<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article article-type="research-article" dtd-version="2.3" xml:lang="EN" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Bioeng. Biotechnol.</journal-id>
<journal-title>Frontiers in Bioengineering and Biotechnology</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Bioeng. Biotechnol.</abbrev-journal-title>
<issn pub-type="epub">2296-4185</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">1259496</article-id>
<article-id pub-id-type="doi">10.3389/fbioe.2023.1259496</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Bioengineering and Biotechnology</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Biomechanical comparison of different internal fixation devices for transversely unstable Mason type II radial head fractures</article-title>
<alt-title alt-title-type="left-running-head">Zhang et al.</alt-title>
<alt-title alt-title-type="right-running-head">
<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3389/fbioe.2023.1259496">10.3389/fbioe.2023.1259496</ext-link>
</alt-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" equal-contrib="yes">
<name>
<surname>Zhang</surname>
<given-names>Xiang</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="author-notes" rid="fn001">
<sup>&#x2020;</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/2388394/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/data-curation/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/software/"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author" equal-contrib="yes">
<name>
<surname>Gong</surname>
<given-names>Ling</given-names>
</name>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<xref ref-type="author-notes" rid="fn001">
<sup>&#x2020;</sup>
</xref>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/software/"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Ma</surname>
<given-names>Hong</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/2378672/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Liu</surname>
<given-names>Jinhui</given-names>
</name>
<xref ref-type="aff" rid="aff3">
<sup>3</sup>
</xref>
<xref ref-type="corresp" rid="c001">&#x2a;</xref>
<role content-type="https://credit.niso.org/contributor-roles/data-curation/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/software/"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Duan</surname>
<given-names>Xin</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff4">
<sup>4</sup>
</xref>
<xref ref-type="corresp" rid="c001">&#x2a;</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1226110/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
<role content-type="https://credit.niso.org/contributor-roles/project-administration/"/>
<role content-type="https://credit.niso.org/contributor-roles/supervision/"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
</contrib>
</contrib-group>
<aff id="aff1">
<sup>1</sup>
<institution>Department of Orthopedic Surgery</institution>, <institution>West China Hospital</institution>, <institution>Sichuan University</institution>, <addr-line>Chengdu</addr-line>, <country>China</country>
</aff>
<aff id="aff2">
<sup>2</sup>
<institution>Department of Health Management Center</institution>, <institution>General Practice Center</institution>, <institution>West China Hospital</institution>, <institution>Sichuan University</institution>, <addr-line>Chengdu</addr-line>, <country>China</country>
</aff>
<aff id="aff3">
<sup>3</sup>
<institution>Sichuan Provincial Laboratory of Orthopaedic Engineering</institution>, <institution>Department of Bone and Joint Surgery</institution>, <institution>Affiliated Hospital of Southwest Medical University</institution>, <addr-line>Luzhou</addr-line>, <country>China</country>
</aff>
<aff id="aff4">
<sup>4</sup>
<institution>Department of Orthopedic Surgery</institution>, <institution>Sichuan Fifth People&#x2019;s Hospital</institution>, <addr-line>Chengdu</addr-line>, <country>China</country>
</aff>
<author-notes>
<fn fn-type="edited-by">
<p>
<bold>Edited by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/105690/overview">Suvash C. Saha</ext-link>, University of Technology Sydney, Australia</p>
</fn>
<fn fn-type="edited-by">
<p>
<bold>Reviewed by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/46426/overview">Rui B. Ruben</ext-link>, Polytechnic Institute of Leiria, Portugal</p>
<p>
<ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/1925775/overview">Fengyuan Zhao</ext-link>, Peking University Third Hospital, China</p>
<p>
<ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/2309469/overview">Federico Andrea Bologna</ext-link>, Polytechnic University of Turin, Italy</p>
</fn>
<corresp id="c001">&#x2a;Correspondence: Jinhui Liu, <email>Jinhui_Liu1983@163.com</email>; Xin Duan, <email>xinduan_su@163.com</email>
</corresp>
<fn fn-type="equal" id="fn001">
<label>
<sup>&#x2020;</sup>
</label>
<p>These authors have contributed equally to this work and share first authorship</p>
</fn>
</author-notes>
<pub-date pub-type="epub">
<day>18</day>
<month>12</month>
<year>2023</year>
</pub-date>
<pub-date pub-type="collection">
<year>2023</year>
</pub-date>
<volume>11</volume>
<elocation-id>1259496</elocation-id>
<history>
<date date-type="received">
<day>16</day>
<month>07</month>
<year>2023</year>
</date>
<date date-type="accepted">
<day>05</day>
<month>12</month>
<year>2023</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#xa9; 2023 Zhang, Gong, Ma, Liu and Duan.</copyright-statement>
<copyright-year>2023</copyright-year>
<copyright-holder>Zhang, Gong, Ma, Liu and Duan</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p>
</license>
</permissions>
<abstract>
<p>
<bold>Background:</bold> The integrity of the radial head is critical to maintaining elbow joint stability. For radial head fractures requiring surgical treatment, headless compression cannulated screw fixation is a less invasive scheme that has fewer complications. The aim of this study was to compare the mechanical stability of different fixation devices, including headless compression cannulated screws and mini-T-plates, for the fixation of transversely unstable radial head fractures.</p>
<p>
<bold>Methods:</bold> Forty identical synthetic radius bones were used to construct transverse unstable radial head fracture models. Parallel, cross, and tripod headless compression cannulated screw fixation and mini-T plate fixation were applied. The structural stiffness of each group was compared by static shear loading. Afterward, cyclic loading was performed in each of the three directions of the radial head, and the shear stability of each group was compared by calculating the maximum radial head displacement at the end of the cycle.</p>
<p>
<bold>Findings:</bold> The mini-T plate group had the lowest structural stiffness (51.8 &#xb1; 7.7&#xa0;N/mm) and the highest relative displacement of the radial head after cyclic loading (<italic>p</italic> &#x3c; 0.05). The tripod headless compression cannulated screw group had the highest structural stiffness among all screw groups (<italic>p</italic> &#x3c; 0.05). However, there was no significant difference in the relative displacement of the radial head between the screw groups after cyclic loading in different directions (<italic>p</italic> &#x3e; 0.05).</p>
<p>
