is an open-access article distributed under the terms of the <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">Creative Commons Attribution License (CC BY)</ext-link>. The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</license-p>
</license>
</permissions>
<abstract>
<sec>
<title>Background</title>
<p>The purpose of this study was to explore the biomechanical property and clinical efficacy of femoral neck system (FNS) with an additional cannulated screws (CS) in the treatment of unstable femoral neck fracture (FNFs) with comminuted posteromedial cortex.</p>
</sec>
<sec>
<title>Methods</title>
<p>Firstly, we developed a model of Pauwels type III FNF with comminuted posteromedial cortex for the finite element analysis (FEA). Two experimental models were set up: the FNS model and the FNS &#x2b; CS model. The von Mises stress on the proximal femur, implant and the total displacement of the device components were evaluated for both FNS and FNS &#x2b; CS models. Secondly, we retrospectively included the cases of vertical FNFs with comminuted posteromedial cortex by FNS or FNS &#x2b; CS fixation in our hospital from January 2020 to December 2023. In this study, demographic information, femoral neck shortening, Harris score of hip joint function, and postoperative complications were collected and compared.</p>
</sec>
<sec>
<title>Results</title>
<p>The FEA results showed similar peak von Mises stress of the implant in two models and the additional CS could share the stress concentration with the FNS in the FNS &#x2b; CS model. In terms of proximal femur, the maximum von Mises stress of the FNS model increased by 15.43% when compared with the FNS &#x2b; CS model, and the magnitude of these two models were 83.02&#xa0;MPa and 71.92&#xa0;MPa, respectively. Furthermore, the maximum displacement in the FNS &#x2b; CS model was much smaller than that in the FNS model. Clinically, the femoral neck shortening distance was significantly longer in the FNS group (5.62 &#xb1; 3.32&#xa0;mm) than that in the FNS &#x2b; CS group (3.49 &#xb1; 2.01&#xa0;mm) (<italic>p</italic> &#x3d; 0.027). Furthermore, the incidence of moderate to severe shortening (&#x2265;5&#xa0;mm) was significantly higher in the FNS group compared with the FNS &#x2b; CS group (<italic>p</italic> &#x3d; 0.039). Moreover, the patients in the FNS &#x2b; CS group had a higher Harris score than patients in the FNS group (91.97 vs. 88.56, <italic>p</italic> &#x3d; 0.003).</p>
</sec>
<sec>
<title>Conclusion</title>
<p>Compared to the FNS alone, the FEA results showed that the FNS &#x2b; CS had better biomechanical properties and the clinical results showed that the FNS &#x2b; CS had a shorter femoral neck shortening and higher Harris score in treating unstable FNFs with comminuted posteromedial cortex.</p>
</sec>
</abstract>
<kwd-group>
<kwd>femoral neck fracture</kwd>
<kwd>comminuted posteromedial cortex</kwd>
<kwd>femoral neck system</kwd>
<kwd>cannulated screw</kwd>
<kwd>finite element analysis</kwd>
</kwd-group>
<funding-group>
<funding-statement>The author(s) declare that financial support was received for the research and/or publication of this article. This study was supported by Science and Technology fund of Winter Olympics (grant no. 2018YFF0301100); Key Clinical Projects of Peking University Third Hospital (grant no. BYSYZD2023040), and Capital&#x2019;s Funds for Health Improvement and Research (grant no. 2022-2-4096).</funding-statement>
</funding-group>
<counts>
<fig-count count="9"/>
<table-count count="2"/>
<equation-count count="0"/>
<ref-count count="39"/>
<page-count count="12"/>
</counts>
<custom-meta-group>
<custom-meta>
<meta-name>section-in-acceptance</meta-name>
<meta-value>Biomechanics</meta-value>
</custom-meta>
</custom-meta-group>
</article-meta>
</front>
<body>
<sec sec-type="intro" id="s1">
<title>Introduction</title>
<p>Femoral neck fractures (FNFs) are very common in the elderly patients, which are usually caused by low-energy injury. Whereas, FNFs in young and middle-aged adults are uncommon, which often result from high-energy injury (<xref ref-type="bibr" rid="B25">Roser et al., 2024</xref>). As a result, the high-energy injury can easily lead to severe bone fracture of the femoral neck. Given the high functional demands after surgery and the limited lifespan of artificial joints, surgical internal fixation remains the primary treatment choice for young and middle-aged patients with femoral neck fractures (FNFs) (<xref ref-type="bibr" rid="B2">Chan, 2019</xref>). At present, there are still many problems in the internal fixation for these unstable FNFs, and the incidence of postoperative complications is notably high (<xref ref-type="bibr" rid="B35">Yang et al., 2013</xref>). Therefore, it is very important to choose a proper implant for unstable FNFs to decrease the incidence of postoperative complications.</p>
<p>The femoral neck system (FNS), integrating the advantages of minimally invasive cannulated screws (CS) and the stability of dynamic hip screws (DHS), is a newly designed implant for FNFs which has the advantages of superior resistance to rotation and shear forces (<xref ref-type="bibr" rid="B29">Stoffel et al., 2017</xref>; <xref ref-type="bibr" rid="B11">Huang et al., 2023</xref>). Nevertheless, FNS-managed FNF patients continued to exhibit a relatively high incidence of postoperative complications (<xref ref-type="bibr" rid="B3">Davidson et al., 2022</xref>; <xref ref-type="bibr" rid="B27">Schuetze et al., 2023</xref>). Several studies emphasize the significance of posterior comminution in femoral neck fractures, considering it as a cause of unstable fixation (<xref ref-type="bibr" rid="B23">Rawall et al., 2012</xref>). The unstable FNFs can become even more unstable due to the loss of complete posterior cortical support for external rotation. In clinical practice, we find that the FNS fixation could provide only single-plane stability, while FNFs with posterior medial cortical defects are usually a three-dimensional spatial configuration. Single plane of the FNS cannot provide complete and effective mechanical support. To solve this problem, the additional CS has been introduced into clinical practice (<xref ref-type="bibr" rid="B17">Lin et al., 2024</xref>). By providing additional fixation points, the additional CS enhances the anti-shortening force, and the mechanical plane of the CS is not in the same plane with the FNS, forming angle stable fixation, which may effectively reduce postoperative complications.</p>
<p>Currently, it is still unclear whether an additional CS is necessary for unstable FNFs with comminuted posteromedial cortex by FNS fixation. This study aims to achieve the following objectives by constructing an unstable FNF with comminuted posteromedial cortex model and collecting clinical data of these patients: 1. Finite element analysis method is used to analyze and compare the biomechanical stability of FNS and FNS with an additional CS in the treatment of FNF with comminuted posteromedial cortex. 2. The clinical efficacy of FNS and FNS with an additional CS is evaluated and compared in treating FNFs with comminuted posteromedial cortex in young and middle-aged adults.</p>
</sec>
<sec sec-type="materials|methods" id="s2">
<title>Materials and methods</title>
<p>All methods and experimental protocols in this study were performed in accordance with relevant guidelines and regulations, and approved by the Institutional Ethical Review Board of Peking University Third Hospital.</p>
<sec id="s2-1">
<title>Finite element analysis (FEA)</title>
<sec id="s2-1-1">
<title>Establishment of the proximal femoral model and fracture model</title>
<p>In the current study, computed tomography images of a Sawbone femur (Model 3,406, fourth Generation Sawbone, Vashon, WA, United States) were acquired and imported into Mimics 19.0 (Materialise Group, Leuven, Belgium) to generate a three-dimensional model. This 3D finite element model was subsequently utilized in a prior investigation (<xref ref-type="bibr" rid="B38">Zhou et al., 2025</xref>).</p>
<p>Surface imperfections (including spikes and intersections) in the 3D model of the proximal femur were rectified using Geomagic Studio 12.0 (Raindrop Inc., United States). Following surface refinement, a smoothed solid model was generated and imported into SolidWorks (Dassault Syst&#xe8;mes SolidWorks Corp., United States). To simulate femoral neck fracture (FNF) models with comminuted posteromedial cortex: 1. A primary 20&#xb0; osteotomy was performed at the femoral neck center relative to the shaft axis, establishing a Pauwels type III fracture pattern; 2. Posteromedial cortical comminution was then created by resecting two wedges: a 30&#xb0; distal wedge and a 15&#xb0; posterior wedge (Relative to the initial osteotomy plane, following Windolf&#x2019;s protocol) (<xref ref-type="bibr" rid="B32">Windolf et al., 2009</xref>). (<xref ref-type="fig" rid="F1">Figure 1</xref>)</p>
<fig id="F1" position="float">
<label>FIGURE 1</label>
<caption>
<p>The unstable femoral neck fracture with comminuted posteromedial cortex. <bold>(A)</bold> the anterior view; <bold>(B)</bold> the posterior view.</p>
</caption>
<graphic xlink:href="fbioe-13-1658728-g001.tif">
<alt-text content-type="machine-generated">Two 3D renderings of a femur bone are shown, labeled A and B. Each femur has a dark gray shaft and a yellowish head. Image A displays the femur with the head intact, while in image B, the head appears to be offset or repositioned relative to the shaft, showcasing a different anatomical alignment. The background is a gradient of light blue.</alt-text>
</graphic>
</fig>
<p>According to the DePuy Synthes (West Chester, PA, United States) CS parameters, the screws featured a 7.3&#xa0;mm threaded diameter, 16&#xa0;mm length, and 4.8&#xa0;mm unthreaded diameter. In the FNS model, a 10-mm lag screw was positioned at 130&#xb0; to the locking plate, accompanied by a 6.4-mm anti-rotation screw angled at 7.5&#xb0; relative to the lag screw. At the distal end, one hole was made for a 5-mm locking screw. Then, the CS and FNS were virtually inserted into the FNF fracture model, and the FNS model and FNS with an additional CS (FNS &#x2b; CS) model were created (<xref ref-type="fig" rid="F2">Figure 2</xref>). The models were then transferred to ANSYS Workbench 14.5 (ANSYS Inc., Canonsburg, PA) for simulation.</p>
