<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article article-type="research-article" dtd-version="2.3" xml:lang="EN" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Bioeng. Biotechnol.</journal-id>
<journal-title>Frontiers in Bioengineering and Biotechnology</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Bioeng. Biotechnol.</abbrev-journal-title>
<issn pub-type="epub">2296-4185</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">1264406</article-id>
<article-id pub-id-type="doi">10.3389/fbioe.2023.1264406</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Bioengineering and Biotechnology</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Electric field bridging-effect in electrified microfibrils&#x2019; scaffolds</article-title>
<alt-title alt-title-type="left-running-head">Fontana et al.</alt-title>
<alt-title alt-title-type="right-running-head">
<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3389/fbioe.2023.1264406">10.3389/fbioe.2023.1264406</ext-link>
</alt-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Fontana</surname>
<given-names>Sara</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/2381946/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
<role content-type="https://credit.niso.org/contributor-roles/data-curation/"/>
<role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/software/"/>
<role content-type="https://credit.niso.org/contributor-roles/visualization/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Caramazza</surname>
<given-names>Laura</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/850086/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
<role content-type="https://credit.niso.org/contributor-roles/data-curation/"/>
<role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/software/"/>
<role content-type="https://credit.niso.org/contributor-roles/visualization/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Marracino</surname>
<given-names>Paolo</given-names>
</name>
<xref ref-type="aff" rid="aff3">
<sup>3</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
<role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Cuenca Ortol&#xe1;</surname>
<given-names>Irene</given-names>
</name>
<xref ref-type="aff" rid="aff4">
<sup>4</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Colella</surname>
<given-names>Micol</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1476480/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
<role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Dolciotti</surname>
<given-names>Noemi</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
<role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Paffi</surname>
<given-names>Alessandra</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1322663/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
<role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Gisbert Roca</surname>
<given-names>Fernando</given-names>
</name>
<xref ref-type="aff" rid="aff4">
<sup>4</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Ivashchenko</surname>
<given-names>Sergiy</given-names>
</name>
<xref ref-type="aff" rid="aff4">
<sup>4</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>M&#xe1;s Estell&#xe9;s</surname>
<given-names>Jorge</given-names>
</name>
<xref ref-type="aff" rid="aff4">
<sup>4</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Consales</surname>
<given-names>Claudia</given-names>
</name>
<xref ref-type="aff" rid="aff5">
<sup>5</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/260849/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
<role content-type="https://credit.niso.org/contributor-roles/project-administration/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Balucani</surname>
<given-names>Marco</given-names>
</name>
<xref ref-type="aff" rid="aff3">
<sup>3</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Apollonio</surname>
<given-names>Francesca</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/205320/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
<role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/supervision/"/>
<role content-type="https://credit.niso.org/contributor-roles/software/"/>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Liberti</surname>
<given-names>Micaela</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<xref ref-type="corresp" rid="c001">&#x2a;</xref>
<uri xlink:href="https://loop.frontiersin.org/people/143331/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
<role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/software/"/>
<role content-type="https://credit.niso.org/contributor-roles/supervision/"/>
</contrib>
</contrib-group>
<aff id="aff1">
<sup>1</sup>
<institution>BioEM Lab</institution>, <institution>Department of Information Engineering</institution>, <institution>Electronics and Telecommunications (DIET)</institution>, <institution>Sapienza University of Rome</institution>, <addr-line>Rome</addr-line>, <country>Italy</country>
</aff>
<aff id="aff2">
<sup>2</sup>
<institution>Center for Life Nano- &#x26; Neuro-Science</institution>, <institution>Fondazione Istituto Italiano di Tecnologia (IIT)</institution>, <addr-line>Rome</addr-line>, <country>Italy</country>
</aff>
<aff id="aff3">
<sup>3</sup>
<institution>Rise Technology S.R.L</institution>, <addr-line>Rome</addr-line>, <country>Italy</country>
</aff>
<aff id="aff4">
<sup>4</sup>
<institution>Center for Biomaterials and Tissue Engineering</institution>, <institution>Universitat Polit&#xe8;cnica de Val&#xe8;ncia</institution>, <addr-line>Valencia</addr-line>, <country>Spain</country>
</aff>
<aff id="aff5">
<sup>5</sup>
<institution>Division of Health Protection Technologies</institution>, <institution>ENEA-Italian National Agency for New Technologies</institution>, <institution>Energy and Sustainable Economic Development</institution>, <addr-line>Rome</addr-line>, <country>Italy</country>
</aff>
<author-notes>
<fn fn-type="edited-by">
<p>
<bold>Edited by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/167996/overview">Marie-Noelle Giraud</ext-link>, Universit&#xe9; de Fribourg, Switzerland</p>
</fn>
<fn fn-type="edited-by">
<p>
<bold>Reviewed by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/434612/overview">Bin Du</ext-link>, Hebei Normal University of Science and Technology, China</p>
<p>
<ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/870133/overview">Mohammad Karimipour</ext-link>, Tabriz University of Medical Sciences, Iran</p>
</fn>
<corresp id="c001">&#x2a;Correspondence: Micaela Liberti, <email>micaela.liberti@uniroma1.it</email>
</corresp>
</author-notes>
<pub-date pub-type="epub">
<day>25</day>
<month>10</month>
<year>2023</year>
</pub-date>
<pub-date pub-type="collection">
<year>2023</year>
</pub-date>
<volume>11</volume>
<elocation-id>1264406</elocation-id>
<history>
<date date-type="received">
<day>20</day>
<month>07</month>
<year>2023</year>
</date>
<date date-type="accepted">
<day>03</day>
<month>10</month>
<year>2023</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#xa9; 2023 Fontana, Caramazza, Marracino, Cuenca Ortol&#xe1;, Colella, Dolciotti, Paffi, Gisbert Roca, Ivashchenko, M&#xe1;s Estell&#xe9;s, Consales, Balucani, Apollonio and Liberti.</copyright-statement>
<copyright-year>2023</copyright-year>
<copyright-holder>Fontana, Caramazza, Marracino, Cuenca Ortol&#xe1;, Colella, Dolciotti, Paffi, Gisbert Roca, Ivashchenko, M&#xe1;s Estell&#xe9;s, Consales, Balucani, Apollonio and Liberti</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p>
</license>
</permissions>
<abstract>
<p>
<bold>Introduction:</bold> The use of biocompatible scaffolds combined with the implantation of neural stem cells, is increasingly being investigated to promote the regeneration of damaged neural tissue, for instance, after a Spinal Cord Injury (SCI). In particular, aligned Polylactic Acid (PLA) microfibrils&#x2019; scaffolds are capable of supporting cells, promoting their survival and guiding their differentiation in neural lineage to repair the lesion. Despite its biocompatible nature, PLA is an electrically insulating material and thus it could be detrimental for increasingly common scaffolds&#x2019; electric functionalization, aimed at accelerating the cellular processes. In this context, the European RISEUP project aims to combine high intense microseconds pulses and DC stimulation with neurogenesis, supported by a PLA microfibrils&#x2019; scaffold.</p>
<p>
<bold>Methods:</bold> In this paper a numerical study on the effect of microfibrils&#x2019; scaffolds on the E-field distribution, in planar interdigitated electrodes, is presented. Realistic microfibrils&#x2019; 3D CAD models have been built to carry out a numerical dosimetry study, through Comsol Multiphysics software.</p>
<p>
<bold>Results:</bold> Under a voltage of 10&#xa0;V, microfibrils redistribute the E-field values focalizing the field streamlines in the spaces between the fibers, allowing the field to pass and reach maximum values up to 100&#xa0;kV/m and values comparable with the bare electrodes&#x2019; device (without fibers).</p>
<p>
<bold>Discussion:</bold> Globally the median E-field inside the scaffolded electrodes is the 90% of the nominal field, allowing an adequate cells&#x2019; exposure.</p>
</abstract>
<kwd-group>
<kwd>tissue engineering</kwd>
<kwd>biocompatible scaffold</kwd>
<kwd>microfibrils</kwd>
<kwd>electric stimulation</kwd>
<kwd>numerical modeling</kwd>
<kwd>dosimetry</kwd>
</kwd-group>
<custom-meta-wrap>
<custom-meta>
<meta-name>section-at-acceptance</meta-name>
<meta-value>Tissue Engineering and Regenerative Medicine</meta-value>
</custom-meta>
</custom-meta-wrap>
</article-meta>
</front>
<body>
<sec sec-type="intro" id="s1">
<title>1 Introduction</title>
<p>In the last decades, a huge interest in tissue engineering (TE) has grown, which aims at finding innovative strategies to regenerate damaged biological tissues after diseases and injuries. The innovation of TE lies in the synergy of multidisciplinary approaches, based on highly advanced engineering and life sciences (<xref ref-type="bibr" rid="B31">Langer and Vacanti, 2016</xref>), such as stem cell biology, functional biocompatible scaffolds, nanotechnology, and three-dimensional (3D) bioprinting (<xref ref-type="bibr" rid="B38">Ramos and Moroni, 2020</xref>). In particular, bioprinting involves the assembly of biomaterials, bioactive molecules, and cells that are then manufactured to obtain engineered structures to substitute the damaged tissue and restore its functions (<xref ref-type="bibr" rid="B38">Ramos and Moroni, 2020</xref>). Such technology could represent an innovative strategy within regenerative medicine, alternative to transplants, mechanical devices, or surgical reconstruction. Among the wide application fields, it is possible to mention bone, cartilage, cardiac, pancreas, skin, and vascular tissue engineering (<xref ref-type="bibr" rid="B12">Castells-Sala et al., 2015</xref>). For instance, in the field of bone TE, several innovations have been introduced, thanks to the increasingly sophisticated 3D bioprinting technology proposed in the case of bone fractures or osteo-degenerative diseases. Nonetheless, given the challenge of patient-specific bone reconstruction, vascularization, and neuronal functionalization, even 4D-printed alternatives are explored. The aforementioned technology is capable of changing over time in shape, in order to adapt to the defect area environment, as a consequence of internal cell forces or external stimuli, and in order to allow the functionalization and maturation in time of the cells (<xref ref-type="bibr" rid="B43">Wan et al., 2020</xref>).</p>
