<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article article-type="research-article" dtd-version="2.3" xml:lang="EN" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Bioeng. Biotechnol.</journal-id>
<journal-title>Frontiers in Bioengineering and Biotechnology</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Bioeng. Biotechnol.</abbrev-journal-title>
<issn pub-type="epub">2296-4185</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">1240125</article-id>
<article-id pub-id-type="doi">10.3389/fbioe.2023.1240125</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Bioengineering and Biotechnology</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Fatigue life of 3D-printed porous titanium dental implants predicted by validated finite element simulations</article-title>
<alt-title alt-title-type="left-running-head">Vautrin et al.</alt-title>
<alt-title alt-title-type="right-running-head">
<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3389/fbioe.2023.1240125">10.3389/fbioe.2023.1240125</ext-link>
</alt-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Vautrin</surname>
<given-names>Antoine</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/2332980/overview"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Aw</surname>
<given-names>Jensen</given-names>
</name>
<xref ref-type="aff" rid="aff3">
<sup>3</sup>
</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Attenborough</surname>
<given-names>Ed</given-names>
</name>
<xref ref-type="aff" rid="aff3">
<sup>3</sup>
</xref>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Varga</surname>
<given-names>Peter</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="corresp" rid="c001">&#x2a;</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1390261/overview"/>
</contrib>
</contrib-group>
<aff id="aff1">
<sup>1</sup>
<institution>AO Research Institute Davos</institution>, <addr-line>Davos</addr-line>, <country>Switzerland</country>
</aff>
<aff id="aff2">
<sup>2</sup>
<institution>Graduate School for Cellular and Biomedical Sciences</institution>, <institution>University of Bern</institution>, <addr-line>Bern</addr-line>, <country>Switzerland</country>
</aff>
<aff id="aff3">
<sup>3</sup>
<institution>Attenborough Dental Laboratories Ltd</institution>, <addr-line>Nottingham</addr-line>, <country>United Kingdom</country>
</aff>
<author-notes>
<fn fn-type="edited-by">
<p>
<bold>Edited by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/1372620/overview">Do-Gyoon Kim</ext-link>, The Ohio State University, United States</p>
</fn>
<fn fn-type="edited-by">
<p>
<bold>Reviewed by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/817127/overview">Maria Angeles Perez Anson</ext-link>, University of Zaragoza, Spain</p>
<p>
<ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/248605/overview">Naiara Rodriguez-Florez</ext-link>, University of Navarra, Spain</p>
</fn>
<corresp id="c001">&#x2a;Correspondence: Peter Varga, <email>peter.varga@aofoundation.org</email>
</corresp>
</author-notes>
<pub-date pub-type="epub">
<day>10</day>
<month>08</month>
<year>2023</year>
</pub-date>
<pub-date pub-type="collection">
<year>2023</year>
</pub-date>
<volume>11</volume>
<elocation-id>1240125</elocation-id>
<history>
<date date-type="received">
<day>14</day>
<month>06</month>
<year>2023</year>
</date>
<date date-type="accepted">
<day>27</day>
<month>07</month>
<year>2023</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#xa9; 2023 Vautrin, Aw, Attenborough and Varga.</copyright-statement>
<copyright-year>2023</copyright-year>
<copyright-holder>Vautrin, Aw, Attenborough and Varga</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p>
</license>
</permissions>
<abstract>
<p>
<bold>Introduction:</bold> Porous dental implants represent a promising strategy to reduce failure rate by favoring osseointegration or delivering drugs locally. Incorporating porous features weakens the mechanical capacity of an implant, but sufficient fatigue strength must be ensured as regulated in the ISO 14801 standard. Experimental fatigue testing is a costly and time-intensive part of the implant development process that could be accelerated with validated computer simulations. This study aimed at developing, calibrating, and validating a numerical workflow to predict fatigue strength on six porous configurations of a simplified implant geometry.</p>
<p>
<bold>Methods:</bold> Mechanical testing was performed on 3D-printed titanium samples to establish a direct link between endurance limit (i.e., infinite fatigue life) and monotonic load to failure, and a finite element model was developed and calibrated to predict the latter. The tool was then validated by predicting the fatigue life of a given porous configuration.</p>
<p>
<bold>Results:</bold> The normalized endurance limit (10% of the ultimate load) was the same for all six porous designs, indicating that monotonic testing was a good surrogate for endurance limit. The geometry input of the simulations influenced greatly their accuracy. Utilizing the as-designed model resulted in the highest prediction error (23%) and low correlation between the estimated and experimental loads to failure (R<sup>2</sup> &#x3d; 0.65). The prediction error was smaller when utilizing specimen geometry based on micro computed tomography scans (14%) or design models adjusted to match the printed porosity (8%).</p>
<p>
<bold>Discussion:</bold> The validated numerical workflow presented in this study could therefore be used to quantitatively predict the fatigue life of a porous implant, provided that the effect of manufacturing on implant geometry is accounted for.</p>
</abstract>
<kwd-group>
<kwd>dental implant</kwd>
<kwd>fatigue</kwd>
<kwd>porous titanium</kwd>
<kwd>additive manufacturing</kwd>
<kwd>finite element analysis</kwd>
<kwd>micro-CT</kwd>
</kwd-group>
<custom-meta-wrap>
<custom-meta>
<meta-name>section-at-acceptance</meta-name>
<meta-value>Biomechanics</meta-value>
</custom-meta>
</custom-meta-wrap>
</article-meta>
</front>
<body>
<sec id="s1">
<title>1 Introduction</title>
<p>Dental implants must sustain the mastication loads exerted on natural teeth. These repetitive forces can cause implant loosening or failure that require extraction and replacement of the defective implant. Peri-implantitis affects up to 20% of patients (<xref ref-type="bibr" rid="B22">Mombelli et al., 2012</xref>) and is a is a notable cause of implant failure. Peri-implantitis is characterized by an infection of the gingival soft tissue that can then propagate to bone and cause its resorption, which in turn increases the likelihood of mechanical implant failure. The long-term stability of dental implants is strongly determined by the osseointegration process. Formation of bone at the implant&#x2019;s surface results in establishing a load transfer mechanism between the implant and the surrounding bone (<xref ref-type="bibr" rid="B16">Li et al., 2020</xref>). Incorporating porosities in a dental implant increases the contact surface area with bone and thus represents a promising strategy to improve long-term stability. Bony ingrowth inside pores creates a mechanical interlocking between the two structures (<xref ref-type="bibr" rid="B24">Pa&#x142;ka and Pokrowiecki, 2018</xref>). Alternatively, the failure risk of dental implants can be reduced by using porous implants as drug-delivery devices: their pores can be loaded with antibiotics to treat locally infections such as peri-implantitis (<xref ref-type="bibr" rid="B6">De Cremer et al., 2017</xref>).</p>
<p>The production of complex implant geometries such as porous structures was enabled by the development of metal additive manufacturing (AM) (<xref ref-type="bibr" rid="B8">Hao et al., 2016</xref>). Titanium has been the predominantly used material for dental implants due to its advantageous properties in terms of biocompatibility, resistance to corrosion and osteoinductivity (<xref ref-type="bibr" rid="B9">Haugen and Chen, 2022</xref>). Titanium has also been used to develop porous scaffolds for dental and orthopaedic applications (<xref ref-type="bibr" rid="B20">Lv et al., 2021</xref>). The introduction of porosities in implants reduces mechanical strength relative to their solid counterparts and their mechanical behavior depends not only on the porosity level but also on the pore geometry (<xref ref-type="bibr" rid="B21">Maconachie et al., 2019</xref>; <xref ref-type="bibr" rid="B4">Chen et al., 2020</xref>). The mechanical properties of a wide range of porous configurations have been determined by testing scaffolds under both monotonic (<xref ref-type="bibr" rid="B32">Soro et al., 2019</xref>; <xref ref-type="bibr" rid="B39">Xiong et al., 2020</xref>) and fatigue loads (<xref ref-type="bibr" rid="B15">Li et al., 2016</xref>; <xref ref-type="bibr" rid="B5">Dallago et al., 2018</xref>; <xref ref-type="bibr" rid="B17">Lietaert, 2018</xref>).</p>
<p>Dental implants must comply with the ISO 14801 standard to ensure sufficient mechanical strength. This standard describes the mechanical testing procedure to determine endurance limit, i.e., the load level at which the implant has an infinite lifetime, i.e., it will not fail during its intended usage period. The prescribed bending-compression fatigue loading mode mimics the cyclically applied forces caused by mastication. However, a high number of samples (N &#x2265; 15) per design are required and the experiments are time-consuming with a single test lasting up to 4&#xa0;days. Although several studies have investigated the failure of conventional implants in this testing configuration (<xref ref-type="bibr" rid="B30">Shemtov-Yona and Rittel, 2014</xref>; <xref ref-type="bibr" rid="B31">Song et al., 2017</xref>; <xref ref-type="bibr" rid="B28">Rojo et al., 2018</xref>; <xref ref-type="bibr" rid="B37">Velasco-Ortega et al., 2019</xref>), only a few have focused on porous implants (<xref ref-type="bibr" rid="B38">Wang et al., 2019</xref>; <xref ref-type="bibr" rid="B36">Vanmunster et al., 2022</xref>; <xref ref-type="bibr" rid="B19">Lovera-Prado et al., 2023</xref>). Most studies investigating porous dental implants utilized monotonic tests in a variety of loading modes such as uniaxial compression, bending-compression, three-point bending and pull-out (<xref ref-type="bibr" rid="B3">Chakraborty et al., 2020</xref>; <xref ref-type="bibr" rid="B12">Huang et al., 2020</xref>). These tests have the advantage of being quicker than fatigue testing while allowing a qualitative comparison of different designs but may not be relevant for the fatigue failure required by the ISO 14801 standard.</p>
