<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article article-type="review-article" dtd-version="2.3" xml:lang="EN" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Bioeng. Biotechnol.</journal-id>
<journal-title>Frontiers in Bioengineering and Biotechnology</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Bioeng. Biotechnol.</abbrev-journal-title>
<issn pub-type="epub">2296-4185</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">1613836</article-id>
<article-id pub-id-type="doi">10.3389/fbioe.2025.1613836</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Bioengineering and Biotechnology</subject>
<subj-group>
<subject>Mini Review</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>The potential of microfluidic cell analysis in CAR T cell therapy manufacturing</article-title>
<alt-title alt-title-type="left-running-head">Nikoniuk et al.</alt-title>
<alt-title alt-title-type="right-running-head">
<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3389/fbioe.2025.1613836">10.3389/fbioe.2025.1613836</ext-link>
</alt-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Nikoniuk</surname>
<given-names>Aleksandra</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/2552867/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Lilova</surname>
<given-names>Koki</given-names>
</name>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/supervision/"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Thomas</surname>
<given-names>Michael</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff3">
<sup>3</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/3203573/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/supervision/"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Szita</surname>
<given-names>Nicolas</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff4">
<sup>4</sup>
</xref>
<xref ref-type="corresp" rid="c001">&#x2a;</xref>
<uri xlink:href="https://loop.frontiersin.org/people/466507/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/supervision/"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
</contrib-group>
<aff id="aff1">
<sup>1</sup>
<institution>Department of Biochemical Engineering, UCL</institution>, <addr-line>London</addr-line>, <country>United Kingdom</country>
</aff>
<aff id="aff2">
<sup>2</sup>
<institution>Autolus Ltd.</institution>, <addr-line>London</addr-line>, <country>United Kingdom</country>
</aff>
<aff id="aff3">
<sup>3</sup>
<institution>London Centre for Nanotechnology, UCL</institution>, <addr-line>London</addr-line>, <country>United Kingdom</country>
</aff>
<aff id="aff4">
<sup>4</sup>
<institution>Young Owl Ltd</institution>, <addr-line>London</addr-line>, <country>United Kingdom</country>
</aff>
<author-notes>
<fn fn-type="edited-by">
<p>
<bold>Edited by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/634354/overview">Ralf P&#xf6;rtner</ext-link>, Hamburg University of Technology, Germany</p>
</fn>
<fn fn-type="edited-by">
<p>
<bold>Reviewed by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/1517870/overview">Zhaohua Hou</ext-link>, Memorial Sloan Kettering Cancer Center, United States</p>
<p>
<ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/1608450/overview">Subhash Kumar Tripathi</ext-link>, Seattle Children&#x2019;s Research Institute, United States</p>
<p>
<ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/1865711/overview">Gaurav Sutrave</ext-link>, The University of Sydney, Australia</p>
<p>
<ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/1955067/overview">Zhongjie Yu</ext-link>, Sino-Cell Biomed Co., Ltd., China</p>
<p>
<ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/3073481/overview">Alexandra Teixeira</ext-link>, International Iberian Nanotechnology Laboratory (INL), Portugal</p>
</fn>
<corresp id="c001">&#x2a;Correspondence: Nicolas Szita, <email>n.szita@ucl.ac.uk</email>
</corresp>
</author-notes>
<pub-date pub-type="epub">
<day>29</day>
<month>10</month>
<year>2025</year>
</pub-date>
<pub-date pub-type="collection">
<year>2025</year>
</pub-date>
<volume>13</volume>
<elocation-id>1613836</elocation-id>
<history>
<date date-type="received">
<day>17</day>
<month>04</month>
<year>2025</year>
</date>
<date date-type="accepted">
<day>01</day>
<month>09</month>
<year>2025</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#xa9; 2025 Nikoniuk, Lilova, Thomas and Szita.</copyright-statement>
<copyright-year>2025</copyright-year>
<copyright-holder>Nikoniuk, Lilova, Thomas and Szita</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p>
</license>
</permissions>
<abstract>
<p>Despite significant success in treating hematological cancers, Chimeric Antigen Receptor (CAR) T cell therapies must overcome several challenges to become accessible to a wide patient population. With the high cost of treatment stemming partly from the complexity of the manufacturing process, there is a need for radical innovation in the ways those therapies are made. A crucial aspect of the manufacturing process is quality control (QC), responsible for monitoring the quality of the drug product. The use of microfluidic technology, in which microchannels are designed and fabricated to achieve high control of liquids, can increase sensitivity, lower the Limit of Detection (LoD), and improve time-to-result of analytical assays. This review examines how recently developed microfluidic devices for T cell analysis fit the requirements of QC testing in CAR T cell manufacturing. A particular focus is on cell counting, cell phenotyping, and cytotoxicity assessments, where a range of microfluidic approaches have been taken to deliver reliable analytical assays. The review not only highlights current limitations of microfluidic devices that hinder their implementation in manufacturing, but also their potential to expand on current QC testing.</p>
</abstract>
<kwd-group>
<kwd>cell therapy manufacturing</kwd>
<kwd>microfluidics</kwd>
<kwd>critical quality attributes</kwd>
<kwd>quality control</kwd>
<kwd>CAR T cell</kwd>
<kwd>process analytical technologies (PAT)</kwd>
</kwd-group>
<contract-sponsor id="cn001">Royal Commission for the Exhibition of 1851<named-content content-type="fundref-id">10.13039/501100000700</named-content>
</contract-sponsor>
<counts>
<page-count count="13"/>
</counts>
<custom-meta-wrap>
<custom-meta>
<meta-name>section-at-acceptance</meta-name>
<meta-value>Cell and Gene Therapy</meta-value>
</custom-meta>
</custom-meta-wrap>
</article-meta>
</front>
<body>
<sec id="s1">
<title>1 Introduction</title>
<p>Chimeric Antigen Receptor (CAR) T cell therapies<xref ref-type="fn" rid="fn1">
<sup>1</sup>
</xref> are revolutionizing the treatment of hematological cancers, achieving high remission rates in previously unresponsive patients (<xref ref-type="bibr" rid="B20">Dagar et al., 2023</xref>). As of March 2025, seven CAR T cell therapies have been approved by the U.S. Food and Drug Administration (FDA), and hundreds more are in clinical trials across the world. However, their prohibitive price of USD 500k restricts their use for the population at large. The complex and often labor-intensive manufacturing process itself costs USD 170-220k per batch, and therefore per patient (<xref ref-type="bibr" rid="B38">Khang et al., 2023</xref>). The process requires highly specialized cell manipulations, starting with T cell purification and activation, through viral transduction, expansion and, finally, cryopreservation. Currently, skilled labor is employed to carry out these steps under Good Manufacturing Practice (GMP). The lack of automation adds to the overall cost not only in terms of operator remuneration but also batch failures caused by human error (<xref ref-type="bibr" rid="B56">Lopes and Sinclair, 2020</xref>). The key to successful process execution is quality control (QC), which informs of critical quality attributes (CQAs) at relevant process stages as well as on the final product profile. The CQAs outlined in <xref ref-type="table" rid="T1">Table 1</xref> can be divided into four categories. Safety encompasses attributes that can impact patient safety&#x2013;absence of bacteria (sterility, <italic>mycoplasma</italic>) and genetic stability of the transduced cells (Vector copy number, VCN; Replication-competent retrovirus/lentivirus, RCR/RCL). Identity defines the product&#x2013;what it looks like (visual appearance), dose (number of CAR T cells), and how many cells are viable (viability). Purity defines the cell content of the drug product&#x2013;the attributes quantify the presence of wanted (T cells, CAR-T cells) and unwanted cells (e.g., B cells, leukemic cells) or reagents (magnetic beads). Potency describes the ability of the drug product to target cancer cells, which includes assessing the percentage of cells that are CAR<sup>&#x2b;</sup> (CAR<sup>&#x2b;</sup> expression), how well they kill target cells (<italic>in vitro</italic> cytotoxicity) and trigger an immune response upon target encounter (cytokine release). Although efforts have been made in the advances in automation of cell processing steps with the introduction of the CliniMACS Prodigy or Lonza&#x2019;s Cocoon bioreactor systems, similar improvements have not yet been seen in QC (<xref ref-type="bibr" rid="B61">Mock et al., 2016</xref>; <xref ref-type="bibr" rid="B80">Trainor et al., 2023</xref>). As QC costs have been modelled to account for 32% of the cost of goods (COGs) (<xref ref-type="bibr" rid="B33">Harrison et al., 2019</xref>), a greater focus on analytical innovation could lead to significant savings.</p>
<table-wrap id="T1" position="float">
<label>TABLE 1</label>
<caption>
<p>Critical Quality Attributes (CQAs) in CAR T cell manufacturing with example specification.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="center">Category</th>
<th align="center">CQA</th>
<th align="center">Example specification</th>
<th align="center">Reference</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td rowspan="5" align="center">Safety</td>
<td align="center">Sterility</td>
<td align="center">Sterile</td>
<td align="center">USP/Ph. Eur<xref ref-type="table-fn" rid="Tfn1">
<sup>a</sup>
</xref>
</td>
</tr>
<tr>
<td align="center">
<italic>Mycoplasma</italic>
</td>
<td align="center">Negative</td>
<td align="center">USP/Ph. Eur<xref ref-type="table-fn" rid="Tfn1">
<sup>a</sup>
</xref>
</td>
</tr>
<tr>
<td align="center">Endotoxin</td>
<td align="center">&#x3c;0.5-3.5 EU/mL</td>
<td align="center">
<xref ref-type="bibr" rid="B59">Machietto et al. (2023),</xref> <xref ref-type="bibr" rid="B21">Delgado et al. (2022)</xref>
</td>
</tr>
<tr>
<td align="center">VCN</td>
<td align="center">&#x2264;4 copies/cell</td>
<td align="center">
<xref ref-type="bibr" rid="B34">Hollyman et al. (2009)</xref>
</td>
</tr>
<tr>
<td align="center">RCL</td>
<td align="center">Negative</td>
<td align="center">USP/Ph. Eur<xref ref-type="table-fn" rid="Tfn1">
<sup>a</sup>
</xref>
</td>
</tr>
<tr>
<td rowspan="3" align="center">Identity</td>
<td align="center">Visual appearance</td>
<td align="center">Cloudy liquid</td>
<td align="center">
<xref ref-type="bibr" rid="B21">Delgado et al. (2022)</xref>
</td>
</tr>
<tr>
<td align="center">Dose (from cell concentration)</td>
<td align="center">&#x3e;50 million CAR T cells</td>
<td align="center">
<xref ref-type="bibr" rid="B72">Rotte et al. (2022)</xref>
</td>
</tr>
<tr>
<td align="center">Viability</td>
<td align="center">&#x2265;70&#x2013;80%</td>
<td align="center">
<xref ref-type="bibr" rid="B34">Hollyman et al. (2009),</xref> <xref ref-type="bibr" rid="B21">Delgado et al. (2022)</xref>
</td>
</tr>
<tr>
<td rowspan="4" align="center">Purity</td>
<td align="center">CAR<sup>&#x2b;</sup> expression</td>
<td align="center">&#x2265;15%</td>
<td align="center">
<xref ref-type="bibr" rid="B29">Gee (2015)</xref>
</td>
</tr>
<tr>
<td align="center">CD19<sup>&#x2b;</sup> cell content</td>
<td align="center">&#x2264;2%</td>
<td align="center">
<xref ref-type="bibr" rid="B29">Gee (2015)</xref>
</td>
</tr>
<tr>
<td align="center">CD3<sup>&#x2b;</sup> cell content</td>
<td align="center">&#x2265;90%</td>
<td align="center">
<xref ref-type="bibr" rid="B11">Castella et al. (2020)</xref>
</td>
</tr>
<tr>
<td align="center">Other impurities e.g. magnetic beads</td>
<td align="center">&#x3c;100 beads per 3 &#xd7; 10<sup>6</sup> cells</td>
<td align="center">
<xref ref-type="bibr" rid="B34">Hollyman et al. (2009)</xref>
</td>
</tr>
<tr>
<td rowspan="3" align="center">Potency</td>
<td align="center">CAR<sup>&#x2b;</sup> expression</td>
<td align="center">&#x2265;15%</td>
<td align="center">
<xref ref-type="bibr" rid="B29">Gee (2015)</xref>
</td>
</tr>
<tr>
<td align="center">Cytokine release</td>
<td align="center">1&#x2013;10&#xa0;ng/mL</td>
<td align="center">
<xref ref-type="bibr" rid="B11">Castella et al. (2020)</xref>
</td>
</tr>
<tr>
<td align="center">
<italic>In vitro</italic> cytotoxicity</td>
<td align="center">&#x3e;20%</td>
<td align="center">
<xref ref-type="bibr" rid="B29">Gee (2015)</xref>
</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn id="Tfn1">
<label>
<sup>a</sup>
</label>
<p>Testing requirements are outlined in the United States Pharmacopoeia (USP) and European Pharmacopoeia.</p>
</fn>
</table-wrap-foot>
</table-wrap>
<sec id="s1-1">
<title>1.1 CQA assessments in CAR T cell therapy manufacturing</title>
<sec id="s1-1-1">
<title>1.1.1 Safety</title>
<p>In the early CAR T cell therapy clinical trials, safety testing was adopted from the pharmaceutical industry, following the compendial methods outlined in the United States and European Pharmacopoeias (<xref ref-type="bibr" rid="B28">Gebo and Lau, 2020</xref>). Sterility testing involves culturing samples in growth media for an extended period of time (14&#x2013;28&#xa0;days) and subsequently detecting contamination through either visual inspection or a colourimetric signal. BacT/Alert or Bactec are examples of FDA-validated, commercially available sterility testing methods that follow the compendial guidance, whilst standardizing the procedure (<xref ref-type="bibr" rid="B48">Lin-Gibson et al., 2021</xref>). However, the assay duration remains extensive, which contributes to the vein-to-vein time; hence, a recent focus has been on the development of rapid testing methods. Examples include the PCR-based detection of bacterial ribosomal DNA within 24&#xa0;h (<xref ref-type="bibr" rid="B84">Van Den Bos et al., 2023</xref>) and the Microsart ATMP Sterile Release kit developed by Sartorius, which can deliver results in 3&#xa0;h (<xref ref-type="bibr" rid="B23">Dias et al., 2024</xref>). Further approaches include mass spectrometry, Enzyme-linked Immunosorbent Assay (ELISA), next-generation sequencing (NGS), or flow cytometry-based methods, the advantages and disadvantages of which have been discussed elsewhere (<xref ref-type="bibr" rid="B48">Lin-Gibson et al., 2021</xref>).</p>
<p>The compendial <italic>mycoplasma</italic> detection method specifies three assays&#x2013;culture in broth, agar, and in fluorescently labelled eukaryotic cells - and takes up to 28&#xa0;days (<xref ref-type="bibr" rid="B28">Gebo and Lau, 2020</xref>). Rapid microbial methods based on nucleic acid amplification have been developed and are accepted by the regulatory authorities if appropriately validated (<xref ref-type="bibr" rid="B60">Marton et al., 2025</xref>). Those commercially available kits can deliver results in as fast as 1&#x2013;5&#xa0;h. To follow the strict GMP guidelines, the assays are carried out in specialized microbiology facilities, adding to the complexity and cost of manufacturing operations, as well as extending the time-to-result (<xref ref-type="bibr" rid="B23">Dias et al., 2024</xref>). Alternatively, the use of commercial kits can be implemented in-house; however, internal validation must be performed (<xref ref-type="bibr" rid="B60">Marton et al., 2025</xref>).</p>
<p>The compendial method for endotoxin detection utilizes the Limulus Amoebocyte Lysate (LAL), which, upon contact with endotoxin, forms a gel or produces a dye. The detection of this change indicates the presence of endotoxin in the sample. The assay has been incorporated into a cartridge compatible with detection via a hand-held spectrophotometer (Endosafe nexgen-PTS) for ease of operation (<xref ref-type="bibr" rid="B7">Barry et al., 2020</xref>). Validation of the assay for release testing is crucial, as the highly heterogeneous nature of the CAR T cell product can interfere with the LAL-endotoxin reaction (<xref ref-type="bibr" rid="B60">Marton et al., 2025</xref>).</p>
</sec>
<sec id="s1-1-2">
<title>1.1.2 Potency</title>
<p>The Chromium-51 (<sup>51</sup>Cr) release assay is used to measure cytotoxic activity by detecting the radioactive chromium in the supernatant, following a co-culture of <sup>51</sup>Cr-loaded target cells with effector cells (<xref ref-type="bibr" rid="B9">Cao et al., 2024</xref>). To improve operator safety and reduce radioactive waste, alternative detection methods such as flow cytometry or cell imaging are utilized following the target-effector (T-E) co-culture (<xref ref-type="bibr" rid="B39">Kiesgen et al., 2021</xref>). Flow cytometry offers endpoint analysis, where different cell populations are detected and compared to starting T-E ratios. Imaging systems like Incucyte offer real-time monitoring of cell death; however, they require fluorescent labelling of cells. The development of the xCELLigence platform, which utilizes impedance to detect cell killing in a co-culture, offers manufacturers label-free real-time data acquisition capabilities (<xref ref-type="bibr" rid="B49">Lisby et al., 2022</xref>).</p>