<p>Furthermore, one of the most challenging applications of TE is the treatment of the central nervous system (CNS) and peripheral nervous system (PNS) injuries, which are unlikely to self-regenerate and could even cause permanent functional deficits (<xref ref-type="bibr" rid="B5">Boni et al., 2018</xref>), resulting in 6.8 million deaths each year (<xref ref-type="bibr" rid="B45">World Health Organization, 2007</xref>). CNS pathologies, such as neurodegenerative diseases and strokes, or PNS nerve injuries could cause neural connection impairment or inflammatory states, leading to cell death. Therefore, scientific research is focused on finding clinical solutions to reestablish the original neural pathways in the damaged tissue and restore the lost functionality. Implantable biomaterial scaffolds are increasingly employed for these purposes. They can be realized with natural polymers (such as cellulose, collagen, hyaluronic acid, and gelatin) to create a stable and nutritious environment to promote tissue regeneration (<xref ref-type="bibr" rid="B40">Schmidt and Leach, 2003</xref>; <xref ref-type="bibr" rid="B44">Wang et al., 2018</xref>). Nonetheless, in the last few decades, synthetic biocompatible polymers have been drawing more attention since they are cheaper and are characterized by a higher degradation time, which makes them suitable for human implantable devices; for these reasons, they are increasingly used to host and facilitate the growth of different cell types (i.e., stem cells), charged to migrate to the injury site and heal the tissue (<xref ref-type="bibr" rid="B40">Schmidt and Leach, 2003</xref>; <xref ref-type="bibr" rid="B44">Wang et al., 2018</xref>). Among the most frequently employed polymers, we possibly mention polylactide (PLA), polyglycolide (PGA), poly-l-lactide-co-glycolide (PLGA), and polycaprolactone (PCL) (<xref ref-type="bibr" rid="B27">Janouskova, 2018</xref>). Moreover, several research groups are focused on studying the proper scaffold&#x2019;s biophysical characteristics and shape, including the addition of bioactive molecules, to promote the cell survival and proliferation and guide stem cell differentiation in the neuronal lineage (<xref ref-type="bibr" rid="B44">Wang et al., 2018</xref>).</p>
<p>Within these strategies, highly aligned fibrillar substrates have been deeply investigated to guide axonal growth in the direction of the fibers (<xref ref-type="bibr" rid="B50">Zhang et al., 2021</xref>). Specifically, the use of aligned nanofibers is useful to guide the dorsal root ganglion neurite growth and glial cell migration (<xref ref-type="bibr" rid="B13">Chow et al., 2007</xref>; <xref ref-type="bibr" rid="B14">Corey et al., 2007</xref>; <xref ref-type="bibr" rid="B41">Schnell et al., 2007</xref>; <xref ref-type="bibr" rid="B23">Gisbert Roca et al., 2020</xref>). Xie J et al. presented a conductive core-sheath PCL or PLA nanofibers&#x2019; scaffold coated with pyrrole (PPy) that showed improvement in neurite extension from cultured dorsal root ganglia (DRG) on uniaxially aligned nanofibers, compared with randomly oriented fibers&#x2019; scaffold (<xref ref-type="bibr" rid="B46">Xie et al., 2009</xref>; <xref ref-type="bibr" rid="B23">Gisbert Roca et al., 2020</xref>). Nevertheless, the scaffold&#x2019;s dimension could affect the axonal growth, which is more favored by microfiber-based substrates instead of the nanofiber-based substrates (F. <xref ref-type="bibr" rid="B23">Gisbert Roca et al., 2020</xref>; <xref ref-type="bibr" rid="B24">Gisbert Roca et al., 2022</xref>). Outcomes of Yang and colleagues&#x2019; work pointed out that the scaffold highly supports neural stem cell (NSC) cultures, which elongated along the fibers, and improves the neurite outgrowth, thus demonstrating that the aligned PLA fibrous scaffold could be a potential cell carrier in neural tissue engineering (<xref ref-type="bibr" rid="B48">Yang et al., 2005</xref>). Furthermore, a huge interest in scaffolds&#x2019; electric functionalization is growing since exogenous electric stimulation significantly increases NSC proliferation, their differentiation into the neuronal lineage, and induces guided cell migration (<xref ref-type="bibr" rid="B51">Zhu et al., 2019</xref>). Moreover, since nerve regeneration is a slow process, electrical stimulation has been introduced as an effective strategy to enhance the axonal growth speed. In <xref ref-type="bibr" rid="B47">Xu et al. (2019</xref>), a PLA/PCL microfiber&#x27;s scaffold, coated with conductive chitosan and polypyrrole (CS/PPy), has been shown to promote, under 100&#xa0;mV electric stimulation for 2&#xa0;h every day, the growth and differentiation of PC12 cells and to support the directional growth of neurites. Moreover, Lee J.Y. and co-authors demonstrated the potential use of PLGA-aligned fibers PPy-coated for nerve regeneration, by performing electrical stimulation through two silver-wired electrodes on PC12 cells and rat embryonic hippocampal neurons that showed an improved neurite outgrowth compared to the non-stimulated cells (<xref ref-type="bibr" rid="B32">Lee et al., 2009</xref>). More recently, Gisbert Roca F. and co-authors designed PLA&#x2013;PPy microfibers&#x2019; substrates, in which two gold electrodes, placed at the scaffold&#x2019;s extremes, electrically stimulated Schwann cells (SCs) and the dorsal root ganglia, showing an increase of 19.2% in the maximum length of the axons and an increase of 40% in the area occupied by the axons (<xref ref-type="bibr" rid="B24">Gisbert Roca et al., 2022</xref>).</p>
<p>Within the possible application of the aforementioned technologies, a spinal cord injury (SCI) is one of the most prominent. SCs innervate the skeletal muscles and the visceral organs through nerve bundles (<xref ref-type="bibr" rid="B19">Dowlati, 2017</xref>), and therefore, the damage of such a nervous complex, for instance, due to traumatic events, could partially or totally impair the muscle sensitivity and functionality. Traumatic SCI is increasingly recognized as a global health priority (<xref ref-type="bibr" rid="B4">Barbiellini Amidei et al., 2022</xref>), due to its mortality, morbidity impact, and the requirement of patients&#x2019; expensive healthcare system support; the estimated lifetime costs range from $ 1.5 millions to approximately $ 3 millions (<xref ref-type="bibr" rid="B17">Diop et al., 2021</xref>). Nevertheless, researchers are working on innovative treatments to restore the motor and vital functions lost. The use of electric and magnetic fields to alter specific targeted neuronal activities, known as neuromodulation (<xref ref-type="bibr" rid="B20">Famm, 2013</xref>; <xref ref-type="bibr" rid="B49">Ye et al., 2022</xref>), combined with the implantation of biocompatible material inside the lesion to induce neurogenesis, is one of the most attractive. Several studies have highlighted that SCI electric stimulation can recover volitional movements of the upper or lower limbs (<xref ref-type="bibr" rid="B2">Angeli et al., 2015</xref>; <xref ref-type="bibr" rid="B1">Angeli et al., 2018</xref>; <xref ref-type="bibr" rid="B26">James et al., 2018</xref>), and so far, epidural electrical spinal cord stimulation (EES) is the most successful strategy to restore leg motor control in incomplete SCI patients (<xref ref-type="bibr" rid="B42">Wagner et al., 2018</xref>). In a recent study carried out by <xref ref-type="bibr" rid="B39">Rowald et al. (2022</xref>), a 16-electrode array was surgically implanted on the lesioned area to activate targeted motor neurons with a predefined timing to reproduce the natural spatiotemporal activation pattern during walking. Anyway, EES is limited due to the necessity of a sufficient amount of surviving fibers (<xref ref-type="bibr" rid="B21">Formento et al., 2018</xref>); moreover, such a technique does not restore motor autonomy. Alternative strategies able to induce neurogenesis from NSCs, in permissive and guiding biomaterial scaffold environments to overcome the low probability of cell survival, are currently being investigated. The neurogenesis process exploits cell differentiation into the neuronal lineage, in order to generate a tissue bridge that re-innervates the lesioned area (<xref ref-type="bibr" rid="B30">Kumamaru et al., 2019</xref>; <xref ref-type="bibr" rid="B15">Damianakis et al., 2022</xref>). In this context, an innovative initiative has been proposed within the European project RISEUP<xref ref-type="fn" rid="fn1">
<sup>1</sup>
</xref> that can combine electric stimulation with neurogenesis to be supported by a biocompatible microfibril&#x27;s scaffold. The project aims at the regeneration of the injured spinal cord through the development of an implantable electro pulsed biohybrid (EPB) device that supports and guides the differentiation of human induced neural stem cells (iNSCs) combined with mesenchymal stem cells (MSCs) (<xref ref-type="bibr" rid="B8">Caramazza et al., 2021a</xref>; <xref ref-type="bibr" rid="B7">Caramazza et al., 2022</xref>) through a highly intense and ultrashort pulsed electric field, as intense as those used in electroporation-based technologies (<xref ref-type="bibr" rid="B6">Breton and Mir, 2012</xref>; <xref ref-type="bibr" rid="B29">Kotnik et al., 2019</xref>; <xref ref-type="bibr" rid="B9">Caramazza et al., 2020a</xref>; <xref ref-type="bibr" rid="B11">Caramazza, et al., 2021b</xref>; <xref ref-type="bibr" rid="B35">Marracino et al., 2021</xref>), and direct current (DC) stimulation protocols to guide cell migration (<xref ref-type="bibr" rid="B18">Dong et al., 2019</xref>; <xref ref-type="bibr" rid="B10">Caramazza, et al., 2020b</xref>; <xref ref-type="bibr" rid="B36">Naskar et al., 2020</xref>), to generate a biohybrid cell bridge on the lesion. From a technological point of view, the EPB device is represented by a set of interdigitated alternating active and ground planar electrodes, to provide DC or pulsed electric fields with 100 &#xb5;s duration (&#xb5;sPEFs) stimulation, on which a biocompatible microfibril-based scaffold will be posed to host the target cells. The EPB will use PLA as a scaffold since it is well-known that this polymer is synthetic, biocompatible, biodegradable, and bioabsorbable in the human body and it has been approved by the U.S. Food and Drug Administration (FDA) for nerve regeneration pipelines (<xref ref-type="bibr" rid="B33">Liu et al., 2017</xref>; <xref ref-type="bibr" rid="B50">Zhang et al., 2021</xref>). Nevertheless, PLA is an insulating material; thus, the microfibrils&#x2019; layer could affect the electric field distribution due to the planar electrodes inside the scaffold and could limit cell exposure, compromising the tissue regeneration efficacy.</p>
<p>For this reason, in this paper, we present a numerical study of the PLA microfibrils&#x2019; influence on the E-field distribution generated by interdigitated electrodes, to evaluate if the use of such a technology could be compatible with the electric stimulation of cells. The work proposed in this paper is the first and a fundamental step in EPB design that is going to be realized and used in the future for further <italic>in vitro</italic> and <italic>in vivo</italic> investigations planned in the project RISEUP. For these purposes, the reconstruction of realistic microfibrils&#x2019; models is needed, and in the following paragraphs, a detailed description of the reconstruction procedure fine-tuned, based on images of the produced microfibrils, will be discussed. The electrical performances of the EPB models obtained with different microfibril distributions are evaluated through numerical simulations. All the results are compared with the electrodes&#x2019; device model without microfibrils, to assess the differences with the nominal E-field and to obtain a deep awareness of the possible cell exposure scenarios, as a function of the microfibrils&#x2019; spatial distribution parameters.</p>
</sec>
<sec sec-type="materials|methods" id="s2">
<title>2 Materials and methods</title>
<sec id="s2-1">
<title>2.1 Reconstruction procedure and characterization of the microfibril patch 3D models</title>