<bold>Interpretation:</bold> In conclusion, the biomechanical stability of the mini-T plate for fixation of transverse unstable radial head fractures is lower than that of headless compression cannulated screws. Tripod fixation provides more stable fixation than parallel and cross fixation with headless compression cannulated screws for the treatment of transversely unstable radial head fractures.</p>
</abstract>
<kwd-group>
<kwd>transversely unstable radial head fractures</kwd>
<kwd>headless compression cannulated screw</kwd>
<kwd>tripod technique</kwd>
<kwd>mini-T plate</kwd>
<kwd>biomechanics</kwd>
</kwd-group>
<contract-sponsor id="cn001">National Natural Science Foundation of China<named-content content-type="fundref-id">10.13039/501100001809</named-content>
</contract-sponsor>
<custom-meta-wrap>
<custom-meta>
<meta-name>section-at-acceptance</meta-name>
<meta-value>Biomechanics</meta-value>
</custom-meta>
</custom-meta-wrap>
</article-meta>
</front>
<body>
<sec sec-type="intro" id="s1">
<title>1 Introduction</title>
<p>Radial head fracture is a common elbow injury, accounting for approximately 30% of elbow joint fractures (<xref ref-type="bibr" rid="B13">Lacheta et al., 2019</xref>; <xref ref-type="bibr" rid="B23">Sun et al., 2022</xref>). It is caused by the radial head slamming against the condyles of the humerus when the upper limb is propped up on the ground in a rotating forward external booth (<xref ref-type="bibr" rid="B16">Meacher et al., 2020</xref>). The radial head is an important component of the elbow joint, and its integrity directly affects the stability of the elbow joint and forearm function (<xref ref-type="bibr" rid="B12">Kodde et al., 2020</xref>). Therefore, it is critical to effectively restore the anatomic structure and ensure joint stability of the radial head and surrounding tissues after determining the specific stage.</p>
<p>In 1954, Mason (<xref ref-type="bibr" rid="B15">Mason, 1954</xref>) first proposed the classification of radial head fractures, which was modified by Broberg and Morrey (<xref ref-type="bibr" rid="B3">Broberg and Morrey, 1987</xref>), resulting in the most common current classification of &#x201c;Mason fractures.&#x201d; However, there is no consensus on the treatment of transversely unstable Mason II radial head fractures (M2RFs), but open reduction and internal fixation (ORIF), including screws, plates, and kerf pins, is the trend. Currently, most recommendations are based on expert opinion and lack support from scientific evidence. The incidence of complications such as internal fixation failure (<xref ref-type="bibr" rid="B28">Xu et al., 2020</xref>) and fracture nonunion (<xref ref-type="bibr" rid="B9">Golinvaux et al., 2020</xref>) remain high, and the initial stability of the fracture break is one of the main influencing factors. In the past, such fractures were fixed with plates, especially mini-T plates (MTPs), because of their small size, thin plate surface, and simple application (<xref ref-type="bibr" rid="B29">Yang et al., 2023</xref>). Moreover, plates have been shown to lead to favorable biomechanical outcomes in the treatment of axially unstable radial head fractures (<xref ref-type="bibr" rid="B29">Yang et al., 2023</xref>). Recently, headless compression cannulated screws (HCCSs) have been used for the treatment of M2RFs because of their advantages such as greater fixation strength and unrestricted fixation position (<xref ref-type="bibr" rid="B1">Al-Tawil and Arya, 2021</xref>; <xref ref-type="bibr" rid="B10">Gray et al., 2022</xref>). However, it is uncertain whether MTP or HCCSs are biomechanically superior in the treatment of transversely unstable M2RFs.</p>
<p>The aim of this study was to compare the strength of the fixation of transversely unstable M2RFs by using biomechanical testing (BT) with parallel cross-implantation of two HCCSs, tripod technique of three HCCSs, and MTPs to provide a biomechanical basis for the selection of internal fixation devices for the surgical treatment of transversely unstable M2RFs.</p>
</sec>
<sec sec-type="methods" id="s2">
<title>2 Methods</title>
<sec id="s2-1">
<title>2.1 Specimens</title>
<p>Forty synthetic radius bones of identical size and density (Synbone 7220, Synbone AG) were used in this study. These synthetic radius bones were 255&#xa0;mm in length, with a 13&#xb0; valgus angle and a radial head diameter of 27&#xa0;mm. In this study, transversely unstable radial head fractures were established according to the experimental protocol of Chen et al. (<xref ref-type="bibr" rid="B6">Chen et al., 2017</xref>). A miniature table saw was used to make osteotomies at the junction of the radial head and radial neck in each specimen to ensure consistent fracture modeling in each group. Moreover, we intercepted the proximal 10&#xa0;cm of the radius for biomechanical experiments and fixed each group of M2RF models using HCCSs (Arthrex Corporation, United States) and a MTP (Synthes Corporation, United States). These specimens were divided into the following four groups (<xref ref-type="fig" rid="F1">Figure 1</xref>) according to the internal fixation method: parallel HCCSs group (G-PS), crossed HCCSs group (G-CS), tripod HCCSs group (G-TS) and MTP group (G-TP).</p>
<fig id="F1" position="float">
<label>FIGURE 1</label>
<caption>
<p>The transversely unstable M2RF models in each group. <bold>(A)</bold> G-PS group: two HCCSs were inserted parallel to the top outer edge of the radial head at 45&#xb0; to the radial head axis; <bold>(B)</bold> G-CS group: two HCCSs were placed approximately 60&#xb0; apart and buried below the articular cartilage surface; <bold>(C)</bold>: G-TS group: three HCCSs were distributed circumferentially around the radial head to form a tripod; <bold>(D)</bold>: G-0TP group: the MTP was prebent and shaped according to the radial head and placed in the radial safety zone.</p>
</caption>
<graphic xlink:href="fbioe-11-1259496-g001.tif"/>
</fig>
</sec>
<sec id="s2-2">
<title>2.2 Surgical technique</title>
<p>Osteosynthesis was performed for all the specimens by the same surgeon. In G-PS, two 3.0&#xa0;mm HCCSs were inserted parallel to the top outer edge of the radial head at 45&#xb0; to the radial head axis, with the two screws being the same length and approximately 5&#xa0;mm apart. In G-CS, the two HCCSs were placed approximately 60&#xb0; apart and buried below the articular cartilage surface. The screw tip was also placed less than 2&#xa0;mm beyond the contralateral cortex to avoid interference with the ulna. In G-TS, based on the tripod technique proposed by <xref ref-type="bibr" rid="B14">Lipman et al., 2018</xref>, three HCCSs were distributed circumferentially around the radial head to form a tripod. In G-TP, the 2.0&#xa0;mm MTP was prebent and shaped according to the anatomy of the radial head and placed in the radial safety zone, located dorsal to the radius. The position of the internal fixation was evaluated using X-ray. Radiological examination of transversely unstable M2RF models fixed by the four fixation methods mentioned above was performed using a C-arm X-ray machine (Ziehm Imaging, Germany) (<xref ref-type="fig" rid="F2">Figure 2</xref>).</p>
<fig id="F2" position="float">
<label>FIGURE 2</label>
<caption>
<p>Anteroposterior and lateral views of the X-ray films in each group. <bold>(A,B)</bold> G-PS group; <bold>(C,D)</bold> G-CS group; <bold>(E,F)</bold> G-TS group; <bold>(G,H)</bold> G-TP group. Arrows indicate the position of the fracture line in the fracture models.</p>