<p>Typically, cytokine secretion is detected using methods such as ELISA or ELISpot. Flow cytometry or the Luminex technology, which combines the two, can also be utilized (<xref ref-type="bibr" rid="B60">Marton et al., 2025</xref>). These are lengthy and labor-intensive assays; therefore, the development of automated immunoassays, such as ELLA developed by ProteinSimple, is a welcome improvement. The measurement of IFN-&#x3b3; production following CAR T cell stimulation as an indicator of CAR T cell potency is accepted by the regulatory agencies; however, it is recommended that a cell killing assay and measurement of transduction efficiency be carried out as well (<xref ref-type="bibr" rid="B26">FDA, 2024</xref>).</p>
</sec>
<sec id="s1-1-3">
<title>1.1.3 Identity and purity</title>
<p>Identity and purity assessments are performed utilizing a range of cell counting methods from Trypan blue (<xref ref-type="bibr" rid="B34">Hollyman et al., 2009</xref>) to automated cell counters (<xref ref-type="bibr" rid="B55">Liu et al., 2024</xref>). Flow cytometry is a key analytical technique to assess the expression of cell surface markers (<xref ref-type="bibr" rid="B11">Castella et al., 2020</xref>), which defines the purity of the cell population, e.g., how many of the cells are CD3<sup>&#x2b;</sup> and therefore T cells. The combination of cell counting and expression of surface proteins aids in calculations identifying the product, e.g., defining the CAR T cell dose.</p>
</sec>
</sec>
<sec id="s1-2">
<title>1.2 Benefits of microfluidics</title>
<p>Microfluidic technology offers excellent spatiotemporal control, over the cellular microenvironment short diffusion path lengths, and operates at low volumes, meaning reduced use of resources (<xref ref-type="bibr" rid="B75">Sekhwama et al., 2024</xref>). These advantages can increase sensitivity, lower the Limit of Detection (LoD), and improve the time-to-result of analytical assays. Operating at the microscale could reduce sample and reagent use, which, when coupled with automation capabilities, could reduce costs associated with QC testing and ultimately CAR T cell therapies. The large number of analytical techniques could be combined in a microfluidic system as proposed in <xref ref-type="fig" rid="F1">Figure 1</xref>. Unit operations such as Peripheral Blood Mononuclear Cells (PBMCs) separation from whole blood, T cell isolation, gene delivery, as well as functionality assessments, have already been translated into microfluidic devices (<xref ref-type="bibr" rid="B1">Aranda Hernandez et al., 2021</xref>; <xref ref-type="bibr" rid="B85">Wang and Kelley, 2025</xref>; <xref ref-type="bibr" rid="B40">Kim et al., 2024</xref>; <xref ref-type="bibr" rid="B94">Zia et al., 2024</xref>).</p>
<fig id="F1" position="float">
<label>FIGURE 1</label>
<caption>
<p>The potential of microfluidics in Critical Quality Attribute (CQA) assessment in CAR T cell therapy manufacturing. CQAs are assessed by a range of analytical methods, which include flow cytometry, microscopy, impedance-based real-time cell analysis, qPCR, and Enzyme-Linked Immunosorbent Assay (ELISA). They require trained scientists to operate and analyse results. Microfluidic technology could combine multiple analytical assays into automated devices with integrated readouts, decreasing the complexity of QC testing. Created in BioRender <ext-link ext-link-type="uri" xlink:href="https://BioRender.com/wts7pai">https://BioRender.com/wts7pai</ext-link>.</p>
</caption>
<graphic xlink:href="fbioe-13-1613836-g001.tif">
<alt-text content-type="machine-generated">Diagram illustrating a semi-automated cell processing platform alongside various analytical methods such as flow cytometry, impedance-based real-time cell analysis, ELISA, qPCR, and microscopy. An hourglass and researchers in lab coats symbolise time and the need for multiple operators to be involved in running all those assays. The combination of microfluidics coupled with optical and electrical detection can be used to quantify the following: CAR expression, cytokine release, and magnetic bead content. Features of such a system include quantitative results, automated operation, integrated sample preparation, and online detection.</alt-text>
</graphic>
</fig>
<p>This mini review presents how different technologies, namely droplet microfluidics, surface cell capture, electrical detection, physical parameter detection, and microwells, are used in microfluidic devices to detect cellular attributes related to identity, purity and potency; safety testing is outside the scope of this review as its challenges are not T cell specific. Furthermore, the review assesses whether the devices, in their current format, can be readily integrated into CAR T cell QC testing routines or whether any shortcomings need to be addressed before successful implementation.</p>
</sec>
</sec>
<sec id="s2">
<title>2 Droplet microfluidics as a tool for cell and reagent co-localization</title>
<p>Droplet microfluidics, a technique where sub-microliter droplets are generated, manipulated, and controlled within an immiscible carrier fluid, offers a range of applications for cell analysis (<xref ref-type="bibr" rid="B45">Li et al., 2023</xref>). Single cells or groups of cells can be enclosed within droplets, which allows for tracking of their behavior over time. Each droplet forms a distinct microscale cell culture chamber, offering a significant increase in experimental throughput.</p>
<sec id="s2-1">
<title>2.1 Cytokine release quantification</title>
<p>Cytokine release is an indicator of CAR T cell functionality and is therefore one of the CQAs (<xref ref-type="table" rid="T1">Table 1</xref>). Cells and microbeads functionalized against IL-10 cytokine were co-encapsulated with a fluorescently tagged detection antibody to quantify cytokine secretion at concentrations as low as 10&#xa0;pg mL<sup>&#x2212;1</sup> (<xref ref-type="bibr" rid="B41">Konry et al., 2011</xref>). Similarly, antibody-coated nanoparticles were enclosed inside a droplet alongside T cells and detection antibody, imaged, and analysed using an automated image processing algorithm (<xref ref-type="bibr" rid="B8">Bounab et al., 2020</xref>). <xref ref-type="bibr" rid="B57">Lu et al. (2024)</xref> utilized DNA proximity assay (DPA) within their microfluidic platform iSECRETE, capable of sample preparation, incubation, and quantification of IFN-&#x3b3; at limits of detection (LoD) of 0.13&#xa0;ng mL<sup>&#x2212;1</sup>. Within 30&#xa0;min, the signal was detected from processing 20&#xa0;&#xb5;L of a highly heterogeneous sample of whole blood. The system was expanded for CAR T cell cytotoxicity testing by incorporating further fluorescence markers within the droplet. These devices integrate sample processing and on-chip detection to provide sensitive results in the relevant range (<xref ref-type="table" rid="T1">Table 1</xref>), highlighting their potential as analytical systems for a manufacturing setting.</p>
<p>Surface-Enhanced Raman Spectroscopy (SERS) is a highly sensitive detection method that enhances Raman spectra when analytes of interest are in close proximity to plasmonically active metallic interfaces (<xref ref-type="bibr" rid="B46">Lian et al., 2025</xref>). It is used in the development of biosensors and offers the capability of both labelled and label-free detection formats. Its incorporation into microfluidic devices is understood to increase the reproducibility and accuracy of analyses because of the controlled conditions with which analytes are delivered and interface with plasmonic surfaces in the enclosed microfluidic environment.</p>
<p>In the context of cytokine detection, a relevant example of microfluidic labelled-SERS is the sandwich immunoassay developed by <xref ref-type="bibr" rid="B19">Cong et al. (2022)</xref> for the detection of vascular endothelial growth factor (VEGF). While for application in CAR T cell manufacturing, the VEGF antibody would have to be replaced with one against a relevant cytokine, e.g. IFN-&#x3b3;, the assay for VEGF provided a highly sensitive result in the range of pg mL<sup>&#x2212;1</sup>. Whilst sensitive, the approach required extensive cell sample preparation off-chip, two separate devices, as well as expensive and bulky confocal Raman detection equipment. When balancing assay sensitivity with its complexity and ease of operation, the latter might be the priority when introducing innovative solutions into CAR T cell manufacturing.</p>
</sec>
<sec id="s2-2">
<title>2.2 Cytotoxicity assessment</title>
<p>On top of cytokine secretion quantification, cell-based cytotoxicity assays are required by the regulators, which typically involve co-culture of CAR T cells with a cell line expressing the target surface marker. A droplet microfluidic device was developed to assess the killing potential of CD8<sup>&#x2b;</sup> T cells through measurement of calcium flux or machine learning-assisted detection of fluorescence (<xref ref-type="bibr" rid="B73">Sarkar et al., 2016</xref>; <xref ref-type="bibr" rid="B74">Sarkar et al., 2020</xref>; <xref ref-type="bibr" rid="B79">Sullivan et al., 2020</xref>). Despite providing a relevant analytical result, their device required sample preparation prior to the microfluidic assay as well as manual processing. Recently, a commercial microfluidic device was utilized to encapsulate CAR T cells with target cells for cytotoxicity testing, yet the assay readout was performed manually off-chip (<xref ref-type="bibr" rid="B83">Usheva et al., 2025</xref>). These devices show promise in delivering complex assessments of T cell killing potential, however, they fall short of integrating sample preparation, online detection, or assay automation (<xref ref-type="table" rid="T2">Table 2</xref>), critical in enhancing the efficiency of CAR T cell manufacturing.</p>
<table-wrap id="T2" position="float">
<label>TABLE 2</label>
<caption>
<p>Microfluidic devices and their suitability to QC testing in the CAR T cell manufacturing setting.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="center">System category</th>
<th align="center">Critical quality attribute (CQA)</th>
<th align="center">Assay</th>
<th align="center">Quantitative result</th>
<th align="center">Automated operation</th>
<th align="center">Integrated sample preparation</th>
<th align="center">On-chip detection</th>
<th align="center">Reference</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td rowspan="9" align="left">Droplet microfluidics</td>
<td rowspan="8" align="left">Potency</td>
<td align="left">VEGF detection</td>
<td align="center">Yes</td>
<td align="center">No</td>
<td align="center">No</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B19">Cong et al. (2022)</xref>
</td>
</tr>
<tr>
<td align="left">T cell cytotoxicity</td>
<td align="center">Yes</td>
<td align="center">No</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B70">Ronteix et al. (2022)</xref>
</td>
</tr>
<tr>
<td align="left">Detection of IFN-&#x3b3;, T cell cytotoxicity</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B57">Lu et al. (2024)</xref>
</td>
</tr>
<tr>
<td align="left">Detection of IL-10</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B41">Konry et al. (2011)</xref>
</td>
</tr>
<tr>
<td align="left">Detection of TNF-&#x3b1;, IFN-&#x3b3;, IL-2, IL-4</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B8">Bounab et al. (2020)</xref>
</td>
</tr>
<tr>
<td align="left">T cell cytotoxicity</td>
<td align="center">Yes</td>
<td align="center">No</td>
<td align="center">No</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B73">Sarkar et al. (2016),</xref> <xref ref-type="bibr" rid="B79">Sullivan et al. (2020),</xref> <xref ref-type="bibr" rid="B74">Sarkar et al. (2020)</xref>
</td>
</tr>
<tr>
<td align="left">T cell cytotoxicity</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">No</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B88">Wong et al. (2022)</xref>
</td>
</tr>
<tr>
<td align="left">CAR T cell cytotoxicity, detection of Granzyme B</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">No</td>
<td align="center">No</td>
<td align="left">
<xref ref-type="bibr" rid="B83">Usheva et al. (2025)</xref>
</td>
</tr>
<tr>
<td align="left">Purity</td>
<td align="left">3D cell imaging</td>
<td align="center">Yes</td>
<td align="center">No</td>
<td align="center">Yes</td>
<td align="center">No</td>
<td align="left">
<xref ref-type="bibr" rid="B10">Cardenas-Benitez et al. (2024)</xref>
</td>
</tr>
<tr>
<td rowspan="8" align="left">Surface modification for cell capture</td>
<td align="left">Potency</td>
<td align="left">Detection of IFN-&#x3b3; and IL-2</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B5">Baganizi et al. (2015)</xref>
</td>
</tr>
<tr>
<td rowspan="7" align="left">Purity</td>
<td align="left">CD4<sup>&#x2b;</sup> T cell counting</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">No</td>
<td align="left">
<xref ref-type="bibr" rid="B12">Cheng et al. (2007),</xref> <xref ref-type="bibr" rid="B13">Cheng et al. (2009)</xref>
</td>
</tr>
<tr>
<td align="left">CD4<sup>&#x2b;</sup> T cell counting</td>
<td align="center">Yes</td>
<td align="center">No</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B63">Moon et al. (2011)</xref>
</td>
</tr>
<tr>
<td align="left">CD4<sup>&#x2b;</sup> T cell counting</td>
<td align="center">Yes</td>
<td align="center">N/A</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B36">Kanakasabapathy et al. (2017)</xref>
</td>
</tr>
<tr>
<td align="left">CD19<sup>&#x2b;</sup>, CD4<sup>&#x2b;</sup> and CD71<sup>&#x2b;</sup> cell counting</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B42">Li et al. (2012),</xref> <xref ref-type="bibr" rid="B51">Liu et al. (2014),</xref> <xref ref-type="bibr" rid="B90">Zhang and Pappas (2016)</xref>
</td>
</tr>
<tr>
<td align="left">CD4<sup>&#x2b;</sup>/CD8<sup>&#x2b;</sup> cell counting</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">No</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B44">Li et al. (2015)</xref>
</td>
</tr>
<tr>
<td align="left">CD64<sup>&#x2b;</sup>. CD69<sup>&#x2b;</sup>, CD25<sup>&#x2b;</sup> cell counting</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">No</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B91">Zhang et al. (2018),</xref> <xref ref-type="bibr" rid="B92">Zhou et al. (2019),</xref> <xref ref-type="bibr" rid="B31">Griffin et al. (2025)</xref>
</td>
</tr>
<tr>
<td align="left">CD8<sup>&#x2b;</sup>CD57<sup>&#x2b;</sup> cell counting</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B14">Choi et al. (2024)</xref>
</td>
</tr>
<tr>
<td rowspan="11" align="left">Electrical detection</td>
<td rowspan="2" align="left">Potency</td>
<td align="left">Jurkat dose-response cytotoxicity</td>
<td align="center">Yes</td>
<td align="center">No</td>
<td align="center">No</td>
<td align="center">No</td>
<td align="left">
<xref ref-type="bibr" rid="B6">Barbulovic-Nad et al. (2008)</xref>
</td>
</tr>
<tr>
<td align="left">Detection of IFN-&#x3b3; and TNF-&#x3b1;</td>
<td align="center">Yes</td>
<td align="center">N/A</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B50">Liu et al. (2011),</xref> <xref ref-type="bibr" rid="B52">Liu et al. (2015)</xref>
</td>
</tr>
<tr>
<td rowspan="9" align="left">Purity</td>
<td align="left">CD4<sup>&#x2b;</sup> T cell counting</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B67">Phi et al. (2025)</xref>
</td>
</tr>
<tr>
<td align="left">Lymphocytes, monocytes, and granulocytes counting</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B53">Liu et al. (2019),</xref> <xref ref-type="bibr" rid="B54">Liu et al. (2020),</xref> <xref ref-type="bibr" rid="B16">Civelekoglu et al. (2022a)</xref>
</td>
</tr>
<tr>
<td align="left">CD4<sup>&#x2b;</sup> and CD8<sup>&#x2b;</sup> cell counting</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B87">Watkins et al. (2013)</xref>
</td>
</tr>
<tr>
<td align="left">Detection of EpCAM</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">No</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B15">Civelekoglu et al. (2019),</xref> <xref ref-type="bibr" rid="B18">Civelekoglu et al. (2022c)</xref>
</td>
</tr>
<tr>
<td align="left">Lymphocytes, monocytes, granulocytes counting</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">No</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B17">Civelekoglu et al. (2022b)</xref>
</td>
</tr>
<tr>
<td align="left">CD4<sup>&#x2b;</sup> and CD8<sup>&#x2b;</sup> cell counting</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B2">Arifuzzman et al. (2023)</xref>
</td>
</tr>
<tr>
<td align="left">Detection of apoptotic cells</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B3">Arifuzzman et al. (2025)</xref>
</td>
</tr>
<tr>
<td align="left">CD4<sup>&#x2b;</sup> cell counting</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">No</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B86">Wang et al. (2008)</xref>
</td>
</tr>
<tr>
<td align="left">Erythrocyte counting</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">N/A</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B65">Panwar and Roy (2019)</xref>
</td>
</tr>
<tr>
<td rowspan="4" align="left">Physical properties detection</td>
<td rowspan="4" align="left">Purity</td>
<td align="left">Monocyte and lymphocyte detection</td>
<td align="center">No</td>
<td align="center">Yes</td>
<td align="center">N/A</td>
<td align="center">No</td>