<p>A reliable and fast reconstruction method was fine-tuned to obtain realistic microfibrils&#x2019; patch models, which are characterized by denser or sparser fibrils&#x2019; distribution, organized in a single or a multilayer structure, with homogeneous or heterogeneous diameters and are even characterized by curved and crossed fibrils, in order to represent the scaffold&#x2019;s imperfections due to the manufacturing process or due to the extracellular fluid (ECM or buffer). Then, 3D microfibril CAD models were placed over the electrodes, oriented perpendicular to the conductors, and inside a hosting ECM in order to obtain the complete EPB device model. The microfibril models were reconstructed starting from the images of real PLA microfibril samples. In particular, the samples used consisted of PLA microfiber lanes obtained by grouping PLA microfibers with a diameter of 10&#xa0;&#xb5;m (AITEX, Spain). In order to maintain the alignment of the lane-shaped microfiber bundles, they were heat-sealed together at the samples&#x2019; extremities. The PLA microfiber lane was also heat-sealed to the extremities of a PLA film, where the electrodes will be placed. This PLA film was obtained by the casting technique. First, PLA (1 wt%, Goodfellow, ME34-GL-000110) was dissolved in chloroform (Scharlab S.L., CL02032500) and stirred overnight at room temperature. Then, 120&#xa0;g of the solution was casted into a glass Petri dish with a diameter of 184&#xa0;mm. The solution was air dried for 5 days in order to allow the evaporation of chloroform. Finally, the PLA membrane was dried in a desiccator with fixed vacuum at 40&#xb0;C for 2 days. Cross-section images of the microfibril distribution were obtained by optical microscopy (Nikon ECLIPSE 80i) (see <xref ref-type="sec" rid="s11">Supplementary Figure S1</xref>). The sample was cut at approximately 2&#x2013;3&#xa0;mm from the external boundaries and then placed vertically on an adhesive base; in order to see in the microscope objective, microfibril circular sections were cut with a 10&#xd7; magnitude factor. Further top view images were acquired to investigate a particular microfibril shape, such as curved or crossed microfibrils, within the sample. First, the stereomicroscope (Leica, MZ APO) was employed with low-magnitude factors (10&#xd7; and 20&#xd7;) to have an overview of the sample spatial distribution, which generally is more compact and straight at the extremities (near the sealing) than in the center. In the scaffold&#x2019;s central part, the fibers are freer to move, curve, or cross than in a more peripheric one, where they are more straight and sorted because of the tension applied at the substrate junction. Finally, scanning electron microscopy (SEM, Zeiss, AURIGA Compact) was applied to investigate the samples&#x2019; imperfections and singularity deeply. Such a technique allows us to acquire images with a high level of accuracy and magnitude factors higher than a stereomicroscope (100&#xd7;, 150&#xd7;, 250&#xd7;, and 500&#xd7;) to focus on interesting details. Some of the images are reported in the <xref ref-type="sec" rid="s11">Supplementary Figure S1</xref>.</p>
<p>Thus, starting from the collected images, the reconstruction procedure can be briefly described as follows:<list list-type="simple">
<list-item>
<p>&#x2022; The microfibrils&#x2019; cross-section microscopy images are imported in commercial software AutoCAD2023<xref ref-type="fn" rid="fn2">
<sup>2</sup>
</xref>.</p>
</list-item>
<list-item>
<p>&#x2022; Then, microfibrils&#x2019; circular sections are built through octagons in AutoCAD, which are preferred to circular sections for computational issues (<xref ref-type="bibr" rid="B37">Paffi et al., 2007</xref>), in order to reproduce the realistic spatial distribution of the lane. In this step, it is possible to create octagons with the same dimensions or modulate them as a function of the variable cross sections shown in the microscopy images.</p>
</list-item>
<list-item>
<p>&#x2022; 2D sections are extruded to obtain 3D models that replicate the realistic elongated shape of the fibers, which have a length that is able to cover all the electrodes&#x2019; strips. It is possible to curve or cross one or more fibrils, as those shown in SEM top view images in <xref ref-type="sec" rid="s11">Supplementary Figure S1</xref>.</p>
</list-item>
<list-item>
<p>&#x2022; Finally, all the models built are exported as AutoCAD file.dwg.</p>
</list-item>
</list>
</p>
<p>Following the procedure mentioned previously, the first four built patch models consist of straight, parallel, and homogeneous diameter microfibrils in order to investigate the possible effect on the E-field distribution of the lane density, i.e., characterized by a greater or shorter interfibrillar distance. They are all reported in <xref ref-type="fig" rid="F1">Figure 1</xref> and are defined as a sparse monolayer (model 1) with a height of approximately 25&#xa0;&#x3bc;m that well-reproduces a still sorted and controlled distribution, but which is closer to the center; and a dense monolayer (model 2), characterized by a height of approximately 10&#xa0;&#x3bc;m, which is representative of the distribution near the sealing with PLA. The last two patches are a sparse multilayer (model 3), 50&#xa0;&#xb5;m high, and a dense multilayer (model 4), approximately 40&#xa0;&#xb5;m high, which represents an overlap between the fibers in the sample&#x2019;s central areas. The reference cross-section images are reported in <xref ref-type="sec" rid="s11">Supplementary Figure S2</xref>. Moving toward more realistic models, taking into account the possible variability in each microfibril&#x2019;s diameter, four more models have been considered, in particular, a sparse distribution with a homogeneous (model 5) and heterogeneous radius (model 6), and a dense distribution with a homogeneous (model 7) and heterogeneous radius (model 8). Nonetheless, the diameter heterogeneity could have a maximum variability of 20%, according to <xref ref-type="bibr" rid="B22">Gisbert Roca et al., 2021</xref>. Finally, one or two curved and/or crossed microfibrils in different planes and orientations have been modeled in AutoCAD, as shown in <xref ref-type="fig" rid="F1">Figure 1</xref>, in a 3D view: a curved fibril (models 9 and 11) and two crossed and curved fibrils (model 10 and model 12) on the transversal xy and longitudinal xz planes (along the <italic>z</italic>-axis) have been added, respectively. Such a realistic spatial behavior has been analyzed from SEM images from a top view (<xref ref-type="sec" rid="s11">Supplementary Figure S2</xref>), which shows that it is possible to find one or more not parallel and sorted fibers, due to fabrication imperfections, in the scaffold&#x2019;s center. The replication of abnormal fibrils allows us to perform an even more precise dosimetry.</p>
<fig id="F1" position="float">
<label>FIGURE 1</label>
<caption>
<p>Characterization of different 3D patch models. Straight and parallel microfibril models have been built, considering a sparse and a dense distribution on a single layer or on a multilayer, respectively. Furthermore, other models have been built considering the diameters&#x2019; variability and one or more curved or crossed fibrils.</p>
</caption>
<graphic xlink:href="fbioe-11-1264406-g001.tif"/>
</fig>
</sec>
<sec id="s2-2">
<title>2.2 Fine-tuning of the complete scaffolded electrodes&#x2019; 3D models</title>
<p>As a first step, the electrodes&#x2019; device has been modeled in COMSOL Multiphysics (v. 5.5), involving a block representing the PLA substrate, on which the conductors without thickness (<xref ref-type="fig" rid="F2">Figure 2</xref>) are placed, and an upper block of the extracellular medium. The use of electrodes&#x2019; models without thickness (as shown in Panel A of <xref ref-type="fig" rid="F2">Figure 2</xref>) has been validated through a numerical study using COMSOL, in which a RAM occupation reduction of approximately 6% has been assessed. Such a model (defined as model 0) is the reference electrodes&#x2019; device model, useful in obtaining the nominal E-field without fibers; subsequently, all the microfibrils&#x2019; 3D CAD models, relative to the different scenarios analyzed, are imported in COMSOL Multiphysics, which solves the electro-magnetic problem using the finite element method (FEM) (<xref ref-type="bibr" rid="B28">Jin-Ming, 2015</xref>). In order to further reduce the computational cost, the whole microfibrils&#x2019; sample (with mm dimension) has been divided into smaller patches that are able to reproduce a particular sample area (Panel B of <xref ref-type="fig" rid="F2">Figure 2</xref>), with a lateral dimension W of 381&#xa0;&#xb5;m and a longitudinal dimension D of 500&#xa0;&#xb5;m. Every microfibril&#x2019;s patch includes a couple of active and ground conductors, 100&#xa0;&#xb5;m wide. The full reconstruction process is summarized in <xref ref-type="fig" rid="F3">Figure 3</xref>: octagon creation to reproduce the microfibrils&#x2019; cross section spatial distribution (Panel A), which are then extruded to obtain 3D models (Panel B); the final microfibrils&#x2019; model is imported in COMSOL and placed inside the bare electrodes&#x2019; model in order to finalize the patch of scaffolded electrodes (Panel C). In <xref ref-type="fig" rid="F4">Figure 4</xref>, an example of finalized scaffolded electrodes of model 3 is reported, whereas all the other models are shown in <xref ref-type="sec" rid="s11">Supplementary Figure S3</xref>. The fibers are oriented perpendicularly to the conductors, thus following the E-field lines. Moreover, the E-field distribution obtained for all the models will be compared with the nominal one of the electrodes&#x2019; device model (model 0).</p>
<fig id="F2" position="float">
<label>FIGURE 2</label>
<caption>
<p>Rationale of the microfibrils&#x2019; patch building. <bold>(A)</bold> The electrodes&#x2019; technology involves utilizing alternating active and ground planar and interdigitated golden tracks electrodes. <bold>(B)</bold> A couple of electrodes is placed between a PLA substrate and an extracellular medium (ECM), on which continuity periodic conditions are applied to replicate the solution. The microfibrils&#x2019; lane is then added on the electrodes&#x2019; surface. Each patch is representative of a specific region inside the whole device, for instance in the centre or at the substrate junction.</p>
</caption>
<graphic xlink:href="fbioe-11-1264406-g002.tif"/>
</fig>
<fig id="F3" position="float">
<label>FIGURE 3</label>
<caption>
<p>Workflow of the 3D microfibril reconstruction procedure and modeling of the final scaffolded electrodes. <bold>(A)</bold> Step 1: creation of the microfibril octagonal 2D cross section using AutoCAD, starting from optical microscopy images. <bold>(B)</bold> Step 2: extrusion of the cross sections to obtain the final microfibril 3D CAD models. <bold>(C)</bold> Step 3: the import of the built models using Multiphysics software, where the fibers will be scaled and moved to finalize the complete scaffolded electrode model.</p>
</caption>
<graphic xlink:href="fbioe-11-1264406-g003.tif"/>
</fig>
<fig id="F4" position="float">
<label>FIGURE 4</label>
<caption>
<p>Electrodes&#x2019; model placed between the PLA substrate and the ECM volume without a microfibril layer (model 0, Panel <bold>A</bold>) and an example of microfibril positioning inside the electrodes&#x2019; device (Panel <bold>B</bold>), on a 3D view and on the cross-sectional zy plane view. The finalized microfibril patch models built are reported in <xref ref-type="sec" rid="s11">Supplementary Figure S3</xref>.</p>
</caption>
<graphic xlink:href="fbioe-11-1264406-g004.tif"/>
</fig>
<p>The simulative procedure has been finally setup assigning the electrical properties of the materials, which are selected from the software library for golden electrodes and from the literature for ECM (<xref ref-type="bibr" rid="B16">De Angelis et al., 2020</xref>). The assigned microfibril dielectric properties were experimentally measured, and they consist of an electrical conductivity of <inline-formula id="inf1">
<mml:math id="m1">
<mml:mrow>
<mml:mi mathvariant="normal">&#x3c3;</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>4.25</mml:mn>
<mml:mo>&#x2219;</mml:mo>
<mml:msup>
<mml:mn>10</mml:mn>
<mml:mrow>
<mml:mo>&#x2212;</mml:mo>
<mml:mn>11</mml:mn>
</mml:mrow>
</mml:msup>
</mml:mrow>
</mml:math>
</inline-formula> S/m and a relative permittivity of <inline-formula id="inf2">
<mml:math id="m2">
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="normal">&#x3b5;</mml:mi>
<mml:mi>r</mml:mi>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>6.75</mml:mn>
<mml:mo>&#x2b;</mml:mo>
<mml:mi mathvariant="normal">j</mml:mi>
<mml:mo>&#x2219;</mml:mo>
<mml:mn>0.038</mml:mn>
</mml:mrow>
</mml:math>
</inline-formula>. The mesh building rationale aims at optimizing the computational cost and involves dividing the buffer volume in two equal parts: the first part is the volume just over the electrodes (100&#xa0;&#xb5;m high), in which a custom mesh is set to compute the solution more accurately in the region where the cells are supposed to be exposed; however, in the upper volume of the buffer (100&#xa0;&#xb5;m high), a rougher mesh is applied. Moreover, the microfibrils have been discretized through an <italic>ad hoc</italic> customized mesh, to guarantee an accurate solution and, at the same time, to avoid exacerbating the computational cost. The physics used is the electric current (ec), with a monopolar pulsed signal of &#x2b;10&#xa0;V intensity applied on the active conductor with a duration of 100&#xa0;&#xb5;s and a voltage of 0&#xa0;V on the ground conductor. Finally, all the results have been post-processed using MATLAB (v. 2021B).</p>
