<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article article-type="research-article" dtd-version="2.3" xml:lang="EN" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Bioeng. Biotechnol.</journal-id>
<journal-title>Frontiers in Bioengineering and Biotechnology</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Bioeng. Biotechnol.</abbrev-journal-title>
<issn pub-type="epub">2296-4185</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">1214493</article-id>
<article-id pub-id-type="doi">10.3389/fbioe.2023.1214493</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Bioengineering and Biotechnology</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>High-throughput optical sensing of peri-cellular oxygen in cardiac cells: system characterization, calibration, and testing</article-title>
<alt-title alt-title-type="left-running-head">Li et al.</alt-title>
<alt-title alt-title-type="right-running-head">
<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3389/fbioe.2023.1214493">10.3389/fbioe.2023.1214493</ext-link>
</alt-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Li</surname>
<given-names>Weizhen</given-names>
</name>
<xref ref-type="fn" rid="fn1">
<sup>&#x2020;</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1341533/overview"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>McLeod</surname>
<given-names>David</given-names>
</name>
<xref ref-type="fn" rid="fn1">
<sup>&#x2020;</sup>
</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Ketzenberger</surname>
<given-names>John T.</given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Kowalik</surname>
<given-names>Grant</given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Russo</surname>
<given-names>Rebekah</given-names>
</name>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Li</surname>
<given-names>Zhenyu</given-names>
</name>
<xref ref-type="corresp" rid="c001">&#x2a;</xref>
<uri xlink:href="https://loop.frontiersin.org/people/2043216/overview"/>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Kay</surname>
<given-names>Matthew W.</given-names>
</name>
<xref ref-type="corresp" rid="c001">&#x2a;</xref>
<uri xlink:href="https://loop.frontiersin.org/people/531366/overview"/>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Entcheva</surname>
<given-names>Emilia</given-names>
</name>
<xref ref-type="corresp" rid="c001">&#x2a;</xref>
<uri xlink:href="https://loop.frontiersin.org/people/33721/overview"/>
</contrib>
</contrib-group>
<aff>
<institution>Department of Biomedical Engineering</institution>, <institution>School of Engineering and Applied Science</institution>, <institution>The George Washington University</institution>, <addr-line>Washington</addr-line>, <addr-line>DC</addr-line>, <country>United States</country>
</aff>
<author-notes>
<fn fn-type="edited-by">
<p>
<bold>Edited by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/980513/overview">Run Zhang</ext-link>, The University of Queensland, Australia</p>
</fn>
<fn fn-type="edited-by">
<p>
<bold>Reviewed by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/1474323/overview">Hua Ma</ext-link>, Massachusetts General Hospital and Harvard Medical School, United States</p>
<p>
<ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/1572660/overview">Xudong Lin</ext-link>, Sun Yat-sen University, China</p>
<p>
<ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/822250/overview">Trieu Nguyen</ext-link>, Honda Research Institute USA Mountain View, United States</p>
</fn>
<corresp id="c001">
<sup>&#x2a;</sup>Correspondence: Zhenyu Li, <email>zhenyu@gwu.edu</email>; Matthew W. Kay, <email>phymwk@gwu.edu</email>; Emilia Entcheva, <email>entcheva@gwu.edu</email>
</corresp>
<fn fn-type="equal" id="fn1">
<label>
<sup>&#x2020;</sup>
</label>
<p>These authors have contributed equally to this work and share first authorship</p>
</fn>
</author-notes>
<pub-date pub-type="epub">
<day>16</day>
<month>06</month>
<year>2023</year>
</pub-date>
<pub-date pub-type="collection">
<year>2023</year>
</pub-date>
<volume>11</volume>
<elocation-id>1214493</elocation-id>
<history>
<date date-type="received">
<day>29</day>
<month>04</month>
<year>2023</year>
</date>
<date date-type="accepted">
<day>07</day>
<month>06</month>
<year>2023</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#xa9; 2023 Li, McLeod, Ketzenberger, Kowalik, Russo, Li, Kay and Entcheva.</copyright-statement>
<copyright-year>2023</copyright-year>
<copyright-holder>Li, McLeod, Ketzenberger, Kowalik, Russo, Li, Kay and Entcheva</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p>