<td align="left">
<xref ref-type="bibr" rid="B37">Kang et al. (2018)</xref>
</td>
</tr>
<tr>
<td align="left">CD45<sup>&#x2b;</sup>, CD3<sup>&#x2b;</sup> and CD19<sup>&#x2b;</sup> cell detection</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">N/A</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B64">Noor et al. (2018),</xref> <xref ref-type="bibr" rid="B62">Mohd Noor et al. (2020)</xref>
</td>
</tr>
<tr>
<td align="left">CD4<sup>&#x2b;</sup> and CD8<sup>&#x2b;</sup> cell detection</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">No</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B71">Rossi et al. (2019)</xref>
</td>
</tr>
<tr>
<td align="left">Leukocyte counting</td>
<td align="center">Yes</td>
<td align="center">No</td>
<td align="center">No</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B35">Hosokawa et al. (2012)</xref>
</td>
</tr>
<tr>
<td rowspan="7" align="left">Microwells</td>
<td rowspan="7" align="left">Potency</td>
<td align="left">Detection of TNF-&#x3b1;, IFN-&#x3b3;, MCP-1, GM-CSF, IL-1&#x3b2;, IL-6</td>
<td align="center">Yes</td>
<td align="center">No</td>
<td align="center">No</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B58">Ma et al. (2023)</xref>
</td>
</tr>
<tr>
<td align="left">NK cell cytotoxicity</td>
<td align="center">Yes</td>
<td align="center">No</td>
<td align="center">No</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B66">Park et al. (2019)</xref>
</td>
</tr>
<tr>
<td align="left">Detection of Granzyme B, IFN&#x3b3;, MIP-1&#x3b1;, TNF-&#x3b1;, GM-CSF, IL-2, IL-8, IL-4, IL-13, IL-22, IL-6, IL-17A</td>
<td align="center">Yes</td>
<td align="center">No</td>
<td align="center">No</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B89">Xue et al. (2017)</xref>
</td>
</tr>
<tr>
<td align="left">Detection of IFN-&#x3b3;</td>
<td align="center">Yes</td>
<td align="center">N/A</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B76">Son et al. (2016)</xref>
</td>
</tr>
<tr>
<td align="left">Cytotoxicity, detection of IFN-&#x3b3;</td>
<td align="center">Yes</td>
<td align="center">No</td>
<td align="center">No</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B93">Zhou et al. (2020)</xref>
</td>
</tr>
<tr>
<td align="left">T cell cytotoxicity</td>
<td align="center">Yes</td>
<td align="center">N/A</td>
<td align="center">No</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B82">Tu et al. (2020)</xref>
</td>
</tr>
<tr>
<td align="left">Detection of IL-1&#x3b1;, IL-1&#x3b2;, IL-6, IL-8, IL-10, IL-12, IL-15, IL17A, TNF-&#x3b1;, IFN-&#x3b3;, MCP-1</td>
<td align="center">Yes</td>
<td align="center">No</td>
<td align="center">No</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B78">Song et al. (2021)</xref>
</td>
</tr>
<tr>
<td rowspan="8" align="left">Other</td>
<td rowspan="2" align="left">Potency</td>
<td align="left">T cell counting</td>
<td align="center">Yes</td>
<td align="center">No</td>
<td align="center">No</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B77">Song et al. (2019)</xref>
</td>
</tr>
<tr>
<td align="left">CD4<sup>&#x2b;</sup> T cell counting</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B68">Qiu et al. (2018)</xref>
</td>
</tr>
<tr>
<td rowspan="6" align="left">Purity</td>
<td align="left">Capture of T cells for SERS</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">No</td>
<td align="center">No</td>
<td align="left">
<xref ref-type="bibr" rid="B22">Dey et al. (2019)</xref>
</td>
</tr>
<tr>
<td align="left">CD4<sup>&#x2b;</sup> T cell counting</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">No</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B69">Rodriguez et al. (2005)</xref>
</td>
</tr>
<tr>
<td align="left">CD4<sup>&#x2b;</sup> T cell counting</td>
<td align="center">Yes</td>
<td align="center">No</td>
<td align="center">No</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B4">Bae et al. (2009)</xref>
</td>
</tr>
<tr>
<td align="left">CD4<sup>&#x2b;</sup> T cell counting</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">No</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B27">Frankowski et al. (2013)</xref>
</td>
</tr>
<tr>
<td align="left">Macrophage cell line counting</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">No</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B24">Fan et al. (2019),</xref> <xref ref-type="bibr" rid="B25">Fan et al. (2020)</xref>
</td>
</tr>
<tr>
<td align="left">Cell line counting</td>
<td align="center">Yes</td>
<td align="center">Yes</td>
<td align="center">No</td>
<td align="center">Yes</td>
<td align="left">
<xref ref-type="bibr" rid="B47">Liang et al. (2022)</xref>
</td>
</tr>
</tbody>
</table>
</table-wrap>
</sec>
<sec id="s2-3">
<title>2.3 Beyond CQA analysis</title>
<p>Some microfluidic systems are capable of quantification of relevant CQAs whilst also providing additional analysis. <xref ref-type="bibr" rid="B88">Wong et al. (2022)</xref> encapsulated CAR T cells with target cells for cytotoxicity measurement, and at the same time monitored CAR T response to target cells, such as whether the killing behavior was exhibited by single cells or clusters, or if CAR T cells expanded when exposed to their targets. However, image collection and analysis were manual, and the assay was tested using only two CAR T cell batches, indicating further validation is needed for employment in a manufacturing setting. Similarly, the device developed by <xref ref-type="bibr" rid="B74">Sarkar et al. (2020)</xref> is capable of not only cytotoxicity measurement but also monitoring of cell-to-cell contact times, the killing time, and the capacity for repeated killing. Microfluidic droplets have also been used to assess T cell killing behavior in complex tumor structures, which is relevant in developing analytics for CAR T cells targeting solid tumors (<xref ref-type="bibr" rid="B70">Ronteix et al., 2022</xref>). <xref ref-type="bibr" rid="B10">Cardenas-Benitez et al. (2024)</xref> developed a trapping device for 3D imaging of cells inside rotating droplets, providing detailed phenotyping data. However, to detect a specific T cell marker, the sample had to be fluorescently labelled off-chip. These examples show that microfluidic technology can assess relevant CQAs while providing additional information; however, it remains to be seen whether such additional testing will ever become a requirement in CAR T cell process monitoring and release testing.</p>
</sec>
</sec>
<sec id="s3">
<title>3 Microfluidic surface modification for cell capture and detection</title>
<p>One approach to microfluidic cell quantification is target cell capture via antibodies immobilized on a device&#x2019;s surface, followed by detection of either bound or unbound cell fraction. This approach was taken to quantify CD4<sup>&#x2b;</sup> T cells by counting surface-bound cells using microscopy (<xref ref-type="bibr" rid="B12">Cheng et al., 2007</xref>; <xref ref-type="bibr" rid="B13">Cheng et al., 2009</xref>). Alternatively, Charge-Coupled Device (CCD) cameras (<xref ref-type="bibr" rid="B63">Moon et al., 2011</xref>) or smartphones (<xref ref-type="bibr" rid="B36">Kanakasabapathy et al., 2017</xref>) can also be implemented to image surface-bound CD4<sup>&#x2b;</sup> T cells, with software integrated for image processing. Good statistical agreement was shown between the microfluidic methods and flow cytometry, as well as good sensitivity (over 80%) at relevant sample concentrations (up to 5 &#xd7; 10<sup>6</sup> cells mL<sup>&#x2212;1</sup>). Such fast (10&#x2013;30&#xa0;min), low-volume (10&#x2013;50&#xa0;&#xb5;L), low-cost, and simple to operate devices for immune cell enumeration are exactly what is needed in a CAR T cell manufacturing setting to decrease QC costs. For effective CQA monitoring, detection of different cell types is required, ideally all within one microfluidic device.</p>
<p>The Pappas Group has developed microfluidic devices that capture target cells on surfaces functionalized with antibodies against cell surface proteins (<xref ref-type="bibr" rid="B42">Li et al., 2012</xref>). They utilize polydimethylsiloxane (PDMS) stamping or pneumatic valves to coat specific areas of microfluidic channels with biotinylated antibodies, forming discrete cell-capture regions on the surface (<xref ref-type="bibr" rid="B42">Li et al., 2012</xref>; <xref ref-type="bibr" rid="B51">Liu et al., 2014</xref>). This allows detection of T cells expressing different cell surface markers, cells expressing different levels of the same antigen (<xref ref-type="bibr" rid="B90">Zhang and Pappas, 2016</xref>) as well as CD4<sup>&#x2b;</sup>/CD8<sup>&#x2b;</sup> ratio determination (<xref ref-type="bibr" rid="B42">Li et al., 2012</xref>; <xref ref-type="bibr" rid="B44">Li et al., 2015</xref>) and counting of CD64<sup>&#x2b;</sup> and CD69<sup>&#x2b;</sup> cells in patient samples to determine their sepsis status (<xref ref-type="bibr" rid="B91">Zhang et al., 2018</xref>; <xref ref-type="bibr" rid="B92">Zhou et al., 2019</xref>; <xref ref-type="bibr" rid="B31">Griffin et al., 2025</xref>).</p>
<p>Cytokine secretion analysis was performed on antibody-coated surfaces, where antibodies were used for both cell immobilization and cytokine capture. The signal from bound cytokines at levels below 1&#xa0;ng mL<sup>&#x2212;1</sup> was detected via Surface Plasmon Resonance Imaging (SPRI) and fluorescence microscopy (<xref ref-type="bibr" rid="B5">Baganizi et al., 2015</xref>). A combination of surface capture and fluorescent labelling can also be used to address the challenge of phenotyping specific cell types based on the expression of more than one marker. CD8<sup>&#x2b;</sup> T cells were captured on an antibody-functionalized PDMS-on-glass chip, followed by the flow of CD57 antibody on the captured cells to detect the proportion of CD8<sup>&#x2b;</sup> T cells that also express CD57 (<xref ref-type="bibr" rid="B14">Choi et al., 2024</xref>). A 10&#xa0;&#xb5;L heterogeneous sample of whole blood was tested, and the results were compared to flow cytometry, with good correlation, highlighting the efficiency and accuracy of this microfluidic system.</p>
<p>Surface capture of target cells coupled with optical detection and subsequent quantification is a promising approach for cell phenotyping. This could have a transformative impact on the quality control in CAR T cell manufacturing, where T cell markers such as CD3, CD19 or CAR define the product&#x2019;s purity and potency. The key to implementing microfluidic phenotyping systems in a manufacturing setting lies in workflow automation and the capability to detect multiple cell markers within one device or several devices operated simultaneously.</p>
</sec>
<sec id="s4">
<title>4 Cell phenotyping and cytokine detection using electrical signal</title>
<p>A Coulter Counter is an analytical technique used for counting blood cells by detecting changes in impedance of cell suspension flowing through an electric field (<xref ref-type="bibr" rid="B32">Grimnes and Martinsen, 2008</xref>). <xref ref-type="bibr" rid="B87">Watkins et al. (2013)</xref> captured CD4<sup>&#x2b;</sup> and CD8<sup>&#x2b;</sup> leukocytes from a whole blood sample and quantified them through the difference in impedance measurements pre- and post-capture chamber. The results were in agreement with flow cytometry, within a wide cell concentration range (0.04&#x2212;1.3 &#xd7; 10<sup>6</sup> cells mL<sup>&#x2212;1</sup>). Recently, <xref ref-type="bibr" rid="B67">Phi et al. (2025)</xref> utilized impedance measurements and microfluidic channels to develop a handheld device for CD4<sup>&#x2b;</sup> T cell enumeration of samples within the 0.075&#x2212;1.2 &#xd7; 10<sup>6</sup> cells mL<sup>&#x2212;1</sup> range. Such devices show the potential of microfluidic systems for accurate and automated cell phenotyping.</p>
<p>Impedance measurements have been utilized alongside other microfluidic manipulations. The Sarioglu group combined surface modification for selective cell capture alongside electrical detection of uncaptured cells to determine proportions of different leukocytes in a sample (<xref ref-type="bibr" rid="B53">Liu et al., 2019</xref>; <xref ref-type="bibr" rid="B54">Liu et al., 2020</xref>; <xref ref-type="bibr" rid="B16">Civelekoglu et al., 2022a</xref>). Fluorescent tagging has been used to perform absolute counts of CD4<sup>&#x2b;</sup> T cells from a lymphocyte sample (<xref ref-type="bibr" rid="B86">Wang et al., 2008</xref>). Magnetic labelling has been utilized to detect cells expressing different amounts of CD33 protein on their surface (<xref ref-type="bibr" rid="B17">Civelekoglu et al., 2022b</xref>). Leukocytes were magnetically separated on-chip and enumerated with an integrated Coulter Counter. The device was further developed to introduce a feedback loop for operational automation (<xref ref-type="bibr" rid="B18">Civelekoglu et al., 2022c</xref>), highlighting the robustness of the system. Nonetheless, this approach might not be suitable for testing more homogeneous samples such as pure T cells. Additionally, to truly improve the operational efficiency of CAR T cell analytical testing, the labelling of samples must be done on-chip, which was not the case in this system.</p>
<p>A label-free Coulter counter for immune cells was further developed by <xref ref-type="bibr" rid="B2">Arifuzzman et al. (2023)</xref> and <xref ref-type="bibr" rid="B3">Arifuzzman et al. (2025)</xref>, who utilized surface modification for cell capture to enumerate CD4<sup>&#x2b;</sup>, CD8<sup>&#x2b;</sup> and apoptotic T cells. The assay operated with a low error of 7% and delivered results in close correlation to flow cytometry. Combining a Coulter counter, a label-free cell determination, and a feedback loop control system resulted in a microfluidic device that has a clear potential in a manufacturing setting, as it delivers a process-relevant result in an automated manner.</p>
<p>Gold electrodes were functionalized with cytokine-specific aptamers (IFN&#x3b3;, TNF&#x3b1;) for the detection of the said cytokines by tracking changes in redox peak upon aptamer-target binding (<xref ref-type="bibr" rid="B50">Liu et al., 2011</xref>; <xref ref-type="bibr" rid="B52">Liu et al., 2015</xref>). A limit of detection (LoD) of 5.45&#xa0;ng mL<sup>&#x2212;1</sup> was achieved, and due to the use of aptamers instead of antibodies, the system did not require washing steps. Electrodes were employed to actuate microfluidic droplets to assess the dose response of Jurkat cells to a toxic component. The device showed a 20-fold increase in assay sensitivity, with no negative impact of electrical manipulation on cell viability (<xref ref-type="bibr" rid="B6">Barbulovic-Nad et al., 2008</xref>).</p>
<p>Despite offering accurate and often label-free cell analysis, these devices required the integration of electrodes, making the fabrication more complex and expensive. As CAR T cell therapy manufacturing is already expensive, new QC testing methods are only viable if they reduce costs. It is therefore encouraging that simpler and more cost-effective solutions are being developed by utilizing cheaper fabrication methods and detection systems (<xref ref-type="bibr" rid="B67">Phi et al., 2025</xref>; <xref ref-type="bibr" rid="B65">Panwar and Roy, 2019</xref>).</p>
</sec>
<sec id="s5">
<title>5 Cellular analysis via microfluidic detection of physical properties</title>
<p>Label-free analytical techniques simplify the assay by removing the need for sample manipulation. Microfluidic technology has been used to distinguish between cell types based on their physical characteristics. Using stiffness, for example, a microfluidic pillar array with progressively decreasing distances between pillars forced cells to deform increasingly as they travel through (<xref ref-type="bibr" rid="B37">Kang et al., 2018</xref>). The device enabled discrimination between T cells and monocytes as well as CD4<sup>&#x2b;</sup> and CD8<sup>&#x2b;</sup> T cells. Although the capability to separate monocytes as well as CD4<sup>&#x2b;</sup> and CD8<sup>&#x2b;</sup> lymphocytes is impressive, there was no on-chip detection of sorted cells, which (currently) limits the analytical power of this approach.</p>
<p>Counting of CD4<sup>&#x2b;</sup> and CD8<sup>&#x2b;</sup> cells was carried out by passing a fluorescently stained whole blood sample through microcavities, where leukocytes were trapped based on their size, and other cell types were washed away (<xref ref-type="bibr" rid="B35">Hosokawa et al., 2012</xref>). Similarly, decreasing pore sizes inside a microfluidic device were used to trap CD45<sup>&#x2b;</sup> cells for image-based enumeration, which showed good agreement with flow cytometry results (<xref ref-type="bibr" rid="B64">Noor et al., 2018</xref>; <xref ref-type="bibr" rid="B62">Mohd Noor et al., 2020</xref>).</p>
<p>Alternatively, light scattering was used to collect physical information about cells, such as cell dimensions, refractive index of the nucleus and the cytosol, and the nucleus to cytosol ratio (<xref ref-type="bibr" rid="B71">Rossi et al., 2019</xref>). To enhance the differences and therefore improve detection capabilities, a stimulus was added to the sample before the information was fed into a machine learning model to distinguish between CD4<sup>&#x2b;</sup> and CD8<sup>&#x2b;</sup> cells. It is an example of how microfluidic sample processing can be integrated with artificial intelligence (AI) to deliver new methods of cell phenotyping. Despite some success in microfluidic cell type determination of relevant cell types (CD4<sup>&#x2b;</sup>, CD8<sup>&#x2b;</sup>, CD45<sup>&#x2b;</sup>) using physical parameters, it is unclear whether enough physical differences can be detected between highly similar cells, e.g., CD3<sup>&#x2b;</sup>CAR<sup>&#x2b;</sup> and CD3<sup>&#x2b;</sup>CAR<sup>&#x2212;</sup> cells. The detection of physical parameters might therefore not be the most suitable microfluidic technology for integration into CAR T cell testing devices.</p>