<p>The design process of implants is an iterative process requiring several prototypes. However, testing multiple porous configurations according to ISO 14801 is costly and time consuming and hence the appeal of developing alternative methods to quickly compare the fatigue life of multiple designs has arisen. Finite element (FE) modeling is a promising approach that meets this criterion and has been widely used to simulate the mechanical behavior of biomedical (<xref ref-type="bibr" rid="B33">Taylor and Prendergast, 2015</xref>; <xref ref-type="bibr" rid="B14">Lewis et al., 2021</xref>; <xref ref-type="bibr" rid="B25">Panagiotopoulou et al., 2021</xref>) and dental (<xref ref-type="bibr" rid="B34">Trivedi, 2014</xref>; <xref ref-type="bibr" rid="B27">Reddy et al., 2019</xref>) implants. Previous studies have utilized FE simulations to model ISO 14801 testing of conventional dental implants (<xref ref-type="bibr" rid="B26">Prados-Privado et al., 2018</xref>; <xref ref-type="bibr" rid="B13">Lee et al., 2021</xref>), but only a single study has modeled the ISO testing of a porous dental implant with a single pore design (<xref ref-type="bibr" rid="B38">Wang et al., 2019</xref>). The design process requires the evaluation of several configuration. Although the effect of unit cell geometry and porosity on the uniaxial fatigue strength of porous scaffolds has been studied both <italic>in vitro</italic> and <italic>in silico</italic> (<xref ref-type="bibr" rid="B43">Zheng et al., 2018</xref>; <xref ref-type="bibr" rid="B21">Maconachie et al., 2019</xref>; <xref ref-type="bibr" rid="B2">Benedetti et al., 2021</xref>), the impact of porous configuration has not been investigated for porous dental implants under bending-compression prescribed by the ISO 14801 standard. Therefore, the aim of this work is to develop, calibrate, and validate an FE-based tool to predict the fatigue life of 3D-printed porous titanium specimens mimicking dental implants.</p>
</sec>
<sec sec-type="materials|methods" id="s2">
<title>2 Materials and methods</title>
<p>We have established and validated a computational workflow to predict the endurance limit of porous specimens directly from their CAD models (<xref ref-type="fig" rid="F1">Figure 1</xref>). Specifically, the tool uses CAD-based FE models to predict the monotonic failure load for various pore types and porosities and, consecutively, the fatigue life (i.e., endurance limit) based on empirically established relationships.</p>
<fig id="F1" position="float">
<label>FIGURE 1</label>
<caption>
<p>FE-based workflow for fatigue life prediction consisting of two loops. The three constitutive relationships of the model (between fatigue loading and number of cycles to failure, between experimental and simulated ultimate monotonic load, and between CAD and printed geometries) were determined in the calibration loop by combining &#xb5;CT imaging, mechanical testing, and FE modeling. In the validation loop, the endurance limit of a separate set of designs was predicted using the calibrated models to assess the accuracy of the workflow.</p>
</caption>
<graphic xlink:href="fbioe-11-1240125-g001.tif"/>
</fig>
<p>Calibration of the tool was performed by establishing three relationships. First, the differences between planned CAD-based and printed geometries were evaluated with micro computed tomography (&#xb5;CT) image analysis and conversion rules were determined. Second, experimental testing was performed to establish the link between fatigue and monotonic behaviors. Lastly, FE simulations were performed to predict the ultimate load and correlate it with the experimental ultimate load. Calibration was achieved in a series of experiments involving four specimen groups of different pore types and porosities. The workflow was then validated on two other specimen groups with different porosities.</p>
<sec id="s2-1">
<title>2.1 Sample design and manufacturing</title>
<p>Simplified test samples mimicking dental implants were designed as 4.5&#xa0;mm-diameter cylinders that comply with the ISO 14801 requirements, i.e., the distance between the embedding plane and the center of the hemispherical tip being 11&#xa0;mm (BS EN ISO 14801 - 2016). In the hypothesis of a drug-delivery implant, the porous region should be placed close to the soft tissue, i.e., where an infection is most likely to happen. Hence, a fully porous section of 4.5&#xa0;mm height introduced around nominal bone level (<xref ref-type="fig" rid="F2">Figure 2A</xref>). Two unit cell geometries (skeletal Schwarz Primitive (SP) and Schwarz W (SW) (<xref ref-type="bibr" rid="B43">Zheng et al., 2018</xref>)) and three porosity levels (50%, 60% and 70%) were combined to generate six designs: 50SP, 60SP, 70SP, 50SW, 60SW and 70SW (<xref ref-type="fig" rid="F2">Figure 2B</xref>). The bulk part of the design was generated with Solidworks 2021 (Dassault Syst&#xe8;mes Simulia, Unites States) and then imported in Simpleware Scan IP (M-2017.06, Synopsys Inc., Unites States) to generate the porous section. The length of the unit cell was selected to fit an integer number of cells within the height of the pore region (4.5&#xa0;mm). Based on the findings of Zheng et al. showing that for equal unit cell lengths the pores of SP are two times larger and its struts 50% wider than the ones of SW (<xref ref-type="bibr" rid="B43">Zheng et al., 2018</xref>), a larger cell size was assigned to SW in order to reduce this difference (<xref ref-type="fig" rid="F2">Figure 2B</xref>). Two additional features were added: a ridge at embedding level and a protuberance at the top of the implant to ensure consistent height and rotation, respectively.</p>
<fig id="F2" position="float">
<label>FIGURE 2</label>
<caption>
<p>
<bold>(A)</bold> Porous sample geometry and <bold>(B)</bold> unit cell models of the six porous configurations manufactured by 3D printing.</p>
</caption>
<graphic xlink:href="fbioe-11-1240125-g002.tif"/>
</fig>
<p>A total number of 168 samples (28 per design) were additively manufactured via selective laser melting with Ti6Al4V powder (EOSINT M270, with printing parameters: 170&#xa0;W laser power, 1,250&#xa0;mm/s scanning speed and 0.03&#xa0;mm layer thickness). The predictive capability of the developed tool was assessed by dividing the into two groups: a calibration (60SP, 60SW, 70SP, 70SW) and a validation (50SP, 50SW) set (<xref ref-type="fig" rid="F2">Figure 2B</xref>).</p>
</sec>
<sec id="s2-2">
<title>2.2 &#xb5;CT imaging</title>
<p>Four samples of each design were scanned by &#xb5;CT with a voxel size of 10.5&#xa0;&#xb5;m (vivaCT 80, Scanco Medical AG, Switzerland) using a tube energy of 70&#xa0;kV and a current of 0.114&#xa0;mA. The implant was segmented in the &#xb5;CT images with a global threshold and exported as binary masks using Amira 3D 2021.2 (Thermo Fisher Scientific, Unites States). The effective printed porosity was computed in a 3&#xa0;mm &#xd7; 3&#xa0;mm x 3&#xa0;mm cubic ROI located in the center of the porous section with the BoneJ plugin (ImageJ 1.53d) (<xref ref-type="bibr" rid="B7">Doube et al., 2010</xref>; <xref ref-type="bibr" rid="B29">Schneider et al., 2012</xref>). The relationship between designed and printed porosities was determined for each unit cell assuming dependence of printability on cell geometry (<xref ref-type="bibr" rid="B21">Maconachie et al., 2019</xref>). This provided a pore shape specific correction factor that was utilized in the computational workflow. To compensate for printing inaccuracies, adjusted CAD models were generated by setting the porosity level of a CAD model to the one evaluated from the &#xb5;CT images.</p>
</sec>
<sec id="s2-3">
<title>2.3 Mechanical testing</title>
<p>The porous samples were tested in accordance with the ISO 14801 standard (<xref ref-type="fig" rid="F3">Figure 3A</xref>) under two loading types, monotonic and fatigue. The standard prescribes loading under bending compression at 30&#xb0; off-axis. Additional uniaxial tensile testing was performed on dog bone-shaped samples to determine the mechanical properties of the 3D-printed material.</p>
<fig id="F3" position="float">
<label>FIGURE 3</label>
<caption>
<p>Experimental and computational testing <bold>(A)</bold> description of the test setup based on BS EN ISO 14801; <bold>(B)</bold> experimental test setup used for monotonic and fatigue testing; <bold>(C)</bold> zoom-in view on the 60SP sample mounted in the testing machine; <bold>(D)</bold> representation of the FE model of the 60SP CAD geometry and boundary conditions replicating the experimental setup: blocked displacement under the embedding plane and load applied to the top of the sample at 30&#xb0; off-axis to the contact surface.</p>
</caption>
<graphic xlink:href="fbioe-11-1240125-g003.tif"/>
</fig>
<sec id="s2-3-1">
<title>2.3.1 Monotonic testing</title>
<p>Four samples per design (24 samples in total, including one &#xb5;CT-scanned specimen/design) were tested monotonically in ISO 14801 configuration under a quasi-static displacement rate of 0.4&#xa0;mm/min using an Instron 5866 testing machine (Instron, Unites States) equipped with a load cell having 10&#xa0;kN capacity. The force-displacement curve was recorded and the ultimate load (<inline-formula id="inf1">
<mml:math id="m1">
<mml:mrow>
<mml:msubsup>
<mml:mi>F</mml:mi>
<mml:mrow>
<mml:mi>u</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
<mml:mi mathvariant="italic">exp</mml:mi>
</mml:msubsup>
</mml:mrow>
</mml:math>
</inline-formula>) was determined as the maximum force reached throughout the test.</p>
</sec>
<sec id="s2-3-2">
<title>2.3.2 Fatigue testing</title>
<p>Fatigue loading was performed according to ISO 14801. The applied load was set to oscillate between 10% and 100% of the maximum load <inline-formula id="inf2">
<mml:math id="m2">
<mml:mrow>
<mml:msub>
<mml:mi>F</mml:mi>
<mml:mrow>
<mml:mi>c</mml:mi>
<mml:mi>y</mml:mi>
<mml:mi>c</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>i</mml:mi>
<mml:mi>c</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> at a frequency of 15&#xa0;Hz (DYNA5dent, DYNA-MESS Pr&#xfc;fsysteme GmbH, Germany). For each design, six load levels were defined as fractions of <inline-formula id="inf3">
<mml:math id="m3">
<mml:mrow>
<mml:msub>
<mml:mi>F</mml:mi>
<mml:mrow>
<mml:mi>u</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> and rounded to the nearest 10&#xa0;N: 50%, 35%, 25%, 20%, 15% and 10%. In total, 144 samples were tested in fatigue (24 samples/design, including three &#xb5;CT-scanned specimen/design, one for each of the highest load levels). Four samples of the same design were tested at each of the six load levels. Sample survival was defined in accordance with ISO 14801 as enduring five million loading cycles. In case the sample failed earlier, the number of cycles to failure (<inline-formula id="inf4">
<mml:math id="m4">
<mml:mrow>
<mml:msub>
<mml:mi>N</mml:mi>
<mml:mi>f</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>) was recorded.</p>
<p>Our workflow assumed that the relationship between the normalized fatigue load <inline-formula id="inf5">
<mml:math id="m5">
<mml:mrow>
<mml:msub>
<mml:mi>F</mml:mi>
<mml:mrow>
<mml:mi>c</mml:mi>
<mml:mi>y</mml:mi>
<mml:mi>c</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>i</mml:mi>