</license>
</permissions>
<abstract>
<p>Human-induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) represent a scalable experimental model relevant to human physiology. Oxygen consumption of hiPSC-CMs has not been studied in high-throughput (HT) format plates used in pre-clinical studies. Here, we provide comprehensive characterization and validation of a system for HT long-term optical measurements of peri-cellular oxygen in cardiac syncytia (human iPSC-CM and human cardiac fibroblasts), grown in glass-bottom 96-well plates. Laser-cut oxygen sensors having a ruthenium dye and an oxygen-insensitive reference dye were used. Ratiometric measurements (409&#xa0;nm excitation) reflected dynamic changes in oxygen, as validated with simultaneous Clark electrode measurements. Emission ratios (653&#xa0;nm vs. 510&#xa0;nm) were calibrated for percent oxygen using two-point calibration. Time-dependent changes in the Stern-Volmer parameter, <italic>ksv</italic>, were observed during the initial 40&#x2013;90&#xa0;min of incubation, likely temperature-related. Effects of pH on oxygen measurements were negligible in the pH range of 4&#x2013;8, with a small ratio reduction for pH &#x3e; 10. Time-dependent calibration was implemented, and light exposure time was optimized (0.6&#x2013;0.8&#xa0;s) for oxygen measurements inside an incubator. Peri-cellular oxygen dropped to levels &#x3c;5% within 3&#x2013;10&#xa0;h for densely-plated hiPSC-CMs in glass-bottom 96-well plates. After the initial oxygen decrease, samples either settled to low steady-state or exhibited intermittent peri-cellular oxygen dynamics. Cardiac fibroblasts showed slower oxygen depletion and higher steady-state levels without oscillations, compared to hiPSC-CMs. Overall, the system has great utility for long-term HT monitoring of peri-cellular oxygen dynamics <italic>in vitro</italic> for tracking cellular oxygen consumption, metabolic perturbations, and characterization of the maturation of hiPSC-CMs.</p>
</abstract>
<kwd-group>
<kwd>optical oxygen sensors</kwd>
<kwd>peri-cellular oxygen</kwd>
<kwd>ruthenium oxygen sensors</kwd>
<kwd>human iPSC-CMs</kwd>
<kwd>cardiac fibroblasts</kwd>
<kwd>high-throughput plates</kwd>
</kwd-group>
<contract-sponsor id="cn001">National Heart, Lung, and Blood Institute<named-content content-type="fundref-id">10.13039/100000050</named-content>
</contract-sponsor>
<contract-sponsor id="cn002">Division of Emerging Frontiers in Research and Innovation<named-content content-type="fundref-id">10.13039/100000150</named-content>
</contract-sponsor>
<custom-meta-wrap>
<custom-meta>
<meta-name>section-at-acceptance</meta-name>
<meta-value>Biosensors and Biomolecular Electronics</meta-value>
</custom-meta>
</custom-meta-wrap>
</article-meta>
</front>
<body>
<sec id="s1">
<title>1 Introduction</title>
<p>Oxygen is important for nearly all biological processes (<xref ref-type="bibr" rid="B16">Keeley and Mann, 2019</xref>). The function of aerobic cells relying on oxidative phosphorylation, such as cardiomyocytes, is highly dependent upon oxygen availability. Precise monitoring of oxygen levels in the immediate cell vicinity (peri-cellular oxygen) will provide invaluable insight into the metabolic state of the cells. Over the last two&#xa0;decades, human induced pluripotent stem cell derived cardiomyocytes (hiPSC-CMs) have emerged as a new scalable experimental model for cardiovascular research and translation (<xref ref-type="bibr" rid="B3">Burridge et al., 2016</xref>; <xref ref-type="bibr" rid="B4">Chen et al., 2016</xref>; <xref ref-type="bibr" rid="B39">Shi et al., 2017</xref>). The growth of these cells <italic>in vitro</italic> is being optimized for applications in regenerative medicine, drug development, cardiotoxicity testing, and other personalized medicine applications (<xref ref-type="bibr" rid="B40">Strauss and Blinova, 2017</xref>; <xref ref-type="bibr" rid="B9">Gintant et al., 2019</xref>; <xref ref-type="bibr" rid="B47">Yang et al., 2022</xref>). iPSC-CM oxygen consumption and metabolism are considered of key importance for their maturity (<xref ref-type="bibr" rid="B34">Rana et al., 2012</xref>; <xref ref-type="bibr" rid="B37">Sekine et al., 2014</xref>; <xref ref-type="bibr" rid="B15">Karbassi et al., 2020</xref>). For drug development and cardiotoxicity studies, human iPSC-CMs are typically grown in static culture using glass-bottom high-throughput format plates (96-well or 384-well plates). In such conditions, the only oxygen diffusion path is from the top, through the solution. Long-term studies of peri-cellular oxygen dynamics in human cardiac cells in such high-throughput plates are lacking, yet highly desirable.</p>