</sec>
<sec id="s6">
<title>6 Use of microwells for cells and reagent co-localization</title>
<p>The use of microwells in microfluidic devices is widespread, enabling cell or reagent entrapment in a defined position for manipulation or analysis. A device with a collapsible roof containing microchambers was used to trap stimulated CD4<sup>&#x2b;</sup> T cells with beads functionalized with cytokine-specific and detection antibodies, all within one chamber (<xref ref-type="bibr" rid="B76">Son et al., 2016</xref>). The intensity of the fluorescence signal as the bead binds the IFN-&#x3b3; cytokine was quantified, generating a single cell secretion profile. <xref ref-type="bibr" rid="B89">Xue et al. (2017)</xref> developed a single-cell barcode chip (SCBC) where stimulated CAR T cells were trapped inside wells exposed to a 16-plex antibody array for a range of cytokines involved in effector, stimulatory, regulatory, and inflammatory functions. Fluorescence signal was generated using detection antibodies and data analyzed using Isoplexis software.</p>
<p>
<xref ref-type="bibr" rid="B93">Zhou et al. (2020)</xref> used microwells to assess T cell cytotoxicity against a prostate cancer cell line, while concurrently monitoring IFN-&#x3b3; release through trapping of antibody-functionalized beads with the cell pair complex. Similarly, microwells were used to co-localize T cells with target leukemia cells for microscopy monitoring to investigate not only cytotoxicity but also the impact of contact time and distance on the killing potential, and the cell-to-effector ratios (<xref ref-type="bibr" rid="B82">Tu et al., 2020</xref>).</p>
<p>Whilst hematological cancers are present in solution (i.e., blood), solid tumors form complex 3D tumor microenvironments (TME), hampering the effectiveness of CAR T cells <italic>in vivo</italic>. <xref ref-type="bibr" rid="B66">Park et al. (2019)</xref> utilized a microwell-based microfluidic device to carry out a CD8<sup>&#x2b;</sup> T cell cytotoxicity assay on cells embedded in extracellular matrix (ECM). When compared to a standard 2D culture-based assay, the cytotoxicity was lower in the former, which could indicate that the 3D model is more representative of the TME. <xref ref-type="bibr" rid="B58">Ma et al. (2023)</xref> measured the CAR T cell release of six cytokines in media using plasmonic scattering signal from immobilized gold nanoparticles (AuNPs). The assay was carried out in a Leukemia-on-a-Chip microfluidic model, providing further complexity to the analysis. To successfully translate CAR T cell therapies against solid tumors to the clinic, analytical assays that are representative of target TME are needed. This is where microfluidic technology could prove crucial. Additionally, assays that deliver results for more than one CQA (e.g., cytotoxicity and cytokine release), or provide additional information not currently investigated as part of the standard routine, could become part of testing protocols in the future. However, despite delivering sensitive results in T cell potency testing, microfluidic microwell devices often lack integrated automated sample processing and online detection (<xref ref-type="table" rid="T2">Table 2</xref>). This limits their potential for implementation in a manufacturing setting, as operator intervention is still required. Integration of automated liquid handlers (<xref ref-type="bibr" rid="B81">Tran et al., 2022</xref>) or bespoke robotic systems (<xref ref-type="bibr" rid="B43">Li et al., 2014</xref>) could improve the prospects of microwell device implementation in a production environment.</p>
</sec>
<sec id="s7">
<title>7 Other</title>
<p>Alternative approaches have been taken to deliver results relevant to CAR T cell therapy manufacturing. One example is the cost-effective and straightforward CD4<sup>&#x2b;</sup> T cell counting, utilizing fluorescent antibody labelling alongside image cytometry (<xref ref-type="bibr" rid="B69">Rodriguez et al., 2005</xref>; <xref ref-type="bibr" rid="B4">Bae et al., 2009</xref>). Similarly, cell enumeration was obtained inside a microfluidic device by flowing magnetically pre-labelled cells into detection (target) and waste (non-target) zones (<xref ref-type="bibr" rid="B77">Song et al., 2019</xref>). Target cells were subsequently detected using a resistive pulse sensor. An alternating current electrohydrodynamic (ac-EHD) microfluidic device was used for the isolation of CD4<sup>&#x2b;</sup> T cells, where 100 target cells were detected within a heterogeneous sample of 106 cells. In addition, T cell receptor profiling was carried out using SERS (<xref ref-type="bibr" rid="B22">Dey et al., 2019</xref>). Despite the labelling of the sample with SERS tags, the SERS analysis was performed off-chip, thus without integration of sample processing with online detection.</p>
<p>While delivering accurate cell enumeration methods, these systems require sample pre-processing. This limits their applicability in manufacturing as any manual processing adds operational complexity.</p>
<p>A more suitable approach was developed by <xref ref-type="bibr" rid="B68">Qiu et al. (2018)</xref> where a single magnetic bead functionalized against CD4 was used for microfluidic CD4<sup>&#x2b;</sup> T cell quantification. Each step of a chemiluminescence sandwich immunoassay was integrated into the device, with magnetic control used not only to actuate the bead from one step to another but also to improve reagent mixing. As limited sample processing is required, this device is an excellent candidate for implementation in QC testing, provided that additional T cell markers can be quantified in this manner.</p>
<p>Flow cytometry is based on the flow focusing of cells into a single stream for the detection of surface proteins. This process can be miniaturized utilizing microfluidic technology and has been reviewed elsewhere (<xref ref-type="bibr" rid="B30">Gong et al., 2019</xref>). Despite advantages over flow cytometry in terms of reagent use and portability, microfluidic versions continue to rely on lasers and other high-cost detection equipment, which may reduce their practicality for implementation in already costly cell therapy manufacturing.</p>
</sec>
<sec id="s8">
<title>8 Summary</title>
<p>A range of microfluidic techniques, combined with various detection modes, has proven successful in establishing T cell analytical assays relevant to CAR T cell manufacturing. Some of the devices discussed here offer quantitative results with on-chip detection, coupled with automation and integrated sample preparation, making them attractive candidates for implementation in QC testing. In addition to comparable assay performance with the gold standard, further considerations will need to be addressed for microfluidics to have a significant impact on QC in CAR T cell manufacturing. These include, for example, specific requirements of the assay type, such as the stringent sterility demands in cytotoxicity testing, as well as microfluidics considerations, including the robustness of operation. Ultimately, the cost of device manufacture is also a factor, yet is outside the scope of this review. Furthermore, some devices demonstrate the capability to measure, for example, a specific cell marker, while others provide analytical readouts of multiple CQAs, such as cytotoxicity and cytokine secretion profiles. This raises the possibility of developing a device that incorporates all essential QC tests. However, integrating all tests into one device would pose a significant demand on the complexity of operation. It remains to be seen whether such systems can be straightforward to use and meet the demands of reproducibility required in the GMP environment. Comparing emerging technologies, such as microfluidic approaches, systematically with established methods used in industry would further support the development of such novel approaches; however for such a comparison, more data is needed about the existing assays. Improved transparency for example through peer-reviewed assessment of sensitivity, accuracy and cost-effectiveness of existing assays could provide such data. Additionally, direct interfacing with the cell processing systems for at-line or online CQA detection is the goal of developing Process Analytical Technologies (PATs). While microfluidic technology is available to deliver relevant analytical results, none of the devices discussed in this review have been reported to connect to processing equipment. The integration of automated microfluidic devices with the bioreactor systems will be crucial to truly realize the vision of PAT and drive the technological innovation in CAR T cell manufacturing.</p>
</sec>
</body>
<back>
<sec sec-type="author-contributions" id="s9">
<title>Author contributions</title>
<p>AN: Conceptualization, Investigation, Writing &#x2013; original draft. KL: Supervision, Writing &#x2013; review and editing. MT: Supervision, Writing &#x2013; review and editing. NS: Supervision, Writing &#x2013; review and editing.</p>
</sec>
<sec sec-type="funding-information" id="s10">
<title>Funding</title>
<p>The author(s) declare that financial support was received for the research and/or publication of this article. This work was supported by an Industrial Fellowship from the Royal Commission for the Exhibition 1851. UCL Biochemical Engineering hosts the Future Targeted Healthcare Manufacturing Hub in collaboration with UK universities and with funding from the UK Engineering &#x0026; Physical Sciences Research Council (EPSRC, EP/P006485/1) and a consortium of industrial users and sector organisations.</p>
</sec>
<sec sec-type="COI-statement" id="s11">
<title>Conflict of interest</title>
<p>Authors AN and KL were employed by Autolus Ltd. NS is the Director of Young Owl Microfluidics Ltd.</p>
<p>The remaining author declares that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec sec-type="ai-statement" id="s12">
<title>Generative AI statement</title>
<p>The author(s) declare that no Generative AI was used in the creation of this manuscript.</p>
<p>Any alternative text (alt text) provided alongside figures in this article has been generated by Frontiers with the support of artificial intelligence and reasonable efforts have been made to ensure accuracy, including review by the authors wherever possible. If you identify any issues, please contact us.</p>
</sec>
<sec sec-type="disclaimer" id="s13">
<title>Publisher&#x2019;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<fn-group>
<fn id="fn1">
<label>1</label>
<p>See glossary for full list of abbreviations.</p>
</fn>
</fn-group>
<ref-list>
<title>References</title>
<ref id="B1">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Aranda Hernandez</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Heuer</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Bahnemann</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Szita</surname>
<given-names>N.</given-names>
</name>
</person-group> (<year>2021</year>). &#x201c;<article-title>Microfluidic devices as process development tools for cellular therapy manufacturing</article-title>,&#x201d; in <source>Microfluidics in biotechnology</source> (<publisher-name>Springer International Publishing</publisher-name>).</citation>
</ref>
<ref id="B2">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Arifuzzman</surname>
<given-names>A. K. M.</given-names>
</name>
<name>
<surname>Asmare</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Ozkaya-Ahmadov</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Civelekoglu</surname>
<given-names>O.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Sarioglu</surname>
<given-names>A. F.</given-names>
</name>
</person-group> (<year>2023</year>). <article-title>An autonomous microchip for real-time, label-free immune cell analysis</article-title>. <source>Biosens. Bioelectron.</source> <volume>222</volume>, <fpage>114916</fpage>. <pub-id pub-id-type="doi">10.1016/j.bios.2022.114916</pub-id>
<pub-id pub-id-type="pmid">36462431</pub-id>
</citation>
</ref>
<ref id="B3">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Arifuzzman</surname>
<given-names>A. K. M.</given-names>
</name>
<name>
<surname>Asmare</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Ozkaya</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Valipour</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Sarioglu</surname>
<given-names>A. F.</given-names>
</name>
</person-group> (<year>2025</year>). <article-title>Electronic detection of apoptotic cells on a microchip</article-title>. <source>Biosens. Bioelectron.</source> <volume>267</volume>, <fpage>116750</fpage>. <pub-id pub-id-type="doi">10.1016/j.bios.2024.116750</pub-id>
<pub-id pub-id-type="pmid">39307034</pub-id>
</citation>
</ref>
<ref id="B4">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bae</surname>
<given-names>S. Y.</given-names>
</name>
<name>
<surname>Park</surname>
<given-names>H. C.</given-names>
</name>
<name>
<surname>Oh</surname>
<given-names>J. S.</given-names>
</name>
<name>
<surname>Yoon</surname>
<given-names>S. Y.</given-names>
</name>
<name>
<surname>Park</surname>
<given-names>D. W.</given-names>
</name>
<name>
<surname>Choi</surname>
<given-names>I. K.</given-names>
</name>
<etal/>
</person-group> (<year>2009</year>). <article-title>Absolute CD4&#x2b; cell count using a plastic microchip and a microscopic cell counter</article-title>. <source>Cytom. Part B - Clin. Cytom.</source> <volume>76</volume>, <fpage>345</fpage>&#x2013;<lpage>353</lpage>. <pub-id pub-id-type="doi">10.1002/cyto.b.20470</pub-id>
<pub-id pub-id-type="pmid">19130482</pub-id>
</citation>
</ref>
<ref id="B5">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Baganizi</surname>
<given-names>D. R.</given-names>
</name>
<name>
<surname>Leroy</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Laplatine</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Fairley</surname>
<given-names>S. J.</given-names>
</name>
<name>
<surname>Heidmann</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Menad</surname>
<given-names>S.</given-names>
</name>
<etal/>
</person-group> (<year>2015</year>). <article-title>A simple microfluidic platform for long-term analysis and continuous dual-imaging detection of T-Cell secreted IFN-&#x3b3; and IL-2 on antibody-based biochip</article-title>. <source>Biosensors-Basel</source> <volume>5</volume>, <fpage>750</fpage>&#x2013;<lpage>767</lpage>. <pub-id pub-id-type="doi">10.3390/bios5040750</pub-id>
<pub-id pub-id-type="pmid">26690235</pub-id>
</citation>
</ref>
<ref id="B6">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Barbulovic-Nad</surname>
<given-names>I.</given-names>
</name>
<name>
<surname>Yang</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Park</surname>
<given-names>P. S.</given-names>
</name>
<name>
<surname>Wheeler</surname>
<given-names>A. R.</given-names>
</name>
</person-group> (<year>2008</year>). <article-title>Digital microfluidics for cell-based assays</article-title>. <source>Lab a Chip</source> <volume>8</volume>, <fpage>519</fpage>&#x2013;<lpage>526</lpage>. <pub-id pub-id-type="doi">10.1039/b717759c</pub-id>
<pub-id pub-id-type="pmid">18369505</pub-id>
</citation>
</ref>
<ref id="B7">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Barry</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Velickovic</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Rasko</surname>
<given-names>J.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Endotoxin quality control testing for CAR T-cell manufacturing: validation considerations for endosafe portable testing system</article-title>. <source>Cytotherapy</source> <volume>22</volume>, <fpage>S140</fpage>. <pub-id pub-id-type="doi">10.1016/j.jcyt.2020.03.279</pub-id>
</citation>
</ref>
<ref id="B8">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bounab</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Eyer</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Dixneuf</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Rybczynska</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Chauvel</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Mistretta</surname>
<given-names>M.</given-names>
</name>
<etal/>
</person-group> (<year>2020</year>). <article-title>Dynamic single-cell phenotyping of immune cells using the microfluidic platform DropMap</article-title>. <source>Nat. Protoc.</source> <volume>15</volume>, <fpage>2920</fpage>&#x2013;<lpage>2955</lpage>. <pub-id pub-id-type="doi">10.1038/s41596-020-0354-0</pub-id>
<pub-id pub-id-type="pmid">32788719</pub-id>
</citation>
</ref>
<ref id="B9">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Cao</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Carlson</surname>
<given-names>R. D.</given-names>
</name>
<name>
<surname>Staudt</surname>
<given-names>R. E.</given-names>
</name>
<name>
<surname>Snook</surname>
<given-names>A. E.</given-names>
</name>
</person-group> (<year>2024</year>). <article-title>