<mml:mi>c</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>/</mml:mo>
<mml:msubsup>
<mml:mi>F</mml:mi>
<mml:mrow>
<mml:mi>u</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
<mml:mi mathvariant="italic">exp</mml:mi>
</mml:msubsup>
</mml:mrow>
</mml:math>
</inline-formula> and <inline-formula id="inf6">
<mml:math id="m6">
<mml:mrow>
<mml:msub>
<mml:mi>N</mml:mi>
<mml:mi>f</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> was the same for all designs, i.e., that <inline-formula id="inf7">
<mml:math id="m7">
<mml:mrow>
<mml:msubsup>
<mml:mi>F</mml:mi>
<mml:mrow>
<mml:mi>u</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
<mml:mi mathvariant="italic">exp</mml:mi>
</mml:msubsup>
</mml:mrow>
</mml:math>
</inline-formula> was directly proportional to a design&#x2019;s fatigue behavior. The fatigue failures data for all designs was fitted with the following power law:<disp-formula id="e1">
<mml:math id="m8">
<mml:mrow>
<mml:msub>
<mml:mi>F</mml:mi>
<mml:mrow>
<mml:mi>c</mml:mi>
<mml:mi>y</mml:mi>
<mml:mi>c</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>i</mml:mi>
<mml:mi>c</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>/</mml:mo>
<mml:msubsup>
<mml:mi>F</mml:mi>
<mml:mrow>
<mml:mi>u</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
<mml:mi mathvariant="italic">exp</mml:mi>
</mml:msubsup>
<mml:mo>&#x3d;</mml:mo>
<mml:mi>a</mml:mi>
<mml:msup>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="|">
<mml:mrow>
<mml:msub>
<mml:mi>N</mml:mi>
<mml:mi>f</mml:mi>
</mml:msub>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:mi>b</mml:mi>
</mml:msup>
</mml:mrow>
</mml:math>
<label>(1)</label>
</disp-formula>with <italic>a</italic> and <italic>b</italic> being constants that were calibrated based on the experimental results of the calibration sample set. Moreover, it was assumed that the endurance limit could be estimated with this equation by calculating the fatigue load for <inline-formula id="inf8">
<mml:math id="m9">
<mml:mrow>
<mml:msub>
<mml:mi>N</mml:mi>
<mml:mi>f</mml:mi>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>5</mml:mn>
<mml:mo>.</mml:mo>
<mml:msup>
<mml:mn>10</mml:mn>
<mml:mn>6</mml:mn>
</mml:msup>
</mml:mrow>
</mml:math>
</inline-formula> cycles.</p>
</sec>
<sec id="s2-3-3">
<title>2.3.3 Uniaxial tensile testing</title>
<p>The elastic and plastic material properties of the 3D printed Ti6Al4V material were determined via uniaxial tensile testing based on the ISO 6892 standard (Instron 5866, Instron, Unites States) using six standard dog bone-shaped samples (cross section: 4&#xa0;mm &#xd7; 1.5 mm, total length: 70&#xa0;mm). Stress was computed by dividing the machine reaction force measured by the 10&#xa0;kN load cell (Instron) by the central cross-section, which was measured for each sample with a digital caliper. A stereographic optical tracking system (Aramis SRX, GOM GmbH, Germany) was used to track the displacement of two markers placed at both extremities of the middle section (<xref ref-type="fig" rid="F4">Figure 4</xref>). These two points act as a digital extensometer from which longitudinal strain was assessed by dividing the change in distance with the original length. The elastic modulus (E) was computed as the slope of the linear part of the stress-strain curve, i.e., between 0 and 400&#xa0;MPa, using linear regression analysis. The 0.2% plastic strain offset method was used to determine yield stress (&#x3c3;<sub>y</sub>). The ultimate tensile strength (UTS) and elongation at break (A%) were determined as the maximum stress and the strain values, respectively.</p>
<fig id="F4" position="float">
<label>FIGURE 4</label>
<caption>
<p>Tensile testing setup captured by the Aramis tracking system. The green line corresponds to the landmarks-based extensometer.</p>
</caption>
<graphic xlink:href="fbioe-11-1240125-g004.tif"/>
</fig>
</sec>
</sec>
<sec id="s2-4">
<title>2.4 FE simulations</title>
<sec id="s2-4-1">
<title>2.4.1 Model geometry and material properties</title>
<p>Linear elastic FE models were built for each sample design. To investigate the effect of printing inaccuracies and to define an approach to compensate for these, three different strategies were implemented for defining the model geometries from three different data sources and types: the original CAD model, and the masks generated from the segmented &#xb5;CT image and the adjusted CAD model matching the printed porosity level (<italic>cf.</italic> <xref ref-type="sec" rid="s2-2">section 2.2</xref>) (<xref ref-type="fig" rid="F5">Figure 5</xref>). These models were meshed in Simpleware with quadratic tetrahedral elements (C3D10). After performing a mesh convergence study, the element edge length was set to the range [0.15 mm; 0.4&#xa0;mm] for the whole model and was refined to 0.1&#xa0;mm for the porous region, with a resulting number of elements between 339,000 and 799,000.</p>
<fig id="F5" position="float">
<label>FIGURE 5</label>
<caption>
<p>FE mesh of the 60SP design (left) with zoomed sections of the porous part for the tree types of geometry used in the simulations: original CAD, &#xb5;CT-based and adjusted CAD (right).</p>
</caption>
<graphic xlink:href="fbioe-11-1240125-g005.tif"/>
</fig>
<p>An elasto-plastic material behavior law was assigned to titanium with linear elasticity and isotropic plasticity. The material properties determined by uniaxial tensile testing (E &#x3d; 104.8 GPa, &#x3c3;<sub>y</sub> &#x3d; 820.6 MPa, UTS &#x3d; 914.6 MPa, A% &#x3d; 4.41%, see <xref ref-type="sec" rid="s3-2-3">section 3.2.3</xref>) were implemented here and a Poisson&#x2019;s coefficient of 0.3 was used.</p>
</sec>
<sec id="s2-4-2">
<title>2.4.2 Loading and boundary conditions</title>
<p>The loading conditions were set to mimic the experimental conditions reproducing the ISO standard. The displacement of all nodes located below the embedding plane was constrained in all directions and loading was applied at 30&#xb0; off-axis direction (<xref ref-type="fig" rid="F3">Figure 3D</xref>). A single concentrated force was applied to a virtual node located at the loading point that was kinematically coupled to all surface nodes of the hemispherical head within a radius of 1&#xa0;mm to apply the load evenly on the contact surface.</p>
</sec>
<sec id="s2-4-3">
<title>2.4.3 Ultimate load determination</title>
<p>The FE simulations aimed to determine the ultimate state and the corresponding force level (<inline-formula id="inf9">
<mml:math id="m10">
<mml:mrow>
<mml:msubsup>
<mml:mi>F</mml:mi>
<mml:mrow>
<mml:mi>u</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mi>F</mml:mi>
<mml:mi>E</mml:mi>
</mml:mrow>
</mml:msubsup>
</mml:mrow>
</mml:math>
</inline-formula>). Six models were simulated for each design: the original CAD-based, the adjusted CAD-based and four &#xb5;CT-based models representing the four scanned samples. The analyses were performed with the standard solver of Abaqus 2021 (Dassault Syst&#xe8;mes, Simulia, Unites States) by applying a load magnitude of 1000&#xa0;N to ensure that the ultimate state was reached. The FE simulation results were post-processed by extracting the load-displacement curves at the load application node. <inline-formula id="inf10">
<mml:math id="m11">
<mml:mrow>
<mml:msubsup>
<mml:mi>F</mml:mi>
<mml:mrow>
<mml:mi>u</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mi>F</mml:mi>
<mml:mi>E</mml:mi>
</mml:mrow>
</mml:msubsup>
</mml:mrow>
</mml:math>
</inline-formula> was determined on the force-displacement curves using the secant method using a displacement offset. The plastic displacement (<inline-formula id="inf11">
<mml:math id="m12">
<mml:mrow>
<mml:msup>
<mml:mi>u</mml:mi>
<mml:mrow>
<mml:mi>p</mml:mi>
<mml:mi>l</mml:mi>
</mml:mrow>
</mml:msup>
</mml:mrow>
</mml:math>
</inline-formula>) was computed as follows:<disp-formula id="e2">
<mml:math id="m13">
<mml:mrow>
<mml:msup>
<mml:mi>u</mml:mi>
<mml:mrow>
<mml:mi>p</mml:mi>
<mml:mi>l</mml:mi>
</mml:mrow>
</mml:msup>
<mml:mo>&#x3d;</mml:mo>
<mml:mi>u</mml:mi>
<mml:mo>&#x2212;</mml:mo>
<mml:mi>F</mml:mi>
<mml:mo>/</mml:mo>
<mml:mi>k</mml:mi>
</mml:mrow>
</mml:math>
<label>(2)</label>
</disp-formula>with <inline-formula id="inf12">
<mml:math id="m14">
<mml:mrow>
<mml:mi>u</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> being the displacement of the node where the force was applied in mm, <inline-formula id="inf13">
<mml:math id="m15">
<mml:mrow>
<mml:mi>F</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> the applied load in N and <inline-formula id="inf14">
<mml:math id="m16">
<mml:mrow>
<mml:mi>k</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> the elastic stiffness of the sample in N/mm. Here, it was assumed that failure occurred at the same plastic displacement offset <inline-formula id="inf15">
<mml:math id="m17">
<mml:mrow>
<mml:msubsup>
<mml:mi>u</mml:mi>
<mml:mrow>
<mml:mi>u</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mi>p</mml:mi>
<mml:mi>l</mml:mi>
</mml:mrow>
</mml:msubsup>
</mml:mrow>
</mml:math>
</inline-formula> for all designs. This threshold value was identified in a parametric sub-study providing the strongest correlation between <inline-formula id="inf16">
<mml:math id="m18">
<mml:mrow>
<mml:msubsup>
<mml:mi>F</mml:mi>
<mml:mrow>
<mml:mi>u</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mi>F</mml:mi>
<mml:mi>E</mml:mi>
</mml:mrow>
</mml:msubsup>
</mml:mrow>
</mml:math>
</inline-formula> of the &#xb5;CT-based models and <inline-formula id="inf17">
<mml:math id="m19">
<mml:mrow>
<mml:msubsup>
<mml:mi>F</mml:mi>
<mml:mrow>
<mml:mi>u</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
<mml:mi mathvariant="italic">exp</mml:mi>
</mml:msubsup>
</mml:mrow>
</mml:math>
</inline-formula> for the calibration set.</p>
</sec>
<sec id="s2-4-4">
<title>2.4.4 Endurance limit prediction and model validation</title>
<p>The FE-based ultimate load <inline-formula id="inf18">
<mml:math id="m20">
<mml:mrow>
<mml:msubsup>
<mml:mi>F</mml:mi>
<mml:mrow>
<mml:mi>u</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mi>F</mml:mi>
<mml:mi>E</mml:mi>
</mml:mrow>
</mml:msubsup>
</mml:mrow>
</mml:math>
</inline-formula> that then was correlated with the experimental ultimate force data with the following equation:<disp-formula id="e3">
<mml:math id="m21">
<mml:mrow>
<mml:msubsup>
<mml:mi>F</mml:mi>
<mml:mrow>
<mml:mi>u</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
<mml:mi mathvariant="italic">exp</mml:mi>
</mml:msubsup>
<mml:mo>&#x3d;</mml:mo>
<mml:mi>c</mml:mi>
<mml:mo>&#x2219;</mml:mo>
<mml:msubsup>
<mml:mi>F</mml:mi>
<mml:mrow>
<mml:mi>u</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mi>F</mml:mi>
<mml:mi>E</mml:mi>
</mml:mrow>
</mml:msubsup>
<mml:mo>&#x2b;</mml:mo>
<mml:mi>d</mml:mi>
</mml:mrow>
</mml:math>
<label>(3)</label>
</disp-formula>with c and d being pore type specific constants. The FE-based fatigue life prediction expressed by combining the relationships between the results of fatigue and monotonic testing (Eq. <xref ref-type="disp-formula" rid="e1">1</xref>) as well as between monotonic testing and FE simulations (Eq. <xref ref-type="disp-formula" rid="e3">3</xref>) is as follows:<disp-formula id="e4">