</caption>
<graphic xlink:href="fbioe-11-1259496-g002.tif"/>
</fig>
</sec>
<sec id="s2-3">
<title>2.3 Static shear experiment</title>
<p>A total of 20 transversely unstable M2RF models were randomly selected from each group for the static shear experiment. Testing was conducted by the INSTRON universal mechanical testing machine (INSTRON Corporation, United States) (<xref ref-type="fig" rid="F3">Figure 3</xref>). The distal ends of the fracture models were fixed to the experimental table using custom-made clamps. A shearing force was applied to the radial head fragment at a distance of 5&#xa0;mm from the fracture line at a rate of 2&#xa0;mm/min from the posterior to the anterior side of the radius (<xref ref-type="bibr" rid="B6">Chen et al., 2017</xref>). In this way, the shear force from the ulnar sigmoid notch was simulated during the rotation of the radial head. The experiment was stopped when the radial head became displaced by 2&#xa0;mm or the internal fixation failed, and the force&#x2012;displacement curves in each group were plotted to analyze the structural stiffness and overall stability. Then, the structural stiffness of each model was calculated by the force&#x2012;displacement curves. Implant failure was defined as (<xref ref-type="bibr" rid="B26">Wang et al., 2018</xref>) 1) the appearance of a new fracture line in the model in addition to the original fracture line; 2) bending, cutting out, or fracture of MTPs or HCCSs; 3) shear displacement of the radial head exceeding 2&#xa0;mm; and 4) flattening of the force&#x2012;displacement curve in the data acquisition system or no significant change in the displacement of the model when the load continued to be increased.</p>
<fig id="F3" position="float">
<label>FIGURE 3</label>
<caption>
<p>Experimental test setup. <bold>(A)</bold> The transversely unstable M2RF models were fixed to the experimental table to apply shear loads; <bold>(B)</bold> Shear loads were applied to each sample in each of the three directions to simulate the shear force exerted by the ulna on the radial head in the sigmoid notch during forearm rotation.</p>
</caption>
<graphic xlink:href="fbioe-11-1259496-g003.tif"/>
</fig>
</sec>
<sec id="s2-4">
<title>2.4 Cycle shear experiment</title>
<p>The remaining 4 groups of 20 transversely unstable M2RF models were used for the low-cycle shear experiment. A cyclic loading scheme of 4&#xa0;Hz was set in the software Instron Wave Matrix2 (INSTRON Corporation, United States), and 300 shear loading cycles were applied to obtain information about the relative displacement of the fragments (<xref ref-type="bibr" rid="B25">Wagner et al., 2020</xref>). A load of 20&#xa0;N was applied sequentially in each of the three loading directions: posterior to anterior (P-A), ulnar to radial (U-R), and anterior to posterior (A-P), to simulate the shear load generated by the ulnar sigmoid tuberosity on the radial head during anterior-posterior rotation of the forearm. The relative displacement of the radial head at the end of the cyclic shear test at each load application point and the maximum displacement in each cyclic cycle were recorded. The time&#x2012;displacement curves of each group were analyzed, and the shear stability of each group was compared by the maximum displacement of the last cycle loading.</p>
</sec>
<sec id="s2-5">
<title>2.5 Statistical analysis</title>
<p>Statistical analysis was conducted using GraphPad Prism 9. First, the Shapiro&#x2012;Wilk test was used to test whether the data of each group coincided with a normal distribution, and if the data coincided with a normal distribution, the <italic>t</italic>-test was used to compare the data between groups; if not, the rank sum test was used to analyze the data between groups. <italic>p</italic> &#x3c; 0.05 was defined as statistically significant.</p>
</sec>
</sec>
<sec sec-type="results" id="s3">
<title>3 Results</title>
<sec id="s3-1">
<title>3.1 Construct stiffness</title>
<p>The results of the static shear experiment indicated that the G-TP showed the weakest shear stiffness among the groups with 51.8 &#xb1; 7.7&#xa0;N/mm, while the G-TS exhibited the strongest shear stiffness with 136.8 &#xb1; 11.8&#xa0;N/mm. Moreover, the mean value of shear stiffness was 94.4 &#xb1; 7.4&#xa0;N/mm in the G-PS and 116.7 &#xb1; 6.7&#xa0;N/mm in the G-CS. There was a statistically significant difference in shear stiffness among the four groups (<xref ref-type="fig" rid="F4">Figure 4</xref>).</p>
<fig id="F4" position="float">
<label>FIGURE 4</label>
<caption>
<p>Comparison of shear stiffness of a total of 40 experimental samples from the G-PS, G-CS, G-TS and G-TP groups. <bold>(A)</bold> Four groups of displacement&#x2012;load curves, where the slope of the curve represents the shear stiffness of each group; <bold>(B)</bold> Load value of each group when the displacement reaches 2&#xa0;mm. The standard deviation is represented with the range bars on top of each graph. (&#x2a;<italic>p</italic> &#x3c; 0.05).</p>
</caption>
<graphic xlink:href="fbioe-11-1259496-g004.tif"/>
</fig>
</sec>
<sec id="s3-2">
<title>3.2 Changes after cyclic loading</title>
<p>The relative displacement of the radial head in the G-PS was 0.086 &#xb1; 0.008&#xa0;mm (P-A), 0.065 &#xb1; 0.017&#xa0;mm (U-R), and 0.070 &#xb1; 0.015&#xa0;mm (A-P); in the G-CS was 0.077 &#xb1; 0.007&#xa0;mm (P-A), 0.066 &#xb1; 0.015&#xa0;mm (U-R) and 0.074 &#xb1; 0.019&#xa0;mm (A-P), respectively; in the G-TS was 0.069 &#xb1; 0.014&#xa0;mm (P-A), 0.070 &#xb1; 0.006&#xa0;mm (U-R) and 0.052 &#xb1; 0.008&#xa0;mm (A-P), respectively; in the G-TP was 0.492 &#xb1; 0.102&#xa0;mm (P-A), 0.337 &#xb1; 0.043&#xa0;mm (U-R) and 0.489 &#xb1; 0.047 (A-P), respectively (<xref ref-type="table" rid="T1">Table 1</xref>). After the low cycle loading test, in the P-A direction, the G-TS showed the smallest relative displacement among all groups, and the difference was statistically significant; in the U-R direction, the G-PS exhibited the smallest relative displacement; in the A-P direction, the G-TS showed the smallest relative displacement. Moreover, each cycle during low cycle loading at different positions indicated that the maximum displacement of the G-TP was greater than that of all HCCs groups (<xref ref-type="fig" rid="F5">Figures 5</xref>, <xref ref-type="fig" rid="F6">6</xref>).</p>
<table-wrap id="T1" position="float">
<label>TABLE 1</label>
<caption>
<p>Relative displacement of the radial head in each of the three loading directions of posterior to anterior (P-A), ulnar to radial (U-R), and anterior to posterior (A-P) at the end of the cyclic shear test in the G-PS, G-CS, G-TS and G-TP groups.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="left"/>
<th align="left">G-PS</th>
<th align="left">G-CS</th>
<th align="left">G-TS</th>
<th align="left">G-TP</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="left">P-A (mm)</td>
<td align="left">0.086 &#xb1; 0.008</td>
<td align="left">0.077 &#xb1; 0.007</td>
<td align="left">0.069 &#xb1; 0.014</td>
<td align="left">0.492 &#xb1; 0.102</td>
</tr>
<tr>
<td align="left">U-R (mm)</td>
<td align="left">0.065 &#xb1; 0.017</td>
<td align="left">0.066 &#xb1; 0.015</td>
<td align="left">0.070 &#xb1; 0.006</td>
<td align="left">0.337 &#xb1; 0.043</td>
</tr>
<tr>
<td align="left">A-P (mm)</td>
<td align="left">0.070 &#xb1; 0.015</td>
<td align="left">0.074 &#xb1; 0.019</td>
<td align="left">0.052 &#xb1; 0.008</td>