</sec>
</sec>
<sec sec-type="results" id="s3">
<title>3 Results</title>
<p>In the following section, the main results of the numerical simulations are reported. Several distribution parameters have been analyzed, to determine whether they affect the electrical performances of the electrodes&#x2019; device and, consequently, the exposure of cells. The influence of the microfibrils&#x2019; scaffold density on the E-field distribution is the first parameter of interest, which is possible to examine considering the sample patches characterized by parallel and straight microfibril models (models 1&#x2013;4), as defined in the previous section. Panel A of <xref ref-type="fig" rid="F5">Figure 5</xref> shows a 3D view of multislice maps on the three coordinated axes in model 0, to have an overview of the nominal E-field distribution in a range between 0&#xa0;kV/m and 100&#xa0;kV/m. The nominal E-field is higher at the conductors&#x2019; edges and then decreases in the gap between the active and the ground conductors but also moving away from the conductors&#x2019; plane (z &#x3d; 0&#xa0;&#xb5;m) along the <italic>z</italic>-axis. The reference results of model 0 are compared with those of the microfibrils&#x2019; patch models on the active electrode&#x2019;s edge on the zy axis (Panel B), in which the field inside the fibers is not considered. Here, it is possible to observe that the E-field values induced in the microfibrils&#x2019; models, as expected, are slightly lower over the microfibril lane than that in model 0. Thus, the microfibrils&#x2019; layer partly shields the E-field, but at the same time, focuses the field in the space between the fibers, bringing it up in the buffer. In relation to the different microfibrils&#x2019; density in the analyzed sample&#x2019;s parts, such an effect is especially emphasized in the sparser regions, where the distance between the fibrils guides the focalization of the field streamlines, allowing the E-field to reach values of up to 100&#xa0;kV/m.</p>
<fig id="F5" position="float">
<label>FIGURE 5</label>
<caption>
<p>Electric field maps: <bold>(A)</bold> an overview of the E-field distribution in model 0 through a multislice representation on the three coordinated axes; <bold>(B)</bold> E-field distribution comparison between all the models considering the slice zy at the active electrode&#x2019;s edge; <bold>(C)</bold> E-field maps and field arrows on the zx plane in slices inside the space between the fibrils, to highlight the E-field bridging effect.</p>
</caption>
<graphic xlink:href="fbioe-11-1264406-g005.tif"/>
</fig>
<p>These considerations are further confirmed through the results on the zx planes taken in the space between the fibers (Panel C), on which the E-field arrows are reported (a focus of the aforementioned maps is reported in the <xref ref-type="sec" rid="s11">Supplementary Figure S4, S5</xref>, for zy and zx planes). The presence of the fibrils plays an important role in the redistribution of the E-field. In microfibrils&#x2019; models, the E-field values over the strips of the electrodes, which are a minimum of 100&#xa0;kV/m, are higher than that in model 0, on which there is a value of approximately 60&#xa0;kV/m. Moreover, it is possible to highlight the E-field &#x201c;bridge effect,&#x201d; especially inside the multilayer models 3 and 4, where E-field values of approximately 65&#xa0;kV/m and 80&#xa0;kV/m are reached in quotes at which an intensity of 45&#xa0;kV/m is registered in model 0, respectively. The arrows over such maps represent the E-field line direction, and their length is proportional to the E-field intensity, which confirms what was stated previously. A further important consideration is related to the results of the dense monolayer (model 2), which is the model with the most evident reduction of E-field values over the microfibrils&#x2019; layer since the fibrils are close to each other, shielding the E-field and reducing the focalization effect. Finally, in <xref ref-type="fig" rid="F6">Figure 6</xref>, we reported the E-field maps on the transversal xy plane, at different heights from the electrodes&#x2019; plane (z &#x3d; 0&#xa0;&#xb5;m). In the following maps, the microfibrils are hidden from E-field map visualization and they are represented, wherever present, as white bands. As expected, the E-field decreases, moving away from the electrodes&#x2019; plane, and higher E-field values are reached in the interfibrillar space and a major decrease is present in the dense monolayer over the <italic>z</italic>-axis, which is well-shown at z &#x3d; 50&#xa0;&#xb5;m. Furthermore, some areas with fiber-like shapes characterized by reduced E-field values (in a range between 10&#xa0;kV/m and 20&#xa0;kV/m, represented in dark blue and blue) are present just above the fibers, as a consequence of the PLA insulating behavior. The aforementioned results have been further investigated, carrying out a quantitative analysis, reported in <xref ref-type="fig" rid="F7">Figure 7</xref>, through E-field boxplots in three different buffer regions (represented from the lightest to the darkest pink shades in <xref ref-type="sec" rid="s11">Supplementary Figure S6</xref>): the bottom volume V<sub>bottom</sub> represents the first 30&#xa0;&#xb5;m above the conductors&#x2019; plane (i.e., where the cells will be hosted), the second one is the medium volume V<sub>middle</sub> (from 30&#xa0;&#x3bc;m to 60&#xa0;&#xb5;m), and the third is the higher or top volume V<sub>top</sub> (from 60&#xa0;&#x3bc;m to 100&#xa0;&#xb5;m). Notably, the results in V<sub>bottom</sub>, and the E-field median values of models 3 and 4 are in line with the nominal one (respectively equal to 66.6&#xa0;kV/m, 64.0&#xa0;kV/m, and 62.6&#xa0;kV/m), as reported in <xref ref-type="table" rid="T1">Table 1</xref> (25th and the 75th percentiles are reported in <xref ref-type="sec" rid="s11">Supplementary Table S1</xref>), whereas the model 1 median value has undergone an E-field median value reduction, which is equal to 51.9&#xa0;kV/m in comparison with the nominal 66.6&#xa0;kV/m. As expected, the dense monolayer is characterized by the lower E-field median value, of 35.2&#xa0;kV/m, a 25th percentile of 31.4&#xa0;kV/m, and a 75th percentile of 44.1&#xa0;kV/m. As a whole, the boxplots of models 1, 3, and 4 are more dispersed than the boxplot of the model 0, which means more variability of the E-field values. Notably, for the boxplot of V<sub>middle</sub> and V<sub>top</sub>, it is possible to highlight that the E-field values induced in the sparser models (model 1 and model 3) are slightly higher than those of the denser models (models 2 and 4), confirming that the denser distributions experience a greater E-field reduction at higher quotes. This consideration is also confirmed in <xref ref-type="sec" rid="s11">Supplementary Figure S7</xref>, in which the E-field histograms of models from 0 to 4 in the buffer volume from 100&#xa0;&#x3bc;m to 200&#xa0;&#xb5;m are reported.</p>
<fig id="F6" position="float">
<label>FIGURE 6</label>
<caption>
<p>Electric field maps on the xy plane at different heights. The E-field values decrease moving away from the plane of the electrodes (z &#x3d; 0&#xa0;&#xb5;m); moreover, the E-field is focalized in interfibrillar spaces, where the E-field reaches higher values than the nominal one.</p>
</caption>
<graphic xlink:href="fbioe-11-1264406-g006.tif"/>
</fig>
<fig id="F7" position="float">
<label>FIGURE 7</label>
<caption>
<p>Electric field boxplots from model 1 to model 4, compared with the electrodes&#x2019; model (model 0), in three different buffer volumes: in the first 30&#xa0;&#xb5;m over the electrodes (0&#xa0;&#xb5;m), from 30&#xa0;&#xb5;m to 60&#xa0;&#x3bc;m, and from 60&#xa0;&#x3bc;m to 100&#xa0;&#xb5;m.</p>
</caption>
<graphic xlink:href="fbioe-11-1264406-g007.tif"/>
</fig>
<table-wrap id="T1" position="float">
<label>TABLE 1</label>
<caption>
<p>Electric field median value of the boxplots reported in <xref ref-type="fig" rid="F7">Figures 7</xref>&#x2013;<xref ref-type="fig" rid="F9">9</xref>.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th rowspan="2" align="center">Model</th>
<th colspan="3" align="center">E-field [kV/m]</th>
</tr>
<tr>
<td align="center">Bottom</td>
<td align="center">Middle</td>
<td align="center">Top</td>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="center">0</td>
<td align="center">66.6</td>
<td align="center">43.1</td>
<td align="center">24.3</td>
</tr>
<tr>
<td align="center">1</td>
<td align="center">51.9</td>
<td align="center">32.5</td>
<td align="center">18.4</td>
</tr>
<tr>
<td align="center">
<italic>2</italic>
</td>
<td align="center">35.2</td>
<td align="center">23.0</td>
<td align="center">13.0</td>
</tr>
<tr>
<td align="center">
<italic>3</italic>
</td>
<td align="center">64.0</td>
<td align="center">33.8</td>
<td align="center">18.9</td>
</tr>
<tr>
<td align="center">
<italic>4</italic>
</td>
<td align="center">62.6</td>
<td align="center">31.0</td>
<td align="center">17.6</td>
</tr>
<tr>
<td align="center">
<italic>5</italic>
</td>
<td align="center">59.3</td>
<td align="center">33.9</td>
<td align="center">18.9</td>
</tr>
<tr>
<td align="center">
<italic>6</italic>
</td>
<td align="center">61.0</td>
<td align="center">35.5</td>
<td align="center">19.9</td>
</tr>
<tr>
<td align="center">7</td>
<td align="center">63.6</td>
<td align="center">30.1</td>
<td align="center">14.1</td>
</tr>
<tr>
<td align="center">
<italic>8</italic>
</td>
<td align="center">66.1</td>
<td align="center">32.3</td>
<td align="center">15.7</td>
</tr>
<tr>
<td align="center">
<italic>9</italic>
</td>
<td align="center">69.3</td>
<td align="center">36.3</td>
<td align="center">19.6</td>
</tr>
<tr>
<td align="center">10</td>
<td align="center">69.9</td>
<td align="center">38.0</td>
<td align="center">19.9</td>
</tr>
<tr>
<td align="center">11</td>
<td align="center">65.1</td>
<td align="center">34.8</td>
<td align="center">19.3</td>
</tr>
<tr>
<td align="center">12</td>
<td align="center">64.7</td>
<td align="center">34.8</td>
<td align="center">19.2</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>The second issue investigated is the role of microfibrils&#x2019; diameter heterogeneity on the overall E-field distribution inside EPB. For this analysis, we refer to the introduced models from model 5 to model 8 in a sparser and a denser microfibril arrangement, respectively. A focus on the E-field distribution on the zy axis at the electrodes&#x2019; edge (<xref ref-type="fig" rid="F8">Figure 8</xref>; Panel A) in patches with heterogeneous diameters is in line with those of homogeneous diameters. These results are confirmed with the boxplots of E-field values in the three buffer volumes (<xref ref-type="fig" rid="F8">Figure 8</xref>; Panel B) (the median values are reported in <xref ref-type="table" rid="T1">Table 1</xref>). The heterogeneous microfibril patch E-field median, 25th percentile, and 75th percentile values are slightly higher than the homogeneous microfibril patch in V<sub>bottom</sub>, V<sub>middle</sub>, and V<sub>top</sub>. Even if the distribution is denser, the presence of some fibers with a lower radius increases the interfibrillar distance in comparison with the homogeneous patch, favoring the bridge effect and allowing the E-field to pass. For instance, it is possible to highlight that for heterogeneous sparse patches, the E-field median in V<sub>bottom</sub>, V<sub>middle</sub>, and V<sub>top</sub> increases to approximately 2.9%, 4.7%, and 5.3%, respectively, with respect to the homogeneous patches.</p>
<fig id="F8" position="float">
<label>FIGURE 8</label>
<caption>
<p>Panel <bold>(A)</bold>: electric field maps for the sparse and dense distribution models with variable diameters, compared with the same distribution but with homogeneous diameters, at the active electrode&#x2019;s edge on the zy plane. <bold>(B)</bold> Electric field boxplot of the four variable diameter models compared with model 0 in the three buffer regions (bottom, middle, and top).</p>