<mml:math id="m22">
<mml:mrow>
<mml:msub>
<mml:mi>F</mml:mi>
<mml:mrow>
<mml:mi>c</mml:mi>
<mml:mi>y</mml:mi>
<mml:mi>c</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>i</mml:mi>
<mml:mi>c</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mi>a</mml:mi>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="|">
<mml:mrow>
<mml:mi>c</mml:mi>
<mml:mo>&#x2219;</mml:mo>
<mml:msubsup>
<mml:mi>F</mml:mi>
<mml:mrow>
<mml:mi>u</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mi>F</mml:mi>
<mml:mi>E</mml:mi>
</mml:mrow>
</mml:msubsup>
<mml:mo>&#x2b;</mml:mo>
<mml:mi>d</mml:mi>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:msup>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="|">
<mml:mrow>
<mml:msub>
<mml:mi>N</mml:mi>
<mml:mi>f</mml:mi>
</mml:msub>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:mi>b</mml:mi>
</mml:msup>
</mml:mrow>
</mml:math>
<label>(4)</label>
</disp-formula>
</p>
<p>Three parameters of this equation (<inline-formula id="inf19">
<mml:math id="m23">
<mml:mrow>
<mml:mi>c</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula>, <inline-formula id="inf20">
<mml:math id="m24">
<mml:mrow>
<mml:mi>d</mml:mi>
</mml:mrow>
</mml:math>
</inline-formula> and <inline-formula id="inf21">
<mml:math id="m25">
<mml:mrow>
<mml:msubsup>
<mml:mi>u</mml:mi>
<mml:mrow>
<mml:mi>u</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mi>p</mml:mi>
<mml:mi>l</mml:mi>
</mml:mrow>
</mml:msubsup>
</mml:mrow>
</mml:math>
</inline-formula>) were calibrated with the experiments and simulations performed on the four designs of the calibration set (70SW, 70SP, 60SW, 60SP) (<xref ref-type="fig" rid="F1">Figure 1</xref>). Finally, model validation was performed for each geometry type (CAD-based, &#xb5;CT-based and adjusted CAD-based) by predicting the ultimate loads of the designs of the validation set (50SW, 50SP) via FE simulations. The endurance limits were computed according to Eq. <xref ref-type="disp-formula" rid="e4">4</xref> and compared with the corresponding experimental results to benchmark the different geometry types.</p>
</sec>
</sec>
<sec id="s2-5">
<title>2.5 Statistical analysis</title>
<p>The predictive capability of each model type was assessed using linear regression analysis on the calibration dataset to compare the FE-based and experimental ultimate loads. The Pearsons&#x2019;s correlation coefficient (R<sup>2</sup>) values and <italic>p</italic>-values were used as measures of predictive performance and statistical significance, respectively. The significance level was set at 0.05.</p>
</sec>
</sec>
<sec sec-type="results" id="s3">
<title>3 Results</title>
<sec id="s3-1">
<title>3.1 &#xb5;CT imaging</title>
<p>For all six pore geometries, the &#xb5;CT-based printed porosity was lower compared to the original CAD-based planned porosity due to additional material sintered during manufacturing (<xref ref-type="fig" rid="F6">Figure 6A</xref>). This difference varied between the cell types, with approximately 4% of extra material for SP and 16% for SW designs. Cell-specific correlations were established based on the calibration dataset and were used to estimate the adjusted geometries of the validation designs. These predictions provided less than 1% error when compared to the &#xb5;CT-based values of the validation specimens (<xref ref-type="fig" rid="F6">Figure 6B</xref>), indicating consistent relationship for a given pore cell type. The adjusted versions of the CAD models were generated to match these &#xb5;CT-based porosity magnitudes. For instance, an adjusted CAD model with 64% porosity was generated to replicate the printed porosity of design 70SP.</p>
<fig id="F6" position="float">
<label>FIGURE 6</label>
<caption>
<p>
<bold>(A)</bold> &#xb5;CT cross-section of a 60SP sample in grayscales with the CAD model overlayed with red hatches. <bold>(B)</bold> Relationship between the porosities of the original CAD models and the 3D-printed samples determined by &#xb5;CT imaging. Unit cell type-wise linear regressions performed on the calibration dataset (circles) provided accurate predictions for the validation designs (crosses).</p>
</caption>
<graphic xlink:href="fbioe-11-1240125-g006.tif"/>
</fig>
</sec>
<sec id="s3-2">
<title>3.2 Mechanical testing</title>
<sec id="s3-2-1">
<title>3.2.1 Monotonic testing</title>
<p>The monotonic ultimate load results showed strong dependency on porosity, with a 10% decrease of porosity corresponding to an approximately 200&#xa0;N increase of ultimate load (<xref ref-type="fig" rid="F7">Figure 7</xref>). These trends were similar for the two different unit cell types SP and SW.</p>
<fig id="F7" position="float">
<label>FIGURE 7</label>
<caption>
<p>Ultimate load levels measured for each porous configuration. the solid and hatched bars indicate the calibration and validation designs, respectively. Error bars indicate 95% confidence interval.</p>
</caption>
<graphic xlink:href="fbioe-11-1240125-g007.tif"/>
</fig>
</sec>
<sec id="s3-2-2">
<title>3.2.2 Fatigue testing</title>
<p>The absolute fatigue load magnitudes plotted against the number of cycles to failure showed a wide spread for the different designs (<xref ref-type="fig" rid="F8">Figure 8A</xref>), confirming the validity of the underlying assumption. This scatter was considerably reduced when normalizing the fatigue load magnitudes by the monotonic ultimate load values (<xref ref-type="fig" rid="F8">Figure 8B</xref>). For each design, all four samples of a given load level survived at the 10% of <inline-formula id="inf22">
<mml:math id="m26">
<mml:mrow>
<mml:msubsup>
<mml:mi>F</mml:mi>
<mml:mrow>
<mml:mi>u</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
<mml:mi mathvariant="italic">exp</mml:mi>
</mml:msubsup>
</mml:mrow>
</mml:math>
</inline-formula> while at least one of the four specimens failed at the 15% of <inline-formula id="inf23">
<mml:math id="m27">
<mml:mrow>
<mml:msubsup>
<mml:mi>F</mml:mi>
<mml:mrow>
<mml:mi>u</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
<mml:mi mathvariant="italic">exp</mml:mi>
</mml:msubsup>
</mml:mrow>
</mml:math>
</inline-formula>. The normalized endurance limit is therefore comprised in the 10%&#x2013;15% interval. Fitting Eq. <xref ref-type="disp-formula" rid="e1">1</xref> to the samples of the calibration sets with <inline-formula id="inf24">
<mml:math id="m28">
<mml:mrow>
<mml:msub>
<mml:mi>N</mml:mi>
<mml:mi>f</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> &#x3c; 5 million cycles provided a &#x3d; 3.22 and b &#x3d; &#x2212;0.20. This relationship was found to be consistent with the results of the validation set (<xref ref-type="fig" rid="F8">Figure 8C</xref>), corroborating the appropriateness of this approach and the determined parameters. The endurance limit at 5 million cycles estimated by this relationship was equal to 12.86% of <inline-formula id="inf25">
<mml:math id="m29">
<mml:mrow>
<mml:msubsup>
<mml:mi>F</mml:mi>
<mml:mrow>
<mml:mi>u</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
<mml:mi mathvariant="italic">exp</mml:mi>
</mml:msubsup>
</mml:mrow>
</mml:math>
</inline-formula>, with a 95% confidence interval of [10.06%, 16.43%]. These values were consistent with the 10%&#x2013;15% interval determined based on survivals. The sample survivals of the validation set were also within this confidence interval (<xref ref-type="fig" rid="F8">Figure 8C</xref>).</p>
<fig id="F8" position="float">
<label>FIGURE 8</label>
<caption>
<p>Results of the fatigue failure tests. <bold>(A)</bold> Absolute fatigue load magnitude <italic>versus</italic> cycles to failure for all six pore configurations. <bold>(B)</bold> and <bold>(C)</bold> Same data with the fatigue load normalized to the monotonic ultimate load for the calibration <bold>(B)</bold> and validation <bold>(C)</bold> sample sets. The power law fitted on the calibration dataset is represented as a solid line with the dotted lines being its 95% confidence interval.</p>
</caption>
<graphic xlink:href="fbioe-11-1240125-g008.tif"/>
</fig>
</sec>
<sec id="s3-2-3">
<title>3.2.3 Uniaxial tensile testing</title>
<p>The following elastic and plastic material properties of the 3D-printed titanium were determined by uniaxial tensile testing of dog bone shaped specimens: E &#x3d; 104.8&#xa0;GPa (standard deviation (SD): 3.7&#xa0;GPa), &#x3c3;<sub>y</sub> &#x3d; 820.6&#xa0;MPa (SD: 6.0&#xa0;MPa), UTS &#x3d; 914.6&#xa0;MPa (SD: 16.3&#xa0;MPa) and A% &#x3d; 4.41% (SD: 1.33%). The mean values of these properties were used as material parameter input in the FE models.</p>
</sec>
</sec>
<sec id="s3-3">
<title>3.3 FE simulations</title>
<p>The best correlation (R<sup>2</sup> &#x3d; 0.98) between experimental monotonic ultimate load and FE-predicted ultimate load using the &#xb5;CT-based models was found for <inline-formula id="inf26">
<mml:math id="m30">
<mml:mrow>
<mml:msubsup>
<mml:mi>u</mml:mi>
<mml:mrow>
<mml:mi>u</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mi>p</mml:mi>
<mml:mi>l</mml:mi>
</mml:mrow>
</mml:msubsup>
</mml:mrow>
</mml:math>
</inline-formula> &#x3d; 0.07&#xa0;mm. Using this evaluation offset value, a high correlation was observed also for the adjusted CAD-based models (R<sup>2</sup> &#x3d; 0.99). These two model types possessed significant correlations (<italic>p</italic> &#x3c; 0.001), contrarily to the original non-adjusted CAD-based ones (<italic>p</italic> &#x3d; 0.12 and R<sup>2</sup> &#x3d; 0.65, <xref ref-type="fig" rid="F9">Figure 9</xref>). Using this approach, good prediction of the experimental monotonic ultimate load could be achieved for the validation set (<xref ref-type="fig" rid="F9">Figure 9</xref>).</p>
<fig id="F9" position="float">
<label>FIGURE 9</label>
<caption>
<p>Comparison of the experimental ultimate load with the FE-predicted ultimate load for the three different model geometries (&#xb5;CT, adjusted CAD and original CAD), with the latter determined using a plastic displacement offset set at 0.07&#xa0;mm. The dotted lines represent the linear regression determined on the calibration dataset (circles), indicating good fit for the validation set (crosses) for the adjusted CAD approach.</p>
</caption>
<graphic xlink:href="fbioe-11-1240125-g009.tif"/>
</fig>
</sec>
<sec id="s3-4">
<title>3.4 Endurance limit prediction</title>
<p>For both validation designs 50SW and 50 SP, the FE-based endurance limit predictions were within the 10%&#x2013;15% <inline-formula id="inf27">
<mml:math id="m31">
<mml:mrow>
<mml:msub>
<mml:mi>F</mml:mi>
<mml:mrow>