<fig id="F2" position="float">
<label>FIGURE 2</label>
<caption>
<p>The model of femoral neck fracture with comminuted posteromedial cortex implanted with the FNS and CS. <bold>(A)</bold> The FNS model; <bold>(B)</bold> The FNS &#x2b; CS model.</p>
</caption>
<graphic xlink:href="fbioe-13-1658728-g002.tif">
<alt-text content-type="machine-generated">Illustration showing two engineered designs (labeled A and B) of a femoral head and neck with surgical implants. Both designs include screws and plates securing the joint, displayed from two angles for comparison.</alt-text>
</graphic>
</fig>
<p>In the present study, all materials were assumed to be homogeneous, isotropic, and linearly elastic (<xref ref-type="bibr" rid="B9">Henschel et al., 2016</xref>). The material properties of the femur and implant materials were summarized in <xref ref-type="table" rid="T1">Table 1</xref> (<xref ref-type="bibr" rid="B13">Kwak et al., 2018</xref>). Based on established contact setup methods from previous studies, binding contact was applied between the internal fixation screw and the femur, while friction contact with a coefficient of 0.46 was used on the fracture surface (<xref ref-type="bibr" rid="B36">Zhou et al., 2020</xref>; <xref ref-type="bibr" rid="B28">Sensoz et al., 2018</xref>).</p>
<table-wrap id="T1" position="float">
<label>TABLE 1</label>
<caption>
<p>Material properties used in the simulations in this study.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="left">Material</th>
<th align="center">Young&#x2019;s modulus (Mpa)</th>
<th align="center">Poisson&#x2019;s ratio</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="left">Cortical bone</td>
<td align="center">17,000</td>
<td align="center">0.33</td>
</tr>
<tr>
<td align="left">Cancellous bone</td>
<td align="center">1,000</td>
<td align="center">0.3</td>
</tr>
<tr>
<td align="left">FNS/CS (Ti-6Al-7NB)</td>
<td align="center">110,000</td>
<td align="center">0.35</td>
</tr>
</tbody>
</table>
</table-wrap>
</sec>
<sec id="s2-1-2">
<title>Boundary and loading conditions</title>
<p>For boundary conditions, the distal end of the femur was fully constrained. The applied loading forces on the femur presented the loads during one-legged stance (<xref ref-type="bibr" rid="B20">Lotz et al., 1995</xref>). A joint reaction force of 1260N ({x, y, z} &#x3d; {365.4, &#x2212;126, &#x2212;1,197}) was applied at the femoral head (1.8 times body weight) (<xref ref-type="bibr" rid="B15">Lee et al., 2016</xref>).</p>
</sec>
<sec id="s2-1-3">
<title>Observation index</title>
<p>In the finite element analysis, the peak von Mises stress on the proximal femur and implant, the total displacements of the models were selected as indices of the stability. They were evaluated and compared under the one-legged stance.</p>
</sec>
</sec>
<sec id="s2-2">
<title>Clinical research</title>
<sec id="s2-2-1">
<title>Source of patients</title>
<p>This study was performed at a teaching hospital from January 2020 to December 2023. The inclusion criteria were as followed: (1) Age &#x3e;18&#xa0;years and &#x3c;60&#xa0;years; (2) Acute femoral neck fracture (&#x3c;2 weeks from injury); (3) X-ray examination showed that the fracture was significantly displaced, Pauwels type III (Pauwells angle &#x3e;50&#xb0;); (4) CT examination showed comminuted posteromedial cortex of the FNF; (5) Prior to the fracture, the proximal anatomy of the femur was normal, and there was no history of hip disease; (6) The FNF was fixed by FNS or FNS with an additional CS; (7) A minimum follow-up period of 12 months or until the time of failure leading to revision surgery. Patients with delayed fractures, history of hip joint disease, pathological fractures, combined with ipsilateral lower limb fractures and incomplete follow-up data were excluded.</p>
<p>The collected clinical data included: patient&#x2019;s gender, age, body mass index (BMI), fracture side, cause of injury, fracture classification based on the Garden and Pauwels systems, the surgical time, internal fixation method and blood loss during surgery.</p>
</sec>
<sec id="s2-2-2">
<title>Surgical procedure</title>
<p>All of the surgeries were performed by experienced orthopaedic surgeons. Spinal anesthesia or general anesthesia was used. Each FNF patient was placed on the traction table in the supine position. Reduction of the FNF was confirmed via intraoperative C-arm fluoroscopy, and the quality of fracture reduction was assessed by determining the Garden index. The Kirschner wire was temporarily inserted for fixation. Routine surgical procedures, including guide pin insertion, depth measurement, drilling, and installation of the FNS device, were performed for implantation of the FNS according to the manufacturer&#x2019;s protocol. For the FNS &#x2b; CS group, additional steps of guide pin insertion, depth measurement, and drilling were performed, followed by implantation of the additional CS. Before the wound was closed, the reduction and proper insertion of FNS components were confirmed via C-arm fluoroscopy. Postoperatively, patients received antibiotic prophylaxis and deep vein thrombosis (DVT) prophylaxis, with partial weight-bearing initiated after evidence of fracture healing was observed on radiographs and total weight-bearing commenced once clinical fracture healing was confirmed. Follow-up evaluations were conducted at 1, 3, 6, and 12 months postoperatively and annually thereafter.</p>
</sec>
</sec>
<sec id="s2-3">
<title>Outcomes</title>
<sec id="s2-3-1">
<title>Reduction quality assessment</title>
<p>Garden index This commonly used classification system categorized FNFs into four levels based on the extent of displacement and the quality of reduction (<xref ref-type="bibr" rid="B6">GARDEN, 1964</xref>). Employed to predict fracture healing difficulty and potential complications, this method relied on routine postoperative radiographs to assess reduction quality. The grading system was: Grade I (AP 160&#xb0;, Lateral 180&#xb0;); Grade II (AP 155&#xb0;, Lateral 180&#xb0;); Grade III (AP &#x3c; 155&#xb0; or Lateral &#x3e; 180&#xb0;); Grade IV (AP &#x3c; 150&#xb0;, Lateral &#x3e; 180&#xb0;). Grades III and IV signified poor reduction quality.</p>
</sec>
<sec id="s2-3-2">
<title>Tip apex distance (TAD)</title>
<p>Immediately after surgery, anteroposterior (AP) and lateral radiographs of the hip joint were obtained. On these views, the distance from the tip of the screw to the apex of the intersection, formed by the femoral head-neck axis and the articular surface of the femoral head, was measured. Specifically, the anteroposterior distance (Xap) and lateral distance (Xlat) were recorded. The actual width of the screw (Dtrue) was used to correct the magnification factor of the screw width measured on the AP (Dap) and lateral (Dlat) views. The sum of these corrected distances was then calculated to determine the TAD value, using the formula: TAD &#x3d; (Xap &#xd7; Dap)/Dtrue &#x2b; (Xlat &#xd7; Dlat)/Dtrue (<xref ref-type="bibr" rid="B31">Subasi et al., 2022</xref>).</p>
</sec>
<sec id="s2-3-3">
<title>Femoral neck shortening</title>
<p>The amount of femoral neck shortening was measured on radiographs on anteroposterior (AP) radiographs using the method described by Zlowodzki et al. (<xref ref-type="bibr" rid="B39">Zlowodzki et al., 2008</xref>). The healthy side was served as a reference for measuring horizontal (X-axis) and vertical (Y-axis) femoral head shortening on the affected side. Femoral neck axial shortening (Z-axis) was derived from formula Z &#x3d; Ysin(&#x3b8;) &#x2b; Xcos(&#x3b8;), where &#x3b8; is the angle between the Y-axis and the femoral neck axis. Shortening severity, defined by the Z value, was classed as mild (&#x3c;5&#xa0;mm), moderate (5&#x2013;10&#xa0;mm), or severe (&#x3e;10&#xa0;mm).</p>
</sec>
<sec id="s2-3-4">
<title>Postoperative complications</title>
<p>This included implant failure (e.g., fracture or deformation), delayed or nonunion, implant displacement relative to the bone (without femoral head penetration), deep incisional infection, implant penetration into the joint cavity via the femoral head, avascular necrosis of the femoral head, and the requirement for secondary total hip arthroplasty (<xref ref-type="bibr" rid="B18">Lin et al., 2025</xref>).</p>
</sec>
</sec>
<sec id="s2-4">
<title>Statistical analysis</title>
<p>Continuous data were presented as mean &#xb1; standard deviation (SD) for normally distributed variables or median with interquartile range (IQR) for non-normally distributed variables. The normality test was assessed using the Shapiro-Wilk test. Student&#x2019;s t-test was applied to normally distributed data, while nonparametric methods were used for non-normally distributed data. Categorical variables were analyzed with the chi-square test, and ranked data were evaluated using the Mann-Whitney U test. A significance level of <italic>p</italic> &#x3c; 0.05 was considered statistically significant. Statistical analyses were performed with IBM SPSS Statistics (Version 26.0).</p>
</sec>
</sec>
<sec sec-type="results" id="s3">
<title>Results</title>
<sec id="s3-1">
<title>FEA results</title>
<p>The von Mises stress distributions for two internal fixation models were assessed and shown in <xref ref-type="fig" rid="F3">Figure 3</xref>. In the FNS model, the stress concentration area was located at the anti-rotational screw and the peak von Mises stress was 128.42&#xa0;MPa. In the FNS &#x2b; CS model, the peak von Mises stress was 146.15&#xa0;MPa, whereas the stress concentration area was located at the CS and sliding hip screw. Therefore, the CS could share the stress concentration with the FNS.</p>
<fig id="F3" position="float">
<label>FIGURE 3</label>
<caption>
<p>The Von Mises stress distribution (MPa) on the implant. <bold>(A)</bold> The FNS model; <bold>(B)</bold> The FNS &#x2b; CS model.</p>
</caption>
<graphic xlink:href="fbioe-13-1658728-g003.tif">
<alt-text content-type="machine-generated">Top and bottom finite element analysis simulation images labeled A and B depict stress distribution on mechanical components. Color gradients from blue to red represent stress levels, with corresponding scales showing numerical values. Image A shows maximum stress at 128.42, while image B shows maximum stress at 146.15.</alt-text>
</graphic>
</fig>
<p>