</caption>
<graphic xlink:href="fbioe-11-1264406-g008.tif"/>
</fig>
<p>Finally, concerning models 9 to 12, from maps in Panel A of <xref ref-type="fig" rid="F9">Figure 9</xref> on the active electrode&#x2019;s edge, it is possible to see how the E-field distribution changes, as expected, in relation to the inclination and shape of the fibers, indicated with a black arrow. The curvature of the fiber guides E-field focalization and the bridging effect, varying the interfibrillar distance and the height of the layer. Taking into account the boxplots (Panel B), it is possible to affirm that the global statistical analysis shows analog E-field distributions between fiber patch models in the buffer&#x2019;s volumes of interest. With respect to the nominal field (model 0), in V<sub>bottom</sub>, the E-field median value (<xref ref-type="table" rid="T1">Table 1</xref>) of models 9 and 10 increases to approximately 4.1% and 5%, respectively, whereas for models 11 and 12, there is a slight decrease of 2.3% and 2.9%, respectively.</p>
<fig id="F9" position="float">
<label>FIGURE 9</label>
<caption>
<p>
<bold>(A)</bold> Electric field maps for curved and crossed fibrils on a slice at the active electrode&#x2019;s edge on the zy plane. <bold>(B)</bold> Electric field boxplot of the four models with curved and crossed fibrils compared with model 0, provided for three different buffer volumes.</p>
</caption>
<graphic xlink:href="fbioe-11-1264406-g009.tif"/>
</fig>
</sec>
<sec sec-type="discussion" id="s4">
<title>4 Discussion</title>
<p>In the last few decades, biocompatible scaffolds have been increasingly employed in the field of tissue engineering, particularly for nerve regeneration purposes. In several published works, PLA aligned microfibrils&#x2019; structures have been demonstrated not only to be able to create a stable environment to facilitate the cell&#x2019;s survival but they are also able to promote axonal regeneration in order to create a cell bridge on the lesion and heal the damaged tissue. Although PLA has many advantages, it has an insulating behavior that could be incompatible with the scaffold&#x2019;s electric functionalization, which is increasingly employed to accelerate the cells&#x2019; growth and differentiation processes. For this reason, in this paper, a numerical study on the electric stimulation, provided by planar interdigitated conductors on a PLA substrate, in a microfibrils&#x2019; scaffold has been proposed to prove that PLA&#x2019;s insulating nature does not prevent electric stimulation. For such purposes, a realistic microfibrils&#x2019; lane, a dimension of cm order, has been sampled for computational issues in smaller patches, hundreds of &#xb5;m dimensions, representing the fibers&#x2019; spatial behavior in specific regions of the scaffold. Even though the preferred spatial lane configuration provides a sorted and dense monolayer composed of parallel and non-overlapped fibers, it is unavoidable to find modified fibrils, curved, crossed, or agglomerated in two or three layers due to the manufacturing process or in the extracellular fluid presence, especially in the sample&#x2019;s center. Such realistic distributions have been considered and modeled in 12 different microfibrils&#x2019; patches, to obtain a complete analysis of the E-field induced in the scaffolded electrodes in comparison with the nominal field induced in the electrodes&#x2019; device without fibers (model 0). Microfibrils&#x2019; spatial density, diameters&#x2019; heterogeneity, and abnormal shapes (such as curvatures and crossings) are the three main distribution parameters taken into account. From the analysis, the most impacting parameter is the fibers&#x2019; spatial density. The microfibrils&#x2019; presence focuses the field streamlines in the interfibrillar space, allowing the E-field to pass over the lane and to reach values even over 100&#xa0;kV/m. The E-field bridging effect plays a key role in buffer functionalization since it can improve cell stimulation in specific regions that can be even higher than the nominal condition. Thus, in the sparse model 1, such an effect is more facilitated than that in the denser model 2, which is representative of a patch near the sealing with the PLA substrate. Consequently, the E-field distribution in all the microfibrils&#x2019; patch models is more inhomogeneous as it is possible to see in the boxplots reported in <xref ref-type="fig" rid="F7">Figure 7</xref>, and the E-field intensity over the lane decreases faster than that in model 0 because of the insulating nature of the fibers and also because of the focalization effect in the middle of the lane. Moreover, in denser and overlapped samples&#x2019; areas, such as that represented in model 4, in V<sub>bottom</sub> of the buffer, the E-field median value is in line with the nominal field value (66.6&#xa0;kV/m); however, moving away along the <italic>z</italic>-axis, it experiences a faster E-field reduction in comparison with the sparser patches. Conversely, taking into account the diameters&#x2019; heterogeneity, which is a potential manufacturing imperfection, it is possible to affirm that such a parameter introduces more space between fibers, favoring the bridging effect and E-field penetration inside the buffer more. Finally, the presence of one or more curved or crossed microfibrils also guides the E-field to follow the shape of the fibers, and it is possible to conclude that they do not dramatically affect the E-field distribution, from boxplots in <xref ref-type="fig" rid="F9">Figure 9</xref>.</p>
<p>As a final consideration on the microfibrils&#x2019; global impact on the E-field distribution, all 12 patches, which have been so far considered singularly through a local analysis, are now pooled together to obtain the averaged E-field values on the whole device in the three buffer regions V<sub>bottom</sub>, V<sub>middle</sub>, and V<sub>top</sub>. These data are compared with model 0 (reported in gray) through a bubble plot representation (<xref ref-type="fig" rid="F10">Figure 10</xref>), where the center of the bubble is the E-field median value and the bubble&#x2019;s area is the E-field standard deviation. In general, it is worth mentioning that the E-field values obtained in the bare electrodes&#x2019; model are in the order of tens of kV/m, as the result of an electric pulse with a 100-&#xb5;s duration application. In <xref ref-type="fig" rid="F10">Figure 10</xref>, it is possible to notice that the nominal E-field median value is higher in the bare electrodes&#x2019; model with respect to the 12 microfibrils&#x2019; patches considered as a whole, which are conversely characterized by bigger bubbles than model 0 (i.e., higher standard deviation) in V<sub>bottom</sub> and V<sub>middle</sub>. However, these interesting results show that in the three buffer regions of the scaffolded electrodes, the E-field is 91.7%, 76.6%, and 73.7% of the nominal one, respectively (<xref ref-type="sec" rid="s11">Supplementary Table S4</xref>). However, the bigger variability of the values is a consequence of E-field redistribution operated by fibrils, in which the bridging effect could be exploited in a possible cell exposure scenario.</p>
<fig id="F10" position="float">
<label>FIGURE 10</label>
<caption>
<p>A comparison between the nominal electric field bubble plot of the electrodes&#x2019; device and the whole microfibril model averaged values. The bubble area represents the E-field standard deviation, whereas the center point is the E-field median value.</p>
</caption>
<graphic xlink:href="fbioe-11-1264406-g010.tif"/>
</fig>
<sec id="s4-1">
<title>4.1 Limitations and future work</title>
<p>This study represents a purely numerical investigation into the electrical performance of a fundamental device within the context of the RISEUP project, specifically pertaining to the foundational design of EPB technology and its subsequent development. The primary objective of this work is to lay the groundwork for the realization of the device, by providing valuable insights into how a microfibril distribution may impact the electric field generated by electrode technology and ensure the desired electric field levels. Consequently, this analysis serves as an essential step toward enhancing the manufacturing process&#x2019;s awareness and efficiency.</p>
<p>Given the inherent challenges in experimentally measuring the electric field produced by this technology, our approach relies on advanced and realistic 3D simulations. These simulations, as proposed here, represent the sole means of determining precise electrical dosages at a microscale level (P. <xref ref-type="bibr" rid="B34">Liu and Miller, 2020</xref>; <xref ref-type="bibr" rid="B3">Bai and Gu, 2016</xref>; <xref ref-type="bibr" rid="B25">Haider et al., 2021</xref>). It is worth noting that, while this study is an integral part of the EPB implementation process, it does not encompass the <italic>in vitro</italic> and <italic>in vivo</italic> validation of its efficacy.</p>
<p>Recognizing the constraints associated with the electrode technology, our investigation focuses on analyzing the absorbed current, estimating values that are in line with the technological limitations. In our future endeavors, we aim to validate the functional efficiency of EPB on the cellular behavior through experimental studies, building upon the key findings discussed in this study. Specifically, both <italic>in vitro</italic> and <italic>in vivo</italic> assays will verify whether cellular stimulation can facilitate tissue regeneration by fostering the creation of a biohybrid cell bridge. This aspect holds pivotal significance in evaluating the technology&#x2019;s potential applications in spinal cord injury treatment.</p>
<p>To provide valuable insights and predictions concerning threshold levels induced by stimulation, we anticipate conducting additional numerical investigations to complement the experimental <italic>in vitro</italic> data. These investigations will serve as a vital resource in further supporting our research efforts.</p>
</sec>
</sec>
<sec sec-type="conclusion" id="s5">
<title>5 Conclusion</title>
<p>In this work, a reconstruction procedure of microfibrils&#x2019; 3D CAD models has been presented, from which a numerical study on the E-field distribution inside an example of scaffolded electrodes has been fine-tuned. From the results shown, it is possible to affirm that this PLA microfibril-based technology, despite its insulating nature, is not only able to support and guide cell growth, but it is also compatible with their electric stimulation, in which approximately 90% of the nominal field is guaranteed in the buffer&#x2019;s volume hosting the cell. Furthermore, the use of the PLA microfibrils&#x2019; scaffold is suitable for the application of high-intensity &#xb5;sPEF stimulation, and in conclusion, it could be exploited within the RISEUP project.</p>
</sec>
</body>
<back>
<sec sec-type="data-availability" id="s6">
<title>Data availability statement</title>
<p>The original contributions presented in the study are included in the article/<xref ref-type="sec" rid="s11">Supplementary Material</xref>; further inquiries can be directed to the corresponding author.</p>
</sec>
<sec id="s7">
<title>Author contributions</title>
<p>SF: writing&#x2013;original draft, writing&#x2013;review and editing, data curation, formal analysis, investigation, methodology, software, and visualization. LC: writing&#x2013;review and editing, data curation, formal analysis, investigation, methodology, software, and visualization. PM: writing&#x2013;review and editing, investigation, and conceptualization. IC, FG, SI, JM, and MB: writing&#x2013;review and editing, and investigation. MC, ND, and AP: writing&#x2013;review and editing, and formal analysis. CC: writing&#x2013;review and editing and project administration. FP and ML: writing&#x2013;review and editing, conceptualization, investigation, methodology, supervision, and software.</p>
</sec>
<sec id="s8">
<title>Funding</title>