<italic>In vitro</italic> assays to evaluate CAR-T cell cytotoxicity</article-title>. <source>Methods Cell Biol.</source> <volume>183</volume>, <fpage>303</fpage>&#x2013;<lpage>315</lpage>. <pub-id pub-id-type="doi">10.1016/bs.mcb.2023.05.009</pub-id>
<pub-id pub-id-type="pmid">38548415</pub-id>
</citation>
</ref>
<ref id="B10">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Cardenas-Benitez</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Hurtado</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Luo</surname>
<given-names>X. H.</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>A. P.</given-names>
</name>
</person-group> (<year>2024</year>). <article-title>Three-dimensional isotropic imaging of live suspension cells enabled by droplet microvortices</article-title>. <source>Proc. Natl. Acad. Sci. U. S. A.</source> <volume>121</volume>, <fpage>e2408567121</fpage>. <pub-id pub-id-type="doi">10.1073/pnas.2408567121</pub-id>
<pub-id pub-id-type="pmid">39436653</pub-id>
</citation>
</ref>
<ref id="B11">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Castella</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Caballero-Banos</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Ortiz-Maldonado</surname>
<given-names>V.</given-names>
</name>
<name>
<surname>Gonzalez-Navarro</surname>
<given-names>E. A.</given-names>
</name>
<name>
<surname>Sune</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Antonana-Vidosola</surname>
<given-names>A.</given-names>
</name>
<etal/>
</person-group> (<year>2020</year>). <article-title>Point-of-care CAR T-Cell production (ARI-0001) using a closed semi-automatic bioreactor: experience from an academic phase I clinical trial</article-title>. <source>Front. Immunol.</source> <volume>11</volume>, <fpage>482</fpage>. <pub-id pub-id-type="doi">10.3389/fimmu.2020.00482</pub-id>
<pub-id pub-id-type="pmid">32528460</pub-id>
</citation>
</ref>
<ref id="B12">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Cheng</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Irimia</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Dixon</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Sekine</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Demirci</surname>
<given-names>U.</given-names>
</name>
<name>
<surname>Zamir</surname>
<given-names>L.</given-names>
</name>
<etal/>
</person-group> (<year>2007</year>). <article-title>A microfluidic device for practical label-free CD4&#x2b; T cell counting of HIV-infected subjects</article-title>. <source>Lab. Chip</source> <volume>7</volume>, <fpage>170</fpage>&#x2013;<lpage>178</lpage>. <pub-id pub-id-type="doi">10.1039/b612966h</pub-id>
<pub-id pub-id-type="pmid">17268618</pub-id>
</citation>
</ref>
<ref id="B13">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Cheng</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Gupta</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Tompkins</surname>
<given-names>R. G.</given-names>
</name>
<name>
<surname>Rodriguez</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Toner</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2009</year>). <article-title>Enhancing the performance of a point-of-care CD4&#x2b; T-cell counting microchip through monocyte depletion for HIV/AIDS diagnostics</article-title>. <source>Lab a Chip</source> <volume>9</volume>, <fpage>1357</fpage>&#x2013;<lpage>1364</lpage>. <pub-id pub-id-type="doi">10.1039/b818813k</pub-id>
<pub-id pub-id-type="pmid">19417901</pub-id>
</citation>
</ref>
<ref id="B14">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Choi</surname>
<given-names>Y.-H.</given-names>
</name>
<name>
<surname>Kim</surname>
<given-names>W.-J.</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Jung</surname>
<given-names>B.-J.</given-names>
</name>
<name>
<surname>Shin</surname>
<given-names>E.-C.</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>W.</given-names>
</name>
</person-group> (<year>2024</year>). <article-title>Microfluidic capture device for simple, cell surface marker-based quantification of senescent CD8&#x2b; T cells</article-title>. <source>BioChip J.</source> <volume>18</volume>, <fpage>382</fpage>&#x2013;<lpage>392</lpage>. <pub-id pub-id-type="doi">10.1007/s13206-024-00142-6</pub-id>
</citation>
</ref>
<ref id="B15">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Civelekoglu</surname>
<given-names>O.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Boya</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Ozkaya-Ahmadov</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Liu</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Sarioglu</surname>
<given-names>A. F.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Electronic profiling of membrane antigen expression via immunomagnetic cell manipulation</article-title>. <source>Lab a Chip</source> <volume>19</volume>, <fpage>2444</fpage>&#x2013;<lpage>2455</lpage>. <pub-id pub-id-type="doi">10.1039/c9lc00297a</pub-id>
<pub-id pub-id-type="pmid">31199420</pub-id>
</citation>
</ref>
<ref id="B16">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Civelekoglu</surname>
<given-names>O.</given-names>
</name>
<name>
<surname>Liu</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Usanmaz</surname>
<given-names>C. F.</given-names>
</name>
<name>
<surname>Chu</surname>
<given-names>C.-H.</given-names>
</name>
<name>
<surname>Boya</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Ozkaya-Ahmadov</surname>
<given-names>T.</given-names>
</name>
<etal/>
</person-group> (<year>2022a</year>). <article-title>Electronic measurement of cell antigen expression in whole blood</article-title>. <source>Lab a Chip</source> <volume>22</volume>, <fpage>296</fpage>&#x2013;<lpage>312</lpage>. <pub-id pub-id-type="doi">10.1039/d1lc00889g</pub-id>
<pub-id pub-id-type="pmid">34897353</pub-id>
</citation>
</ref>
<ref id="B17">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Civelekoglu</surname>
<given-names>O.</given-names>
</name>
<name>
<surname>Ozkaya-Ahmadov</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Arifuzzman</surname>
<given-names>A. K. M.</given-names>
</name>
<name>
<surname>Islak Mutcali</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Sarioglu</surname>
<given-names>A. F.</given-names>
</name>
</person-group> (<year>2022b</year>). <article-title>Immunomagnetic leukocyte differential in whole blood on an electronic microdevice</article-title>. <source>Lab a Chip</source> <volume>22</volume>, <fpage>2331</fpage>&#x2013;<lpage>2342</lpage>. <pub-id pub-id-type="doi">10.1039/d2lc00137c</pub-id>
<pub-id pub-id-type="pmid">35593257</pub-id>
</citation>
</ref>
<ref id="B18">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Civelekoglu</surname>
<given-names>O.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Arifuzzman</surname>
<given-names>A. K. M.</given-names>
</name>
<name>
<surname>Boya</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Sarioglu</surname>
<given-names>A. F.</given-names>
</name>
</person-group> (<year>2022c</year>). <article-title>Automated lightless cytometry on a microchip with adaptive immunomagnetic manipulation</article-title>. <source>Biosens. Bioelectron.</source> <volume>203</volume>, <fpage>114014</fpage>. <pub-id pub-id-type="doi">10.1016/j.bios.2022.114014</pub-id>
<pub-id pub-id-type="pmid">35092880</pub-id>
</citation>
</ref>
<ref id="B19">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Cong</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Tian</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Xu</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Liang</surname>
<given-names>C.</given-names>
</name>
<etal/>
</person-group> (<year>2022</year>). <article-title>Microfluidic Droplet-SERS platform for single-cell cytokine analysis via a cell surface bioconjugation strategy</article-title>. <source>Anal. Chem.</source> <volume>94</volume>, <fpage>10375</fpage>&#x2013;<lpage>10383</lpage>. <pub-id pub-id-type="doi">10.1021/acs.analchem.2c01249</pub-id>
<pub-id pub-id-type="pmid">35815899</pub-id>
</citation>
</ref>
<ref id="B20">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Dagar</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Gupta</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Masoodi</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Nisar</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Merhi</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Hashem</surname>
<given-names>S.</given-names>
</name>
<etal/>
</person-group> (<year>2023</year>). <article-title>Harnessing the potential of CAR-T cell therapy: progress, challenges, and future directions in hematological and solid tumor treatments</article-title>. <source>J. Transl. Med.</source> <volume>21</volume>, <fpage>449</fpage>. <pub-id pub-id-type="doi">10.1186/s12967-023-04292-3</pub-id>
<pub-id pub-id-type="pmid">37420216</pub-id>
</citation>
</ref>
<ref id="B21">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Delgado</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Roddie</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Schmitt</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2022</year>). &#x201c;<article-title>Point-of-Care production of CAR-T cells</article-title>,&#x201d; in <source>The EBMT/EHA CAR-T cell handbook</source> (<publisher-name>Springer International Publishing</publisher-name>).</citation>
</ref>
<ref id="B22">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Dey</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Vaidyanathan</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Reza</surname>
<given-names>K. K.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Nel</surname>
<given-names>H. J.</given-names>
</name>
<etal/>
</person-group> (<year>2019</year>). <article-title>A microfluidic-SERSplatform for isolation and immuno-phenotyping of antigen specific T-cells</article-title>. <source>Sensors Actuators B Chem.</source> <volume>284</volume>, <fpage>281</fpage>&#x2013;<lpage>288</lpage>. <pub-id pub-id-type="doi">10.1016/j.snb.2018.12.099</pub-id>
</citation>
</ref>
<ref id="B23">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Dias</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Garcia</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Agliardi</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Roddie</surname>
<given-names>C.</given-names>
</name>
</person-group> (<year>2024</year>). <article-title>CAR-T cell manufacturing landscape&#x2014;Lessons from the past decade and considerations for early clinical development</article-title>. <source>Mol. Ther. - Methods Clin. Dev.</source> <volume>32</volume>, <fpage>101250</fpage>. <pub-id pub-id-type="doi">10.1016/j.omtm.2024.101250</pub-id>
<pub-id pub-id-type="pmid">38737799</pub-id>
</citation>
</ref>
<ref id="B24">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Fan</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Qiao</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Jin</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Zhou</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Ge</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Jin</surname>
<given-names>Q.</given-names>
</name>
<etal/>
</person-group> (<year>2019</year>). <article-title>High efficiency single-cell capture based on microfluidics for single cell analysis</article-title>. <source>J. Micromechanics Microengineering</source> <volume>29</volume>, <fpage>035004</fpage>. <pub-id pub-id-type="doi">10.1088/1361-6439/aaf9df</pub-id>
</citation>
</ref>
<ref id="B25">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Fan</surname>
<given-names>Y. J.</given-names>
</name>
<name>
<surname>Hsiao</surname>
<given-names>Y. C.</given-names>
</name>
<name>
<surname>Weng</surname>
<given-names>Y. L.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>Y. H.</given-names>
</name>
<name>
<surname>Chiou</surname>
<given-names>P. Y.</given-names>
</name>
<name>
<surname>Sheen</surname>
<given-names>H. J.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Development of a parallel three-dimensional microfluidic device for high-throughput cytometry</article-title>. <source>Sensors Actuators B-Chemical</source> <volume>320</volume>, <fpage>128255</fpage>. <pub-id pub-id-type="doi">10.1016/j.snb.2020.128255</pub-id>
</citation>
</ref>
<ref id="B26">
<citation citation-type="book">
<collab>FDA</collab> (<year>2024</year>). <source>Considerations for the development of chimeric antigen receptor (CAR) T cell products</source>.</citation>
</ref>
<ref id="B27">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Frankowski</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Theisen</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Kummrow</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Simon</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Ragusch</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Bock</surname>
<given-names>N.</given-names>
</name>
<etal/>
</person-group> (<year>2013</year>). <article-title>Microflow cytometers with integrated hydrodynamic focusing</article-title>. <source>Sensors</source> <volume>13</volume>, <fpage>4674</fpage>&#x2013;<lpage>4693</lpage>. <pub-id pub-id-type="doi">10.3390/s130404674</pub-id>
<pub-id pub-id-type="pmid">23571670</pub-id>
</citation>
</ref>
<ref id="B28">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Gebo</surname>
<given-names>J. E. T.</given-names>
</name>
<name>
<surname>Lau</surname>
<given-names>A. F.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Sterility testing for cellular therapies: what is the role of the clinical microbiology laboratory?</article-title> <source>J. Clin. Microbiol.</source> <volume>58</volume>, <fpage>e01492-19</fpage>. <pub-id pub-id-type="doi">10.1128/jcm.01492-19</pub-id>
<pub-id pub-id-type="pmid">32321785</pub-id>
</citation>
</ref>
<ref id="B29">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Gee</surname>
<given-names>A. P.</given-names>
</name>
</person-group> (<year>2015</year>). <article-title>Manufacturing genetically modified T cells for clinical trials</article-title>. <source>Cancer Gene Ther.</source> <volume>22</volume>, <fpage>67</fpage>&#x2013;<lpage>71</lpage>. <pub-id pub-id-type="doi">10.1038/cgt.2014.71</pub-id>
<pub-id pub-id-type="pmid">25633481</pub-id>
</citation>
</ref>
<ref id="B30">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Gong</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Fan</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Yang</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Peng</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Jiang</surname>
<given-names>H.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>New advances in microfluidic flow cytometry</article-title>. <source>Electrophoresis</source> <volume>40</volume>, <fpage>1212</fpage>&#x2013;<lpage>1229</lpage>. <pub-id pub-id-type="doi">10.1002/elps.201800298</pub-id>
<pub-id pub-id-type="pmid">30242856</pub-id>
</citation>
</ref>
<ref id="B31">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Griffin</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Miller</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Yang</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Sharp</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Young</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Garcia</surname>
<given-names>L.</given-names>
</name>
<etal/>
</person-group> (<year>2025</year>). <article-title>Affinity-based 3D-printed microfluidic chip for clinical sepsis detection with CD69, CD64, and CD25</article-title>. <source>J. Pharm. Biomed. Analysis</source> <volume>252</volume>, <fpage>116500</fpage>. <pub-id pub-id-type="doi">10.1016/j.jpba.2024.116500</pub-id>
<pub-id pub-id-type="pmid">39383543</pub-id>
</citation>
</ref>
<ref id="B32">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Grimnes</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Martinsen</surname>
<given-names>O. G.</given-names>
</name>
</person-group> (<year>2008</year>). <source>Bioimpedance and bioelectricity basics</source>. <edition>2nd Edition</edition>, <fpage>1</fpage>&#x2013;<lpage>471</lpage>.</citation>
</ref>
<ref id="B33">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Harrison</surname>
<given-names>R. P.</given-names>
</name>
<name>
<surname>Zylberberg</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Ellison</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Levine</surname>
<given-names>B. L.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Chimeric antigen receptor-T cell therapy manufacturing: modelling the effect of offshore production on aggregate cost of goods</article-title>. <source>Cytotherapy</source> <volume>21</volume>, <fpage>224</fpage>&#x2013;<lpage>233</lpage>. <pub-id pub-id-type="doi">10.1016/j.jcyt.2019.01.003</pub-id>
<pub-id pub-id-type="pmid">30770285</pub-id>
</citation>
</ref>
<ref id="B34">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hollyman</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Stefanski</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Przybylowski</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Bartido</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Borquez-Ojeda</surname>
<given-names>O.</given-names>
</name>
<name>
<surname>Taylor</surname>
<given-names>C.</given-names>
</name>
<etal/>
</person-group> (<year>2009</year>). <article-title>Manufacturing validation of biologically functional T cells targeted to CD19 antigen for autologous adoptive cell therapy</article-title>. <source>J. Immunother.</source> <volume>32</volume>, <fpage>169</fpage>&#x2013;<lpage>180</lpage>. <pub-id pub-id-type="doi">10.1097/cji.0b013e318194a6e8</pub-id>