<td align="left">0.489 &#xb1; 0.047</td>
</tr>
</tbody>
</table>
</table-wrap>
<fig id="F5" position="float">
<label>FIGURE 5</label>
<caption>
<p>Maximum relative displacement of each group in each of the three loading directions of posterior to anterior (P-A), ulnar to radial (U-R), and anterior to posterior (A-P) after cyclic load loading.</p>
</caption>
<graphic xlink:href="fbioe-11-1259496-g005.tif"/>
</fig>
<fig id="F6" position="float">
<label>FIGURE 6</label>
<caption>
<p>Peak relative displacement curve for the G-PS, G-CS, G-TS, and G-TP groups in each of the three loading directions of posterior to anterior (P-A), ulnar to radial (U-R), and anterior to posterior (A-P) during the cyclic shear experiment.</p>
</caption>
<graphic xlink:href="fbioe-11-1259496-g006.tif"/>
</fig>
</sec>
</sec>
<sec sec-type="discussion" id="s4">
<title>4 Discussion</title>
<p>Conservative treatment for M2RFs predisposes patients to complications such as elbow pain, decreased grip strength, and lateral elbow instability because of the inability to achieve fracture end reduction (<xref ref-type="bibr" rid="B19">Nietschke et al., 2018</xref>; <xref ref-type="bibr" rid="B27">Wen et al., 2022</xref>). It has long been accepted that M2RF with displacement &#x2265;2&#xa0;mm requires ORIF (<xref ref-type="bibr" rid="B21">Ruchelsman et al., 2013</xref>). Zarattini et al. (<xref ref-type="bibr" rid="B31">Zarattini et al., 2012</xref>) conducted a 10-year retrospective controlled study of M2RFs and reported less residual pain and greater joint mobility in M2RF patients who underwent ORIF. Maintaining the stability of radial head fractures remains a challenge for orthopedic surgeons due to the potential to cause problems such as combined elbow injuries (<xref ref-type="bibr" rid="B17">Mellema et al., 2016</xref>). Studies have shown that a MTP and HCCs have favorable biomechanical outcomes in fixing axially unstable radial head fractures (<xref ref-type="bibr" rid="B7">Demiroglu et al., 2016</xref>; <xref ref-type="bibr" rid="B29">Yang et al., 2023</xref>; <xref ref-type="bibr" rid="B32">Zhang et al., 2023</xref>). However, it is uncertain whether MTP or HCCSs have a biomechanical advantage in fixing transversely unstable radial head fractures. Long-term stable fixation not only promotes early postoperative functional exercise and accelerated elbow rehabilitation but also reduces the incidence of complications. Therefore, in this study, we investigated the biomechanical stability of four different internal fixation methods for the treatment of transversely unstable M2RFs, which provided a biomechanical basis for the choice of internal fixation options for the treatment of M2RFs.</p>
<p>In the static shear experiment, the structural stiffness of each HCCSs group was significantly greater than that of the MTP group, indicating that the HCCSs provided better shear resistance than the MTP. This may be because the HCCSs in each group crossed the fracture end on both sides and gave continuous compression to the fracture surface, and the MTP may lack a rigid connection at the fracture. Moreover, <xref ref-type="bibr" rid="B32">Zhang et al., 2023</xref> conducted a study of follow-up outcomes after ORIF of M2RFs and found that fixation with MTP was associated with higher incidences (10-fold) of complications and reoperations than screws alone. The position and protrusion of the plate are among the important contributing factors. The greatest advantage of HCCSs is that they can be inserted into any part of the radial head with minimal dissection and provide considerable biomechanical stability. Hence, fixation with HCCSs is preferred, especially for transversely unstable M2RFs. Compared to G-PS and G-CS, G-TS showed the greatest stiffness and less relative displacement under low cyclic shear loading, showing the better biomechanical stability of three HCCSs for fixation of transversely unstable M2RFs with tripod-type implantation. <xref ref-type="bibr" rid="B18">Model et al., 2022</xref> followed 13 patients with radial neck fractures treated with HCCSs for up to 72&#xa0;months and showed that the tripod technique is an effective alternative to conventional plate screw fixation of unstable M2RFs. A biomechanical study by <xref ref-type="bibr" rid="B20">Rebgetz et al., 2019</xref> showed that there was no difference in fixation stiffness between the HCCSs placed in a tripod-type design and the locking plate for axially unstable M3RFs, and one of the main drawback associated with plate fixation was soft tissue irritation. This experiment expands current knowledge regarding biomechanical experiments of transversely unstable M2RFs, providing valid biomechanical evidence. In addition, although G-CS exhibited less stiffness and relative displacement than G-TS, it is also commonly used in clinical practice to treat fractures of the radial head and radial neck. <xref ref-type="bibr" rid="B11">Gutowski et al. (2015)</xref> used a simple biomechanical experiment to compare the mechanical performance of crossed screw and plate fixation for radial neck fractures and showed that both internal fixation modalities exhibited similar biomechanical stability in the treatment of transverse, noncomminuted radial neck fractures.</p>
<p>Interestingly, the relative displacements of each HCCS group in the three directions were not significantly different. Therefore, it can be speculated that to some extent, when increasing the number of screws or changing the screw fixation method, the relative displacement and stiffness of the fracture end do not change significantly. <xref ref-type="bibr" rid="B24">Tarallo et al., 2018</xref> reviewed the clinical and radiographic data of 61 patients with radial head fractures treated with mini-screws and found that varying numbers of mini-screws provided adequate strength and stiffness in patients with radial head fractures and that these patients had good clinical and functional scores at the mid-term follow-up. This suggests that the number of screws and the method of fixation may have little effect on the overall stability of the elbow joint. <xref ref-type="bibr" rid="B2">Amanatullah et al., 2012</xref> evaluated the biomechanical performance of three screw orientations for the fixation of vertical shear fractures of the inner ankle. They concluded that when the screws are not placed parallel, only the first screw produces a compression effect, and any nonparallel screws do not add additional compression but serve to stabilize rotation, translation, etc. Similar conclusions can be drawn from our results: when the first screw acts as a compression, the additional implanted HCCSs act as a resistance to fracture surface translation in the P-A and U-R directions. However, parallel fixation of the fracture ends seems to provide sufficient resistance to shear forces, and increasing the number of screws or changing the screw configuration to increase the resistance to rotation and translation is not significant enough, which requires further confirmation by experiments with applied torsional loads. Since the biomechanical stability of the G-CS and G-TS was not significantly improved compared to that of the G-PS, operators may consider the use of two HCCSs implanted in parallel to fix the fracture ends when treating transversely unstable M2RFs. During surgical treatment, implantation of HCCSs, either in a crossed or tripod fashion, does not allow simultaneous exposure of the implantation site of the HCCSs if the forearm cannot be rotated (<xref ref-type="bibr" rid="B18">Model et al., 2022</xref>; <xref ref-type="bibr" rid="B30">Yano et al., 2023</xref>). Especially with tripod implantation of HCCSs, interference between screws may occur. Moreover, the stability of the internal fixation may be reduced during repeated retraction of the screws to adjust their optimal position. In contrast, parallel implantation of HCCSs requires only a small incision and fixation of the fracture break to the radial shaft at a 45&#xb0; angle, without rotation of the forearm. Therefore, in the surgical treatment of transversely unstable radial head fractures, parallel screw fixation may have the advantage of simpler manipulation and an even shorter operative time while providing the same fixation strength.</p>