<p>The author(s) declare financial support was received for the research, authorship, and/or publication of this article. This work has been developed in the framework of and supported by the FET-OPEN RISEUP project funded by the European Union&#x2019;s Horizon 2020 research and innovation program (grant agreement no. 964562). ICO acknowledges the grant PRE2019-090716 co-funded by MCIN/AEI/10.13039/501100011033 and by &#x201c;ESF Investing in your future&#x201d; for supporting her visiting student stay at Sapienza, University of Rome. FGR acknowledges Vicerrectorado de Investigaci&#x00F3;n de la Universitat Polit&#x00E8;cnica de Val&#x00E8;ncia (PAID-10-22) for co-funding with RISEUP project his fellowship.</p>
</sec>
<sec sec-type="COI-statement" id="s9">
<title>Conflict of interest</title>
<p>Authors PM and MB were employed by RISE Technology S.R.L.</p>
<p>The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
<p>The author(s) declared that they were an editorial board member of Frontiers, at the time of submission. This had no impact on the peer review process and the final decision.</p>
</sec>
<sec sec-type="disclaimer" id="s10">
<title>Publisher&#x2019;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors, and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<sec id="s11">
<title>Supplementary material</title>
<p>The Supplementary Material for this article can be found online at: <ext-link ext-link-type="uri" xlink:href="https://www.frontiersin.org/articles/10.3389/fbioe.2023.1264406/full#supplementary-material">https://www.frontiersin.org/articles/10.3389/fbioe.2023.1264406/full&#x23;supplementary-material</ext-link>
</p>
<supplementary-material xlink:href="Presentation1.pptx" id="SM1" mimetype="application/pptx" xmlns:xlink="http://www.w3.org/1999/xlink"/>
</sec>
<fn-group>
<fn id="fn1">
<label>1</label>
<p>RISEUP, RISEUP (riseup-project.eu).</p>
</fn>
<fn id="fn2">
<label>2</label>
<p>
<ext-link ext-link-type="uri" xlink:href="https://www.autodesk.com/products">https://www.autodesk.com/products</ext-link>.</p>
</fn>
</fn-group>
<ref-list>
<title>References</title>
<ref id="B1">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Angeli</surname>
<given-names>C. A.</given-names>
</name>
<name>
<surname>Boakye</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Morton</surname>
<given-names>R. A.</given-names>
</name>
<name>
<surname>Vogt</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Benton</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>Y.</given-names>
</name>
<etal/>
</person-group> (<year>2018</year>). <article-title>From the frazier rehabilitation institute recovery of over-ground walking after chronic motor complete spinal cord injury</article-title>. <source>N. Engl. J. Med.</source> <volume>379</volume>, <fpage>1244</fpage>&#x2013;<lpage>1250</lpage>. <pub-id pub-id-type="doi">10.1056/NEJMoa1803588</pub-id>
</citation>
</ref>
<ref id="B2">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Angeli</surname>
<given-names>C. A.</given-names>
</name>
<name>
<surname>Reggie Edgerton</surname>
<given-names>V.</given-names>
</name>
<name>
<surname>Gerasimenko</surname>
<given-names>Y. P.</given-names>
</name>
<name>
<surname>Harkema</surname>
<given-names>S. J.</given-names>
</name>
<name>
<surname>Harkema</surname>
<given-names>S.</given-names>
</name>
</person-group> (<year>2015</year>). <article-title>Altering spinal cord excitability enables voluntary movements after chronic complete paralysis in humans</article-title>. <source>A J. NEUROLOGY</source> <volume>137</volume>, <fpage>1394</fpage>&#x2013;<lpage>1409</lpage>. <pub-id pub-id-type="doi">10.1093/brain/awu038</pub-id>
</citation>
</ref>
<ref id="B3">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bai</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Gu</surname>
<given-names>N.</given-names>
</name>
</person-group> (<year>2016</year>). <article-title>Micro/nanoscale thermometry for cellular thermal sensing</article-title>. <source>Small</source> <volume>12</volume> (<issue>34</issue>), <fpage>4590</fpage>&#x2013;<lpage>4610</lpage>. <pub-id pub-id-type="doi">10.1002/SMLL.201600665</pub-id>
</citation>
</ref>
<ref id="B4">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Barbiellini Amidei</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Salmaso</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Bellio</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Saia</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Epidemiology of traumatic spinal cord injury: a large population-based study</article-title>. <source>Spinal Cord.</source> <volume>60</volume> (<issue>9</issue>), <fpage>812</fpage>&#x2013;<lpage>819</lpage>. <pub-id pub-id-type="doi">10.1038/s41393-022-00795-w</pub-id>
</citation>
</ref>
<ref id="B5">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Boni</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Ali</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Shavandi</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Clarkson</surname>
<given-names>A. N.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Current and novel polymeric biomaterials for neural tissue engineering</article-title>. <source>J. Biomed. Sci.</source> <volume>25</volume> (<issue>1</issue>), <fpage>90</fpage>&#x2013;<lpage>21</lpage>. <pub-id pub-id-type="doi">10.1186/s12929-018-0491-8</pub-id>
</citation>
</ref>
<ref id="B6">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Breton</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Mir</surname>
<given-names>L. M.</given-names>
</name>
</person-group> (<year>2012</year>). <article-title>Microsecond and nanosecond electric pulses in cancer treatments</article-title>. <source>Bioelectromagnetics</source> <volume>33</volume> (<issue>2</issue>), <fpage>106</fpage>&#x2013;<lpage>123</lpage>. <pub-id pub-id-type="doi">10.1002/BEM.20692</pub-id>
</citation>
</ref>
<ref id="B7">
<citation citation-type="confproc">
<person-group person-group-type="author">
<name>
<surname>Caramazza</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>De Angelis</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Andre</surname>
<given-names>F. M.</given-names>
</name>
<name>
<surname>Mir</surname>
<given-names>L. M.</given-names>
</name>
<name>
<surname>Apollonio</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Liberti</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2022</year>). &#x201c;<article-title>Dielectric response of biological systems at cellular and subcellular level: a modelling study</article-title>,&#x201d; in <conf-name>Proceedings of the 2022 52nd European Microwave Conference, EuMC</conf-name>, <conf-loc>Milan, Italy</conf-loc>, <conf-date>September 2022</conf-date>, <fpage>820</fpage>&#x2013;<lpage>823</lpage>. <pub-id pub-id-type="doi">10.23919/EuMC54642.2022.9924496</pub-id>
</citation>
</ref>
<ref id="B8">
<citation citation-type="confproc">
<person-group person-group-type="author">
<name>
<surname>Caramazza</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>De Angelis</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Haider</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Zhadobov</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Andre</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Mir</surname>
<given-names>L. M.</given-names>
</name>
<etal/>
</person-group> (<year>2021a</year>). &#x201c;<article-title>A microdosimetric study at the cellular and intracellular level using a 3D realistic cell model</article-title>,&#x201d; in <conf-name>Proceedings of the 2021 51st European Microwave Conference (EuMC)</conf-name>, <conf-loc>London, UK</conf-loc>, <conf-date>April 2022</conf-date>. <pub-id pub-id-type="doi">10.23919/EuMC50147.2022.9784171</pub-id>
</citation>
</ref>
<ref id="B9">
<citation citation-type="confproc">
<person-group person-group-type="author">
<name>
<surname>Caramazza</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>De Angelis</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Remondini</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Castellani</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Liberti</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Apollonio</surname>
<given-names>F.</given-names>
</name>
<etal/>
</person-group> (<year>2020a</year>). &#x201c;<article-title>Galvanotactic phenomenon induced by non-contact electrostatic field: investigation in a scratch assay</article-title>,&#x201d; in <conf-name>Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society</conf-name>, <conf-loc>Montreal, QC, Canada</conf-loc>, <conf-date>July 2020</conf-date>, <fpage>2520</fpage>&#x2013;<lpage>2523</lpage>. <pub-id pub-id-type="doi">10.1109/EMBC44109.2020.9175695</pub-id>
</citation>
</ref>
<ref id="B10">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Caramazza</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Nardoni</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>De Angelis</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Paolicelli</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Liberti</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Apollonio</surname>
<given-names>F.</given-names>
</name>
<etal/>
</person-group> (<year>2020b</year>). <article-title>Proof-of-Concept of electrical activation of liposome nanocarriers: from dry to wet experiments</article-title>. <source>Front. Bioeng. Biotechnol.</source> <volume>8</volume>, <fpage>819</fpage>. <pub-id pub-id-type="doi">10.3389/fbioe.2020.00819</pub-id>
</citation>
</ref>
<ref id="B11">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Caramazza</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Paffi</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Liberti</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Apollonio</surname>
<given-names>F.</given-names>
</name>
</person-group> (<year>2021b</year>). <article-title>Experimental and numerical characterization of a grounded coplanar waveguide for nanoelectroporation applied to liposomes</article-title>. <source>Int. J. Microw. Wirel. Technol.</source> <volume>13</volume> (<issue>7</issue>), <fpage>663</fpage>&#x2013;<lpage>672</lpage>. <pub-id pub-id-type="doi">10.1017/S1759078721000441</pub-id>
</citation>
</ref>
<ref id="B12">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Castells-sala</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Ribes</surname>
<given-names>M. A.</given-names>
</name>
<name>
<surname>Children</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Recha</surname>
<given-names>L.</given-names>
</name>
</person-group> (<year>2015</year>). <article-title>Current applications of tissue engineering in biomedicine</article-title>. <source>J. Biochips Tissue Chips</source>. <pub-id pub-id-type="doi">10.4172/2153-0777.s2-004</pub-id>
</citation>
</ref>
<ref id="B13">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Chow</surname>
<given-names>W. N.</given-names>
</name>
<name>
<surname>Simpson</surname>
<given-names>D. G.</given-names>
</name>
<name>
<surname>Bigbee</surname>
<given-names>J. W.</given-names>
</name>
<name>
<surname>Colello</surname>
<given-names>R. J.</given-names>
</name>
</person-group> (<year>2007</year>). <article-title>Evaluating neuronal and glial growth on electrospun polarized matrices: bridging the gap in percussive spinal cord injuries</article-title>. <source>Neuron Glia Biol.</source> <volume>3</volume> (<issue>2</issue>), <fpage>119</fpage>&#x2013;<lpage>126</lpage>. <pub-id pub-id-type="doi">10.1017/S1740925X07000580</pub-id>
</citation>
</ref>
<ref id="B14">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Corey</surname>
<given-names>J. M.</given-names>
</name>
<name>
<surname>Lin</surname>
<given-names>D. Y.</given-names>
</name>
<name>
<surname>Mycek</surname>
<given-names>K. B.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>Q.</given-names>
</name>
<name>
<surname>Samuel</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Feldman</surname>
<given-names>E. L.</given-names>
</name>
<etal/>
</person-group> (<year>2007</year>). <article-title>Aligned electrospun nanofibers specify the direction of dorsal root ganglia neurite growth</article-title>. <source>J. Biomed. Mater. Res. - Part A</source> <volume>83</volume> (<issue>3</issue>), <fpage>636</fpage>&#x2013;<lpage>645</lpage>. <pub-id pub-id-type="doi">10.1002/JBM.A.31285</pub-id>
</citation>
</ref>
<ref id="B15">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Damianakis</surname>
<given-names>E. I.</given-names>
</name>
<name>
<surname>Benetos</surname>
<given-names>I. S.</given-names>
</name>
<name>
<surname>Evangelopoulos</surname>