<pub-id pub-id-type="pmid">19238016</pub-id>
</citation>
</ref>
<ref id="B35">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hosokawa</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Asami</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Nakamura</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Yoshino</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Tsujimura</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Takahashi</surname>
<given-names>M.</given-names>
</name>
<etal/>
</person-group> (<year>2012</year>). <article-title>Leukocyte counting from a small amount of whole blood using a size-controlled microcavity array</article-title>. <source>Biotechnol. Bioeng.</source> <volume>109</volume>, <fpage>2017</fpage>&#x2013;<lpage>2024</lpage>. <pub-id pub-id-type="doi">10.1002/bit.24471</pub-id>
<pub-id pub-id-type="pmid">22367741</pub-id>
</citation>
</ref>
<ref id="B36">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kanakasabapathy</surname>
<given-names>M. K.</given-names>
</name>
<name>
<surname>Pandya</surname>
<given-names>H. J.</given-names>
</name>
<name>
<surname>Draz</surname>
<given-names>M. S.</given-names>
</name>
<name>
<surname>Chug</surname>
<given-names>M. K.</given-names>
</name>
<name>
<surname>Sadasivam</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Kumar</surname>
<given-names>S.</given-names>
</name>
<etal/>
</person-group> (<year>2017</year>). <article-title>Rapid, label-free CD4 testing using a smartphone compatible device</article-title>. <source>Lab a Chip</source> <volume>17</volume>, <fpage>2910</fpage>&#x2013;<lpage>2919</lpage>. <pub-id pub-id-type="doi">10.1039/c7lc00273d</pub-id>
<pub-id pub-id-type="pmid">28702612</pub-id>
</citation>
</ref>
<ref id="B37">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kang</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Guo</surname>
<given-names>Q.</given-names>
</name>
<name>
<surname>Islamzada</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Ma</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Scott</surname>
<given-names>M. D.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Microfluidic determination of lymphocyte vascular deformability: effects of intracellular complexity and early immune activation</article-title>. <source>Integr. Biol. (United Kingdom)</source> <volume>10</volume>, <fpage>207</fpage>&#x2013;<lpage>217</lpage>. <pub-id pub-id-type="doi">10.1039/c7ib00191f</pub-id>
<pub-id pub-id-type="pmid">29570200</pub-id>
</citation>
</ref>
<ref id="B38">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Khang</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Suryaprakash</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Kotrappa</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Mulyasasmita</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Topp</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Wu</surname>
<given-names>J.</given-names>
</name>
</person-group> (<year>2023</year>). <article-title>Manufacturing innovation to drive down cell therapy costs</article-title>. <source>Trends Biotechnol.</source> <volume>41</volume>, <fpage>1216</fpage>&#x2013;<lpage>1219</lpage>. <pub-id pub-id-type="doi">10.1016/j.tibtech.2023.04.006</pub-id>
<pub-id pub-id-type="pmid">37236813</pub-id>
</citation>
</ref>
<ref id="B39">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kiesgen</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Messinger</surname>
<given-names>J. C.</given-names>
</name>
<name>
<surname>Chintala</surname>
<given-names>N. K.</given-names>
</name>
<name>
<surname>Tano</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Adusumilli</surname>
<given-names>P. S.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Comparative analysis of assays to measure CAR T-cell-mediated cytotoxicity</article-title>. <source>Nat. Protoc.</source> <volume>16</volume>, <fpage>1331</fpage>&#x2013;<lpage>1342</lpage>. <pub-id pub-id-type="doi">10.1038/s41596-020-00467-0</pub-id>
<pub-id pub-id-type="pmid">33589826</pub-id>
</citation>
</ref>
<ref id="B40">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kim</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Kim</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Lim</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Chung</surname>
<given-names>A. J.</given-names>
</name>
</person-group> (<year>2024</year>). <article-title>Expanding CAR-T cell immunotherapy Horizons through microfluidics</article-title>. <source>Lab a Chip</source> <volume>24</volume>, <fpage>1088</fpage>&#x2013;<lpage>1120</lpage>. <pub-id pub-id-type="doi">10.1039/d3lc00622k</pub-id>
<pub-id pub-id-type="pmid">38174732</pub-id>
</citation>
</ref>
<ref id="B41">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Konry</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Dominguez-Villar</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Baecher-Allan</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Hafler</surname>
<given-names>D. A.</given-names>
</name>
<name>
<surname>Yarmush</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2011</year>). <article-title>Droplet-based microfluidic platforms for single T cell secretion analysis of IL-10 cytokine</article-title>. <source>Biosens. Bioelectron.</source> <volume>26</volume>, <fpage>2707</fpage>&#x2013;<lpage>2710</lpage>. <pub-id pub-id-type="doi">10.1016/j.bios.2010.09.006</pub-id>
<pub-id pub-id-type="pmid">20888750</pub-id>
</citation>
</ref>
<ref id="B42">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Li</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Gao</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Pappas</surname>
<given-names>D.</given-names>
</name>
</person-group> (<year>2012</year>). <article-title>Multiparameter cell affinity chromatography: separation and analysis in a single microfluidic channel</article-title>. <source>Anal. Chem.</source> <volume>84</volume>, <fpage>8140</fpage>&#x2013;<lpage>8148</lpage>. <pub-id pub-id-type="doi">10.1021/ac302002a</pub-id>
<pub-id pub-id-type="pmid">22958145</pub-id>
</citation>
</ref>
<ref id="B43">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Li</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Guan</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Dong</surname>
<given-names>Q.</given-names>
</name>
<name>
<surname>Ruan</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Hu</surname>
<given-names>R.</given-names>
</name>
<etal/>
</person-group> (<year>2014</year>). <article-title>A smartphone controlled handheld microfluidic liquid handling system</article-title>. <source>Lab. Chip</source> <volume>14</volume>, <fpage>4085</fpage>&#x2013;<lpage>4092</lpage>. <pub-id pub-id-type="doi">10.1039/c4lc00227j</pub-id>
<pub-id pub-id-type="pmid">25182078</pub-id>
</citation>
</ref>
<ref id="B44">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Li</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Gao</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Pappas</surname>
<given-names>D.</given-names>
</name>
</person-group> (<year>2015</year>). <article-title>A complementary method to CD4 counting: measurement of CD4&#x2b;/CD8&#x2b; T lymphocyte ratio in a tandem affinity microfluidic system</article-title>. <source>Biomed. Microdevices</source> <volume>17</volume>, <fpage>113</fpage>&#x2013;<lpage>119</lpage>. <pub-id pub-id-type="doi">10.1007/s10544-015-0023-1</pub-id>
<pub-id pub-id-type="pmid">26559198</pub-id>
</citation>
</ref>
<ref id="B45">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Li</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Ma</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Cheng</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Tian</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Guo</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>Y.</given-names>
</name>
<etal/>
</person-group> (<year>2023</year>). <article-title>Droplets microfluidics platform&#x2014;A tool for single cell research</article-title>. <source>Front. Bioeng. Biotechnol.</source> <volume>11</volume>, <fpage>1121870</fpage>. <pub-id pub-id-type="doi">10.3389/fbioe.2023.1121870</pub-id>
<pub-id pub-id-type="pmid">37152651</pub-id>
</citation>
</ref>
<ref id="B46">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lian</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Lv</surname>
<given-names>X.</given-names>
</name>
</person-group> (<year>2025</year>). <article-title>Recent developments in SERS microfluidic chips: from fundamentals to biosensing applications</article-title>. <source>ACS Appl. Mater Interfaces</source> <volume>17</volume>, <fpage>10193</fpage>&#x2013;<lpage>10230</lpage>. <pub-id pub-id-type="doi">10.1021/acsami.4c17779</pub-id>
<pub-id pub-id-type="pmid">39907016</pub-id>
</citation>
</ref>
<ref id="B47">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Liang</surname>
<given-names>H. Y.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>D. Y.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>Y. Y.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>Y. X.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>J. B.</given-names>
</name>
<etal/>
</person-group> (<year>2022</year>). <article-title>Development of microfluidic flow cytometry capable of characterization of single-cell intrinsic structural and electrical parameters</article-title>. <source>J. Micromechanics Microengineering</source> <volume>32</volume>, <fpage>035007</fpage>. <pub-id pub-id-type="doi">10.1088/1361-6439/ac5171</pub-id>
</citation>
</ref>
<ref id="B48">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lin-Gibson</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Lin</surname>
<given-names>N. J.</given-names>
</name>
<name>
<surname>Jackson</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Viswanathan</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Zylberberg</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Wolfrum</surname>
<given-names>J.</given-names>
</name>
<etal/>
</person-group> (<year>2021</year>). <article-title>Standards efforts and landscape for rapid microbial testing methodologies in regenerative medicine</article-title>. <source>Cytotherapy</source> <volume>23</volume>, <fpage>390</fpage>&#x2013;<lpage>398</lpage>. <pub-id pub-id-type="doi">10.1016/j.jcyt.2020.07.006</pub-id>
<pub-id pub-id-type="pmid">33775524</pub-id>
</citation>
</ref>
<ref id="B49">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lisby</surname>
<given-names>A. N.</given-names>
</name>
<name>
<surname>Carlson</surname>
<given-names>R. D.</given-names>
</name>
<name>
<surname>Baybutt</surname>
<given-names>T. R.</given-names>
</name>
<name>
<surname>Weindorfer</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Snook</surname>
<given-names>A. E.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Evaluation of CAR-T cell cytotoxicity: real-time impedance-based analysis</article-title>. <source>Methods Cell Biol.</source> <volume>167</volume>, <fpage>81</fpage>&#x2013;<lpage>98</lpage>. <pub-id pub-id-type="doi">10.1016/bs.mcb.2021.08.002</pub-id>
<pub-id pub-id-type="pmid">35153000</pub-id>
</citation>
</ref>
<ref id="B50">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Liu</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Yan</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Howland</surname>
<given-names>M. C.</given-names>
</name>
<name>
<surname>Kwa</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Revzin</surname>
<given-names>A.</given-names>
</name>
</person-group> (<year>2011</year>). <article-title>Micropatterned aptasensors for continuous monitoring of cytokine release from human leukocytes</article-title>. <source>Anal. Chem.</source> <volume>83</volume>, <fpage>8286</fpage>&#x2013;<lpage>8292</lpage>. <pub-id pub-id-type="doi">10.1021/ac202117g</pub-id>
<pub-id pub-id-type="pmid">21942846</pub-id>
</citation>
</ref>
<ref id="B51">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Liu</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Germain</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Pappas</surname>
<given-names>D.</given-names>
</name>
</person-group> (<year>2014</year>). <article-title>Microfluidic antibody arrays for simultaneous cell separation and stimulus</article-title>. <source>Anal. Bioanal. Chem.</source> <volume>406</volume>, <fpage>7867</fpage>&#x2013;<lpage>7873</lpage>. <pub-id pub-id-type="doi">10.1007/s00216-014-8244-3</pub-id>
<pub-id pub-id-type="pmid">25354890</pub-id>
</citation>
</ref>
<ref id="B52">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Liu</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Matharu</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Rahimian</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Revzin</surname>
<given-names>A.</given-names>
</name>
</person-group> (<year>2015</year>). <article-title>Detecting multiple cell-secreted cytokines from the same aptamer-functionalized electrode</article-title>. <source>Biosens. Bioelectron.</source> <volume>64</volume>, <fpage>43</fpage>&#x2013;<lpage>50</lpage>. <pub-id pub-id-type="doi">10.1016/j.bios.2014.08.034</pub-id>
<pub-id pub-id-type="pmid">25189099</pub-id>
</citation>
</ref>
<ref id="B53">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Liu</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Chu</surname>
<given-names>C. H.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Ozkaya&#x2010;Ahmadov</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Civelekoglu</surname>
<given-names>O.</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>D.</given-names>
</name>
<etal/>
</person-group> (<year>2019</year>). <article-title>Combinatorial immunophenotyping of cell populations with an electronic antibody microarray</article-title>. <source>Small</source> <volume>15</volume>, <fpage>e1904732</fpage>. <pub-id pub-id-type="doi">10.1002/smll.201904732</pub-id>
<pub-id pub-id-type="pmid">31631578</pub-id>
</citation>
</ref>
<ref id="B54">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Liu</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Arifuzzman</surname>
<given-names>A. K. M.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Civelekoglu</surname>
<given-names>O.</given-names>
</name>
<name>
<surname>Sarioglu</surname>
<given-names>A. F.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Electronic immunoaffinity assay for differential leukocyte counts</article-title>. <source>J. Microelectromechanical Syst.</source> <volume>29</volume>, <fpage>942</fpage>&#x2013;<lpage>947</lpage>. <pub-id pub-id-type="doi">10.1109/jmems.2020.3012305</pub-id>
</citation>
</ref>
<ref id="B55">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Liu</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Chu</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Guo</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Zeng</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Shangguan</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>He</surname>
<given-names>F.</given-names>
</name>
<etal/>
</person-group> (<year>2024</year>). <article-title>Challenges of cell counting in cell therapy products</article-title>. <source>Cell Transpl.</source> <volume>33</volume>, <fpage>09636897241293628</fpage>. <pub-id pub-id-type="doi">10.1177/09636897241293628</pub-id>
<pub-id pub-id-type="pmid">39462979</pub-id>
</citation>
</ref>
<ref id="B56">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lopes</surname>
<given-names>A. N. R.</given-names>
</name>
<name>
<surname>Sinclair</surname>
<given-names>A.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Cost analysis of vein-to-vein CAR T-cell therapy: automated manufacturing and supply chain</article-title>. <source>Cell and Gene Ther. Insights</source> <volume>6</volume> (<issue>3</issue>), <fpage>487</fpage>&#x2013;<lpage>510</lpage>. <pub-id pub-id-type="doi">10.18609/cgti.2020.058</pub-id>
</citation>
</ref>
<ref id="B57">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lu</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Ang</surname>
<given-names>Y. S.</given-names>
</name>
<name>
<surname>Cheung</surname>
<given-names>K. W.</given-names>
</name>
<name>
<surname>Quek</surname>
<given-names>K. Y.</given-names>
</name>
<name>
<surname>Sin</surname>
<given-names>W. X.</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>E.</given-names>
</name>
<etal/>
</person-group> (<year>2024</year>). <article-title>iSECRETE: integrating microfluidics and DNA proximity amplification for synchronous single-cell activation and IFN-&#x3b3; secretion profiling</article-title>. <source>Adv. Sci.</source> <volume>11</volume>, <fpage>2309920</fpage>. <pub-id pub-id-type="doi">10.1002/advs.202309920</pub-id>
<pub-id pub-id-type="pmid">39175207</pub-id>
</citation>
</ref>
<ref id="B58">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ma</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Liu</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Ma</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Chand</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Patwardhan</surname>
<given-names>S.</given-names>
</name>
<etal/>
</person-group> (<year>2023</year>). <article-title>A digital nanoplasmonic microarray immunosensor for multiplexed cytokine monitoring during CAR T-cell therapy from a leukemia tumor microenvironment model</article-title>. <source>Biosens. Bioelectron.</source> <volume>230</volume>, <fpage>115247</fpage>. <pub-id pub-id-type="doi">10.1016/j.bios.2023.115247</pub-id>