<xref ref-type="fig" rid="F4">Figure 4</xref> depicted the von Mises stress distribution in the proximal femur for FNS and FNS &#x2b; CS. While the stress concentration area was located at the inferior femur in both models, differences in the distribution were observed. The maximum von Mises stress in the FNS model was 83.02&#xa0;MPa, which represented a 15.43% increase compared to the FNS &#x2b; CS model (71.92&#xa0;MPa).</p>
<fig id="F4" position="float">
<label>FIGURE 4</label>
<caption>
<p>The Von Mises stress distribution (MPa) on the proximal femur. <bold>(A)</bold> The FNS model; <bold>(B)</bold> The FNS &#x2b; CS model.</p>
</caption>
<graphic xlink:href="fbioe-13-1658728-g004.tif">
<alt-text content-type="machine-generated">Two femur models labeled A and B with color-coded stress analysis. Model A shows a maximum stress of 83.02 and a minimum of 0.014664, while model B shows a maximum stress of 71.915 and a minimum of 0.011246. The color scale ranges from red (high stress) to blue (low stress).</alt-text>
</graphic>
</fig>
<p>
<xref ref-type="fig" rid="F5">Figure 5</xref> depicted the model displacement distribution in two models. For both models, the maximum displacements occurred at the top of the femoral head. The maximum model displacement of the FNS model increased by 25.67% when compared with the FNS &#x2b; CS model, and the magnitude of these two models were 4.83&#xa0;mm and 3.59mm, respectively.</p>
<fig id="F5" position="float">
<label>FIGURE 5</label>
<caption>
<p>Displacement distribution (mm) in both models. <bold>(A)</bold> The FNS model; <bold>(B)</bold> The FNS &#x2b; CS model.</p>
</caption>
<graphic xlink:href="fbioe-13-1658728-g005.tif">
<alt-text content-type="machine-generated">Two color-coded 3D models of a femur labeled A and B compare stress distribution. A shows a higher maximum stress value of 4.8335, and B a lower value of 3.5928. Color scales represent stress intensity from red (high) to blue (low).</alt-text>
</graphic>
</fig>
</sec>
<sec id="s3-2">
<title>Clinical results</title>
<p>A total of 41 patients were included in this study, with 25 patients in the FNS group and 16 patients in the FNS &#x2b; CS group. (<xref ref-type="table" rid="T2">Table 2</xref>). Clinical characteristics of patients in two groups were summarized in <xref ref-type="table" rid="T1">Table 1</xref>. Patients in the FNS &#x2b; CS group were slightly older than those in the FNS group (49.38 vs. 48.44, <italic>p</italic> &#x3d; 0.816). Of these patients, 7 (28%) were female patients in the FNS group, and 4 (25%) were female patients in the FNS &#x2b; CS group. The average BMI was 23.85 (&#xb1;2.49)&#xa0;kg/m2 and 25.32 (&#xb1;3.77)&#xa0;kg/m2 in the FNS group and FNS &#x2b; CS group, respectively (P &#x3d; 0.140). With respect to the injury side and mechanism of injury, 18 (72%) had left side injury and 17 (68%) suffered from fall from height injury in the FNS group, and 9 (56.3%) had left side injury and 13 (81.3%) suffered from fall from height injury in the FNS &#x2b; CS group. Patients belonging to the FNS group had a similar level of surgical time (60.64 vs. 63.06, <italic>p</italic> &#x3d; 0.744), intraoperative bleeding (34.00 vs. 33.13, <italic>p</italic> &#x3d; 0.892), TAD (16.71 vs. 16.36, <italic>p</italic> &#x3d; 0.831), healing time (8.08 vs. 8.38, <italic>p</italic> &#x3d; 0.071) and length of stay (3.32 vs. 3.63, <italic>p</italic> &#x3d; 0.401) compared with those in the FNS &#x2b; CS group. In addition, similar levels of Garden classification and reduction quality were found in both the FNS group and FNS &#x2b; CS group (<italic>p</italic> &#x3e; 0.05).</p>
<table-wrap id="T2" position="float">
<label>TABLE 2</label>
<caption>
<p>Comparison of the clinical characteristics between the FNS group and FNS &#x2b; CS group.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="left">Characteristic</th>
<th align="center">FNS group (N &#x3d; 25)</th>
<th align="center">FNS &#x2b; CS group (N &#x3d; 16)</th>
<th align="center">P Value</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="left">Age (mean years&#xb1;SD)</td>
<td align="center">48.44 &#xb1; 14.09</td>
<td align="center">49.38 &#xb1; 9.21</td>
<td align="center">0.816</td>
</tr>
<tr>
<td align="left">Women, N (%)</td>
<td align="center">7 (28.0)</td>
<td align="center">4 (25.0)</td>
<td align="center">0.833</td>
</tr>
<tr>
<td align="left">BMI (kg/m2)</td>
<td align="center">23.85 &#xb1; 2.49</td>
<td align="center">25.32 &#xb1; 3.77</td>
<td align="center">0.140</td>
</tr>
<tr>
<td align="left">Injury side (left/right)</td>
<td align="left"/>
<td align="left"/>
<td align="center">0.300</td>
</tr>
<tr>
<td align="left">&#xa0;&#xa0;&#xa0;Left, N (%)</td>
<td align="center">18 (72.0)</td>
<td align="center">9 (56.3)</td>
<td align="left"/>
</tr>
<tr>
<td align="left">&#xa0;&#xa0;&#xa0;Right, N (%)</td>
<td align="center">7 (28.0)</td>
<td align="center">7 (43.8)</td>
<td align="left"/>
</tr>
<tr>
<td align="left">Mechanism of injury</td>
<td align="left"/>
<td align="left"/>
<td align="center">0.350</td>
</tr>
<tr>
<td align="left">&#xa0;&#xa0;&#xa0;Fall from height, N (%)</td>
<td align="center">17 (68.0)</td>
<td align="center">13 (81.3)</td>
<td align="left"/>
</tr>
<tr>
<td align="left">&#xa0;&#xa0;&#xa0;Motor vehicle collision, N (%)</td>
<td align="center">8 (32.0)</td>
<td align="center">3 (18.8)</td>
<td align="left"/>
</tr>
<tr>
<td align="left">Smoking, N (%)</td>
<td align="center">2 (8.0)</td>
<td align="center">3 (18.8)</td>
<td align="center">0.305</td>
</tr>
<tr>
<td align="left">Drinking, N (%)</td>
<td align="center">2 (8.0)</td>
<td align="center">2 (12.5)</td>
<td align="center">0.636</td>
</tr>
<tr>
<td align="left">Garden classification</td>
<td align="left"/>
<td align="left"/>
<td align="center">0.444</td>
</tr>
<tr>
<td align="left">&#xa0;&#xa0;&#xa0;Garden III, N (%)</td>
<td align="center">14 (56.0)</td>
<td align="center">7 (43.8)</td>
<td align="left"/>
</tr>
<tr>
<td align="left">&#xa0;&#xa0;&#xa0;Garden IV, N (%)</td>
<td align="center">11 (44.0)</td>
<td align="center">9 (56.3)</td>
<td align="left"/>
</tr>
<tr>
<td align="left">Surgical time (mm)</td>
<td align="center">60.64 &#xb1; 25.59</td>
<td align="center">63.06 &#xb1; 18.02</td>
<td align="center">0.744</td>
</tr>
<tr>
<td align="left">Intraoperative bleeding (mm)</td>
<td align="center">34.00 &#xb1; 23.63</td>
<td align="center">33.13 &#xb1; 12,50</td>
<td align="center">0.892</td>
</tr>
<tr>
<td align="left">Reduction quality</td>
<td align="left"/>
<td align="left"/>
<td align="center">0.395</td>
</tr>
<tr>
<td align="left">&#xa0;&#xa0;&#xa0;Neutral support, N (%)</td>
<td align="center">16 (64.0)</td>
<td align="center">8 (50.0)</td>
<td align="left"/>
</tr>
<tr>
<td align="left">&#xa0;&#xa0;&#xa0;Positive support, N (%)</td>
<td align="center">6 (24.0)</td>
<td align="center">7 (43.8)</td>
<td align="left"/>
</tr>
<tr>
<td align="left">&#xa0;&#xa0;&#xa0;Negative support, N (%)</td>
<td align="center">3 (12.0)</td>
<td align="center">1 (6.3)</td>
<td align="left"/>
</tr>
<tr>
<td align="left">TAD (mm)</td>
<td align="center">16.71 &#xb1; 5.57</td>
<td align="center">16.36 &#xb1; 4.19</td>
<td align="center">0.831</td>
</tr>
<tr>
<td align="left">Healing time (week)</td>
<td align="center">8.08 &#xb1; 0.28</td>
<td align="center">8.38 &#xb1; 0.72</td>
<td align="center">0.071</td>
</tr>
<tr>
<td align="left">Length of stay (day)</td>
<td align="center">3.32 &#xb1; 1.28</td>
<td align="center">3.63 &#xb1; 0.81</td>
<td align="center">0.401</td>
</tr>
<tr>
<td align="left">Femoral neck shortening (mm)</td>
<td align="center">5.62 &#xb1; 3.32</td>
<td align="center">3.49 &#xb1; 2.01</td>
<td align="center">0.027&#x2a;</td>
</tr>
<tr>
<td align="left">Femoral neck shortening grade</td>
<td align="left"/>
<td align="left"/>
<td align="center">0.039&#x2a;</td>
</tr>
<tr>
<td align="left">&#xa0;&#xa0;&#xa0;Mild (&#x3c;5&#xa0;mm), N (%)</td>
<td align="center">11 (44.0)</td>
<td align="center">13 (81.3)</td>
<td align="left"/>
</tr>
<tr>
<td align="left">&#xa0;&#xa0;&#xa0;Moderate (5&#x2013;10&#xa0;mm), N (%)</td>
<td align="center">9 (36.0)</td>
<td align="center">3 (18.8)</td>
<td align="left"/>
</tr>
<tr>
<td align="left">&#xa0;&#xa0;&#xa0;Severe (&#x3e;10&#xa0;mm), N (%)</td>
<td align="center">5 (20.0)</td>
<td align="center">0 (0)</td>
<td align="left"/>
</tr>
<tr>
<td align="left">Harris score</td>
<td align="center">88.56 &#xb1; 2.87</td>
<td align="center">91.97 &#xb1; 4.06</td>
<td align="center">0.003&#x2a;</td>
</tr>
<tr>
<td align="left">Postoperative complications</td>
<td align="center">2 (8.0%)</td>
<td align="center">2 (12.5%)</td>
<td align="center">0.636</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn>
<p>Abbreviations: BMI, body mass index; FNS, femoral neck system; CS, cannulated screw; TAD, tip apex distance; SD, standard deviation.</p>
</fn>
<fn>
<p>&#x2a;The difference was significant.</p>
</fn>
</table-wrap-foot>
</table-wrap>
<p>In addition, the femoral neck shortening distance was significantly longer in the FNS group (5.62 &#xb1; 3.32&#xa0;mm) than that in the FNS &#x2b; CS group (3.49 &#xb1; 2.01&#xa0;mm) (<italic>p</italic> &#x3d; 0.027). Furthermore, the incidence of moderate to severe shortening (&#x2265;5&#xa0;mm) was significantly higher in the FNS group compared with the FNS &#x2b; CS group (<italic>p</italic> &#x3d; 0.039). These findings suggested that the additional CS might be more effective in reducing femoral neck shortening compared with the FNS along. Moreover, the patients in the FNS &#x2b; CS group had a higher Harris score than patients in the FNS group (91.97 vs. 88.56, <italic>p</italic> &#x3d; 0.003). In terms of postoperative complications, the one-year follow-up results showed that one case of fracture nonunion occurred in the FNS group and the avascular necrosis of the femoral head occurred in one case in the FNS &#x2b; CS group. In the two-year follow-up results showed that one case of fracture nonunion and one case of femoral head avascular necrosis occurred in the FNS group, and two cases of the avascular necrosis of the femoral head occurred in the FNS &#x2b; CS group. Typical successful cases were shown in <xref ref-type="fig" rid="F6">Figures 6</xref>, <xref ref-type="fig" rid="F7">7</xref>. The typical unsuccessful cases and pictures of two groups were shown in <xref ref-type="fig" rid="F8">Figures 8</xref>, <xref ref-type="fig" rid="F9">9</xref>.</p>