<p>Most of the current biomechanical experiments on M2RFs are static experiments, and there are almost no cycle loading experiments to simulate postoperative functional exercise. Additionally, this study simulated the mechanics of postoperative functional exercise for transversely unstable M2RFs through low circulation shear experiments, providing a biomechanical basis for the selection of internal fixation protocols for clinical treatment. From the results of the cycle loading experiments, the maximum relative displacement values of the HCCS groups were significantly smaller than those of the MTP group (<xref ref-type="fig" rid="F6">Figure 6</xref>). This indicated that during postoperative forearm rotation, the stability of HCCSs for transversely unstable M2RFs was significantly better than that of MTP under the cyclic action of shear resistance. The MTP fixated only the radial side of the fracture end and lacked the compression effect on the fracture end, similar to the HCCSs; therefore, the relative displacement was significantly greater when subjected to shear forces. In addition, it is noteworthy that the relative displacements of each HCCS in different directions did not differ significantly after experiencing low cycle shear loading in different directions, and the difference was not statistically significant. <xref ref-type="bibr" rid="B8">Giffin et al., 2004</xref> performed <italic>in vitro</italic> biomechanical experiments on crossed screws as well as plates for radial neck fractures, and the results showed that different orientations did not significantly affect the stiffness of various internal fixations, which is consistent with our findings. The relative displacements of the HCCSs group and the maximum displacements of each loading cycle under shear loads in different directions were significantly smaller than those of the MTP group, and no internal fixation failure occurred, which further proved the reliability of HCCSs for transversely unstable M2RFs.</p>
<p>Axial compression testing does not demonstrate variability between internal fixation techniques because the fracture ends compress against each other when axial loading is applied, and little mechanical difference is produced between groups. In addition, torsional loading is unlikely to be the cause of internal fixation failure due to the lack of restraint at the proximal end of the radius. Therefore, we chose multidirectional shear loading and conducted experiments by low-cycle loading and static tests to reach the conclusions of this study. Increasing the sample size may help to identify subtle differences between different internal fixation methods. In addition, the present study has some limitations. Soft tissues such as muscles and ligaments were not simulated in this experiment to mimic the mechanical characteristics of the real human elbow joint. They also play an important role in the overall stability of the elbow joint (<xref ref-type="bibr" rid="B22">Strafun et al., 2018</xref>). However, most of the biomechanical experiments simplified the design of the experimental protocols to perform biomechanical experiments on radial head fractures <italic>in vitro</italic> (<xref ref-type="bibr" rid="B4">Burkhart et al., 2007</xref>; <xref ref-type="bibr" rid="B5">Burkhart et al., 2010</xref>; <xref ref-type="bibr" rid="B11">Gutowski et al., 2015</xref>), which supports the comparability of this study.</p>
</sec>
<sec sec-type="conclusion" id="s5">
<title>5 Conclusion</title>
<p>HCCS fixation for the treatment of laterally unstable M2RFs is a simple, minimally invasive surgical procedure that demonstrates better stability than mini-T-plates during simulated postoperative forearm rotation. Among the four internal fixation strategies analyzed in this study, tripod HCCS fixation was the best choice for the treatment of laterally unstable M2RFs. Specifically, in the surgical treatment of transversely unstable radial head fractures, we recommend tripod HCCS fixation. In addition, the conclusions of this study need to be validated by a large number of clinical studies.</p>
</sec>
</body>
<back>
<sec sec-type="data-availability" id="s6">
<title>Data availability statement</title>
<p>The raw data supporting the conclusion of this article will be made available by the authors, without undue reservation.</p>
</sec>
<sec id="s7">
<title>Author contributions</title>
<p>XZ: Data curation, Methodology, Software, Writing&#x2013;review and editing. LG: Investigation, Methodology, Software, Writing&#x2013;review and editing. HM: Writing&#x2013;original draft. JL: Data curation, Methodology, Software, Writing&#x2013;review and editing. XD: Conceptualization, Investigation, Project administration, Supervision, Writing&#x2013;review and editing.</p>
</sec>
<sec id="s8">
<title>Funding</title>
<p>The author(s) declare financial support was received for the research, authorship, and/or publication of this article. This work was supported by the National Natural Science Foundation of China (Grant No. 31870961), the International Cooperation Project of the Science and Technology Department of Sichuan Province (Grant No. 2020YFS0099), and Clinical Research Incubation project of West China Hospital of Sichuan University (Grant No. 2019HXFH041).</p>
</sec>
<ack>
<p>We would like to thank Dr. Jialei Chen for his assistance in the conduction of building fracture models.</p>
</ack>
<sec sec-type="COI-statement" id="s9">
<title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec sec-type="disclaimer" id="s10">
<title>Publisher&#x2019;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<sec id="s11">
<title>Supplementary material</title>
<p>The Supplementary Material for this article can be found online at: <ext-link ext-link-type="uri" xlink:href="https://www.frontiersin.org/articles/10.3389/fbioe.2023.1259496/full#supplementary-material">https://www.frontiersin.org/articles/10.3389/fbioe.2023.1259496/full&#x23;supplementary-material</ext-link>
</p>
<supplementary-material xlink:href="DataSheet1.XLSX" id="SM1" mimetype="application/XLSX" xmlns:xlink="http://www.w3.org/1999/xlink"/>
</sec>
<ref-list>
<title>References</title>
<ref id="B1">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Al-Tawil</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Arya</surname>
<given-names>A.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Radial head fractures</article-title>. <source>J. Clin. Orthop. Trauma</source> <volume>20</volume>, <fpage>101497</fpage>. <pub-id pub-id-type="doi">10.1016/j.jcot.2021.101497</pub-id>