<pub-id pub-id-type="pmid">37023552</pub-id>
</citation>
</ref>
<ref id="B59">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Machietto</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Giacobbe</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Perazzelli</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Hofmann</surname>
<given-names>T. J.</given-names>
</name>
<name>
<surname>Leahy</surname>
<given-names>A. B.</given-names>
</name>
<name>
<surname>Grupp</surname>
<given-names>S. A.</given-names>
</name>
<etal/>
</person-group> (<year>2023</year>). <article-title>Chimeric antigen receptor T cell manufacturing on an automated cell processor</article-title>. <source>Jove-Journal Vis. Exp.</source> <volume>198</volume>.</citation>
</ref>
<ref id="B60">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Marton</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Cl&#xe9;menceau</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Dachy</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Demerle</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Derenne</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Ferrand</surname>
<given-names>C.</given-names>
</name>
<etal/>
</person-group> (<year>2025</year>). <article-title>Harmonisation of quality control tests for academic production of CAR-T cells: a position paper from the WP-bioproduction of the UNITC consortium</article-title>. <source>Bone Marrow Transplant.</source> <volume>60</volume>, <fpage>1209</fpage>&#x2013;<lpage>1217</lpage>. <pub-id pub-id-type="doi">10.1038/s41409-025-02637-8</pub-id>
<pub-id pub-id-type="pmid">40442256</pub-id>
</citation>
</ref>
<ref id="B61">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mock</surname>
<given-names>U.</given-names>
</name>
<name>
<surname>Nickolay</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Philip</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Cheung</surname>
<given-names>G. W.-K.</given-names>
</name>
<name>
<surname>Zhan</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Johnston</surname>
<given-names>I. C. D.</given-names>
</name>
<etal/>
</person-group> (<year>2016</year>). <article-title>Automated manufacturing of chimeric antigen receptor T cells for adoptive immunotherapy using CliniMACS prodigy</article-title>. <source>Cytotherapy</source> <volume>18</volume>, <fpage>1002</fpage>&#x2013;<lpage>1011</lpage>. <pub-id pub-id-type="doi">10.1016/j.jcyt.2016.05.009</pub-id>
<pub-id pub-id-type="pmid">27378344</pub-id>
</citation>
</ref>
<ref id="B62">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mohd Noor</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Masuda</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Arai</surname>
<given-names>F.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Microfluidic device for rapid investigation of the deformability of leukocytes in whole blood samples</article-title>. <source>Robomech J.</source> <volume>7</volume>, <fpage>5</fpage>. <pub-id pub-id-type="doi">10.1186/s40648-019-0153-y</pub-id>
</citation>
</ref>
<ref id="B63">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Moon</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Gurkan</surname>
<given-names>U. A.</given-names>
</name>
<name>
<surname>Blander</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Fawzi</surname>
<given-names>W. W.</given-names>
</name>
<name>
<surname>Aboud</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Mugusi</surname>
<given-names>F.</given-names>
</name>
<etal/>
</person-group> (<year>2011</year>). <article-title>Enumeration of CD4&#x2b; T-cells using a portable microchip count platform in Tanzanian HIV-infected patients</article-title>. <source>PLoS One</source> <volume>6</volume>, <fpage>e21409</fpage>. <pub-id pub-id-type="doi">10.1371/journal.pone.0021409</pub-id>
<pub-id pub-id-type="pmid">21754988</pub-id>
</citation>
</ref>
<ref id="B64">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Noor</surname>
<given-names>A. M.</given-names>
</name>
<name>
<surname>Masuda</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Lei</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Horio</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Miyata</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Namatame</surname>
<given-names>M.</given-names>
</name>
<etal/>
</person-group> (<year>2018</year>). <article-title>A microfluidic chip for capturing, imaging and counting CD3<sup>&#x2b;</sup> T-lymphocytes and CD19<sup>&#x2b;</sup> B-lymphocytes from whole blood</article-title>. <source>Sensors Actuators B-Chemical</source> <volume>276</volume>, <fpage>107</fpage>&#x2013;<lpage>113</lpage>. <pub-id pub-id-type="doi">10.1016/j.snb.2018.08.063</pub-id>
</citation>
</ref>
<ref id="B65">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Panwar</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Roy</surname>
<given-names>R.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Integrated Field&#x27;s metal microelectrodes based microfluidic impedance cytometry for cell-in-droplet quantification</article-title>. <source>Microelectron. Eng.</source> <volume>215</volume>, <fpage>111010</fpage>. <pub-id pub-id-type="doi">10.1016/j.mee.2019.111010</pub-id>
</citation>
</ref>
<ref id="B66">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Park</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Son</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Hwang</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Ko</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Doh</surname>
<given-names>J.</given-names>
</name>
<etal/>
</person-group> (<year>2019</year>). <article-title>High-throughput microfluidic 3D cytotoxicity assay for cancer immunotherapy (CACI-IMPACT platform)</article-title>. <source>Front. Immunol.</source> <volume>10</volume>, <fpage>1133</fpage>. <pub-id pub-id-type="doi">10.3389/fimmu.2019.01133</pub-id>
<pub-id pub-id-type="pmid">31191524</pub-id>
</citation>
</ref>
<ref id="B67">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Phi</surname>
<given-names>H. T.</given-names>
</name>
<name>
<surname>Nguyen</surname>
<given-names>P. V.</given-names>
</name>
<name>
<surname>Pham</surname>
<given-names>T. V.</given-names>
</name>
<name>
<surname>Hoang</surname>
<given-names>H. V.</given-names>
</name>
<name>
<surname>Luu</surname>
<given-names>Q. M.</given-names>
</name>
<name>
<surname>Nguyen</surname>
<given-names>T. D.</given-names>
</name>
<etal/>
</person-group> (<year>2025</year>). <article-title>A novel approach to detect CD4 T-lymphocytes using a microfluidic chip and compact signal processing circuit</article-title>. <source>Microfluid. Nanofluidics</source> <volume>29</volume>, <fpage>10</fpage>. <pub-id pub-id-type="doi">10.1007/s10404-024-02782-4</pub-id>
</citation>
</ref>
<ref id="B68">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Qiu</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Gong</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Qiao</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Ge</surname>
<given-names>S.</given-names>
</name>
<etal/>
</person-group> (<year>2018</year>). <article-title>A single-bead-based, fully integrated microfluidic system for high-throughput CD4&#x2b;T lymphocyte enumeration</article-title>. <source>SLAS Technol.</source> <volume>23</volume>, <fpage>134</fpage>&#x2013;<lpage>143</lpage>. <pub-id pub-id-type="doi">10.1177/2472630317737016</pub-id>
<pub-id pub-id-type="pmid">29028426</pub-id>
</citation>
</ref>
<ref id="B69">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Rodriguez</surname>
<given-names>W. R.</given-names>
</name>
<name>
<surname>Christodoulides</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Floriano</surname>
<given-names>P. N.</given-names>
</name>
<name>
<surname>Graham</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Mohanty</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Dixon</surname>
<given-names>M.</given-names>
</name>
<etal/>
</person-group> (<year>2005</year>). <article-title>A microchip CD4 counting method for HIV monitoring in resource-poor settings</article-title>. <source>PLoS Med.</source> <volume>2</volume>, <fpage>e182</fpage>. <pub-id pub-id-type="doi">10.1371/journal.pmed.0020182</pub-id>
<pub-id pub-id-type="pmid">16013921</pub-id>
</citation>
</ref>
<ref id="B70">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ronteix</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Jain</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Angely</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Cazaux</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Khazen</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Bousso</surname>
<given-names>P.</given-names>
</name>
<etal/>
</person-group> (<year>2022</year>). <article-title>High resolution microfluidic assay and probabilistic modeling reveal cooperation between T cells in tumor killing</article-title>. <source>Nat. Commun.</source> <volume>13</volume>, <fpage>3111</fpage>. <pub-id pub-id-type="doi">10.1038/s41467-022-30575-2</pub-id>
<pub-id pub-id-type="pmid">35661707</pub-id>
</citation>
</ref>
<ref id="B71">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Rossi</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Dannhauser</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Telesco</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Netti</surname>
<given-names>P. A.</given-names>
</name>
<name>
<surname>Causa</surname>
<given-names>F.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>CD4&#x2b;: Versus CD8&#x2b; T-lymphocyte identification in an integrated microfluidic chip using light scattering and machine learning</article-title>. <source>Lab a Chip</source> <volume>19</volume>, <fpage>3888</fpage>&#x2013;<lpage>3898</lpage>. <pub-id pub-id-type="doi">10.1039/c9lc00695h</pub-id>
<pub-id pub-id-type="pmid">31641710</pub-id>
</citation>
</ref>
<ref id="B72">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Rotte</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Frigault</surname>
<given-names>M. J.</given-names>
</name>
<name>
<surname>Ansari</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Gliner</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Heery</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Shah</surname>
<given-names>B.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Dose&#x2013;response correlation for CAR-T cells: a systematic review of clinical studies</article-title>. <source>J. Immunother. Cancer</source> <volume>10</volume>, <fpage>e005678</fpage>. <pub-id pub-id-type="doi">10.1136/jitc-2022-005678</pub-id>
<pub-id pub-id-type="pmid">36549782</pub-id>
</citation>
</ref>
<ref id="B73">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sarkar</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Sabhachandani</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Stroopinsky</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Palmer</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Cohen</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Rosenblatt</surname>
<given-names>J.</given-names>
</name>
<etal/>
</person-group> (<year>2016</year>). <article-title>Dynamic analysis of immune and cancer cell interactions at single cell level in microfluidic droplets</article-title>. <source>Biomicrofluidics</source> <volume>10</volume>, <fpage>054115</fpage>. <pub-id pub-id-type="doi">10.1063/1.4964716</pub-id>
<pub-id pub-id-type="pmid">27795747</pub-id>
</citation>
</ref>
<ref id="B74">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sarkar</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Kang</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Jiang</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Ray</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Luther</surname>
<given-names>E.</given-names>
</name>
<etal/>
</person-group> (<year>2020</year>). <article-title>Machine learning-aided quantification of antibody-based cancer immunotherapy by natural killer cells in microfluidic droplets</article-title>. <source>Lab a Chip</source> <volume>20</volume>, <fpage>2317</fpage>&#x2013;<lpage>2327</lpage>. <pub-id pub-id-type="doi">10.1039/d0lc00158a</pub-id>
<pub-id pub-id-type="pmid">32458907</pub-id>
</citation>
</ref>
<ref id="B75">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sekhwama</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Mpofu</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Sivarasu</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Mthunzi-Kufa</surname>
<given-names>P.</given-names>
</name>
</person-group> (<year>2024</year>). <article-title>Applications of microfluidics in biosensing</article-title>. <source>Discov. Appl. Sci.</source> <volume>6</volume>, <fpage>303</fpage>. <pub-id pub-id-type="doi">10.1007/s42452-024-05981-4</pub-id>
</citation>
</ref>
<ref id="B76">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Son</surname>
<given-names>K. J.</given-names>
</name>
<name>
<surname>Rahimian</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Shin</surname>
<given-names>D. S.</given-names>
</name>
<name>
<surname>Siltanen</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Patel</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Revzin</surname>
<given-names>A.</given-names>
</name>
</person-group> (<year>2016</year>). <article-title>Microfluidic compartments with sensing microbeads for dynamic monitoring of cytokine and exosome release from single cells</article-title>. <source>Analyst</source> <volume>141</volume>, <fpage>679</fpage>&#x2013;<lpage>688</lpage>. <pub-id pub-id-type="doi">10.1039/c5an01648g</pub-id>
<pub-id pub-id-type="pmid">26525740</pub-id>
</citation>
</ref>
<ref id="B77">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Song</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Yan</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Song</surname>
<given-names>Y.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Automatic detecting and counting magnetic beads-labeled target cells from a suspension in a microfluidic chip</article-title>. <source>Electrophoresis</source> <volume>40</volume>, <fpage>897</fpage>&#x2013;<lpage>905</lpage>. <pub-id pub-id-type="doi">10.1002/elps.201800345</pub-id>
<pub-id pub-id-type="pmid">30379341</pub-id>
</citation>
</ref>
<ref id="B78">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Song</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Zhao</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Cai</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Stephens</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Su</surname>
<given-names>S. H.</given-names>
</name>
<name>
<surname>Sandford</surname>
<given-names>E.</given-names>
</name>
<etal/>
</person-group> (<year>2021</year>). <article-title>Machine learning-based cytokine microarray digital immunoassay analysis</article-title>. <source>Biosens. Bioelectron.</source> <volume>180</volume>, <fpage>113088</fpage>. <pub-id pub-id-type="doi">10.1016/j.bios.2021.113088</pub-id>
<pub-id pub-id-type="pmid">33647790</pub-id>
</citation>
</ref>
<ref id="B79">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sullivan</surname>
<given-names>M. R.</given-names>
</name>
<name>
<surname>Ugolini</surname>
<given-names>G. S.</given-names>
</name>
<name>
<surname>Sarkar</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Kang</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Smith</surname>
<given-names>E. C.</given-names>
</name>
<name>
<surname>Mckenney</surname>
<given-names>S.</given-names>
</name>
<etal/>
</person-group> (<year>2020</year>). <article-title>Quantifying the efficacy of checkpoint inhibitors on CD8&#x2b; cytotoxic T cells for immunotherapeutic applications via single-cell interaction</article-title>. <source>Cell Death Dis.</source> <volume>11</volume>, <fpage>979</fpage>. <pub-id pub-id-type="doi">10.1038/s41419-020-03173-7</pub-id>
<pub-id pub-id-type="pmid">33188167</pub-id>
</citation>
</ref>
<ref id="B80">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Trainor</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Purpura</surname>
<given-names>K. A.</given-names>
</name>
<name>
<surname>Middleton</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Fargo</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Hails</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Vicentini-Hogan</surname>
<given-names>M.</given-names>
</name>
<etal/>
</person-group> (<year>2023</year>). <article-title>Automated production of gene-modified chimeric antigen receptor T cells using the cocoon platform</article-title>. <source>Cytotherapy</source> <volume>25</volume>, <fpage>1349</fpage>&#x2013;<lpage>1360</lpage>. <pub-id pub-id-type="doi">10.1016/j.jcyt.2023.07.012</pub-id>
<pub-id pub-id-type="pmid">37690020</pub-id>
</citation>
</ref>
<ref id="B81">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Tran</surname>
<given-names>T. M.</given-names>
</name>
<name>
<surname>Kim</surname>
<given-names>S. C.</given-names>
</name>
<name>
<surname>Modavi</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Abate</surname>
<given-names>A. R.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Robotic automation of droplet microfluidics</article-title>. <source>Biomicrofluidics</source> <volume>16</volume>, <fpage>014102</fpage>. <pub-id pub-id-type="doi">10.1063/5.0064265</pub-id>