<fig id="F6" position="float">
<label>FIGURE 6</label>
<caption>
<p>Case presentation: a 42&#xa0;years old man with right femoral neck fracture fixed with FNS. <bold>(A,B)</bold> Preoperative anteroposterior radiograph and CT scan showed the right FNF with posteromedial cortex fracture. <bold>(C,D)</bold> The anteroposterior and lateral X-ray with FNS 1&#xa0;day after surgery; <bold>(E,F)</bold> The anteroposterior and lateral X-rays 1Dmonth after surgery; <bold>(G,H)</bold> The anteroposterior and lateral X-rays 3&#xa0;months after surgery; <bold>(I,J)</bold> The anteroposterior and lateral X-rays 6&#xa0;months after surgery; <bold>(K,L)</bold> The anteroposterior and lateral X-rays 12&#xa0;months after surgery.</p>
</caption>
<graphic xlink:href="fbioe-13-1658728-g006.tif">
<alt-text content-type="machine-generated">Twelve-panel image showing X-rays of a hip with a fracture. Panel A shows a pre-surgery hip. Panel B shows a CT scan. Panels C to L illustrate post-surgery images with varying angles and stages of recovery involving fixation hardware. Each image shows different perspectives and progressions in the treatment process.</alt-text>
</graphic>
</fig>
<fig id="F7" position="float">
<label>FIGURE 7</label>
<caption>
<p>Case presentation: a 56&#xa0;years old man with left femoral neck fracture fixed with FNS &#x2b; CS. <bold>(A,B)</bold> Preoperative anteroposterior radiograph and CT scan showed the right FNF with posteromedial cortex fracture. <bold>(C,D)</bold> The anteroposterior and lateral X-ray with FNS 1&#xa0;day after surgery; <bold>(E,F)</bold> The anteroposterior and lateral X-rays 1 month after surgery; <bold>(G,H)</bold> The anteroposterior and lateral X-rays 3&#xa0;months after surgery; <bold>(I,J)</bold> The anteroposterior and lateral X-rays 6 months after surgery; <bold>(K,L)</bold> The anteroposterior and lateral X-rays 12&#xa0;months after surgery.</p>
</caption>
<graphic xlink:href="fbioe-13-1658728-g007.tif">
<alt-text content-type="machine-generated">Twelve-panel medical image showing X-rays of a hip joint. Panel A depicts a normal hip. Panel B displays a CT scan. Panels C to L illustrate different stages and angles of a surgical procedure involving a metal implant in the hip. Each panel highlights bone alignment and implant positioning.</alt-text>
</graphic>
</fig>
<fig id="F8" position="float">
<label>FIGURE 8</label>
<caption>
<p>Case presentation: a 35&#xa0;years old man with left femoral neck fracture fixed with FNS. <bold>(A,B)</bold> Preoperative anteroposterior radiograph and CT scan showed the left FNF with posteromedial cortex fracture. <bold>(C,D)</bold> The anteroposterior and lateral X-ray with FNS 1&#xa0;day after surgery; <bold>(E,F)</bold> The anteroposterior and lateral X-rays 1 month after surgery; <bold>(G,H)</bold> The anteroposterior and lateral X-rays 3&#xa0;months after surgery; <bold>(I,J)</bold> The anteroposterior and lateral X-rays 6&#xa0;months after surgery; <bold>(K,L)</bold> The anteroposterior and lateral X-rays 12&#xa0;months after surgery.</p>
</caption>
<graphic xlink:href="fbioe-13-1658728-g008.tif">
<alt-text content-type="machine-generated">Twelve medical imaging panels show X-rays of a hip joint, labeled A to L. Panels A and B display the hip prior to fixation. Panels C to L illustrate various stages of implant positioning and fixation within the hip joint, highlighting the presence of surgical hardware.</alt-text>
</graphic>
</fig>
<fig id="F9" position="float">
<label>FIGURE 9</label>
<caption>
<p>Case presentation: a 46&#xa0;years old woman with right femoral neck fracture fixed with FNS. <bold>(A,B)</bold> Preoperative CT scan showed the right FNF with posteromedial cortex fracture. <bold>(C,D)</bold> The anteroposterior and lateral X-ray with FNS 1&#xa0;day after surgery; <bold>(E,F)</bold> The anteroposterior and lateral X-rays 1&#xa0;month after surgery; <bold>(G,H)</bold> The anteroposterior and lateral X-rays 3&#xa0;months after surgery; <bold>(I,J)</bold> The anteroposterior and lateral X-rays 6 months after surgery; <bold>(K,L)</bold> The anteroposterior and lateral X-rays 12&#xa0;months after surgery.</p>
</caption>
<graphic xlink:href="fbioe-13-1658728-g009.tif">
<alt-text content-type="machine-generated">A series of twelve images showing X-rays and CT scans of a hip joint. Images A and B display pre-operative CT scans. Images C to L display post-operative X-rays featuring a surgical implant used for hip fixation. Each image is labeled from A to L, showcasing different angles and stages of the procedure.</alt-text>
</graphic>
</fig>
</sec>
</sec>
<sec sec-type="discussion" id="s4">
<title>Discussion</title>
<p>The substantial energy trauma of the fracture itself and the inappropriate internal fixation system are related to the functional recovery of femoral neck fractures (<xref ref-type="bibr" rid="B12">Jiang et al., 2023</xref>; <xref ref-type="bibr" rid="B24">Robinson et al., 1995</xref>). The high energy trauma might result in more displaced and comminuted fracture. Compared to non-displaced fracture, the displaced FNF (Garden type III and &#x2163;) has a higher risk of fracture nonunion and femoral head necrosis (<xref ref-type="bibr" rid="B33">Xin et al., 2023</xref>). For displaced FNF, the external rotational stress could lead to anterior femoral cortex fracture and the posterior cortex comminution. Previous study reported that up to 70% of unstable displaced FNSs had posterior cortex comminution or bone defects (<xref ref-type="bibr" rid="B19">Liu et al., 2019</xref>). Anatomical reduction and stable fixation for these extremely unstable FNFs with posterior bone defect was vital for fracture union and satisfactory function recovery. In this study, the FEA results showed that the additional CS could shear the stress conduction and decrease the total model displacement. The clinical results showed that patients in the FNS &#x2b; CS group had a lower risk of femoral neck shortening and higher Harris score.</p>
<p>Currently, it was still unclear which implant was the best choice for these extremely unstable FNFs. These fractures posed great challenges for surgical reduction and fixation for their inherent instability, resulting in great difficulty in consistently achieving a stable construct and maintaining reduction. Inadequate stabilization could result in displacement, disruption of blood supply, and fixation failure, with subsequent development of nonunion and avascular necrosis (AVN) of the femoral head. Theoretically, the ideal implant should maintain angular and longitudinal stability, resist forces traversing the fracture site, and permit controlled micro-dynamization (<xref ref-type="bibr" rid="B14">Lazaro et al., 2016</xref>). Currently, multiple cannulated cancellous screws (MCS) were the predominant fixation method for femoral neck fractures. However, this construct lacked inherent stability between screws, and screw placement was highly dependent on surgeon technique and anatomical variables. Consequently, MCS demonstrated poor resistance to vertical shear and torsional forces, potentially leading to screw loosening, fracture displacement, femoral head avascular necrosis, nonunion, and femoral neck shortening. Previous studies had reported that the MCS was unable to firmly fix Pauwels type III FNF and showed more postoperative complications (<xref ref-type="bibr" rid="B26">Samsami et al., 2015</xref>; <xref ref-type="bibr" rid="B21">Ma et al., 2018</xref>). The DHS-blade, offering superior stability, was established as the European gold standard for treating unstable femoral neck fractures. However, it required a larger skin incision and more extensive soft tissue dissection (<xref ref-type="bibr" rid="B1">Bhan et al., 2009</xref>). Integrating the benefits of minimally invasive surgery and angle-stable fixation, the FNS utilized a unique design: an anti-rotational screw locked into the bolt, allowing both components to slide dynamically within the plate barrel. This dynamic fixation, combined with a fixed plate and integrated lag screw, significantly strengthened angular stability. This effectively prevented reduction loss and provided superior anti-rotation. Clinical evidence established FNS as superior to MCS fixation for femoral neck fractures, associated with faster patient recovery and lower complication rates (<xref ref-type="bibr" rid="B11">Huang et al., 2023</xref>; <xref ref-type="bibr" rid="B34">Xu et al., 2024</xref>). However, postoperative complications could occur in Pauwels type III FNF after FNS fixation, especially for unstable FNF with comminuted posteromedial cortex (<xref ref-type="bibr" rid="B8">Guo et al., 2024</xref>). A few researchers recommended an additional CS to increase the fracture fixation stability (<xref ref-type="bibr" rid="B30">Su et al., 2023</xref>). This might be the additional CS could achieve different plane fixations and increase angle stability.</p>
<p>For complex femoral neck fractures, postoperative biomechanical stability directly correlated with positive treatment outcomes. Biomechanically, the additional CS of the Femoral Neck System (FNS) enhanced screw-screw spacing, mitigated stress concentration, and transformed shear forces into compressive forces. This stabilized the fracture site, created an optimal mechanical environment for bone healing, and reduced postoperative fixation failure risks. To evaluate the stability of unstable FNFs featuring comminuted posteromedial cortex and stabilized with FNS or FNS &#x2b; CS, the primary indicator was the total displacement of the proximal femur and the fixation device under load. In this study, the FEA results showed that the additional CS could share the stress concentration with the FNS. Furthermore, the maximum model displacement of the FNS model increased by 25.67% when compared with the FNS &#x2b; CS model, showing good postoperative stability. For unstable FNFs, the lack of posterior support could lead to an imbalance in force loading on the femoral head, which might result in varus or cutout complications. In the case of these complex femoral neck fractures, the implant served as the sole supportive mechanism capable of providing effective support. Additionally, unstable FNFs could generate shear forces at the fracture site, causing medialization and shortening of the femoral shaft, accompanied by varus angulation and external rotation of the proximal fragment (<xref ref-type="bibr" rid="B5">Gao et al., 2025</xref>). Therefore, minimizing interfragmentary movement was essential for achieving relative stability during early fracture healing. In this study, the FNS augmented with additional CS (FNS &#x2b; CS) effectively stabilized the femoral head fragment, demonstrating significantly reduced fracture displacement. These findings suggested that FNS &#x2b; CS might serve as a viable alternative for unstable femoral neck fractures with posterior bone defects due to its superior biomechanical stability.</p>