<given-names>D. S.</given-names>
</name>
<name>
<surname>Kotroni</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Vlamis</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Pneumaticos</surname>
<given-names>S. G.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Stem cell therapy for spinal cord injury: a review of recent clinical trials</article-title>. <source>Cureus</source> <volume>14</volume> (<issue>4</issue>), <fpage>e24575</fpage>. <pub-id pub-id-type="doi">10.7759/CUREUS.24575</pub-id>
</citation>
</ref>
<ref id="B16">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>De Angelis</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Denzi</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Merla</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Andre</surname>
<given-names>F. M.</given-names>
</name>
<name>
<surname>Mir</surname>
<given-names>L. M.</given-names>
</name>
<name>
<surname>Apollonio</surname>
<given-names>F.</given-names>
</name>
<etal/>
</person-group> (<year>2020</year>). <article-title>Confocal microscopy improves 3D microdosimetry applied to nanoporation experiments targeting endoplasmic reticulum</article-title>. <source>Front. Bioeng. Biotechnol.</source> <volume>8</volume>, <fpage>552261</fpage>. <pub-id pub-id-type="doi">10.3389/fbioe.2020.552261</pub-id>
</citation>
</ref>
<ref id="B17">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Diop</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Diop</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Epstein</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Gaggero</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Cherif</surname>
<given-names>I.</given-names>
</name>
<name>
<surname>Cherif</surname>
<given-names>I.</given-names>
</name>
<etal/>
</person-group> (<year>2021</year>). <article-title>Chronic diseases Quality of life, health and social costs of patients with spinal cord injury: a systematic review</article-title>. <source>Eur. J. Public Health</source> <volume>31</volume>. <pub-id pub-id-type="doi">10.1093/eurpub/ckab165.177</pub-id>
</citation>
</ref>
<ref id="B18">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Dong</surname>
<given-names>Z. Y.</given-names>
</name>
<name>
<surname>Pei</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>Y. L.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Khan</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Meng</surname>
<given-names>X. T.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Ascl1 regulates electric field-induced neuronal differentiation through PI3K/akt pathway</article-title>. <source>Neuroscience</source> <volume>404</volume>, <fpage>141</fpage>&#x2013;<lpage>152</lpage>. <pub-id pub-id-type="doi">10.1016/J.NEUROSCIENCE.2019.02.004</pub-id>
</citation>
</ref>
<ref id="B19">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Dowlati</surname>
<given-names>E.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>Spinal cord anatomy, pain, and spinal cord stimulation mechanisms</article-title>. <source>Seminars Spine Surg.</source> <volume>29</volume> (<issue>3</issue>), <fpage>136</fpage>&#x2013;<lpage>146</lpage>. <pub-id pub-id-type="doi">10.1053/J.SEMSS.2017.05.002</pub-id>
</citation>
</ref>
<ref id="B20">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Famm</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Litt</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Tracey</surname>
<given-names>K. J.</given-names>
</name>
<name>
<surname>Boyden</surname>
<given-names>E. S.</given-names>
</name>
<name>
<surname>Slaoui</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2013</year>). <article-title>A jump-start for electroceuticals</article-title>. <source>Nature</source> <volume>496</volume>, <fpage>159</fpage>&#x2013;<lpage>161</lpage>. <pub-id pub-id-type="doi">10.1038/496159a</pub-id>
</citation>
</ref>
<ref id="B21">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Formento</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Minassian</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Wagner</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Mignardot</surname>
<given-names>J. B.</given-names>
</name>
<name>
<surname>Le Goff-Mignardot</surname>
<given-names>C. G.</given-names>
</name>
<name>
<surname>Rowald</surname>
<given-names>A.</given-names>
</name>
<etal/>
</person-group> (<year>2018</year>). <article-title>Electrical spinal cord stimulation must preserve proprioception to enable locomotion in humans with spinal cord injury</article-title>. <source>Nat. Neurosci.</source> <volume>21</volume> (<issue>12</issue>), <fpage>1728</fpage>&#x2013;<lpage>1741</lpage>. <pub-id pub-id-type="doi">10.1038/S41593-018-0262-6</pub-id>
</citation>
</ref>
<ref id="B22">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Gisbert Roca</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Garc&#xed;a-Bernab&#xe9;</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Compa&#xf1; Moreno</surname>
<given-names>V.</given-names>
</name>
<name>
<surname>Mart&#xed;nez-Ramos</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Monle&#xf3;n Pradas</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Solid polymer electrolytes based on polylactic acid nanofiber mats coated with polypyrrole</article-title>. <source>Macromol. Mater. Eng.</source> <volume>306</volume> (<issue>2</issue>), <fpage>1</fpage>&#x2013;<lpage>14</lpage>. <pub-id pub-id-type="doi">10.1002/mame.202000584</pub-id>
</citation>
</ref>
<ref id="B23">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Gisbert Roca</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>M&#xe1;s Estell&#xe9;s</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Pradas</surname>
<given-names>M. M.</given-names>
</name>
<name>
<surname>Mart&#xed;nez-Ramos</surname>
<given-names>C.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Axonal extension from dorsal root ganglia on fibrillar and highly aligned poly(lactic acid)-polypyrrole substrates obtained by two different techniques: electrospun nanofibres and extruded microfibres</article-title>. <source>Int. J. Biol. Macromol.</source> <volume>163</volume>, <fpage>1959</fpage>&#x2013;<lpage>1969</lpage>. <pub-id pub-id-type="doi">10.1016/j.ijbiomac.2020.09.181</pub-id>
</citation>
</ref>
<ref id="B24">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Gisbert Roca</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Serrano Requena</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Monle&#xf3;n Pradas</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Mart&#xed;nez-Ramos</surname>
<given-names>C.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Electrical stimulation increases axonal growth from dorsal root ganglia Co-cultured with Schwann cells in highly aligned PLA-PPy-Au microfiber substrates</article-title>. <source>Int. J. Mol. Sci.</source> <volume>23</volume> (<issue>12</issue>), <fpage>6362</fpage>. <pub-id pub-id-type="doi">10.3390/ijms23126362</pub-id>
</citation>
</ref>
<ref id="B25">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Haider</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Nikolayev</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Le Drean</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>De Angelis</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Liberti</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Sauleau</surname>
<given-names>R.</given-names>
</name>
<etal/>
</person-group> (<year>2021</year>). <article-title>Local dosimetry at cellular and subcellular level in HF and millimeter-wave bands</article-title>. <source>IEEE J. Microwaves</source> <volume>1</volume> (<issue>4</issue>), <fpage>1003</fpage>&#x2013;<lpage>1014</lpage>. <pub-id pub-id-type="doi">10.1109/jmw.2021.3111965</pub-id>
</citation>
</ref>
<ref id="B26">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>James</surname>
<given-names>N. D.</given-names>
</name>
<name>
<surname>McMahon</surname>
<given-names>S. B.</given-names>
</name>
<name>
<surname>Field-Fote</surname>
<given-names>E. C.</given-names>
</name>
<name>
<surname>Bradbury</surname>
<given-names>E. J.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Neuromodulation in the restoration of function after spinal cord injury</article-title>. <source>Lancet Neurology</source> <volume>17</volume> (<issue>10</issue>), <fpage>905</fpage>&#x2013;<lpage>917</lpage>. <pub-id pub-id-type="doi">10.1016/S1474-4422(18)30287-4</pub-id>
</citation>
</ref>
<ref id="B27">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Janou&#x161;kov&#xe1;</surname>
<given-names>O.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Synthetic polymer scaffolds for soft tissue engineering</article-title>. <source>Physiological Res.</source> <volume>67</volume>, <fpage>S335</fpage>&#x2013;<lpage>s348</lpage>. <pub-id pub-id-type="doi">10.33549/physiolres.933983</pub-id>
</citation>
</ref>
<ref id="B28">
<citation citation-type="web">
<person-group person-group-type="author">
<name>
<surname>Jin-Ming</surname>
<given-names>J.</given-names>
</name>
</person-group> (<year>2015</year>). <article-title>The finite element method in electromagnetics</article-title>. <comment>Available at: <ext-link ext-link-type="uri" xlink:href="https://books.google.com/books/about/The_Finite_Element_Method_in_Electromagn.html?hl=it&amp;id=DFi-BgAAQBAJ">https://books.google.com/books/about/The_Finite_Element_Method_in_Electromagn.html?hl&#x3d;it&#x26;id&#x3d;DFi-BgAAQBAJ</ext-link> (Accessed July 19, 2023)</comment>.</citation>
</ref>
<ref id="B29">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kotnik</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Rems</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Tarek</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Miklav&#x10d;i&#x10d;</surname>
<given-names>D.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Membrane electroporation and electropermeabilization: mechanisms and models</article-title>. <source>Annu. Rev. Biophysics</source> <volume>48</volume>, <fpage>63</fpage>&#x2013;<lpage>91</lpage>. <pub-id pub-id-type="doi">10.1146/annurev-biophys-052118-115451</pub-id>
</citation>
</ref>
<ref id="B30">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kumamaru</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Lu</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Rosenzweig</surname>
<given-names>E. S.</given-names>
</name>
<name>
<surname>Kadoya</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Tuszynski</surname>
<given-names>M. H.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Regenerating corticospinal axons innervate phenotypically appropriate neurons within neural stem cell grafts</article-title>. <source>Cell Rep.</source> <volume>26</volume> (<issue>9</issue>), <fpage>2329</fpage>&#x2013;<lpage>2339.e4</lpage>. <pub-id pub-id-type="doi">10.1016/J.CELREP.2019.01.099</pub-id>
</citation>
</ref>
<ref id="B31">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Langer</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Vacanti</surname>
<given-names>J.</given-names>
</name>
</person-group> (<year>2016</year>). <article-title>Advances in tissue engineering</article-title>. <source>J. Pediatr. Surg.</source> <volume>51</volume> (<issue>1</issue>), <fpage>8</fpage>&#x2013;<lpage>12</lpage>. <pub-id pub-id-type="doi">10.1016/j.jpedsurg.2015.10.022</pub-id>
</citation>
</ref>
<ref id="B32">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lee</surname>
<given-names>J. Y.</given-names>
</name>
<name>
<surname>Bashur</surname>
<given-names>C. A.</given-names>
</name>
<name>
<surname>Goldstein</surname>
<given-names>A. S.</given-names>
</name>
<name>
<surname>Schmidt</surname>
<given-names>C. E.</given-names>
</name>
</person-group> (<year>2009</year>). <article-title>Polypyrrole-coated electrospun PLGA nanofibers for neural tissue applications</article-title>. <source>Biomaterials</source> <volume>30</volume> (<issue>26</issue>), <fpage>4325</fpage>&#x2013;<lpage>4335</lpage>. <pub-id pub-id-type="doi">10.1016/j.biomaterials.2009.04.042</pub-id>
</citation>
</ref>
<ref id="B33">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Liu</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Lv</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Zhu</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Wu</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Xu</surname>