<mml:mi>u</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> range determined experimentally (<xref ref-type="fig" rid="F10">Figure 10</xref>), confirming the validity of the developed and calibrated simulation workflow. Since the specific aim of FE modeling in this workflow was to predict the ultimate load, its accuracy must be assessed relatively to the experimental monotonic test results. In this regard, models with the adjusted CAD-based geometry provided the most consistent estimations of experimental monotonic ultimate load for the two designs of the validation set (50SP and 50SW) with a maximum relative error of 8%. In comparison, the maximum error of the models with the original CAD based and &#xb5;CT geometry were 23% and 15.3%, respectively.</p>
<fig id="F10" position="float">
<label>FIGURE 10</label>
<caption>
<p>FE-based predictions of monotonic ultimate load (left) and fatigue endurance limit (right) compared with the corrsponding experimental results (pink bar: monotonic ultimate load; dotted lines: endurance limit, comprised between 10% and 15% of <inline-formula id="inf28">
<mml:math id="m32">
<mml:mrow>
<mml:msub>
<mml:mi mathvariant="bold-italic">F</mml:mi>
<mml:mrow>
<mml:mi mathvariant="bold-italic">u</mml:mi>
<mml:mi mathvariant="bold-italic">l</mml:mi>
<mml:mi mathvariant="bold-italic">t</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>). The error bars represent the 95% confidence intervals computed either on the four samples tested monotonically (monotonic testing) or on the four &#xb5;CT-based FE results (FE - &#xb5;CT).</p>
</caption>
<graphic xlink:href="fbioe-11-1240125-g010.tif"/>
</fig>
</sec>
</sec>
<sec sec-type="discussion" id="s4">
<title>4 Discussion</title>
<p>The FE simulation approach developed and calibrated in this study was found to accurately predict an implant design&#x2019;s infinite fatigue life for a validation set having different porous configurations. This prediction tool can be an efficient surrogate for time consuming fatigue testing directly based on CAD models and therefore accelerate the development process of porous implants. This approach can also be utilized as a benchmark to evaluate the fatigue strength of different porous configurations under bending-compression loading corresponding to the ISO 14081 standard.</p>
<p>Another finding of this study was that monotonic testing appeared to be a good surrogate of fatigue testing. The normalized fatigue life curves (<xref ref-type="fig" rid="F8">Figures 8B,C</xref>) were consistent for all designs and, most importantly, the endurance limits were reached at the same normalized load level range of 10%&#x2013;15% of <inline-formula id="inf29">
<mml:math id="m33">
<mml:mrow>
<mml:msub>
<mml:mi>F</mml:mi>
<mml:mrow>
<mml:mi>u</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>. From an implant development perspective, this result shows the potential of monotonic testing to be used for rapid screening of several designs, enabling the selection of the most promising designs to be tested cyclically, reducing the number of time-consuming fatigue tests.</p>
<p>The normalized endurance limit determined in this work was significantly lower than that of solid titanium (<inline-formula id="inf30">
<mml:math id="m34">
<mml:mrow>
<mml:msub>
<mml:mi>&#x3c3;</mml:mi>
<mml:mi>e</mml:mi>
</mml:msub>
<mml:mo>/</mml:mo>
<mml:msub>
<mml:mi>&#x3c3;</mml:mi>
<mml:mi>y</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> &#x2248; 40%) (<xref ref-type="bibr" rid="B1">Amin Yavari et al., 2013</xref>). This discrepancy was most probably caused by manufacturing imperfections such as surface roughness and irregular strut thicknesses where fatigue crack initiation is more likely to occur (<xref ref-type="bibr" rid="B5">Dallago et al., 2018</xref>; <xref ref-type="bibr" rid="B2">Benedetti et al., 2021</xref>). Several studies reported that porous titanium structures have a lower fatigue resistance than solid titanium. Vanmunster et al. tested a porous dental implant under ISO 14801 conditions and reported an endurance limit equal to 14.7% of <inline-formula id="inf31">
<mml:math id="m35">
<mml:mrow>
<mml:msub>
<mml:mi>F</mml:mi>
<mml:mrow>
<mml:mi>u</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula> (<xref ref-type="bibr" rid="B36">Vanmunster et al., 2022</xref>). Both Lietaert et al. and Amin Yavari et al. determined the S-N curves of porous cylinders under uniaxial compressive loading (<xref ref-type="bibr" rid="B1">Amin Yavari et al., 2013</xref>; <xref ref-type="bibr" rid="B17">Lietaert, 2018</xref>). Extrapolating the fatigue failure relationships reported by them to 5 million cycles results in fatigue limits (<inline-formula id="inf32">
<mml:math id="m36">
<mml:mrow>
<mml:msub>
<mml:mi>&#x3c3;</mml:mi>
<mml:mi>e</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>) of 7.7% and 16.4% of <inline-formula id="inf33">
<mml:math id="m37">
<mml:mrow>
<mml:msub>
<mml:mi>&#x3c3;</mml:mi>
<mml:mi>y</mml:mi>
</mml:msub>
</mml:mrow>
</mml:math>
</inline-formula>, respectively. These values are consistent with the normalized endurance limit determined in the present work.</p>
<p>The fact that the experimental ultimate monotonic load was found in this study to be a good surrogate of endurance limit supports our initial choice to simulate the monotonic test with the FE models. With this approach, only one parameter (<inline-formula id="inf34">
<mml:math id="m38">
<mml:mrow>
<mml:msubsup>
<mml:mi>u</mml:mi>
<mml:mrow>
<mml:mi>u</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
<mml:mrow>
<mml:mi>p</mml:mi>
<mml:mi>l</mml:mi>
</mml:mrow>
</mml:msubsup>
</mml:mrow>
</mml:math>
</inline-formula>) was needed to be calibrated experimentally. Modeling the fatigue behavior would have presented the advantage of establishing a direct link between the simulations and the experimental fatigue behavior. The feasibility of this approach was demonstrated by the implementation of fatigue algorithms for porous cylinders (<xref ref-type="bibr" rid="B10">Hedayati et al., 2016</xref>; <xref ref-type="bibr" rid="B41">Zargarian et al., 2016</xref>) and conventional dental implants (<xref ref-type="bibr" rid="B35">Tsai et al., 2013</xref>; <xref ref-type="bibr" rid="B26">Prados-Privado et al., 2018</xref>; <xref ref-type="bibr" rid="B13">Lee et al., 2021</xref>). However, implementing this was beyond the scope of the present study since, among other challenges, characterizing the fatigue properties of the printed material would have been necessary and the complexity of the model would have increased. Similarly to the present study (<xref ref-type="bibr" rid="B38">Wang et al., 2019</xref>), combined ISO 14801 experimental testing of a porous dental implant with FE modelling. They simulated an implant integrated in a mandibular cross-section and loaded monotonically 30&#xb0; off-axis. This configuration did not reproduce accurately the experimental test but allowed a qualitative comparison, with their porous implant showing higher stress levels <italic>in silico</italic> and a shorter fatigue life <italic>in vitro</italic> than the solid one.</p>
<p>Three strategies that were employed in this study to define the FE geometry for each design. Utilizing the original CAD design is generally the most convenient approach since it does not require any additional characterization of the printed samples. Hence, most <italic>in silico</italic> studies modelled porous dental implants with as-designed CAD geometries (<xref ref-type="bibr" rid="B38">Wang et al., 2019</xref>; <xref ref-type="bibr" rid="B12">Huang et al., 2020</xref>; <xref ref-type="bibr" rid="B42">Zhang et al., 2020</xref>). The ultimate loads computed with this method, however, did not correlate significantly (<italic>p</italic> &#x3d; 0.12) with the experimental results (<xref ref-type="fig" rid="F9">Figure 9</xref>). In addition, the worst prediction was achieved with this geometry during model validation, with the ultimate load of 50SW being underestimated by 23% (<xref ref-type="fig" rid="F10">Figure 10</xref>). This discrepancy may be explained by the different printability of the two unit cell types. The &#xb5;CT analysis revealed that the printed porosities were lower than for the CAD-based planned geometries, by approximately 4% for SP and 16% for SW. For the same CAD-based planned porosity, <inline-formula id="inf35">
<mml:math id="m39">
<mml:mrow>
<mml:msubsup>
<mml:mi>F</mml:mi>
<mml:mrow>
<mml:mi>u</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>t</mml:mi>
</mml:mrow>
<mml:mi mathvariant="italic">exp</mml:mi>
</mml:msubsup>
</mml:mrow>
</mml:math>
</inline-formula> was higher for SP than for SW (<xref ref-type="fig" rid="F7">Figure 7</xref>), confirming the contribution of the extra printed material to the mechanical strength of the resulting. porosity shows that SP has a higher strength. Thus, 50SP and 60SW have similar printed porosities (<xref ref-type="fig" rid="F6">Figures 6&#x2013;b</xref>) but the ultimate load of 50SP is superior by 60%.</p>
<p>The &#xb5;CT-based modeling approach provided predictions that correlated well with experimental data (R<sup>2</sup> &#x3d; 0.98) since it incorporated the real geometry of the samples. Simulating four scanned samples per design showed reasonably small variability of the estimated ultimate loads (<xref ref-type="fig" rid="F9">Figure 9</xref>). These models took into account manufacturing irregularities that reduce the mechanical strength of porous titanium scaffolds as highlighted by <xref ref-type="bibr" rid="B18">Liu et al. (2017)</xref>. For example, stress concentrations can be caused by an irregular strut thickness, while aggregates of partially fused particles on the surface contribute less to structural stiffness (<xref ref-type="fig" rid="F6">Figure 6A</xref>). However, this approach cannot be used in the optimization workflow in a prospective manner aiming to predict the endurance limit of new porous configurations without the necessity of manufacturing. Adjusting the CAD geometry provided a good compromise between the exact representation of the printed geometry and a CAD-generated geometry that is suitable for the purposes of a numerical predictive workflow. For all designs, adjusted CAD-based FE models exhibited higher ultimate loads than &#xb5;CT-based ones, although these should be similar in the case of an ideal adjustment. This difference is most likely caused by the lack of irregularities of the adjusted CAD geometry. This optimal repartition of the same volume of material results in a higher predicted monotonic strength.</p>