</citation>
</ref>
<ref id="B2">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Amanatullah</surname>
<given-names>D. F.</given-names>
</name>
<name>
<surname>Khan</surname>
<given-names>S. N.</given-names>
</name>
<name>
<surname>Curtiss</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Wolinsky</surname>
<given-names>P. R.</given-names>
</name>
</person-group> (<year>2012</year>). <article-title>Effect of divergent screw fixation in vertical medial malleolus fractures</article-title>. <source>J. Trauma Acute Care Surg.</source> <volume>72</volume> (<issue>3</issue>), <fpage>751</fpage>&#x2013;<lpage>754</lpage>. <pub-id pub-id-type="doi">10.1097/ta.0b013e31823b8b9f</pub-id>
</citation>
</ref>
<ref id="B3">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Broberg</surname>
<given-names>M. A.</given-names>
</name>
<name>
<surname>Morrey</surname>
<given-names>B. F.</given-names>
</name>
</person-group> (<year>1987</year>). <article-title>Results of treatment of fracture-dislocations of the elbow</article-title>. <source>Clin. Orthop. Relat. Research</source> <volume>216</volume>, <fpage>109</fpage>&#x2013;<lpage>119</lpage>. <pub-id pub-id-type="doi">10.1097/00003086-198703000-00017</pub-id>
</citation>
</ref>
<ref id="B4">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Burkhart</surname>
<given-names>K. J.</given-names>
</name>
<name>
<surname>Mueller</surname>
<given-names>L. P.</given-names>
</name>
<name>
<surname>Krezdorn</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Appelmann</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Prommersberger</surname>
<given-names>K. J.</given-names>
</name>
<name>
<surname>Sternstein</surname>
<given-names>W.</given-names>
</name>
<etal/>
</person-group> (<year>2007</year>). <article-title>Stability of radial head and neck fractures: a biomechanical study of six fixation constructs with consideration of three locking plates</article-title>. <source>J. Hand Surg. Am.</source> <volume>32</volume> (<issue>10</issue>), <fpage>1569</fpage>&#x2013;<lpage>1575</lpage>. <pub-id pub-id-type="doi">10.1016/j.jhsa.2007.08.023</pub-id>
</citation>
</ref>
<ref id="B5">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Burkhart</surname>
<given-names>K. J.</given-names>
</name>
<name>
<surname>Nowak</surname>
<given-names>T. E.</given-names>
</name>
<name>
<surname>Appelmann</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Sternstein</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Rommens</surname>
<given-names>P. M.</given-names>
</name>
<name>
<surname>Mueller</surname>
<given-names>L. P.</given-names>
</name>
</person-group> (<year>2010</year>). <article-title>Screw fixation of radial head fractures: compression screw versus lag screw--a biomechanical comparison</article-title>. <source>Injury</source> <volume>41</volume> (<issue>10</issue>), <fpage>1015</fpage>&#x2013;<lpage>1019</lpage>. <pub-id pub-id-type="doi">10.1016/j.injury.2010.03.001</pub-id>
</citation>
</ref>
<ref id="B6">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Chen</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Wu</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Pan</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Pan</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Shi</surname>
<given-names>X.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>Comparison of three different fixation constructs for radial neck fractures: a biomechanical study</article-title>. <source>J. Orthop. Surg. Res.</source> <volume>12</volume> (<issue>1</issue>), <fpage>175</fpage>. <pub-id pub-id-type="doi">10.1186/s13018-017-0680-2</pub-id>
</citation>
</ref>
<ref id="B7">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Demiroglu</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Ozturk</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Baydar</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Kumbuloglu</surname>
<given-names>O. F.</given-names>
</name>
<name>
<surname>Sencan</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Aykut</surname>
<given-names>S.</given-names>
</name>
<etal/>
</person-group> (<year>2016</year>). <article-title>Results of screw fixation in Mason type II radial head fractures</article-title>. <source>SpringerPlus</source> <volume>5</volume> (<issue>1</issue>), <fpage>545</fpage>. <pub-id pub-id-type="doi">10.1186/s40064-016-2189-2</pub-id>
</citation>
</ref>
<ref id="B8">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Giffin</surname>
<given-names>J. R.</given-names>
</name>
<name>
<surname>King</surname>
<given-names>G. J.</given-names>
</name>
<name>
<surname>Patterson</surname>
<given-names>S. D.</given-names>
</name>
<name>
<surname>Johnson</surname>
<given-names>J. A.</given-names>
</name>
</person-group> (<year>2004</year>). <article-title>Internal fixation of radial neck fractures: an <italic>in vitro</italic> biomechanical analysis</article-title>. <source>Clin. Biomech.</source> <volume>19</volume> (<issue>4</issue>), <fpage>358</fpage>&#x2013;<lpage>361</lpage>. <pub-id pub-id-type="doi">10.1016/j.clinbiomech.2004.01.003</pub-id>
</citation>
</ref>
<ref id="B9">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Golinvaux</surname>
<given-names>N. S.</given-names>
</name>
<name>
<surname>Labrum</surname>
<given-names>J. T.</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>D. H.</given-names>
</name>
<name>
<surname>Desai</surname>
<given-names>M. J.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Symptomatic radial neck nonunion following traumatic impacted radial neck fracture</article-title>. <source>J. Hand Surg.</source> <volume>45</volume> (<issue>5</issue>), <fpage>453.e1</fpage>&#x2013;<lpage>453.e5</lpage>. <pub-id pub-id-type="doi">10.1016/j.jhsa.2019.10.012</pub-id>
</citation>
</ref>
<ref id="B10">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Gray</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Hoekzema</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Rubio</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Heifner</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Imada</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Dark</surname>
<given-names>N.</given-names>
</name>
<etal/>
</person-group> (<year>2022</year>). <article-title>Avoiding articular breakthrough in screw fixation of radial head fractures</article-title>. <source>JSES Int.</source> <volume>6</volume> (<issue>4</issue>), <fpage>704</fpage>&#x2013;<lpage>708</lpage>. <pub-id pub-id-type="doi">10.1016/j.jseint.2022.03.002</pub-id>
</citation>
</ref>
<ref id="B11">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Gutowski</surname>
<given-names>C. J.</given-names>
</name>
<name>
<surname>Darvish</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Ilyas</surname>
<given-names>A. M.</given-names>
</name>
<name>
<surname>Jones</surname>
<given-names>C. M.</given-names>
</name>
</person-group> (<year>2015</year>). <article-title>Comparison of crossed screw versus plate fixation for radial neck fractures</article-title>. <source>Clin. Biomech. (Bristol, Avon)</source> <volume>30</volume> (<issue>9</issue>), <fpage>966</fpage>&#x2013;<lpage>970</lpage>. <pub-id pub-id-type="doi">10.1016/j.clinbiomech.2015.07.001</pub-id>
</citation>
</ref>
<ref id="B12">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kodde</surname>
<given-names>I. F.</given-names>
</name>
<name>