<pub-id pub-id-type="pmid">35145570</pub-id>
</citation>
</ref>
<ref id="B82">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Tu</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Wu</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Xia</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Hu</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Ding</surname>
<given-names>Z.</given-names>
</name>
<etal/>
</person-group> (<year>2020</year>). <article-title>Profiling of immune-cancer interactions at the single-cell level using a microfluidic well array</article-title>. <source>Analyst</source> <volume>145</volume>, <fpage>4138</fpage>&#x2013;<lpage>4147</lpage>. <pub-id pub-id-type="doi">10.1039/d0an00110d</pub-id>
<pub-id pub-id-type="pmid">32409799</pub-id>
</citation>
</ref>
<ref id="B83">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Usheva</surname>
<given-names>Z. I.</given-names>
</name>
<name>
<surname>Petersen</surname>
<given-names>D. L.</given-names>
</name>
<name>
<surname>Barington</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Mouritzen</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Barnkob</surname>
<given-names>M. B.</given-names>
</name>
</person-group> (<year>2025</year>). <article-title>Droplet-based cytotoxicity assay to assess chimeric antigen receptor T cells at the single-cell level</article-title>. <source>J. Vis. Exp.</source> <volume>217</volume>. <pub-id pub-id-type="doi">10.3791/67657</pub-id>
<pub-id pub-id-type="pmid">40163390</pub-id>
</citation>
</ref>
<ref id="B84">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>Van Den Bos</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Keefe</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Keville</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Mccaman</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2023</year>). &#x201c;<article-title>Manufacturing and quality of advanced therapeutics: cellular therapies, CAR-T and gene therapies</article-title>,&#x201d; in <source>Biopharmaceutical manufacturing</source> (<publisher-name>Springer International Publishing</publisher-name>).</citation>
</ref>
<ref id="B85">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wang</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Kelley</surname>
<given-names>S. O.</given-names>
</name>
</person-group> (<year>2025</year>). <article-title>Microfluidic technologies for enhancing the potency, predictability and affordability of adoptive cell therapies</article-title>. <source>Nat. Biomed. Eng.</source> <volume>9</volume>, <fpage>803</fpage>&#x2013;<lpage>821</lpage>. <pub-id pub-id-type="doi">10.1038/s41551-024-01315-2</pub-id>
<pub-id pub-id-type="pmid">39953325</pub-id>
</citation>
</ref>
<ref id="B86">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wang</surname>
<given-names>Y. N.</given-names>
</name>
<name>
<surname>Kang</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Xu</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Chon</surname>
<given-names>C. H.</given-names>
</name>
<name>
<surname>Barnett</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Kalams</surname>
<given-names>S. A.</given-names>
</name>
<etal/>
</person-group> (<year>2008</year>). <article-title>On-chip counting the number and the percentage of CD4&#x2b; T lymphocytes</article-title>. <source>Lab a Chip</source> <volume>8</volume>, <fpage>309</fpage>&#x2013;<lpage>315</lpage>. <pub-id pub-id-type="doi">10.1039/b713932b</pub-id>
<pub-id pub-id-type="pmid">18231671</pub-id>
</citation>
</ref>
<ref id="B87">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Watkins</surname>
<given-names>N. N.</given-names>
</name>
<name>
<surname>Hassan</surname>
<given-names>U.</given-names>
</name>
<name>
<surname>Damhorst</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Ni</surname>
<given-names>H. K.</given-names>
</name>
<name>
<surname>Vaid</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Rodriguez</surname>
<given-names>W.</given-names>
</name>
<etal/>
</person-group> (<year>2013</year>). <article-title>Microfluidic CD4(&#x2b;) and CD8(&#x2b;) T lymphocyte counters for point-of-care HIV diagnostics using whole blood</article-title>. <source>Sci. Transl. Med.</source> <volume>5</volume>, <fpage>214ra170</fpage>. <pub-id pub-id-type="doi">10.1126/scitranslmed.3006870</pub-id>
<pub-id pub-id-type="pmid">24307694</pub-id>
</citation>
</ref>
<ref id="B88">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wong</surname>
<given-names>K. U.</given-names>
</name>
<name>
<surname>Shi</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Jia</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Deng</surname>
<given-names>C.</given-names>
</name>
<etal/>
</person-group> (<year>2022</year>). <article-title>Assessment of chimeric antigen receptor T cytotoxicity by droplet microfluidics <italic>in vitro</italic>
</article-title>. <source>Antib. Ther.</source> <volume>5</volume>, <fpage>85</fpage>&#x2013;<lpage>99</lpage>. <pub-id pub-id-type="doi">10.1093/abt/tbac008</pub-id>
<pub-id pub-id-type="pmid">35441124</pub-id>
</citation>
</ref>
<ref id="B89">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Xue</surname>
<given-names>Q.</given-names>
</name>
<name>
<surname>Bettini</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Paczkowski</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Ng</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Kaiser</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Mcconnell</surname>
<given-names>T.</given-names>
</name>
<etal/>
</person-group> (<year>2017</year>). <article-title>Single-cell multiplexed cytokine profiling of CD19 CAR-T cells reveals a diverse landscape of polyfunctional antigen-specific response</article-title>. <source>J. Immunother. Cancer</source> <volume>5</volume>, <fpage>85</fpage>. <pub-id pub-id-type="doi">10.1186/s40425-017-0293-7</pub-id>
<pub-id pub-id-type="pmid">29157295</pub-id>
</citation>
</ref>
<ref id="B90">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhang</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Pappas</surname>
<given-names>D.</given-names>
</name>
</person-group> (<year>2016</year>). <article-title>Microfluidic cell surface antigen expression analysis using a single antibody type</article-title>. <source>Analyst</source> <volume>141</volume>, <fpage>1440</fpage>&#x2013;<lpage>1447</lpage>. <pub-id pub-id-type="doi">10.1039/c5an02338f</pub-id>
<pub-id pub-id-type="pmid">26814637</pub-id>
</citation>
</ref>
<ref id="B91">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhang</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Zhou</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Lyons</surname>
<given-names>V.</given-names>
</name>
<name>
<surname>Johnson</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Venable</surname>
<given-names>A.</given-names>
</name>
<etal/>
</person-group> (<year>2018</year>). <article-title>Multiparameter affinity microchip for early sepsis diagnosis based on CD64 and CD69 expression and cell capture</article-title>. <source>Anal. Chem.</source> <volume>90</volume>, <fpage>7204</fpage>&#x2013;<lpage>7211</lpage>. <pub-id pub-id-type="doi">10.1021/acs.analchem.7b05305</pub-id>
<pub-id pub-id-type="pmid">29799723</pub-id>
</citation>
</ref>
<ref id="B92">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhou</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Johnson</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Venable</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Griswold</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Pappas</surname>
<given-names>D.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Detection of culture-negative sepsis in clinical blood samples using a microfluidic assay for combined CD64 and CD69 cell capture</article-title>. <source>Anal. Chim. Acta</source> <volume>1062</volume>, <fpage>110</fpage>&#x2013;<lpage>117</lpage>. <pub-id pub-id-type="doi">10.1016/j.aca.2019.02.039</pub-id>
<pub-id pub-id-type="pmid">30947986</pub-id>
</citation>
</ref>
<ref id="B93">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhou</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Shao</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Bessa De Castro</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Ma</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Liu</surname>
<given-names>X.</given-names>
</name>
<etal/>
</person-group> (<year>2020</year>). <article-title>Evaluation of single-cell cytokine secretion and cell-cell interactions with a hierarchical loading microwell chip</article-title>. <source>Cell Rep.</source> <volume>31</volume>, <fpage>107574</fpage>. <pub-id pub-id-type="doi">10.1016/j.celrep.2020.107574</pub-id>
<pub-id pub-id-type="pmid">32348757</pub-id>
</citation>
</ref>
<ref id="B94">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zia</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Pizzuti</surname>
<given-names>V.</given-names>
</name>
<name>
<surname>Paris</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Alviano</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Bonsi</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Zattoni</surname>
<given-names>A.</given-names>
</name>
<etal/>
</person-group> (<year>2024</year>). <article-title>Emerging technologies for quality control of cell-based, advanced therapy medicinal products</article-title>. <source>J. Pharm. Biomed. Anal.</source> <volume>246</volume>, <fpage>116182</fpage>. <pub-id pub-id-type="doi">10.1016/j.jpba.2024.116182</pub-id>
<pub-id pub-id-type="pmid">38772202</pub-id>
</citation>
</ref>
</ref-list>
<sec id="s14">
<title>Glossary</title>
<def-list>
<def-item>
<term id="G1-fbioe.2025.1613836">
<bold>ATMP</bold>
</term>
<def>
<p>Advanced Therapy Medicinal Products: Medicines based on genes (gene therapy), cells (cell therapy), or tissues (tissue-engineered therapy) to repair or replace damaged functions</p>
</def>
</def-item>
<def-item>
<term id="G2-fbioe.2025.1613836">
<bold>CAR</bold>
</term>
<def>
<p>Chimeric Antigen Receptor: a receptor which is engineered into a T Cell in order to recognize a specific antigen on cancer cells</p>
</def>
</def-item>
<def-item>
<term id="G3-fbioe.2025.1613836">
<bold>CCD</bold>
</term>
<def>
<p>Charged-Coupled Device: a semiconductor chip which translates light into electrical charge, for example, in a CCD camera</p>
</def>
</def-item>
<def-item>
<term id="G4-fbioe.2025.1613836">
<bold>CD3</bold>
</term>
<def>
<p>Cluster of Differentiation; name and classification system for cell surface molecules, i.e. markers, for example, on white blood cells</p>
</def>
</def-item>
<def-item>
<term id="G5-fbioe.2025.1613836">
<bold>COGs</bold>
</term>
<def>
<p>Cost of Goods: the direct costs necessary to produce goods; for ATMPs, COGs include raw materials (e.g. viral vectors), labor (e.g. highly trained technicians), manufacturing facilities (GMP clean rooms), patient-specific costs such as cell collection and cold chain storage</p>
</def>
</def-item>
<def-item>
<term id="G6-fbioe.2025.1613836">
<bold>CQA</bold>
</term>
<def>
<p>Critical Quality Attributes: a property of a product that must be controlled to ensure safety, efficacy, and quality of the product; see Table 1 for CQAs in CAR T cell manufacturing</p>
</def>
</def-item>
<def-item>
<term id="G7-fbioe.2025.1613836">
<bold>DPA</bold>
</term>
<def>
<p>DNA proximity assay: an assay to detect whether molecules are close to each other; converts proximity into a DNA signal</p>
</def>
</def-item>
<def-item>
<term id="G8-fbioe.2025.1613836">
<bold>ECM</bold>
</term>
<def>
<p>Extracellular Matrix: the three-dimensional network of proteins and polysaccharides surrounding the cells, providing structural and biochemical support</p>
</def>
</def-item>
<def-item>
<term id="G9-fbioe.2025.1613836">
<bold>EHD</bold>
</term>
<def>
<p>Electro-Hydrodynamic: a principle enabling fluid motion by using an electric field, such as pumping liquid in a microfluidic channel</p>
</def>
</def-item>
<def-item>
<term id="G10-fbioe.2025.1613836">
<bold>FDA</bold>
</term>
<def>
<p>Food and Drug Administration: US government agency responsible for approval of medicines</p>
</def>
</def-item>
<def-item>
<term id="G11-fbioe.2025.1613836">
<bold>ELISA</bold>
</term>
<def>
<p>Enzyme-Linked Immunosorbent Assays: an antibody-based test which detects and quantifies biomolecules by using an enzyme-linked color change</p>
</def>
</def-item>
<def-item>
<term id="G12-fbioe.2025.1613836">
<bold>GM-CSF</bold>
</term>
<def>
<p>Granulocyte-Macrophage Colony-Stimulating Factor: a cytokine which promotes the growth of granulocytes and macrophages</p>
</def>
</def-item>
<def-item>
<term id="G13-fbioe.2025.1613836">
<bold>GMP</bold>
</term>
<def>
<p>Good Manufacturing Practice: a set of regulations ensuring medicines are consistently produced and controlled to quality standards</p>
</def>
</def-item>
<def-item>
<term id="G14-fbioe.2025.1613836">
<bold>Granzyme B</bold>
</term>
<def>
<p>A cytotoxic protease released by T cells and NK cells to induce target cell death</p>
</def>
</def-item>
<def-item>
<term id="G15-fbioe.2025.1613836">
<bold>IFN</bold>
</term>
<def>
<p>Interferon: cytokines that boost antiviral defence and regulate immune responses</p>
</def>
</def-item>
<def-item>
<term id="G16-fbioe.2025.1613836">
<bold>IL</bold>
</term>
<def>
<p>Interleukin: family of cytokines that mediate communication between immune cells</p>
</def>
</def-item>
<def-item>
<term id="G17-fbioe.2025.1613836">
<bold>LoD</bold>
</term>
<def>
<p>Limit of Detection: the lowest concentration of a substance that can be reliably detected by the assay</p>
</def>
</def-item>
<def-item>
<term id="G18-fbioe.2025.1613836">
<bold>MIP</bold>
</term>
<def>
<p>Macrophage Inflammatory Protein: Chemokines that recruit immune cells to sites of infection or inflammation</p>
</def>
</def-item>
<def-item>
<term id="G19-fbioe.2025.1613836">
<bold>NGS</bold>
</term>
<def>
<p>Next Generation Sequencing: High-throughput DNA/RNA sequencing technology for comprehensive genetic analysis</p>
</def>
</def-item>
<def-item>
<term id="G20-fbioe.2025.1613836">
<bold>NP</bold>
</term>
<def>
<p>Nanoparticle: Nano-sized particle used in drug delivery, imaging, or diagnostics; made of different materials, for example gold nanoparticles (AuNP)</p>
</def>
</def-item>
<def-item>
<term id="G34-fbioe.2025.1613836">
<bold>PAT</bold>
</term>
<def>
<p>Process Analytical Technology: A framework for designing, analyzing, and controlling biomanufacturing processes through real-time measurement of critical quality attributes and performance parameters</p>
</def>
</def-item>
<def-item>
<term id="G21-fbioe.2025.1613836">
<bold>PBMC</bold>
</term>
<def>
<p>Peripheral Blood Mononuclear Cells: A heterogeneous population of blood cells with round nuclei, including lymphocytes (T cells, B cells, NK cells) and monocytes</p>
</def>
</def-item>
<def-item>
<term id="G22-fbioe.2025.1613836">
<bold>PDMS</bold>
</term>
<def>
<p>Poly(dimethylsiloxane): a silicone-based polymer widely used in microfluidics and biomedical devices</p>
</def>
</def-item>
<def-item>
<term id="G23-fbioe.2025.1613836">
<bold>QC</bold>
</term>
<def>
<p>Quality Control: Procedures to ensure products meet defined safety and performance standards</p>
</def>
</def-item>
<def-item>
<term id="G24-fbioe.2025.1613836">
<bold>RCL</bold>
</term>
<def>
<p>Replication-Competent Lentivirus: Lentivirus capable of replicating, monitored as a safety risk in gene therapy</p>
</def>
</def-item>
<def-item>
<term id="G25-fbioe.2025.1613836">
<bold>RCR</bold>
</term>
<def>
<p>Replication-Competent Retrovirus: Retrovirus capable of replication, checked as a safety risk in retroviral vector use</p>
</def>
</def-item>
<def-item>
<term id="G26-fbioe.2025.1613836">
<bold>SERS</bold>
</term>
<def>
<p>Surface Enhanced Raman System: A sensitive spectroscopic method that enhances Raman signals using nanostructured surfaces</p>
</def>
</def-item>
<def-item>
<term id="G27-fbioe.2025.1613836">
<bold>SPRi</bold>
</term>
<def>
<p>Surface Plasmon Resonance Imaging: real-time, label-free optical analysis method for analyzing interactions between molecules</p>
</def>
</def-item>
<def-item>
<term id="G28-fbioe.2025.1613836">
<bold>T Cell</bold>
</term>
<def>
<p>T cells, also known as T lymphocytes, are a type of white blood cell that develops in the thymus gland (hence the T for thymus</p>
</def>
</def-item>
<def-item>
<term id="G29-fbioe.2025.1613836">
<bold>T-E</bold>
</term>
<def>
<p>Target-Effector: ratio describing target cells (e.g., tumor cells) versus effector cells (e.g., T or NK cells) in cytotoxicity assays</p>
</def>
</def-item>
<def-item>
<term id="G30-fbioe.2025.1613836">
<bold>TME</bold>
</term>
<def>
<p>Tumor Microenvironment: the cellular and molecular environment around a tumor that influences its growth and immune evasion</p>
</def>
</def-item>
<def-item>
<term id="G31-fbioe.2025.1613836">
<bold>TNF</bold>
</term>
<def>
<p>Tumor Necrosis Factor: a pro-inflammatory cytokine involved in immune defence and inflammation</p>
</def>
</def-item>
<def-item>
<term id="G32-fbioe.2025.1613836">
<bold>VCN</bold>
</term>
<def>
<p>Vector Copy Number: The number of therapeutic vector DNA copies integrated into the genome per cell</p>
</def>
</def-item>
<def-item>
<term id="G33-fbioe.2025.1613836">
<bold>VEGF</bold>
</term>
<def>
<p>Vascular Endothelial Growth Factor: A signalling protein that promotes new blood vessel formation</p>
</def>
</def-item>
</def-list>
</sec>
</back>
</article>