<p>Historically, oxygen sensing has evolved, starting with amperometric measurements using a Clark electrode (<xref ref-type="bibr" rid="B5">Clark, 1956</xref>; <xref ref-type="bibr" rid="B38">Severinghaus, 2004</xref>), where the electrochemical reduction of oxygen is registered by changes in electric current. This method still serves as the gold standard. Yet, it has limitations, especially for assessing oxygen dynamics in small spaces/volumes, including assessment of peri-cellular oxygen. This is due to the consumption/depletion of oxygen at the sensor during the measurement and the general difficulty in miniaturizing this type of sensor. Contactless optical methods present an alternative. A variety of fluorescent dyes have been developed to register very low (&#x3c;5%) oxygen levels (<xref ref-type="bibr" rid="B36">Sandhu et al., 2017</xref>; <xref ref-type="bibr" rid="B50">Yoshihara et al., 2017</xref>), including near-infrared indicators for <italic>in vivo</italic> measurements (<xref ref-type="bibr" rid="B19">Kiyose et al., 2010</xref>). The limitations of such dyes include difficulty in providing a quantitative assessment and in covering a broader range of physiological values.</p>
<p>The Seahorse XF platform (<xref ref-type="bibr" rid="B8">Gerencser et al., 2009</xref>) is a high-throughput version of an optical oxygen measurement system. It has numerous applications in rigorous metabolic profiling of mammalian cells and isolated mitochondria (<xref ref-type="bibr" rid="B35">Rogers et al., 2011</xref>; <xref ref-type="bibr" rid="B14">Invernizzi et al., 2012</xref>; <xref ref-type="bibr" rid="B2">Divakaruni et al., 2014</xref>), including iPSC-CMs (<xref ref-type="bibr" rid="B34">Rana et al., 2012</xref>). It provides quantitative assessments of oxygen consumption rate (OCR) and extracellular acidification rate (ECAR), including in a 96-well format, as it offers oxygen and pH measurements through the optical sensors embedded in the tips of the fiber optics array. However, the Seahorse assay is applicable only to acute terminal measurements and therefore cannot be used for long-term tracking of peri-cellular oxygen dynamics.</p>
<p>Luminescence-based oxygen sensors, often combined with fiber optics, have been demonstrated to offer reliable oxygen tracking over time (<xref ref-type="bibr" rid="B24">Kostov and Rao, 1999</xref>; <xref ref-type="bibr" rid="B23">Kostov et al., 2000a</xref>; <xref ref-type="bibr" rid="B29">Liebsch et al., 2000</xref>; <xref ref-type="bibr" rid="B43">Wang and Wolfbeis, 2014</xref>). Their operation is based on dynamic oxygen quenching of fluorescence, as reflected in the Stern-Volmer relationship between oxygen concentration and fluorescence (<xref ref-type="bibr" rid="B20">Klimant et al., 1995</xref>). Quantitative optical oxygen sensing is typically done through life-time measurements (using frequency modulation) or through ratiometric intensity measurements with an oxygen-responsive dye (e.g. ruthenium-based) and a reference dye (<xref ref-type="bibr" rid="B22">Kostov et al., 1998</xref>; <xref ref-type="bibr" rid="B25">Kostov et al., 2000b</xref>; <xref ref-type="bibr" rid="B43">Wang and Wolfbeis, 2014</xref>). Scalability with such luminescence-based oxygen sensors has been achieved through improved matrix embedding of the dye and production of oxygen-sensing scaffolds for space-resolved measurements (<xref ref-type="bibr" rid="B18">Kellner et al., 2002</xref>; <xref ref-type="bibr" rid="B45">Wolff et al., 2019</xref>; <xref ref-type="bibr" rid="B32">Peniche Silva et al., 2020</xref>), as well as through advances in visualization with high spatiotemporal resolution (<xref ref-type="bibr" rid="B41">Tschiersch et al., 2012</xref>).</p>
<p>In this study we characterized and validated a high-throughput platform for longitudinal optical sensing of peri-cellular oxygen in human iPSC-CMs and human cardiac fibroblasts in 96-well format within a standard cell culture incubator. The system is based on the VisiSensTD oxygen imaging system (PreSens Precision Sensing GmbH, Germany) and our high throughput microfluidics-based uninterrupted cell culture perfusion system (HT-&#xb5;UPS). Results demonstrate that the system provides accurate and reproducible long-term measurements of peri-cellular oxygen levels that will be valuable for studies of cellular oxygen consumption, metabolic perturbations, and characterization of the maturation of cultured iPSC-CMs.</p>