<surname>Viveen</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>The</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>van Riet</surname>
<given-names>R. P.</given-names>
</name>
<name>
<surname>Eygendaal</surname>
<given-names>D.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Management of the failed radial head arthroplasty</article-title>. <source>EFORT Open Rev.</source> <volume>5</volume> (<issue>7</issue>), <fpage>398</fpage>&#x2013;<lpage>407</lpage>. <pub-id pub-id-type="doi">10.1302/2058-5241.5.190055</pub-id>
</citation>
</ref>
<ref id="B13">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lacheta</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Siebenlist</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Lauber</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Willinger</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Fischer</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Imhoff</surname>
<given-names>A. B.</given-names>
</name>
<etal/>
</person-group> (<year>2019</year>). <article-title>Proximal radius fracture morphology following axial force impact: a biomechanical evaluation of fracture patterns</article-title>. <source>BMC Musculoskelet. Disord.</source> <volume>20</volume> (<issue>1</issue>), <fpage>147</fpage>. <pub-id pub-id-type="doi">10.1186/s12891-019-2529-9</pub-id>
</citation>
</ref>
<ref id="B14">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lipman</surname>
<given-names>M. D.</given-names>
</name>
<name>
<surname>Gause</surname>
<given-names>T. M.</given-names>
</name>
<name>
<surname>Teran</surname>
<given-names>V. A.</given-names>
</name>
<name>
<surname>Chhabra</surname>
<given-names>A. B.</given-names>
</name>
<name>
<surname>Deal</surname>
<given-names>D. N.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Radial head fracture fixation using tripod technique with headless compression screws</article-title>. <source>J. Hand Surg. Am.</source> <volume>43</volume> (<issue>6</issue>), <fpage>575.e1</fpage>&#x2013;<lpage>575.e6</lpage>. <pub-id pub-id-type="doi">10.1016/j.jhsa.2018.03.009</pub-id>
</citation>
</ref>
<ref id="B15">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mason</surname>
<given-names>M. L.</given-names>
</name>
</person-group> (<year>1954</year>). <article-title>Some observations on fractures of the head of the radius with a review of one hundred cases</article-title>. <source>J. Br. Surg.</source> <volume>42</volume> (<issue>172</issue>), <fpage>123</fpage>&#x2013;<lpage>132</lpage>. <pub-id pub-id-type="doi">10.1002/bjs.18004217203</pub-id>
</citation>
</ref>
<ref id="B16">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Meacher</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Hermena</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Isaac</surname>
<given-names>S.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Open reduction and internal fixation versus radial head arthroplasty for Mason III radial head fractures: appraising the current literature evidence</article-title>. <source>Cureus</source> <volume>12</volume> (<issue>4</issue>), <fpage>e7501</fpage>. <pub-id pub-id-type="doi">10.7759/cureus.7501</pub-id>
</citation>
</ref>
<ref id="B17">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mellema</surname>
<given-names>J. J.</given-names>
</name>
<name>
<surname>Eygendaal</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>van Dijk</surname>
<given-names>C. N.</given-names>
</name>
<name>
<surname>Ring</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Doornberg</surname>
<given-names>J. N.</given-names>
</name>
</person-group> (<year>2016</year>). <article-title>Fracture mapping of displaced partial articular fractures of the radial head</article-title>. <source>J. Shoulder Elb. Surg.</source> <volume>25</volume> (<issue>9</issue>), <fpage>1509</fpage>&#x2013;<lpage>1516</lpage>. <pub-id pub-id-type="doi">10.1016/j.jse.2016.01.030</pub-id>
</citation>
</ref>
<ref id="B18">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Model</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Merchan</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Rozental</surname>
<given-names>T. D.</given-names>
</name>
<name>
<surname>Harper</surname>
<given-names>C. M.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Outcomes of radial head fractures treated with the "tripod technique</article-title>. <source>J. Hand Surg. Am.</source> <volume>47</volume> (<issue>6</issue>), <fpage>582.e1</fpage>&#x2013;<lpage>582.e5</lpage>. <pub-id pub-id-type="doi">10.1016/j.jhsa.2021.06.014</pub-id>
</citation>
</ref>
<ref id="B19">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Nietschke</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Burkhart</surname>
<given-names>K. J.</given-names>
</name>
<name>
<surname>Hollinger</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Dehlinger</surname>
<given-names>F. I.</given-names>
</name>
<name>
<surname>Zimmerer</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Schneider</surname>
<given-names>M. M.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Reasons for surgical revision after conservatively treated radial head fractures&#x2014;retrospective study of 70 patients</article-title>. <source>Obere Extrem.</source> <volume>13</volume> (<issue>2</issue>), <fpage>112</fpage>&#x2013;<lpage>120</lpage>. <pub-id pub-id-type="doi">10.1007/s11678-018-0456-2</pub-id>
</citation>
</ref>
<ref id="B20">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Rebgetz</surname>
<given-names>P. R.</given-names>
</name>
<name>
<surname>Daniele</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Underhill</surname>
<given-names>I. D.</given-names>
</name>
<name>
<surname>&#xd6;chsner</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Taylor</surname>
<given-names>F. J.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>A biomechanical study of headless compression screws versus a locking plate in radial head fracture fixation</article-title>. <source>J. Shoulder Elb. Surg.</source> <volume>28</volume> (<issue>4</issue>), <fpage>e111</fpage>&#x2013;<lpage>e116</lpage>. <pub-id pub-id-type="doi">10.1016/j.jse.2018.10.008</pub-id>
</citation>
</ref>
<ref id="B21">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ruchelsman</surname>
<given-names>D. E.</given-names>
</name>
<name>
<surname>Christoforou</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Jupiter</surname>
<given-names>J. B.</given-names>
</name>
</person-group> (<year>2013</year>). <article-title>Fractures of the radial head and neck</article-title>. <source>J. Bone Jt. Surg. Am.</source> <volume>95</volume> (<issue>5</issue>), <fpage>469</fpage>&#x2013;<lpage>478</lpage>. <pub-id pub-id-type="doi">10.2106/jbjs.j.01989</pub-id>
</citation>
</ref>
<ref id="B22">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Strafun</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Levadnyi</surname>
<given-names>I.</given-names>
</name>
<name>
<surname>Makarov</surname>
<given-names>V.</given-names>
</name>
<name>
<surname>Awrejcewicz</surname>
<given-names>J.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Comparative biomechanical analysis of stress-strain state of the elbow joint after displaced radial head fractures</article-title>. <source>J. Med. Biol. Eng.</source> <volume>38</volume> (<issue>4</issue>), <fpage>618</fpage>&#x2013;<lpage>624</lpage>. <pub-id pub-id-type="doi">10.1007/s40846-017-0334-1</pub-id>