<p>Femoral neck shortening remained a common surgical complication of femoral neck fractures, which adversely affected patient prognosis (<xref ref-type="bibr" rid="B16">Lee et al., 2024</xref>; <xref ref-type="bibr" rid="B4">Felton et al., 2019</xref>). The FNS featured a 20&#xa0;mm sliding compression space which could prevent excessive sliding and minimize femoral neck shortening, and its dynamic compression mechanism at the fracture site might enhance fracture healing (<xref ref-type="bibr" rid="B37">Zhou et al., 2021</xref>). In this study, the FNS &#x2b; CS group had significantly lower degrees of femoral neck shortening than the FNS group (<italic>p</italic> &#x3d; 0.027). Furthermore, the incidence of moderate to severe shortening (&#x2265;5&#xa0;mm) was significantly higher in the FNS group compared with the FNS &#x2b; CS group (<italic>p</italic> &#x3d; 0.039). These findings suggested that the additional CS might be more effective in reducing femoral neck shortening compared with the FNS along. Moreover, the patients in the FNS &#x2b; CS group had a higher Harris score than patients in the FNS group (91.97 vs. 88.56, <italic>p</italic> &#x3d; 0.003). The larger femoral neck shortening, especially shortening greater than 10&#xa0;mm, could impact limb function. The FNS group had a higher incidence of severe femoral neck shortening than the FNS &#x2b; CS group. However, the Harris score differences were small (&#x223c;3 points). The Harris score would be categorized as excellent (90&#x2013;100), good (80&#x2013;89), fair (70&#x2013;79), or poor (&#x3c;70). All patients in the FNS group and FNS &#x2b; CS group had a good Harris score, although a statistical difference was found. The clinical meaningfulness of this improvement should be evaluated carefully by the orthorpeadic surgeons. The superior fixation stability achieved by FNS &#x2b; CS likely contributed to enhance fracture healing and improve functional outcomes. However, these results should be interpreted with caution due to the smaller sample size in the FNS &#x2b; CS group relative to the FNS group, warranting larger-scale studies to validate these observations. Furthermore, the additional CS had a risk of joint penetration, or weakening of bone stock for future arthroplasty. For non-elderly patients, a good reduction quality and a firm fixation method was the first choice (<xref ref-type="bibr" rid="B25">Roser et al., 2024</xref>). For these patients, a relatively good bone mineral density might decrease the risk of joint penetration. The orthopeadic surgeon should balance the benefit of better stability and potential risk of the additional CS.</p>
<p>The development of femoral head avascular necrosis after FNFs was associated with several risk factors, including initial fracture displacement, the quality of intraoperative reduction, internal fixation stability, and postoperative weight-bearing duration. Fracture could disrupt the blood supply to the femoral head. Although the bony structure might heal, restoring and reconstructing the blood supply remained challenging. Consequently, assessing femoral head necrosis necessitated a minimum follow-up period of 2 years (<xref ref-type="bibr" rid="B22">Parker et al., 2013</xref>). Previous studies had reported that the incidence of femoral head osteonecrosis ranging from 10% to 30% with any internal fixation method, and our results were comparable (<xref ref-type="bibr" rid="B10">Hoshino et al., 2016</xref>; <xref ref-type="bibr" rid="B7">Gardner et al., 2015</xref>). In present study, the incidence of femoral head osteonecrosis in the FNS &#x2b; CS group was higher than that in the FNS group, yet no statistically significant difference was observed. Additional follow-up was also required to ascertain whether the femoral head osteonecrosis rate continued to increase in patients undergoing FNS and FNS &#x2b; CS treatments. Most notably, surgeons should strive to achieve perfect reduction during surgery and use minimally invasive techniques to preserve the blood supply to the femoral head. Longer follow-up periods and large-sample prospective studies were required in the future.</p>
<p>This study has some limitations. First, the femur and implants were inherently anisotropic materials. Nevertheless, in this study, to reduce the complexity of analysis, they were simplified into uniform, isotropic, and elastic materials. Secondly, this study did not account for the influence of soft tissues, including muscles and skin surrounding the femur, on the forces experienced by the femur following internal fixation. The simplified model with isotropic and linear elastic materials and the omission of soft tissue constraints were significant limitations. Although this approach incorporated simplifications and introduced potential discrepancies with actual conditions, it still provided a distinct trend for the research focus. Thirdly, a notable limitation of this study was the absence of experimental validation to confirm the model&#x2019;s accuracy. Nevertheless, since the study&#x2019;s objective was to compare relative values under identical loading environments and boundary conditions, the omission of validation testing was deemed acceptable. Future studies with more physiologically accurate models and experimental validation (bench-top testing) were necessary to confirm these theoretical results. Fourth, the sample size was relatively limited and this was a retrospective study. The retrospective design might have introduced selection bias, as the internal fixation method was chosen based on clinical experience, with surgeons potentially opting for augmented fixation in more complex cases. To enhance the reliability of our findings, a randomized, multicenter prospective study was warranted. Fifth, the follow-up was short. A longer follow-up and large sample of prospective study was needed in the future. Sixth, during the measurement of the femoral neck shortening, neck shaft angle, and TAD, non-standard patient positioning during radiography might have influenced the measured values. However, to minimize this potential source of error, a single researcher conducted all measurements, and the results were averaged across three measurements for each patient.</p>
</sec>
<sec sec-type="conclusion" id="s5">
<title>Conclusion</title>
<p>In summary, compared to the FNS alone, the FEA results showed that the additional CS could share the stress concentration with the FNS and exhibit smaller maximum model displacement in unstable femoral neck fractures with comminuted posteromedial cortex. This suggested that the additional CS might provide a better mechanical environment for fracture healing. Furthermore, the clinical results showed that the FNS in combination with an additional CS had a shorter femoral neck shortening and higher Harris score in treating FNFs with posteromedial defect compared with FNS alone. Therefore, the additional cannulated screw might be necessary for unstable FNFs with comminuted posteromedial cortex by femoral neck system (FNS) fixation.</p>
</sec>
</body>
<back>
<sec sec-type="data-availability" id="s6">
<title>Data availability statement</title>
<p>The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.</p>
</sec>
<sec sec-type="ethics-statement" id="s7">
<title>Ethics statement</title>
<p>The studies involving humans were approved by the Institutional Review Board of Peking University Third Hospital. The studies were conducted in accordance with the local legislation and institutional requirements. Written informed consent for participation in this study was provided by the participants&#x2019; legal guardians/next of kin. Written informed consent was obtained from the individual(s), and minor(s)&#x2019; legal guardian/next of kin, for the publication of any potentially identifiable images or data included in this article.</p>
</sec>
<sec sec-type="author-contributions" id="s8">
<title>Author contributions</title>
<p>JF: Data curation, Methodology, Software, Writing &#x2013; original draft. YH: Data curation, Software, Writing &#x2013; review and editing. YC: Data curation, Writing &#x2013; review and editing. ZC: Software, Writing &#x2013; review and editing. YL: Data curation, Validation, Writing &#x2013; review and editing. FZ: Investigation, Supervision, Writing &#x2013; review and editing.</p>
</sec>
<sec sec-type="COI-statement" id="s10">
<title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
<p>The author(s) declared that they were an editorial board member of Frontiers, at the time of submission. This had no impact on the peer review process and the final decision.</p>
</sec>
<sec sec-type="ai-statement" id="s11">
<title>Generative AI statement</title>
<p>The author(s) declare that no Generative AI was used in the creation of this manuscript.</p>
<p>Any alternative text (alt text) provided alongside figures in this article has been generated by Frontiers with the support of artificial intelligence and reasonable efforts have been made to ensure accuracy, including review by the authors wherever possible. If you identify any issues, please contact us.</p>
</sec>
<sec sec-type="disclaimer" id="s12">
<title>Publisher&#x2019;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<fn-group>
<fn fn-type="custom" custom-type="edited-by">
<p>
<bold>Edited by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/1769733/overview">Mark Heyland</ext-link>, Charit&#xe9; Medical University of Berlin, Germany</p>
</fn>
<fn fn-type="custom" custom-type="reviewed-by">
<p>
<bold>Reviewed by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/2184631/overview">Tianwei Xia</ext-link>, Affiliated Hospital of Nanjing University of Chinese Medicine, China</p>
<p>
<ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/3030429/overview">Weida Wu</ext-link>, Massachusetts Institute of Technology, United States</p>
</fn>
</fn-group>
<sec id="s13">
<title>Abbreviations</title>
<p>FNF, femoral neck fracture; FNS, femoral neck system; CS, cannulated screw; DHS, dynamic hip screw; FEA, finite element analysis; BMI, body mass index; TAD, Tip apex distance; SD, standard deviation.</p>
</sec>
<ref-list>
<title>References</title>
<ref id="B1">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bhandari</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Tornetta</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Hanson</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Swiontkowski</surname>
<given-names>M. F.</given-names>
</name>
</person-group> (<year>2009</year>). <article-title>Optimal internal fixation for femoral neck fractures: multiple screws or sliding hip screws?</article-title> <source>J. Orthop. Trauma</source> <volume>23</volume> (<issue>6</issue>), <fpage>403</fpage>&#x2013;<lpage>407</lpage>. <pub-id pub-id-type="doi">10.1097/bot.0b013e318176191f</pub-id>
<pub-id pub-id-type="pmid">19550225</pub-id>
</mixed-citation>
</ref>
<ref id="B2">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Chan</surname>
<given-names>D. S.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Femoral neck fractures in young patients: state of the art</article-title>. <source>J. Orthop. Trauma</source> <volume>33</volume> (<issue>Suppl. 1</issue>), <fpage>S7</fpage>&#x2013;<lpage>S11</lpage>. <pub-id pub-id-type="doi">10.1097/bot.0000000000001366</pub-id>
<pub-id pub-id-type="pmid">30540666</pub-id>
</mixed-citation>
</ref>
<ref id="B3">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Davidson</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Blum</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Harats</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Kachko</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Essa</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Efraty</surname>
<given-names>R.</given-names>
</name>
<etal/>
</person-group> (<year>2022</year>). <article-title>Neck of femur fractures treated with the femoral neck system: outcomes of one hundred and two patients and literature review</article-title>. <source>Int. Orthop.</source> <volume>46</volume> (<issue>9</issue>), <fpage>2105</fpage>&#x2013;<lpage>2115</lpage>. <pub-id pub-id-type="doi">10.1007/s00264-022-05414-0</pub-id>
<pub-id pub-id-type="pmid">35538322</pub-id>
</mixed-citation>
</ref>
<ref id="B4">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Felton</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Slobogean</surname>
<given-names>G. P.</given-names>
</name>
<name>
<surname>Jackson</surname>
<given-names>S. S.</given-names>
</name>
<name>
<surname>Della Rocca</surname>
<given-names>G. J.</given-names>
</name>
<name>
<surname>Liew</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Haverlag</surname>
<given-names>R.</given-names>
</name>
<etal/>
</person-group> (<year>2019</year>). <article-title>Femoral neck shortening after hip fracture fixation is associated with inferior hip function: results from the FAITH trial</article-title>. <source>J. Orthop. Trauma</source> <volume>33</volume> (<issue>10</issue>), <fpage>487</fpage>&#x2013;<lpage>496</lpage>. <pub-id pub-id-type="doi">10.1097/bot.0000000000001551</pub-id>
<pub-id pub-id-type="pmid">31464855</pub-id>
</mixed-citation>
</ref>
<ref id="B5">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Gao</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Ma</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Chang</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Jia</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Tang</surname>
<given-names>X.</given-names>
</name>
</person-group> (<year>2025</year>). <article-title>Femoral neck system (FNS) <italic>versus</italic> 4 cannulated compression screws (CCSs) in the treatment of young patients with pauwels type III femoral neck fracture: a retrospective comparative study</article-title>. <source>J. Orthop. Surg. Res.</source> <volume>20</volume> (<issue>1</issue>), <fpage>65</fpage>. <pub-id pub-id-type="doi">10.1186/s13018-025-05461-4</pub-id>
<pub-id pub-id-type="pmid">39827144</pub-id>
</mixed-citation>
</ref>
<ref id="B6">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Garden</surname>
<given-names>R. S.</given-names>
</name>
</person-group> (<year>1964</year>). <article-title>Stability And Union In Subcapital Fractures Of The Femur</article-title>. <source>J. Bone Jt. Surg. Br.</source> <volume>46</volume>, <fpage>630</fpage>&#x2013;<lpage>647</lpage>. <pub-id pub-id-type="doi">10.1302/0301-620x.46b4.630</pub-id>
<pub-id pub-id-type="pmid">14251448</pub-id>
</mixed-citation>
</ref>
<ref id="B7">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Gardner</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Weaver</surname>
<given-names>M. J.</given-names>
</name>
<name>
<surname>Jerabek</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Rodriguez</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Vrahas</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Harris</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2015</year>). <article-title>Predictors of early failure in young patients with displaced femoral neck fractures</article-title>. <source>J. Orthop.</source> <volume>12</volume> (<issue>2</issue>), <fpage>75</fpage>&#x2013;<lpage>80</lpage>. <pub-id pub-id-type="doi">10.1016/j.jor.2014.01.001</pub-id>
<pub-id pub-id-type="pmid">25972697</pub-id>
</mixed-citation>
</ref>
<ref id="B8">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Guo</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Huang</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Cai</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Cai</surname>
<given-names>T.</given-names>
</name>
</person-group> (<year>2024</year>). <article-title>Clinical efficacy of Femoral neck System for treatment of unstable femoral neck fractures in young adults</article-title>. <source>J. Int. Med. Res.</source> <volume>52</volume> (<issue>5</issue>), <fpage>03000605241238983</fpage>. <pub-id pub-id-type="doi">10.1177/03000605241238983</pub-id>
<pub-id pub-id-type="pmid">38729774</pub-id>
</mixed-citation>
</ref>
<ref id="B9">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Henschel</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Eberle</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Augat</surname>
<given-names>P.</given-names>
</name>
</person-group> (<year>2016</year>). <article-title>Load distribution between cephalic screws in a dual lag screw trochanteric nail</article-title>. <source>J. Orthop. Surg. Res.</source> <volume>11</volume>, <fpage>41</fpage>. <pub-id pub-id-type="doi">10.1186/s13018-016-0377-y</pub-id>
<pub-id pub-id-type="pmid">27039374</pub-id>
</mixed-citation>
</ref>
<ref id="B10">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hoshino</surname>
<given-names>C. M.</given-names>
</name>
<name>
<surname>Christian</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>O&#x2019;Toole</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Manson</surname>
<given-names>T.</given-names>
</name>
</person-group> (<year>2016</year>). <article-title>Fixation of displaced femoral neck fractures in young adults: fixed-Angle devices or pauwel screws?</article-title> <source>Injury</source> <volume>47</volume> (<issue>8</issue>), <fpage>1676</fpage>&#x2013;<lpage>1684</lpage>. <pub-id pub-id-type="doi">10.1016/j.injury.2016.03.014</pub-id>
<pub-id pub-id-type="pmid">27269418</pub-id>
</mixed-citation>
</ref>
<ref id="B11">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Huang</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Zhou</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>Y.</given-names>
</name>
<etal/>
</person-group> (<year>2023</year>). <article-title>Comparison of femoral neck system and three cannulated cancellous screws in the treatment of vertical femoral neck fractures: clinical observation and finite element analysis</article-title>. <source>Biomed. Eng. Online</source> <volume>22</volume> (<issue>1</issue>), <fpage>20</fpage>. <pub-id pub-id-type="doi">10.1186/s12938-023-01083-1</pub-id>
<pub-id pub-id-type="pmid">36859241</pub-id>
</mixed-citation>
</ref>
<ref id="B12">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Jiang</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Zhan</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Hai</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Zhao</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Zhu</surname>
<given-names>Z.</given-names>
</name>
<etal/>
</person-group> (<year>2023</year>). <article-title>What makes vertical femoral neck fracture with posterior inferior comminution different? An analysis of biomechanical features and optimal internal fixation strategy</article-title>. <source>Injury</source> <volume>54</volume> (<issue>8</issue>), <fpage>110842</fpage>. <pub-id pub-id-type="doi">10.1016/j.injury.2023.110842</pub-id>
<pub-id pub-id-type="pmid">37296009</pub-id>
</mixed-citation>
</ref>
<ref id="B13">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kwak</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Kim</surname>
<given-names>W. H.</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>S. J.</given-names>
</name>
<name>
<surname>Rhyu</surname>
<given-names>S. H.</given-names>
</name>
<name>
<surname>Jang</surname>
<given-names>C. Y.</given-names>
</name>
<name>
<surname>Yoo</surname>
<given-names>J. H.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Biomechanical comparison of three different intramedullary nails for fixation of unstable basicervical intertrochanteric fractures of the proximal femur: experimental studies</article-title>. <source>Biomed. Res. Int.</source> <volume>2018</volume>, <fpage>1</fpage>&#x2013;<lpage>9</lpage>. <pub-id pub-id-type="doi">10.1155/2018/7618079</pub-id>
<pub-id pub-id-type="pmid">30643821</pub-id>
</mixed-citation>
</ref>
<ref id="B14">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lazaro</surname>
<given-names>L. E.</given-names>
</name>
<name>
<surname>Birnbaum</surname>
<given-names>J. F.</given-names>
</name>
<name>
<surname>Farshad-Amacker</surname>
<given-names>N. A.</given-names>
</name>