<p>This study has a number of limitations that should be addressed. First, this workflow was able to predict the endurance limit for porous configuration variations, but its validity was not assessed for other design features such as the overall dimensions of the implant (diameter, length) or the position and shape of the porous region. The fatigue strength of an implant could, for example be enhanced by adding solid elements to stiffen structure. Such approach was adopted by (<xref ref-type="bibr" rid="B39">Xiong et al., 2020</xref>), who optimized the strength of a porous implant in uniaxial compression by varying the diameter of a solid central rod. Adapting the method developed here to a full implant design may require a partial recalibration of some parameters, e.g., the plastic failure displacement. The monotonic failure criterion was defined here based on displacement and not stress. A stress-based failure criterion would be independent from the global sample geometry and would consist in predicting strut failure. However, Benedetti et al. reported that the failure mode of a porous structure was dependent of unit cell topology and can result in different degrees of ductility (<xref ref-type="bibr" rid="B2">Benedetti et al., 2021</xref>). Lastly, the scope of ISO 14801 limits the pore locations that can be investigated with the current method. The part of the sample starting 3&#xa0;mm below nominal bone level and therefore all implant features below the embedding plane are not considered in these tests. Since the purpose of porous dental implants is primarily to increase osseointegration, many designs reported in the literature (<xref ref-type="bibr" rid="B23">Obaton et al., 2017</xref>; <xref ref-type="bibr" rid="B40">Yang et al., 2017</xref>; <xref ref-type="bibr" rid="B11">Hong et al., 2020</xref>) incorporate pores located in this &#x201c;blind spot&#x201d;. As such, alternative methods have been employed to test these designs, either experimentally (e.g., three point bending, uniaxial compression) (<xref ref-type="bibr" rid="B3">Chakraborty et al., 2020</xref>; <xref ref-type="bibr" rid="B12">Huang et al., 2020</xref>; <xref ref-type="bibr" rid="B39">Xiong et al., 2020</xref>), or numerically (e.g., simulating the implant&#x2019;s behavior in bone) (<xref ref-type="bibr" rid="B18">Liu et al., 2017</xref>; <xref ref-type="bibr" rid="B42">Zhang et al., 2020</xref>).</p>
<p>In conclusion, a fatigue life prediction tool for porous dental implants was developed, calibrated, and validated in the present study possible by combining <italic>in vitro</italic> and <italic>in silico</italic> methods. Fatigue and monotonic mechanical testing were performed on six porous configurations of a simplified implant design. The monotonic failure load was found to be a good and efficient surrogate of the fatigue failure load, with the endurance limit of all designs being situated between 10% and 15% of the monotonic ultimate load. FE simulations predicted well the experimental monotonic test results when the model geometry was based on &#xb5;CT images, but not for as-designed CAD-based model geometries. This approach ignores the discrepancies between CAD and printed geometries. This limitation was resolved by utilizing CT-based geometry or by adjusting the porosity of the CAD model.</p>
</sec>
</body>
<back>
<sec sec-type="data-availability" id="s5">
<title>Data availability statement</title>
<p>The raw data supporting the conclusion of this article will be made available by the authors, without undue reservation, upon specific request.</p>
</sec>
<sec id="s6">
<title>Author contributions</title>
<p>All authors developed the study design. JA manufactured the samples. AV performed the CT scans and mechanical tests. AV developed the computational models. AV and PV interpreted the data and drafted the manuscript. All authors contributed to the article and approved the submitted version.</p>
</sec>
<sec id="s7">
<title>Funding</title>
<p>This project has received funding from the European Union&#x2019;s Horizon 2020 research and innovation programme under grant agreement No. 953128 (I&#x2010;SMarD).</p>
</sec>
<ack>
<p>We gratefully acknowledge the expert advice of Philippe Zysset.</p>
</ack>
<sec sec-type="COI-statement" id="s8">
<title>Conflict of interest</title>
<p>Authors JA and EA are employed by Attenborough Dental Laboratories Ltd.</p>
<p>The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec sec-type="disclaimer" id="s9">
<title>Publisher&#x2019;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<ref-list>
<title>References</title>
<ref id="B1">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Amin Yavari</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Wauthle</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>van der Stok</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Riemslag</surname>
<given-names>A. C.</given-names>
</name>
<name>
<surname>Janssen</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Mulier</surname>
<given-names>M.</given-names>
</name>
<etal/>
</person-group> (<year>2013</year>). <article-title>Fatigue behavior of porous biomaterials manufactured using selective laser melting</article-title>. <source>Mat. Sci. Eng. C</source> <volume>33</volume>, <fpage>4849</fpage>&#x2013;<lpage>4858</lpage>. <pub-id pub-id-type="doi">10.1016/j.msec.2013.08.006</pub-id>
</citation>
</ref>
<ref id="B2">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Benedetti</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Du Plessis</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Ritchie</surname>
<given-names>R. O.</given-names>
</name>
<name>
<surname>Dallago</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Razavi</surname>
<given-names>S. M. J.</given-names>
</name>
<name>
<surname>Berto</surname>
<given-names>F.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Architected cellular materials: a review on their mechanical properties towards fatigue-tolerant design and fabrication</article-title>. <source>Mat. Sci. Eng. R. Rep.</source> <volume>144</volume>, <fpage>100606</fpage>. <pub-id pub-id-type="doi">10.1016/j.mser.2021.100606</pub-id>
</citation>
</ref>
<ref id="B3">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Chakraborty</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Datta</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Majumder</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Mondal</surname>
<given-names>S. C.</given-names>
</name>
<name>
<surname>Roychowdhury</surname>
<given-names>A.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Finite element and experimental analysis to select patient&#x2019;s bone condition specific porous dental implant, fabricated using additive manufacturing</article-title>. <source>Comput. Biol. Med.</source> <volume>124</volume>, <fpage>103839</fpage>. <pub-id pub-id-type="doi">10.1016/j.compbiomed.2020.103839</pub-id>
</citation>
</ref>
<ref id="B4">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Chen</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Han</surname>
<given-names>Q.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Liu</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>J.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Porous scaffold design for additive manufacturing in orthopedics: a review</article-title>. <source>Front. Bioeng. Biotechnol.</source> <volume>8</volume>, <fpage>609</fpage>. <pub-id pub-id-type="doi">10.3389/fbioe.2020.00609</pub-id>
</citation>
</ref>
<ref id="B5">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Dallago</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Fontanari</surname>
<given-names>V.</given-names>
</name>
<name>
<surname>Torresani</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Leoni</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Pederzolli</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Potrich</surname>
<given-names>C.</given-names>
</name>
<etal/>
</person-group> (<year>2018</year>). <article-title>Fatigue and biological properties of Ti-6Al-4V ELI cellular structures with variously arranged cubic cells made by selective laser melting</article-title>. <source>J. Mech. Behav. Biomed. Mat.</source> <volume>78</volume>, <fpage>381</fpage>&#x2013;<lpage>394</lpage>. <pub-id pub-id-type="doi">10.1016/j.jmbbm.2017.11.044</pub-id>
</citation>
</ref>
<ref id="B6">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>De Cremer</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Braem</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Gerits</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>De Brucker</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Vandamme</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Martens</surname>
<given-names>J.</given-names>
</name>
<etal/>
</person-group> (<year>2017</year>). <article-title>Controlled release of chlorhexidine from a mesoporous silica-containing macroporous titanium dental implant prevents microbial biofilm formation</article-title>. <source>Eur. Cell. Mat.</source> <volume>33</volume>, <fpage>13</fpage>&#x2013;<lpage>27</lpage>. <pub-id pub-id-type="doi">10.22203/eCM.v033a02</pub-id>
</citation>
</ref>
<ref id="B7">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Doube</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>K&#x142;osowski</surname>
<given-names>M. M.</given-names>
</name>
<name>
<surname>Arganda-Carreras</surname>
<given-names>I.</given-names>
</name>
<name>
<surname>Cordeli&#xe8;res</surname>
<given-names>F. P.</given-names>
</name>
<name>
<surname>Dougherty</surname>
<given-names>R. P.</given-names>
</name>
<name>
<surname>Jackson</surname>
<given-names>J. S.</given-names>
</name>
<etal/>
</person-group> (<year>2010</year>). <article-title>BoneJ: free and extensible bone image analysis in ImageJ</article-title>. <source>Bone</source> <volume>47</volume>, <fpage>1076</fpage>&#x2013;<lpage>1079</lpage>. <pub-id pub-id-type="doi">10.1016/j.bone.2010.08.023</pub-id>
</citation>
</ref>
<ref id="B8">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hao</surname>
<given-names>Y.-L.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>S.-J.</given-names>
</name>
<name>
<surname>Yang</surname>
<given-names>R.</given-names>
</name>
</person-group> (<year>2016</year>). <article-title>Biomedical titanium alloys and their additive manufacturing</article-title>. <source>Rare Met.</source> <volume>35</volume>, <fpage>661</fpage>&#x2013;<lpage>671</lpage>. <pub-id pub-id-type="doi">10.1007/s12598-016-0793-5</pub-id>
</citation>
</ref>
<ref id="B9">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Haugen</surname>
<given-names>H. J.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>H.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Is there a better biomaterial for dental implants than titanium? a review and meta-study analysis</article-title>. <source>J. Funct. Biomater.</source> <volume>13</volume>, <fpage>46</fpage>. <pub-id pub-id-type="doi">10.3390/jfb13020046</pub-id>
</citation>
</ref>
<ref id="B10">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hedayati</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Hosseini-Toudeshky</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Sadighi</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Mohammadi-Aghdam</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Zadpoor</surname>
<given-names>A. A.</given-names>
</name>