</citation>
</ref>
<ref id="B23">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sun</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Jiang</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Zha</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Gong</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Hua</surname>
<given-names>K.</given-names>
</name>
<etal/>
</person-group> (<year>2022</year>). <article-title>Relationship between measurements of ipsilateral capitellum and prosthetic radial head size</article-title>. <source>J. Orthop. Surg. Res.</source> <volume>17</volume> (<issue>1</issue>), <fpage>496</fpage>. <pub-id pub-id-type="doi">10.1186/s13018-022-03393-x</pub-id>
</citation>
</ref>
<ref id="B24">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Tarallo</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Mugnai</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Rocchi</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Capra</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Catani</surname>
<given-names>F.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Comparison between absorbable pins and mini-screw fixations for the treatment of radial head fractures Mason type II-III</article-title>. <source>BMC Musculoskelet. Disord.</source> <volume>19</volume> (<issue>1</issue>), <fpage>94</fpage>. <pub-id pub-id-type="doi">10.1186/s12891-018-2014-x</pub-id>
</citation>
</ref>
<ref id="B25">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wagner</surname>
<given-names>F. C.</given-names>
</name>
<name>
<surname>Feucht</surname>
<given-names>M. J.</given-names>
</name>
<name>
<surname>Konstantinidis</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Hohloch</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Yilmaz</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Bernstein</surname>
<given-names>A.</given-names>
</name>
<etal/>
</person-group> (<year>2020</year>). <article-title>Biomechanical dynamic comparison of biodegradable pins and titanium screws for operative stabilization of displaced radial head fractures</article-title>. <source>Proc. Inst. Mech. Eng. H.</source> <volume>234</volume> (<issue>1</issue>), <fpage>74</fpage>&#x2013;<lpage>80</lpage>. <pub-id pub-id-type="doi">10.1177/0954411919884794</pub-id>
</citation>
</ref>
<ref id="B26">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wang</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Qi</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Shen</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Tao</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Liu</surname>
<given-names>Y.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Results of arthroscopic fixation of Mason type II radial head fractures using Kirschner wires</article-title>. <source>Medicine</source> <volume>97</volume> (<issue>12</issue>), <fpage>e0201</fpage>. <pub-id pub-id-type="doi">10.1097/md.0000000000010201</pub-id>
</citation>
</ref>
<ref id="B27">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wen</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Liu</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Ji</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>Z.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Effects of different surgical procedures on the therapeutic effects, prognosis, and major complications of acetabular fractures in the elderly of China: a systematic review and meta-analysis</article-title>. <source>Comput. Math. Methods Med.</source> <volume>2022</volume>, <fpage>1</fpage>&#x2013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1155/2022/9249920</pub-id>
</citation>
</ref>
<ref id="B28">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Xu</surname>
<given-names>G.-m.</given-names>
</name>
<name>
<surname>Liang</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Yang</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>J.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Finite element analysis of insertion angle of absorbable screws for the fixation of radial head fractures</article-title>. <source>Orthop. Surg.</source> <volume>12</volume> (<issue>6</issue>), <fpage>1710</fpage>&#x2013;<lpage>1717</lpage>. <pub-id pub-id-type="doi">10.1111/os.12797</pub-id>
</citation>
</ref>
<ref id="B29">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yang</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Zhuang</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Xiaosong</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Huasong</surname>
<given-names>W.</given-names>
</name>
</person-group> (<year>2023</year>). <article-title>Outcomes of radial head fractures treated with pre-curved metacarpal plate</article-title>. <source>BMC Musculoskelet. Disord.</source> <volume>24</volume> (<issue>1</issue>), <fpage>437</fpage>. <pub-id pub-id-type="doi">10.1186/s12891-023-06566-9</pub-id>
</citation>
</ref>
<ref id="B30">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yano</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Fukuda</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Uemura</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Kaneshiro</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Yamanaka</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Teraura</surname>
<given-names>H.</given-names>
</name>
<etal/>
</person-group> (<year>2023</year>). <article-title>Clinical results of surgical treatment for comminuted radial head and neck fracture: headless compression screws versus plate fixation</article-title>. <source>Indian J. Orthop.</source> <volume>57</volume> (<issue>2</issue>), <fpage>253</fpage>&#x2013;<lpage>261</lpage>. <pub-id pub-id-type="doi">10.1007/s43465-022-00792-4</pub-id>
</citation>
</ref>
<ref id="B31">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zarattini</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Galli</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Marchese</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Mascio</surname>
<given-names>L. D.</given-names>
</name>
<name>
<surname>Pazzaglia</surname>
<given-names>U. E.</given-names>
</name>
</person-group> (<year>2012</year>). <article-title>The surgical treatment of isolated Mason type 2 fractures of the radial head in adults: comparison between radial head resection and open reduction and internal fixation</article-title>. <source>J. Orthop. Trauma</source> <volume>26</volume> (<issue>4</issue>), <fpage>229</fpage>&#x2013;<lpage>235</lpage>. <pub-id pub-id-type="doi">10.1097/bot.0b013e318220a227</pub-id>
</citation>
</ref>
<ref id="B32">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhang</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Dyer</surname>
<given-names>G. S. M.</given-names>
</name>
<name>
<surname>Earp</surname>
<given-names>B. E.</given-names>
</name>
<name>
<surname>Blazar</surname>
<given-names>P.</given-names>
</name>
</person-group> (<year>2023</year>). <article-title>Complications, reoperations, and long-term outcomes after open reduction internal fixation of Mason classification type II and type III radial head fractures</article-title>. <source>J. Hand Microsurg</source> <volume>15</volume> (<issue>1</issue>), <fpage>045</fpage>&#x2013;<lpage>052</lpage>. <pub-id pub-id-type="doi">10.1055/s-0041-1724223</pub-id>
</citation>
</ref>
</ref-list>
</back>
</article>