</sec>
<sec sec-type="materials|methods" id="s2">
<title>2 Materials and methods</title>
<sec id="s2-1">
<title>2.1 Optical oxygen sensors and peri-cellular oxygen imaging</title>
<p>Peri-cellular oxygen was measured using emission ratiometry. An integrated system comprised of an LED light source and an RGB camera (VisiSensTD, PreSens) imaged changes in the luminescence of optical oxygen sensors placed at the bottom of each well of a 96-well glass-bottom plate (<xref ref-type="fig" rid="F1">Figure 1A</xref>). The plate was placed on top of the VisiSensTD system for continuous monitoring in a cell culture incubator. The oxygen sensor membrane (pink, <xref ref-type="fig" rid="F1">Figure 1B</xref>) incorporated an oxygen-responsive ruthenium dye and an oxygen-insensitive reference dye. Blue light from the LEDs positioned around the camera lens excited the two dyes. The camera imaged the entire plate to acquire oxygen-dependent changes in the luminescence ratio of the two dyes within the sensor located in each well of the plate.</p>
<fig id="F1" position="float">
<label>FIGURE 1</label>
<caption>
<p>System and workflow for high-throughput optical measurements of peri-cellular oxygen. <bold>(A)</bold>. Incubator-deployed imaging system for 96-well plates, with an RGB camera, ring LED illuminator and bellows extension to fit a 96-well plate; inset shows top-down view with the lens and the LED ring with excitation filter. <bold>(B)</bold>. Schematic of a single well with an optical oxygen sensor composition and placement in half of the well. Peri-cellular oxygen is imaged ratiometrically through the glass bottom of the well plate; partial coverage allows for other parameters to be measured optically, e.g. voltage, calcium etc. <bold>(C)</bold>. Laser-cutting of semicircular oxygen sensor patches, 5&#xa0;mm diameter. <bold>(D)</bold>. Mounting of the oxygen sensors: patches are detached from the adhesive backing and placed in wells using vacuum tubing. <bold>(E)</bold>. Images of the oxygen sensors in wells, raw optical readout and processed readings of oxygen. In the example, the upper left quadrant of the plate has been treated with oxygen-depleting Na<sub>2</sub>SO<sub>3</sub>.</p>
</caption>
<graphic xlink:href="fbioe-11-1214493-g001.tif"/>
</fig>
<p>The oxygen sensors were semicircles that covered half the glass bottom of each well. They were laser-cut from a larger sheet (PreSens SF-RPSu4) that consisted of an oxygen sensitive layer, a polyester support layer, and a white optical isolation layer, which was placed onto a sacrificial acrylic sheet with the adhesive facing up (<xref ref-type="fig" rid="F1">Figure 1C</xref>). Semicircular sensors were then laser-cut using a 30&#xa0;W CO2 laser (Universal Laser Systems VLS 2.3) by placing the acrylic layer on the laser cutter bed and focusing the laser on the top of the acrylic layer. The laser cutting path was drawn in AutoCAD 2022 to cut semicircles with a radius of 2.5&#xa0;mm using 15% maximum laser power and 10% maximum speed.</p>
</sec>
<sec id="s2-2">
<title>2.2 Oxygen sensor attachment and plate sterilization</title>
<p>Oxygen sensors were attached to the bottom of the wells of 96-well plates using sterile procedures inside a laminar flow hood. Sensors were lifted with tweezers to expose the white optical blocking layer while placing a suction tube (ID &#x3c; 2&#xa0;mm) against this layer to hold the sensor while lowering it into a well (<xref ref-type="fig" rid="F1">Figure 1D</xref>). The suction in the tube was released once the adhesive layer attached to the glass. The process was repeated to place sensors in each well (<xref ref-type="fig" rid="F1">Figure 1E</xref>). Before using the plate for a cell culture experiment, the wells were sterilized with 70% ethanol inside the sterile laminar flow fume hood. After the ethanol evaporated, each well was washed three times with 1x PBS, before coating with fibronectin. After an experiment, raw images acquired by the VisiSensTD system were processed using a two-point calibration to convert the RGB values for pixels that imaged each sensor to a percentage corresponding to the peri-cellular oxygen level. An example raw luminescence image showing the optical sensors in a 96-well plate and the processed oxygen reading is illustrated in <xref ref-type="fig" rid="F1">Figure 1E</xref>.</p>
</sec>
<sec id="s2-3">