</person-group> (<year>2016</year>). <article-title>Computational prediction of the fatigue behavior of additively manufactured porous metallic biomaterials</article-title>. <source>Int. J. Fatigue</source> <volume>84</volume>, <fpage>67</fpage>&#x2013;<lpage>79</lpage>. <pub-id pub-id-type="doi">10.1016/j.ijfatigue.2015.11.017</pub-id>
</citation>
</ref>
<ref id="B11">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hong</surname>
<given-names>J.-Y.</given-names>
</name>
<name>
<surname>Ko</surname>
<given-names>S.-Y.</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Chang</surname>
<given-names>Y.-Y.</given-names>
</name>
<name>
<surname>Kim</surname>
<given-names>S.-H.</given-names>
</name>
<name>
<surname>Yun</surname>
<given-names>J.-H.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Enhancement of bone ingrowth into a porous titanium structure to improve osseointegration of dental implants: a pilot study in the canine model</article-title>. <source>Materials</source> <volume>13</volume>, <fpage>3061</fpage>. <pub-id pub-id-type="doi">10.3390/ma13143061</pub-id>
</citation>
</ref>
<ref id="B12">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Huang</surname>
<given-names>C.-C.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>M.-J.</given-names>
</name>
<name>
<surname>Tsai</surname>
<given-names>P.-I.</given-names>
</name>
<name>
<surname>Kung</surname>
<given-names>P.-C.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>S.-Y.</given-names>
</name>
<name>
<surname>Sun</surname>
<given-names>J.-S.</given-names>
</name>
<etal/>
</person-group> (<year>2020</year>). <article-title>Novel design of additive manufactured hollow porous implants</article-title>. <source>Dent. Mat.</source> <volume>36</volume>, <fpage>1437</fpage>&#x2013;<lpage>1451</lpage>. <pub-id pub-id-type="doi">10.1016/j.dental.2020.08.011</pub-id>
</citation>
</ref>
<ref id="B13">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lee</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>J.-B.</given-names>
</name>
<name>
<surname>Yun</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Rhyu</surname>
<given-names>I.-C.</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>Y.-M.</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>S.-M.</given-names>
</name>
<etal/>
</person-group> (<year>2021</year>). <article-title>The impact of surface treatment in 3-dimensional printed implants for early osseointegration: a comparison study of three different surfaces</article-title>. <source>Sci. Rep.</source> <volume>11</volume>, <fpage>10453</fpage>. <pub-id pub-id-type="doi">10.1038/s41598-021-89961-3</pub-id>
</citation>
</ref>
<ref id="B14">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lewis</surname>
<given-names>G. S.</given-names>
</name>
<name>
<surname>Mischler</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Wee</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Reid</surname>
<given-names>J. S.</given-names>
</name>
<name>
<surname>Varga</surname>
<given-names>P.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Finite element analysis of fracture fixation</article-title>. <source>Curr. Osteoporos. Rep.</source> <volume>19</volume>, <fpage>403</fpage>&#x2013;<lpage>416</lpage>. <pub-id pub-id-type="doi">10.1007/s11914-021-00690-y</pub-id>
</citation>
</ref>
<ref id="B15">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Li</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Kou</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Zhou</surname>
<given-names>L.</given-names>
</name>
</person-group> (<year>2016</year>). <article-title>Porous Ti6Al4V alloys with enhanced normalized fatigue strength for biomedical applications</article-title>. <source>Mat. Sci. Eng. C</source> <volume>60</volume>, <fpage>485</fpage>&#x2013;<lpage>488</lpage>. <pub-id pub-id-type="doi">10.1016/j.msec.2015.11.074</pub-id>
</citation>
</ref>
<ref id="B16">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Li</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Jansen</surname>
<given-names>J. A.</given-names>
</name>
<name>
<surname>Walboomers</surname>
<given-names>X. F.</given-names>
</name>
<name>
<surname>van den Beucken</surname>
<given-names>J. J. J. P.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Mechanical aspects of dental implants and osseointegration: a narrative review</article-title>. <source>J. Mech. Behav. Biomed. Mat.</source> <volume>103</volume>, <fpage>103574</fpage>. <pub-id pub-id-type="doi">10.1016/j.jmbbm.2019.103574</pub-id>
</citation>
</ref>
<ref id="B17">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lietaert</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Cutolo</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Boey</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Van Hooreweder</surname>
<given-names>B.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Fatigue life of additively manufactured Ti6Al4V scaffolds under tension-tension, tension-compression and compression-compression fatigue load</article-title>. <source>Sci. Rep.</source> <volume>9</volume>, <fpage>4957</fpage>. <pub-id pub-id-type="doi">10.1038/s41598-018-23414-2</pub-id>
</citation>
</ref>
<ref id="B18">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Liu</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Kamm</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Garc&#xed;a-Moreno</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Banhart</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Pasini</surname>
<given-names>D.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>Elastic and failure response of imperfect three-dimensional metallic lattices: the role of geometric defects induced by selective laser melting</article-title>. <source>J. Mech. Phys. Solids</source> <volume>107</volume>, <fpage>160</fpage>&#x2013;<lpage>184</lpage>. <pub-id pub-id-type="doi">10.1016/j.jmps.2017.07.003</pub-id>
</citation>
</ref>
<ref id="B19">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lovera-Prado</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Vanaclocha</surname>
<given-names>V.</given-names>
</name>
<name>
<surname>Atienza</surname>
<given-names>C. M.</given-names>
</name>
<name>
<surname>Vanaclocha</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Jord&#xe1;-G&#xf3;mez</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Saiz-Sapena</surname>
<given-names>N.</given-names>
</name>
<etal/>
</person-group> (<year>2023</year>). <article-title>Barbed dental Ti6Al4V alloy screw: design and bench testing</article-title>. <source>Materials</source> <volume>16</volume>, <fpage>2228</fpage>. <pub-id pub-id-type="doi">10.3390/ma16062228</pub-id>
</citation>
</ref>
<ref id="B20">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lv</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Liu</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Tang</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Lu</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Xie</surname>
<given-names>K.</given-names>
</name>
<etal/>
</person-group> (<year>2021</year>). <article-title>Metal material, properties and design methods of porous biomedical scaffolds for additive manufacturing: a review</article-title>. <source>Front. Bioeng. Biotechnol.</source> <volume>9</volume>, <fpage>641130</fpage>. <pub-id pub-id-type="doi">10.3389/fbioe.2021.641130</pub-id>
</citation>
</ref>
<ref id="B21">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Maconachie</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Leary</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Lozanovski</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Qian</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Faruque</surname>
<given-names>O.</given-names>
</name>
<etal/>
</person-group> (<year>2019</year>). <article-title>SLM lattice structures: properties, performance, applications and challenges</article-title>. <source>Mat. Des.</source> <volume>183</volume>, <fpage>108137</fpage>. <pub-id pub-id-type="doi">10.1016/j.matdes.2019.108137</pub-id>
</citation>
</ref>
<ref id="B22">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mombelli</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>M&#xfc;ller</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Cionca</surname>
<given-names>N.</given-names>
</name>
</person-group> (<year>2012</year>). <article-title>The epidemiology of peri-implantitis</article-title>. <source>Clin. Oral Implants Res.</source> <volume>23</volume>, <fpage>67</fpage>&#x2013;<lpage>76</lpage>. <pub-id pub-id-type="doi">10.1111/j.1600-0501.2012.02541.x</pub-id>
</citation>
</ref>
<ref id="B23">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Obaton</surname>
<given-names>A.-F.</given-names>
</name>
<name>
<surname>Fain</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Djema&#xef;</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Meinel</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>L&#xe9;onard</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Mah&#xe9;</surname>
<given-names>E.</given-names>
</name>
<etal/>
</person-group> (<year>2017</year>). <article-title>
<italic>In vivo</italic> XCT bone characterization of lattice structured implants fabricated by additive manufacturing</article-title>. <source>Heliyon</source> <volume>3</volume>, <fpage>e00374</fpage>. <pub-id pub-id-type="doi">10.1016/j.heliyon.2017.e00374</pub-id>
</citation>
</ref>
<ref id="B24">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Pa&#x142;ka</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Pokrowiecki</surname>
<given-names>R.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Porous titanium implants: a review</article-title>. <source>Adv. Eng. Mat.</source> <volume>20</volume>, <fpage>1700648</fpage>. <pub-id pub-id-type="doi">10.1002/adem.201700648</pub-id>
</citation>
</ref>
<ref id="B25">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Panagiotopoulou</surname>
<given-names>V. C.</given-names>
</name>
<name>
<surname>Ovesy</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Gueorguiev</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Richards</surname>
<given-names>R. G.</given-names>
</name>
<name>
<surname>Zysset</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Varga</surname>
<given-names>P.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Experimental and numerical investigation of secondary screw perforation in the human proximal humerus</article-title>. <source>J. Mech. Behav. Biomed. Mat.</source> <volume>116</volume>, <fpage>104344</fpage>. <pub-id pub-id-type="doi">10.1016/j.jmbbm.2021.104344</pub-id>
</citation>
</ref>
<ref id="B26">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Prados-Privado</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Gehrke</surname>
<given-names>S. A.</given-names>
</name>
<name>
<surname>Rojo</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Prados-Frutos</surname>