<given-names>F.</given-names>
</name>
<etal/>
</person-group> (<year>2017</year>). <article-title>Salidroside promotes peripheral nerve regeneration based on tissue engineering strategy using Schwann cells and PLGA: <italic>in vitro</italic> and <italic>in vivo</italic>
</article-title>. <source>Sci. Rep.</source> <volume>7</volume>, <fpage>39869</fpage>&#x2013;<lpage>39911</lpage>. <pub-id pub-id-type="doi">10.1038/srep39869</pub-id>
</citation>
</ref>
<ref id="B34">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Liu</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Miller</surname>
<given-names>E. W.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Electrophysiology, unplugged: imaging membrane potential with fluorescent indicators</article-title>. <source>Accounts Chem. Res.</source> <volume>53</volume> (<issue>1</issue>), <fpage>11</fpage>&#x2013;<lpage>19</lpage>. <pub-id pub-id-type="doi">10.1021/acs.accounts.9b00514</pub-id>
</citation>
</ref>
<ref id="B35">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Marracino</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Caramazza</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Montagna</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Ghahri</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>D&#x2019;abramo</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Liberti</surname>
<given-names>M.</given-names>
</name>
<etal/>
</person-group> (<year>2021</year>). <article-title>Electric-driven membrane poration: a rationale for water role in the kinetics of pore formation</article-title>. <source>Bioelectrochemistry</source> <volume>143</volume>, <fpage>107987</fpage>. <pub-id pub-id-type="doi">10.1016/j.bioelechem.2021.107987</pub-id>
</citation>
</ref>
<ref id="B36">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Naskar</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Kumaran</surname>
<given-names>V.</given-names>
</name>
<name>
<surname>Markandeya</surname>
<given-names>Y. S.</given-names>
</name>
<name>
<surname>Mehta</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Basu</surname>
<given-names>B.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Neurogenesis-on-Chip: electric field modulated transdifferentiation of human mesenchymal stem cell and mouse muscle precursor cell coculture</article-title>. <source>Biomaterials</source> <volume>226</volume>, <fpage>119522</fpage>. <pub-id pub-id-type="doi">10.1016/j.biomaterials.2019.119522</pub-id>
</citation>
</ref>
<ref id="B37">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Paffi</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Pellegrino</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Beccherelli</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Apollonio</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Liberti</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Platano</surname>
<given-names>D.</given-names>
</name>
<etal/>
</person-group> (<year>2007</year>). <article-title>A real-time exposure system for electrophysiological recording in brain slices</article-title>. <source>IEEE Trans. Microw. Theory Tech.</source> <volume>55</volume> (<issue>11</issue>), <fpage>2463</fpage>&#x2013;<lpage>2471</lpage>. <pub-id pub-id-type="doi">10.1109/TMTT.2007.908657</pub-id>
</citation>
</ref>
<ref id="B38">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ramos</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Moroni</surname>
<given-names>L.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Tissue engineering and regenerative medicine 2019: the role of biofabrication - a year in review</article-title>. <source>Tissue Eng. - Part C. Methods</source> <volume>26</volume> (<issue>2</issue>), <fpage>91</fpage>&#x2013;<lpage>106</lpage>. <pub-id pub-id-type="doi">10.1089/ten.tec.2019.0344</pub-id>
</citation>
</ref>
<ref id="B39">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Rowald</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Komi</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Demesmaeker</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Baaklini</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Hernandez-Charpak</surname>
<given-names>S. D.</given-names>
</name>
<name>
<surname>Paoles</surname>
<given-names>E.</given-names>
</name>
<etal/>
</person-group> (<year>2022</year>). <article-title>Activity-dependent spinal cord neuromodulation rapidly restores trunk and leg motor functions after complete paralysis</article-title>. <source>Nat. Med.</source> <volume>28</volume> (<issue>2</issue>), <fpage>260</fpage>&#x2013;<lpage>271</lpage>. <pub-id pub-id-type="doi">10.1038/S41591-021-01663-5</pub-id>
</citation>
</ref>
<ref id="B40">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Schmidt</surname>
<given-names>C. E.</given-names>
</name>
<name>
<surname>Leach</surname>
<given-names>J. B.</given-names>
</name>
</person-group> (<year>2003</year>). <article-title>Neural tissue engineering: strategies for repair and regeneration</article-title>. <source>Annu. Rev. Biomed. Eng.</source> <volume>5</volume>, <fpage>293</fpage>&#x2013;<lpage>347</lpage>. <pub-id pub-id-type="doi">10.1146/annurev.bioeng.5.011303.120731</pub-id>
</citation>
</ref>
<ref id="B41">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Schnell</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Klinkhammer</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Balzer</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Brook</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Klee</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Dalton</surname>
<given-names>P.</given-names>
</name>
<etal/>
</person-group> (<year>2007</year>). <article-title>Guidance of glial cell migration and axonal growth on electrospun nanofibers of poly-&#x3b5;-caprolactone and a collagen/poly-&#x3b5;-caprolactone blend</article-title>. <source>Biomaterials</source> <volume>28</volume> (<issue>19</issue>), <fpage>3012</fpage>&#x2013;<lpage>3025</lpage>. <pub-id pub-id-type="doi">10.1016/j.biomaterials.2007.03.009</pub-id>
</citation>
</ref>
<ref id="B42">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wagner</surname>
<given-names>F. B.</given-names>
</name>
<name>
<surname>Mignardot</surname>
<given-names>J. B.</given-names>
</name>
<name>
<surname>Le Goff-Mignardot</surname>
<given-names>C. G.</given-names>
</name>
<name>
<surname>Demesmaeker</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Komi</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Capogrosso</surname>
<given-names>M.</given-names>
</name>
<etal/>
</person-group> (<year>2018</year>). <article-title>Targeted neurotechnology restores walking in humans with spinal cord injury</article-title>. <source>Nature</source> <volume>563</volume> (<issue>7729</issue>), <fpage>65</fpage>&#x2013;<lpage>71</lpage>. <pub-id pub-id-type="doi">10.1038/s41586-018-0649-2</pub-id>
</citation>
</ref>
<ref id="B43">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wan</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Liu</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Lv</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Zhou</surname>
<given-names>Y.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Four-dimensional bioprinting: current developments and applications in bone tissue engineering</article-title>. <source>Acta Biomater.</source> <volume>101</volume>, <fpage>26</fpage>&#x2013;<lpage>42</lpage>. <pub-id pub-id-type="doi">10.1016/j.actbio.2019.10.038</pub-id>
</citation>
</ref>
<ref id="B44">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wang</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Tan</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Hui</surname>
<given-names>X.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Biomaterial scaffolds in regenerative therapy of the central nervous system</article-title>. <source>BioMed Res. Int.</source> <volume>2018</volume>, <fpage>1</fpage>&#x2013;<lpage>19</lpage>. <pub-id pub-id-type="doi">10.1155/2018/7848901</pub-id>
</citation>
</ref>
<ref id="B45">
<citation citation-type="book">
<collab>World Health Organization</collab> (<year>2007</year>). <source>Neurological disorders affect milions globally: WHO report</source>.</citation>
</ref>
<ref id="B46">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Xie</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Macewan</surname>
<given-names>M. ] R.</given-names>
</name>
<name>
<surname>Willerth</surname>
<given-names>S. M.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Moran</surname>
<given-names>D. W.</given-names>
</name>
<name>
<surname>Sakiyama-Elbert</surname>
<given-names>S. E.</given-names>
</name>
<etal/>
</person-group> (<year>2009</year>). <article-title>Conductive core-sheath nanofibers and their potential application in neural tissue engineering</article-title>. <source>Adv. Funct. Mater.</source> <volume>19</volume>, <fpage>2312</fpage>&#x2013;<lpage>2318</lpage>. <pub-id pub-id-type="doi">10.1002/adfm.200801904</pub-id>
</citation>
</ref>
<ref id="B47">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Xu</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Huang</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Pu</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Yin</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>J.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Fabrication of Chitosan/Polypyrrole-coated poly(L-lactic acid)/Polycaprolactone aligned fibre films for enhancement of neural cell compatibility and neurite growth</article-title>. <source>Cell Prolif.</source> <volume>52</volume> (<issue>3</issue>), <fpage>e12588</fpage>. <pub-id pub-id-type="doi">10.1111/CPR.12588</pub-id>
</citation>
</ref>
<ref id="B48">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yang</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Murugan</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Ramakrishna</surname>
<given-names>S.</given-names>
</name>
</person-group> (<year>2005</year>). <article-title>Electrospinning of nano/micro scale poly(l-lactic acid) aligned fibers and their potential in neural tissue engineering</article-title>. <source>Biomaterials</source> <volume>26</volume> (<issue>15</issue>), <fpage>2603</fpage>&#x2013;<lpage>2610</lpage>. <pub-id pub-id-type="doi">10.1016/J.BIOMATERIALS.2004.06.051</pub-id>
</citation>
</ref>
<ref id="B49">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ye</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Hendee</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Ruan</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Zhirova</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Ye</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Dima</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Neuron matters: neuromodulation with electromagnetic stimulation must consider neurons as dynamic identities</article-title>. <source>J. NeuroEngineering Rehabilitation</source> <volume>19</volume> (<issue>1</issue>), <fpage>116</fpage>&#x2013;<lpage>214</lpage>. <pub-id pub-id-type="doi">10.1186/s12984-022-01094-4</pub-id>
</citation>
</ref>
<ref id="B50">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhang</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Zhou</surname>
<given-names>L.-P.</given-names>
</name>
<name>
<surname>Pi</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>P.-X.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Polymer scaffolds for biomedical applications in peripheral nerve reconstruction</article-title>. <source>Molecules</source> <volume>26</volume>, <fpage>2712</fpage>. <pub-id pub-id-type="doi">10.3390/molecules26092712</pub-id>
</citation>
</ref>
<ref id="B51">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhu</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Sun</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Ramakrishna</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Chiu</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>He</surname>
<given-names>L.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Electrical stimulation affects neural stem cell fate and function <italic>in vitro</italic>
</article-title>. <source>Exp. Neurol.</source> <volume>319</volume>, <fpage>112963</fpage>. <pub-id pub-id-type="doi">10.1016/j.expneurol.2019.112963</pub-id>
</citation>
</ref>
</ref-list>
</back>
</article>