<title>2.3 Oxygen sensor spectral characterization</title>
<p>Spectra for the full range of aqueous oxygen concentration were first measured by bubbling a beaker of water with 100% O<sub>2</sub> gas followed by bubbling with 100% N<sub>2</sub> gas (<xref ref-type="fig" rid="F2">Figure 2A</xref>). A sensor attached to the bottom of the beaker was illuminated with excitation light from the VisiSenseTD system and the spectrum of emitted light was acquired once every second using a spectrometer (Ocean Optics QE-Pro, <xref ref-type="fig" rid="F2">Figure 2B</xref>).</p>
<fig id="F2" position="float">
<label>FIGURE 2</label>
<caption>
<p>Spectral characterization of the optical system for peri-cellular oxygen imaging and confirmation of an inverse Stern-Volmer relationship. <bold>(A)</bold>. Schematic of the setup used to characterize oxygen-sensitive responses in a beaker of water. <bold>(B)</bold>. Spectral results in water: excitation light emission is at 409&#xa0;nm; oxygen-sensitive emission peak is at 653&#xa0;nm, with emission decreasing as O<sub>2</sub> concentration increases. <bold>(C)</bold>. Schematic and photo of the setup for spectral characterization of oxygen responses in a 96-well microplate with a specialized microfluidic cover (our HT-&#x3bc;UPS system). The oxygen sensor pad is at the bottom of one well. <bold>(D)</bold>. Spectral data in cell culture media, showing oxygen-dependent spectral shifts at 653nm, consistent with results from water shown in panel <bold>(B)</bold>. <bold>(E)</bold>. An inverse Stern-Volmer relationship was derived from the ratios (intensity at 653/intensity at 510), measured from the spectra shown in panel <bold>(D)</bold>, which is linear for the low oxygen range considered (&#x3c;20%).</p>
</caption>
<graphic xlink:href="fbioe-11-1214493-g002.tif"/>
</fig>
<p>Spectra for oxygen concentrations that are typical for cell cultures were acquired using a similar approach and our high throughput microfluidics-based uninterrupted perfusion system (HT-&#xb5;UPS) cover for a 96-well plate (<xref ref-type="bibr" rid="B44">Wei et al., 2020</xref>) (<xref ref-type="fig" rid="F2">Figure 2C</xref>). Nitrogen-bubbled cell culture media (0% O<sub>2</sub>) and media equilibrated in room air (21% O<sub>2</sub>) were loaded into two separate syringes that were each placed in one of two syringe pumps (New Era 1600 &#xd7; 2). Media from each syringe flowed through a sensor (Sensirion SLI-2000) that measured the flow rate as media moved through our HT-&#xb5;UPS cover to perfuse the wells of the plate (<xref ref-type="fig" rid="F2">Figure 2C</xref>). Flow-through Clark electrodes (Microelectrodes Inc. MI-730) incorporated into the tubing before and after the plate measured the media oxygen concentration at those positions. The system flow rate was maintained at 200&#xa0;ml/min while the flow rates of the two syringe pumps were varied to achieve mixtures of 0, 8, 12, 16, and 20 percent O<sub>2</sub>, which were confirmed by the Clark electrodes. The same spectrometer and fiber optic cable setup as in <xref ref-type="fig" rid="F2">Figure 2A</xref> was used to acquire the luminescence spectrum of a sensor within one well once every second.</p>
<p>Spectra collected during each characterization were plotted together to visualize changes in spectral bands corresponding to the oxygen-insensitive reference dye (centered at 510&#xa0;nm, &#x201c;green&#x201d;) and the oxygen-responsive ruthenium dye (centered at 653nm, &#x201c;red&#x201d;, <xref ref-type="fig" rid="F2">Figure 2D</xref>). Values at the peak wavelengths for red and green luminescence (<xref ref-type="fig" rid="F2">Figure 2D</xref>, dashed lines) were used to construct the inverse Stern-Volmer relation in <xref ref-type="fig" rid="F2">Figure 2E</xref>. For this relationship, the ratio of red to green emission was plotted against each oxygen concentration measured by the Clark electrode placed before the plate. A linear fit of ratio <italic>versus</italic> oxygen concentration was used due to the small oxygen concentration range of 0%&#x2013;20% that corresponds to typical cell culture conditions.</p>
</sec>
<sec id="s2-4">
<title>2.4 Oxygen-impermeant HT-&#xb5;UPS cover and temporal characterization</title>