<name>
<surname>Helfet</surname>
<given-names>D. L.</given-names>
</name>
<name>
<surname>Potter</surname>
<given-names>H. G.</given-names>
</name>
<name>
<surname>Lorich</surname>
<given-names>D. G.</given-names>
</name>
</person-group> (<year>2016</year>). <article-title>Endosteal biologic augmentation for surgical fixation of displaced femoral neck fractures</article-title>. <source>J. Orthop. Trauma</source> <volume>30</volume> (<issue>2</issue>), <fpage>81</fpage>&#x2013;<lpage>88</lpage>. <pub-id pub-id-type="doi">10.1097/bot.0000000000000452</pub-id>
<pub-id pub-id-type="pmid">26817574</pub-id>
</mixed-citation>
</ref>
<ref id="B15">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lee</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Lin</surname>
<given-names>K. J.</given-names>
</name>
<name>
<surname>Wei</surname>
<given-names>H. W.</given-names>
</name>
<name>
<surname>Hu</surname>
<given-names>J. J.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>W. C.</given-names>
</name>
<name>
<surname>Tsai</surname>
<given-names>C. L.</given-names>
</name>
<etal/>
</person-group> (<year>2016</year>). <article-title>Biomechanical effect of different femoral neck blade position on the fixation of intertrochanteric fracture: a finite element analysis</article-title>. <source>Biomed. Tech. Berl.</source> <volume>61</volume> (<issue>3</issue>), <fpage>331</fpage>&#x2013;<lpage>336</lpage>. <pub-id pub-id-type="doi">10.1515/bmt-2015-0091</pub-id>
<pub-id pub-id-type="pmid">26351785</pub-id>
</mixed-citation>
</ref>
<ref id="B16">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lee</surname>
<given-names>D. H.</given-names>
</name>
<name>
<surname>Kwon</surname>
<given-names>J. H.</given-names>
</name>
<name>
<surname>Kim</surname>
<given-names>K.</given-names>
</name>
</person-group> (<year>2024</year>). <article-title>The effects and risk factors of femoral neck shortening after internal fixation of femoral neck fractures</article-title>. <source>Clin. Orthop. Surg.</source> <volume>16</volume> (<issue>5</issue>), <fpage>718</fpage>&#x2013;<lpage>723</lpage>. <pub-id pub-id-type="doi">10.4055/cios24089</pub-id>
<pub-id pub-id-type="pmid">39364104</pub-id>
</mixed-citation>
</ref>
<ref id="B17">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lin</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Gong</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Lin</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Liu</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Zheng</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>P.</given-names>
</name>
<etal/>
</person-group> (<year>2024</year>). <article-title>Anti-shortening screw for the prevention of postoperative shortening in displaced femoral neck fractures: a retrospective cohort Study</article-title>. <source>Orthop. Surg.</source> <volume>16</volume> (<issue>12</issue>), <fpage>2967</fpage>&#x2013;<lpage>2975</lpage>. <pub-id pub-id-type="doi">10.1111/os.14232</pub-id>
<pub-id pub-id-type="pmid">39219035</pub-id>
</mixed-citation>
</ref>
<ref id="B18">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lin</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Lin</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Liu</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Zheng</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Lin</surname>
<given-names>C.</given-names>
</name>
</person-group> (<year>2025</year>). <article-title>Comparative efficacy of different anti-shortening screws in preventing postoperative shortening in displaced femoral neck fractures: a retrospective cohort study</article-title>. <source>J. Orthop. Surg. Res.</source> <volume>20</volume> (<issue>1</issue>), <fpage>400</fpage>. <pub-id pub-id-type="doi">10.1186/s13018-025-05822-z</pub-id>
<pub-id pub-id-type="pmid">40259399</pub-id>
</mixed-citation>
</ref>
<ref id="B19">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Liu</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Yin</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Sun</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>W.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Biomechanical evaluation of the modified cannulated screws fixation of unstable femoral neck fracture with comminuted posteromedial cortex</article-title>. <source>Biomed. Res. Int.</source> <volume>2019</volume>, <fpage>2584151</fpage>&#x2013;<lpage>2584158</lpage>. <pub-id pub-id-type="doi">10.1155/2019/2584151</pub-id>
<pub-id pub-id-type="pmid">31360707</pub-id>
</mixed-citation>
</ref>
<ref id="B20">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lotz</surname>
<given-names>J. C.</given-names>
</name>
<name>
<surname>Cheal</surname>
<given-names>E. J.</given-names>
</name>
<name>
<surname>Hayes</surname>
<given-names>W. C.</given-names>
</name>
</person-group> (<year>1995</year>). <article-title>Stress distributions within the proximal femur during gait and falls: implications for osteoporotic fracture</article-title>. <source>Osteoporos. Int.</source> <volume>5</volume> (<issue>4</issue>), <fpage>252</fpage>&#x2013;<lpage>261</lpage>. <pub-id pub-id-type="doi">10.1007/bf01774015</pub-id>
<pub-id pub-id-type="pmid">7492864</pub-id>
</mixed-citation>
</ref>
<ref id="B21">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ma</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Kuang</surname>
<given-names>M. j.</given-names>
</name>
<name>
<surname>Xing</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Zhao</surname>
<given-names>Y. l.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>H. t.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>L. k.</given-names>
</name>
<etal/>
</person-group> (<year>2018</year>). <article-title>Sliding hip screw <italic>versus</italic> cannulated cancellous screws for fixation of femoral neck fracture in adults: a systematic review</article-title>. <source>Int. J. Surg.</source> <volume>52</volume>, <fpage>89</fpage>&#x2013;<lpage>97</lpage>. <pub-id pub-id-type="doi">10.1016/j.ijsu.2018.01.050</pub-id>
<pub-id pub-id-type="pmid">29471156</pub-id>
</mixed-citation>
</ref>
<ref id="B22">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Parker</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Cawley</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Palial</surname>
<given-names>V.</given-names>
</name>
</person-group> (<year>2013</year>). <article-title>Internal fixation of intracapsular fractures of the hip using a dynamic locking plate: Two-year follow-up of 320 patients</article-title>. <source>Bone Jt. J.</source> <volume>95-B</volume> (<issue>10</issue>), <fpage>1402</fpage>&#x2013;<lpage>1405</lpage>. <pub-id pub-id-type="doi">10.1302/0301-620x.95b10.31511</pub-id>
<pub-id pub-id-type="pmid">24078540</pub-id>
</mixed-citation>
</ref>
<ref id="B23">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Rawall</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Bali</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Upendra</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Garg</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Yadav</surname>
<given-names>C. S.</given-names>
</name>
<name>
<surname>Jayaswal</surname>
<given-names>A.</given-names>
</name>
</person-group> (<year>2012</year>). <article-title>Displaced femoral neck fractures in the young: significance of posterior comminution and raised intracapsular pressure</article-title>. <source>Arch. Orthop. Trauma Surg.</source> <volume>132</volume> (<issue>1</issue>), <fpage>73</fpage>&#x2013;<lpage>79</lpage>. <pub-id pub-id-type="doi">10.1007/s00402-011-1395-1</pub-id>
<pub-id pub-id-type="pmid">21928054</pub-id>
</mixed-citation>
</ref>
<ref id="B24">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Robinson</surname>
<given-names>C. M.</given-names>
</name>
<name>
<surname>Court-Brown</surname>
<given-names>C. M.</given-names>
</name>
<name>
<surname>McQueen</surname>
<given-names>M. M.</given-names>
</name>
<name>
<surname>Christie</surname>
<given-names>J.</given-names>
</name>
</person-group> (<year>1995</year>). <article-title>Hip fractures in adults younger than 50 years of age. Epidemiology and results</article-title>. <source>Clin. Orthop. Relat. Res.</source> (<issue>312</issue>), <fpage>238</fpage>&#x2013;<lpage>246</lpage>.<pub-id pub-id-type="pmid">7634609</pub-id>
</mixed-citation>
</ref>
<ref id="B25">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Roser</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Collinge</surname>
<given-names>C. A.</given-names>
</name>
<name>
<surname>Giga</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Lebus</surname>
<given-names>G. F.</given-names>
</name>
<name>
<surname>Beltran</surname>
<given-names>M. J.</given-names>
</name>
<name>
<surname>Crist</surname>
<given-names>B.</given-names>
</name>
<etal/>
</person-group> (<year>2024</year>). <article-title>Optimal fixation strategies for displaced femoral neck fractures in patients 18-59 years of age: an analysis of 565 cases treated at 26 level 1 trauma centers</article-title>. <source>J. Orthop. Trauma</source> <volume>38</volume> (<issue>8</issue>), <fpage>403</fpage>&#x2013;<lpage>409</lpage>. <pub-id pub-id-type="doi">10.1097/bot.0000000000002828</pub-id>
<pub-id pub-id-type="pmid">39007655</pub-id>
</mixed-citation>
</ref>
<ref id="B26">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Samsami</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Saberi</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Sadighi</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Rouhi</surname>
<given-names>G.</given-names>
</name>
</person-group> (<year>2015</year>). <article-title>Comparison of three fixation methods for femoral neck fracture in young adults: experimental and numerical investigations</article-title>. <source>J. Med. Biol. Eng.</source> <volume>35</volume> (<issue>5</issue>), <fpage>566</fpage>&#x2013;<lpage>579</lpage>. <pub-id pub-id-type="doi">10.1007/s40846-015-0085-9</pub-id>
<pub-id pub-id-type="pmid">26500470</pub-id>
</mixed-citation>
</ref>
<ref id="B27">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Schuetze</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Burkhardt</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Pankratz</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Eickhoff</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Boehringer</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Degenhart</surname>