<given-names>J. C.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Complete mechanical characterization of an external hexagonal implant connection: <italic>in vitro</italic> study, 3D FEM, and probabilistic fatigue</article-title>. <source>Med. Biol. Eng. Comput.</source> <volume>56</volume>, <fpage>2233</fpage>&#x2013;<lpage>2244</lpage>. <pub-id pub-id-type="doi">10.1007/s11517-018-1846-8</pub-id>
</citation>
</ref>
<ref id="B27">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Reddy</surname>
<given-names>M. S.</given-names>
</name>
<name>
<surname>Sundram</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Eid Abdemagyd</surname>
<given-names>H. A.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Application of finite element model in implant dentistry: a systematic review</article-title>. <source>J. Pharm. Bioallied Sci.</source> <volume>11</volume>, <fpage>S85</fpage>&#x2013;<lpage>S91</lpage>. <pub-id pub-id-type="doi">10.4103/JPBS.JPBS_296_18</pub-id>
</citation>
</ref>
<ref id="B28">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Rojo</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Prados-Privado</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Reinoso</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Prados-Frutos</surname>
<given-names>J.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Evaluation of fatigue behavior in dental implants from <italic>in vitro</italic> clinical tests: a systematic review</article-title>. <source>Metals</source> <volume>8</volume>, <fpage>313</fpage>. <pub-id pub-id-type="doi">10.3390/met8050313</pub-id>
</citation>
</ref>
<ref id="B29">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Schneider</surname>
<given-names>C. A.</given-names>
</name>
<name>
<surname>Rasband</surname>
<given-names>W. S.</given-names>
</name>
<name>
<surname>Eliceiri</surname>
<given-names>K. W.</given-names>
</name>
</person-group> (<year>2012</year>). <article-title>NIH image to ImageJ: 25 years of image analysis</article-title>. <source>Nat. Methods</source> <volume>9</volume>, <fpage>671</fpage>&#x2013;<lpage>675</lpage>. <pub-id pub-id-type="doi">10.1038/nmeth.2089</pub-id>
</citation>
</ref>
<ref id="B30">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Shemtov-Yona</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Rittel</surname>
<given-names>D.</given-names>
</name>
</person-group> (<year>2014</year>). <article-title>Identification of failure mechanisms in retrieved fractured dental implants</article-title>. <source>Eng. Fail. Anal.</source> <volume>38</volume>, <fpage>58</fpage>&#x2013;<lpage>65</lpage>. <pub-id pub-id-type="doi">10.1016/j.engfailanal.2014.01.002</pub-id>
</citation>
</ref>
<ref id="B31">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Song</surname>
<given-names>S.-Y.</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>J.-Y.</given-names>
</name>
<name>
<surname>Shin</surname>
<given-names>S.-W.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>Effect of implant diameter on fatigue strength</article-title>. <source>Implant Dent.</source> <volume>26</volume>, <fpage>59</fpage>&#x2013;<lpage>65</lpage>. <pub-id pub-id-type="doi">10.1097/ID.0000000000000502</pub-id>
</citation>
</ref>
<ref id="B32">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Soro</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Attar</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Wu</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Dargusch</surname>
<given-names>M. S.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Investigation of the structure and mechanical properties of additively manufactured Ti-6Al-4V biomedical scaffolds designed with a Schwartz primitive unit-cell</article-title>. <source>Mat. Sci. Eng. A</source> <volume>745</volume>, <fpage>195</fpage>&#x2013;<lpage>202</lpage>. <pub-id pub-id-type="doi">10.1016/j.msea.2018.12.104</pub-id>
</citation>
</ref>
<ref id="B33">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Taylor</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Prendergast</surname>
<given-names>P. J.</given-names>
</name>
</person-group> (<year>2015</year>). <article-title>Four decades of finite element analysis of orthopaedic devices: where are we now and what are the opportunities?</article-title> <source>J. Biomech.</source> <volume>48</volume>, <fpage>767</fpage>&#x2013;<lpage>778</lpage>. <pub-id pub-id-type="doi">10.1016/j.jbiomech.2014.12.019</pub-id>
</citation>
</ref>
<ref id="B34">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Trivedi</surname>
<given-names>S.</given-names>
</name>
</person-group> (<year>2014</year>). <article-title>Finite element analysis: a boon to dentistry</article-title>. <source>J. Oral Biol. Craniofacial Res.</source> <volume>4</volume>, <fpage>200</fpage>&#x2013;<lpage>203</lpage>. <pub-id pub-id-type="doi">10.1016/j.jobcr.2014.11.008</pub-id>
</citation>
</ref>
<ref id="B35">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Tsai</surname>
<given-names>Y.-T.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>K.-S.</given-names>
</name>
<name>
<surname>Woo</surname>
<given-names>J.-C.</given-names>
</name>
</person-group> (<year>2013</year>). <article-title>Fatigue life and reliability evaluation for dental implants based on computer simulation and limited test data</article-title>. <source>Proc. Inst. Mech. Eng. Part C J. Mech. Eng. Sci.</source> <volume>227</volume>, <fpage>554</fpage>&#x2013;<lpage>564</lpage>. <pub-id pub-id-type="doi">10.1177/0954406212463532</pub-id>
</citation>
</ref>
<ref id="B36">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Vanmunster</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>D&#x2019;Haeyer</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Coucke</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Braem</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Van Hooreweder</surname>
<given-names>B.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Mechanical behavior of Ti6Al4V produced by laser powder bed fusion with engineered open porosity for dental applications</article-title>. <source>J. Mech. Behav. Biomed. Mat.</source> <volume>126</volume>, <fpage>104974</fpage>. <pub-id pub-id-type="doi">10.1016/j.jmbbm.2021.104974</pub-id>
</citation>
</ref>
<ref id="B37">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Velasco-Ortega</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Flichy-Fern&#xe1;ndez</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Punset</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Jim&#xe9;nez-Guerra</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Manero</surname>
<given-names>J. M.</given-names>
</name>
<name>
<surname>Gil</surname>
<given-names>J.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Fracture and fatigue of titanium narrow dental implants: new trends in order to improve the mechanical response</article-title>. <source>Materials</source> <volume>12</volume>, <fpage>3728</fpage>. <pub-id pub-id-type="doi">10.3390/ma12223728</pub-id>
</citation>
</ref>
<ref id="B38">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wang</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Feng</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>Y.</given-names>
</name>
<etal/>
</person-group> (<year>2019</year>). <article-title>Studies on the performance of selective laser melting porous dental implant by finite element model simulation, fatigue testing and <italic>in vivo</italic> experiments</article-title>. <source>Proc. Inst. Mech. Eng. H.</source> <volume>233</volume>, <fpage>170</fpage>&#x2013;<lpage>180</lpage>. <pub-id pub-id-type="doi">10.1177/0954411918816114</pub-id>
</citation>
</ref>
<ref id="B39">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Xiong</surname>
<given-names>Y.-Z.</given-names>
</name>
<name>
<surname>Gao</surname>
<given-names>R.-N.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Dong</surname>
<given-names>L.-L.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>J.-T.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>X.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Rationally designed functionally graded porous Ti6Al4V scaffolds with high strength and toughness built via selective laser melting for load-bearing orthopedic applications</article-title>. <source>J. Mech. Behav. Biomed. Mat.</source> <volume>104</volume>, <fpage>103673</fpage>. <pub-id pub-id-type="doi">10.1016/j.jmbbm.2020.103673</pub-id>
</citation>
</ref>
<ref id="B40">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yang</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Zhou</surname>
<given-names>Q.</given-names>
</name>
<name>
<surname>Gong</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>C.</given-names>
</name>
<etal/>
</person-group> (<year>2017</year>). <article-title>Laser beam melting 3D printing of Ti6Al4V based porous structured dental implants: fabrication, biocompatibility analysis and photoelastic study</article-title>. <source>Sci. Rep.</source> <volume>7</volume>, <fpage>45360</fpage>. <pub-id pub-id-type="doi">10.1038/srep45360</pub-id>
</citation>
</ref>
<ref id="B41">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zargarian</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Esfahanian</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Kadkhodapour</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Ziaei-Rad</surname>
<given-names>S.</given-names>
</name>
</person-group> (<year>2016</year>). <article-title>Numerical simulation of the fatigue behavior of additive manufactured titanium porous lattice structures</article-title>. <source>Mat. Sci. Eng. C</source> <volume>60</volume>, <fpage>339</fpage>&#x2013;<lpage>347</lpage>. <pub-id pub-id-type="doi">10.1016/j.msec.2015.11.054</pub-id>
</citation>
</ref>
<ref id="B42">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhang</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Mao</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Zhou</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Ji</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>X.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Study on statics and fatigue analysis of dental implants in the descending process of alveolar bone level</article-title>. <source>Proc. Inst. Mech. Eng. H.</source> <volume>234</volume>, <fpage>843</fpage>&#x2013;<lpage>853</lpage>. <pub-id pub-id-type="doi">10.1177/0954411920926080</pub-id>
</citation>
</ref>
<ref id="B43">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zheng</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Fu</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Du</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Yi</surname>
<given-names>Y.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Minimal surface designs for porous materials: from microstructures to mechanical properties</article-title>. <source>J. Mat. Sci.</source> <volume>53</volume>, <fpage>10194</fpage>&#x2013;<lpage>10208</lpage>. <pub-id pub-id-type="doi">10.1007/s10853-018-2285-5</pub-id>
</citation>
</ref>
</ref-list>
</back>
</article>