<p>The responsiveness of the oxygen sensing system to changes in media oxygen concentration and flow rate was characterized using 96-well plates and a new oxygen-impermeant version of the HT-&#xb5;UPS cover described in our previous work (<xref ref-type="bibr" rid="B44">Wei et al., 2020</xref>). This cover was assembled in two components, one soft PDMS sealing gasket and one acrylic perfusion base that was CNC-milled from cast acrylic (McMaster-Carr 8560K354) and thermally bonded using a heat press (Rosineer Grip Twist) at 130&#xb0;C for 3&#xa0;h. The sealing gasket was fabricated by pouring a mixture of Sylgard 184 (Dow) and Dragonskin 10 (Smooth-On) in a 1:2 ratio into an acrylic mold. Finally, an inlet and outlet were tapped (10&#x2013;32 thread) for each well and fitted with stainless steel 10&#x2013;32 barb-to-thread connectors (Pneumadyne).</p>
<p>The sensor response within the perfusion system HT-&#xb5;UPS was validated using the setup in <xref ref-type="fig" rid="F3">Figure 3A</xref>. Clark electrodes were placed before and after the cover. An optical oxygen sensor was placed at the bottom of the leftmost well of the cover. The Clark electrodes and VisiSensTD system were calibrated with water at 100% O<sub>2</sub> and 0% O<sub>2</sub>. Water bubbled with 100% O<sub>2</sub> was loaded into a syringe pump and perfused through the cover. Flow rate was measured using a flow meter (Sensirion SLI-2000) and varied between 500&#xa0;ml/min and 200&#xa0;ml/min to determine the system&#x2019;s response to changes in flow.</p>
<fig id="F3" position="float">
<label>FIGURE 3</label>
<caption>
<p>Validation of optical oxygen measurements with an electrochemical Clark electrode. <bold>(A)</bold>. Schematic of the setup used to perform the validation. The HT-&#x3bc;UPS was with an acrylic microfluidic cover. <bold>(B)</bold>. Measurements with the Clark electrodes positioned before and after the cover. Perfusion flow was varied to alter the oxygenation of the 96-well plate (see vertical lines). <bold>(C)</bold>. Simultaneous measurements with the optical system reading the optical oxygen sensor within the microwell.</p>
</caption>
<graphic xlink:href="fbioe-11-1214493-g003.tif"/>
</fig>
</sec>
<sec id="s2-5">
<title>2.5 Two-point oxygen calibration</title>
<p>A two-point calibration converted the ratio of red to green luminescence intensity imaged from the sensors into percentage of air saturation similar to (<xref ref-type="bibr" rid="B32">Peniche Silva et al., 2020</xref>). The terms &#x2018;Cal0&#x2019; and &#x2018;Cal100&#x2019; were used in system characterization experiments for 0% and 100% air saturation, and oxygen saturation levels ranging from 0% to 18.6% were displayed in cell experiments (the equilibrium oxygen partial pressure in a humidified 37&#xb0;C, 5% CO<sub>2</sub> incubator is 18.6%).</p>
<p>Two types of culture media, CDI iCell Cardiomyocytes<sup>2</sup> maintenance medium (Fujifilm CDI) and cardiac fibroblasts growth medium (Cell Applications, Inc.), were used. The air-saturated medium (Cal100) was medium straight from the bottle, warmed to around 37&#xb0;C. And the 0% air-saturated medium (Cal0) was medium with 5% completely dissolved Na<sub>2</sub>SO<sub>3</sub> and placed in the 37&#xb0;C water bath for 30&#xa0;min. In testing pH&#x2019;s influence on oxygen readout, the media were adjusted with NaOH or HCL to pH 10 or pH 4.</p>
</sec>
<sec id="s2-6">
<title>2.6 Cell plating and peri-cellular oxygen monitoring</title>
<p>Human iPSC-derived cardiomyocytes (iCell Cardiomyocytes<sup>2</sup> CMC-100-012-001 from a female Caucasian donor) from Fujifilm Cellular Dynamics International (CDI), and human cardiac fibroblasts, CF (Cell Applications, Inc.) were thawed according to manufacturer&#x2019;s instructions. Cells were plated (50,000 cells per well) in the wells of a 96-well glass-bottom plate containing half-moon shaped oxygen sensors, that have been sterilized and fibronectin-coated (at 50&#xa0;&#x3bc;g/ml). Culture medium exchange was done every 48&#xa0;h. In some experiments, hypoxia was induced on day five after plating by filling the wells to the top with culture medium and sealing them with oxygen-impermeable tape before readout in the VisiSense system.</p>
<p>The VisiSenseTD system was temperature-equilibrated in the cell culture incubator at least an hour before the start of measurements. For the whole plate oxygen monitoring in human iPSC-CMs, the peri-cellular oxygen measurements started 5&#xa0;h after the cell plating, after the switch from the cell plating medium to the cell maintenance medium. And for the hiPSC-CMs and cardiac fibroblast hypoxia comparison experiment, oxygen monitoring started right after the hypoxic condition was established. Oxygen recordings were set to continue for 24&#x2013;48&#xa0;h, with a 10&#xa0;min sampling interval and 0.8&#xa0;s exposure time.</p>