<given-names>C.</given-names>
</name>
<etal/>
</person-group> (<year>2023</year>). <article-title>Is new always better: comparison of the femoral neck system and the dynamic hip screw in the treatment of femoral neck fractures</article-title>. <source>Arch. Orthop. Trauma Surg.</source> <volume>143</volume> (<issue>6</issue>), <fpage>3155</fpage>&#x2013;<lpage>3161</lpage>. <pub-id pub-id-type="doi">10.1007/s00402-022-04551-w</pub-id>
<pub-id pub-id-type="pmid">35867115</pub-id>
</mixed-citation>
</ref>
<ref id="B28">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sensoz</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>&#xd6;zkal</surname>
<given-names>F. M.</given-names>
</name>
<name>
<surname>Acar</surname>
<given-names>V.</given-names>
</name>
<name>
<surname>Cakir</surname>
<given-names>F.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Finite element analysis of the impact of screw insertion distal to the trochanter minor on the risk of iatrogenic subtrochanteric fracture</article-title>. <source>Proc. Inst. Mech. Eng. H.</source> <volume>232</volume> (<issue>8</issue>), <fpage>807</fpage>&#x2013;<lpage>818</lpage>. <pub-id pub-id-type="doi">10.1177/0954411918789963</pub-id>
<pub-id pub-id-type="pmid">30028235</pub-id>
</mixed-citation>
</ref>
<ref id="B29">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Stoffel</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Zderic</surname>
<given-names>I.</given-names>
</name>
<name>
<surname>Gras</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Sommer</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Eberli</surname>
<given-names>U.</given-names>
</name>
<name>
<surname>Mueller</surname>
<given-names>D.</given-names>
</name>
<etal/>
</person-group> (<year>2017</year>). <article-title>Biomechanical evaluation of the femoral neck System in unstable pauwels III femoral neck fractures: a comparison with the dynamic hip screw and cannulated screws</article-title>. <source>J. Orthop. Trauma</source> <volume>31</volume> (<issue>3</issue>), <fpage>131</fpage>&#x2013;<lpage>137</lpage>. <pub-id pub-id-type="doi">10.1097/bot.0000000000000739</pub-id>
<pub-id pub-id-type="pmid">27755333</pub-id>
</mixed-citation>
</ref>
<ref id="B30">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Su</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>He</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Huang</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Lin</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Fang</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Dai</surname>
<given-names>Z.</given-names>
</name>
</person-group> (<year>2023</year>). <article-title>Superior short-term outcomes of FNS in combination with a cannulated screw in treating femoral neck fractures</article-title>. <source>BMC Musculoskelet. Disord.</source> <volume>24</volume> (<issue>1</issue>), <fpage>823</fpage>. <pub-id pub-id-type="doi">10.1186/s12891-023-06959-w</pub-id>
<pub-id pub-id-type="pmid">37853367</pub-id>
</mixed-citation>
</ref>
<ref id="B31">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Subasi</surname>
<given-names>O.</given-names>
</name>
<name>
<surname>Aslan</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Demirhan</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Seyahi</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Lazoglu</surname>
<given-names>I.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>A novel lower bound for tip-apex distance</article-title>. <source>Eur. J. Trauma Emerg. Surg.</source> <volume>48</volume> (<issue>3</issue>), <fpage>1787</fpage>&#x2013;<lpage>1798</lpage>. <pub-id pub-id-type="doi">10.1007/s00068-020-01514-x</pub-id>
<pub-id pub-id-type="pmid">33037920</pub-id>
</mixed-citation>
</ref>
<ref id="B32">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Windolf</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Braunstein</surname>
<given-names>V.</given-names>
</name>
<name>
<surname>Dutoit</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Schwieger</surname>
<given-names>K.</given-names>
</name>
</person-group> (<year>2009</year>). <article-title>Is a helical shaped implant a superior alternative to the dynamic Hip screw for unstable femoral neck fractures? A biomechanical investigation</article-title>. <source>Clin. Biomech. (Bristol)</source> <volume>24</volume> (<issue>1</issue>), <fpage>59</fpage>&#x2013;<lpage>64</lpage>. <pub-id pub-id-type="doi">10.1016/j.clinbiomech.2008.07.004</pub-id>
<pub-id pub-id-type="pmid">18977058</pub-id>
</mixed-citation>
</ref>
<ref id="B33">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Xin</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Pei</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Shi</surname>
<given-names>Q.</given-names>
</name>
<name>
<surname>Xiao</surname>
<given-names>L.</given-names>
</name>
</person-group> (<year>2023</year>). <article-title>The incidence and risk factors for femoral head necrosis after femoral neck fracture in pediatric patients: a systematic review and meta-analysis</article-title>. <source>J. Orthop. Surg. Res.</source> <volume>18</volume> (<issue>1</issue>), <fpage>22</fpage>. <pub-id pub-id-type="doi">10.1186/s13018-023-03502-4</pub-id>
<pub-id pub-id-type="pmid">36624532</pub-id>
</mixed-citation>
</ref>
<ref id="B34">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Xu</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Sun</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Huang</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Zhao</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Shao</surname>
<given-names>Y.</given-names>
</name>
<etal/>
</person-group> (<year>2024</year>). <article-title>Comparative analysis of the femoral neck system (FNS) vs. cannulated cancellous screws (CCS) in the treatment of middle-aged and elderly patients with femoral neck fractures: clinical outcomes and biomechanical insights</article-title>. <source>BMC Musculoskelet. Disord.</source> <volume>25</volume> (<issue>1</issue>), <fpage>735</fpage>. <pub-id pub-id-type="doi">10.1186/s12891-024-07863-7</pub-id>
<pub-id pub-id-type="pmid">39277709</pub-id>
</mixed-citation>
</ref>
<ref id="B35">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yang</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Lin</surname>
<given-names>L. C.</given-names>
</name>
<name>
<surname>Chao</surname>
<given-names>K. H.</given-names>
</name>
<name>
<surname>Chuang</surname>
<given-names>S. Y.</given-names>
</name>
<name>
<surname>Wu</surname>
<given-names>C. C.</given-names>
</name>
<name>
<surname>Yeh</surname>
<given-names>T. T.</given-names>
</name>
<etal/>
</person-group> (<year>2013</year>). <article-title>Risk factors for nonunion in patients with intracapsular femoral neck fractures treated with three cannulated screws placed in either a triangle or an inverted triangle configuration</article-title>. <source>J. Bone Jt. Surg. Am.</source> <volume>95</volume> (<issue>1</issue>), <fpage>61</fpage>&#x2013;<lpage>69</lpage>. <pub-id pub-id-type="doi">10.2106/jbjs.k.01081</pub-id>
<pub-id pub-id-type="pmid">23283374</pub-id>
</mixed-citation>
</ref>
<ref id="B36">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhou</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Lin</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Huang</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Gan</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Zhai</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Sun</surname>
<given-names>K.</given-names>
</name>
<etal/>
</person-group> (<year>2020</year>). <article-title>Modified cannulated screw fixation in the treatment of Pauwels type III femoral neck fractures: a biomechanical study</article-title>. <source>Clin. Biomech. (Bristol)</source> <volume>74</volume>, <fpage>103</fpage>&#x2013;<lpage>110</lpage>. <pub-id pub-id-type="doi">10.1016/j.clinbiomech.2020.02.016</pub-id>
<pub-id pub-id-type="pmid">32155446</pub-id>
</mixed-citation>
</ref>
<ref id="B37">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhou</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Xu</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>She</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>G.</given-names>
</name>
<etal/>
</person-group> (<year>2021</year>). <article-title>Comparison of early clinical results for femoral neck system and cannulated screws in the treatment of unstable femoral neck fractures</article-title>. <source>Orthop. Surg.</source> <volume>13</volume> (<issue>6</issue>), <fpage>1802</fpage>&#x2013;<lpage>1809</lpage>. <pub-id pub-id-type="doi">10.1111/os.13098</pub-id>
<pub-id pub-id-type="pmid">34351048</pub-id>
</mixed-citation>
</ref>
<ref id="B38">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhou</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Fan</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Lv</surname>
<given-names>Y.</given-names>
</name>
</person-group> (<year>2025</year>). <article-title>The proximal femoral universal nail system (PFUN): a novel intramedullary nail for treating complex proximal femoral fractures and its biomechanical comparison with the proximal femoral nail anti-rotation (PFNA)</article-title>. <source>J. Orthop. Surg. Res.</source> <volume>20</volume> (<issue>1</issue>), <fpage>317</fpage>. <pub-id pub-id-type="doi">10.1186/s13018-025-05724-0</pub-id>
<pub-id pub-id-type="pmid">40140851</pub-id>
</mixed-citation>
</ref>
<ref id="B39">
<mixed-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zlowodzki</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Ayieni</surname>
<given-names>O.</given-names>
</name>
<name>
<surname>Petrisor</surname>
<given-names>B. A.</given-names>
</name>
<name>
<surname>Bhandari</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2008</year>). <article-title>Femoral neck shortening after fracture fixation with multiple cancellous screws: incidence and effect on function</article-title>. <source>J. Trauma</source> <volume>64</volume> (<issue>1</issue>), <fpage>163</fpage>&#x2013;<lpage>169</lpage>. <pub-id pub-id-type="doi">10.1097/01.ta.0000241143.71274.63</pub-id>
<pub-id pub-id-type="pmid">18188116</pub-id>
</mixed-citation>
</ref>
</ref-list>
</back>
</article>