</sec>
<sec id="s2-7">
<title>2.7 Cell visualization</title>
<p>Cells grown on the non-transparent oxygen sensors were visualized using an upright Leica TCS SP8 microscope with a &#xd7;25 water immersion objective (for this imaging, sensors were attached to the glass bottom 35&#xa0;mm dishes). Cell imaging of the glass-bottom portion of the 96 wells was performed using an inverted confocal microscope (Zeiss LSM 710) or inverted Nikon Eclipse Ti2 microscope. Samples were formaldehyde-fixed, permeabilized and labeled as described previously (<xref ref-type="bibr" rid="B27">Li et al., 2020</xref>; <xref ref-type="bibr" rid="B44">Wei et al., 2020</xref>). Nuclei were labeled with Hoechst (H3570, Thermo-Fisher Scientific), the cytoskeleton was labeled either for F-actin using Alexa-488 phalloidin (A12379, Thermo-Fisher Scientific) or using &#x3b1;-actinin antibody (A7811, Millipore-Sigma), and some samples were genetically modified to express the optogenetic actuator Channelrhodopsin-2 with a fluorescent reporter eYFP.</p>
</sec>
<sec id="s2-8">
<title>2.8 Oxygen data analysis</title>
<p>Peri-cellular oxygen readings were acquired as PNG images and then analyzed through VisiSensVS software by selecting regions of interest in each image. Measured ratios were calibrated to percentage oxygen readings using two-point calibration with 5% Na<sub>2</sub>SO<sub>3</sub> and upon saturation with ambient air. Time-dependent calibration files were applied in the first 2&#xa0;h of recording, considering the temperature-induced changes in transferring the plate from room temperature operation to the 37&#xb0;C humidified incubator. Whole-plate data normalization was applied by identifying the maximum and minimum ratio readouts from the whole plate throughout the whole period of recording. A scale factor was calculated by setting the maximum oxygen reading as 18.6%, the equilibrium oxygen concentration in a cell culture incubator.</p>
</sec>
<sec id="s2-9">
<title>2.9 Statistical analysis</title>
<p>To quantify the influence of exposure time on the ratio of red to green luminescence intensity, the mean and standard deviation (mean &#xb1; SD) of ratios from a 96-well plate were computed and displayed. The spatial variation of the ratios across a plate was assessed for 0.8&#xa0;s of exposure time. For time-dependent calibration and for the assessment of the effect of pH on oxygen measurements, the change in the ratio of red to green luminescence intensity over time was calculated and displayed as (mean &#xb1; SD).</p>
</sec>
</sec>
<sec sec-type="results" id="s3">
<title>3 Results</title>
<sec id="s3-1">
<title>3.1 Mechanism of optical peri-cellular oxygen measurements</title>
<p>Optical peri-cellular oxygen measurements were based on dynamic oxygen quenching of a ruthenium dye embedded in the sensor patches on top of which cells were grown. For quantitative ratiometric readout, red and green luminescence intensity ratios were converted to percentage of oxygen saturation (pO2) using an adapted Stern-Volmer equation:<disp-formula id="e1">
<mml:math id="m1">
<mml:mrow>
<mml:mfrac>
<mml:mrow>
<mml:msub>
<mml:mi>R</mml:mi>
<mml:mi>o</mml:mi>
</mml:msub>
</mml:mrow>
<mml:mrow>
<mml:mi>R</mml:mi>
</mml:mrow>
</mml:mfrac>
<mml:mo>&#x3d;</mml:mo>
<mml:msup>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="|">
<mml:mrow>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="|">
<mml:mrow>
<mml:mfrac>
<mml:mi>A</mml:mi>
<mml:mrow>
<mml:mn>1</mml:mn>
<mml:mo>&#x2b;</mml:mo>
<mml:mi>k</mml:mi>
<mml:mi>s</mml:mi>
<mml:mi>v</mml:mi>
<mml:mo>&#x2a;</mml:mo>
<mml:mi>p</mml:mi>
<mml:mi>O</mml:mi>
<mml:mn>2</mml:mn>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:mo>&#x2b;</mml:mo>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="|">
<mml:mrow>
<mml:mn>1</mml:mn>
<mml:mo>&#x2212;</mml:mo>
<mml:mi>A</mml:mi>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:mrow>
<mml:mo>&#x2212;</mml:mo>
<mml:mn>1</mml:mn>
</mml:mrow>
</mml:msup>
</mml:mrow>
</mml:math>
<label>(1)</label>
</disp-formula>
</p>
<p>R is the measured luminescence ratio, R<sub>0</sub> is the luminescence ratio at 0% O<sub>2</sub>, <italic>ksv</italic> is the Stern-Volmer constant indicating the efficiency of oxygen quenching, and A is 0.82, a parameter for the non-linearity of the sensing material (<xref ref-type="bibr" rid="B32">Peniche Silva et al., 2020</xref>). The ksv was computed using the two-point calibration described in the Methods, and a time-dependent ksv was applied at the beginning of the recordings to account for temperature changes. Eq. <xref ref-type="disp-formula" rid="e1">1</xref> was linear for the limited range of oxygenation, that is, typical for cell cultures (&#x3c;20%, <xref ref-type="fig" rid="F2">Figure 2E</xref>). However, when measured over a full range of 0%&#x2013;100% oxygen concentration, the inverse Stern-Volmer is expected to follow a decaying exponential function (<xref ref-type="bibr" rid="B42">Wang et al., 2010</xref>).</p>
</sec>
<sec id="s3-2">
<title>3.2 High-throughput compatibility</title>
<p>The semicircular oxygen sensors covered half of each well in a 96-well glass bottom plate (<xref ref-type="fig" rid="F1">Figures 1C</xref>, D). This feature enabled multiparametric optical high-throughput measurements from the other half of each well. Such measurements include cellular action potentials, intracellular calcium transients, and contractility (<xref ref-type="bibr" rid="B21">Klimas et al., 2020</xref>; <xref ref-type="bibr" rid="B12">Heinson et al., 2023</xref>; <xref ref-type="bibr" rid="B30">Liu et al., 2023</xref>). Laser cutting of the sensors was quick and reproducible (<xref ref-type="fig" rid="F1">Figure 1E</xref>), where more than 96 half-moon sensors could be cut in less than 10&#xa0;min. Subsequent attachment of the sensors in each well of a 96 well plate could be completed in less than 1&#xa0;hour. Laser cutting had a negligible effect on sensor performance and provided sufficient sensor area for good ratiometric measurements after selecting a region of interest from each sensor. We found that it is essential to keep the pre-cut sensors in the dark and to use them within 6&#xa0;months of laser cutting for best results. Sterilization of the sensors with ethanol for cellular experiments did not affect their performance.</p>
</sec>
<sec id="s3-3">
<title>3.3 System characterization and validation</title>
<p>The RGB images of the entire plate (1280 &#xd7; 1024 pixels, 24bit) acquired by the VisiSensTD system provided sufficient contrast with approximately 1000 pixels per sensor, and 300 to 700 pixels per sensor region of interest (<xref ref-type="fig" rid="F1">Figure 1E</xref>, middle). After calibration, the pseudocolor images of the plate clearly denoted differences in oxygenation between wells. In the example shown in <xref ref-type="fig" rid="F1">Figure 1E</xref>, right, the quadrants of the plate were conditioned with 0% air-saturated PBS (top left), 100% air-saturated PBS (top right), room air (bottom left), and 100% air-saturated PBS with pH &#x3d; 4 (bottom right). We found that solution pH had negligible influence on calibrated oxygen sensor values. The oxygen sensors also reacted differently in air than when submerged in solution.</p>
<p>Spectral characterization of the optical oxygen sensors and validation of the oxygen measurements with Clark electrodes confirmed that small changes in peri-cellular oxygen concentration could be accurately measured in 96-well plates (<xref ref-type="fig" rid="F2">Figure 2</xref> and <xref ref-type="fig" rid="F3">Figure 3</xref>). The Presens oxygen sensors (SF-RPsSU4) had a peak emission of 653&#xa0;nm upon excitation with 409&#xa0;nm light, and this emission decreased in response to increased oxygen concentration (<xref ref-type="fig" rid="F2">Figure 2B</xref>), demonstrating dynamic ruthenium fluorescence quenching by oxygen (<xref ref-type="bibr" rid="B43">Wang and Wolfbeis, 2014</xref>; <xref ref-type="bibr" rid="B45">Wolff et al., 2019</xref>). Increased fluorescence in the green band (485&#x2013;570&#xa0;nm) was also measured from the sensors upon illumination with 409&#xa0;nm light (<xref ref-type="fig" rid="F2">Figure 2D</xref>), with a midpoint of 510&#xa0;nm. The intensity of this band did not change when oxygen concentration increased, corresponding to the oxygen insensitive reference dye that Presens has added to the sensor material. These controlled spectral measurements in a 96-well plate using our HT-&#xb5;UPS system confirmed adequate spectral sensitivity of the sensors for the range of peri-cellular oxygen that is expected for cell cultures (&#x3c;18.6%). The relationship of the ratio of red to green emission intensity was linear (<xref ref-type="fig" rid="F2">Figure 2E</xref>), as predicted by Eq. <xref ref-type="disp-formula" rid="e1">1</xref>.</p>
<p>A recent study cross-validated VisiSensTD peri-cellular oxygen measurements using a fiber-optics oxygen microelectrode (<xref ref-type="bibr" rid="B32">Peniche Silva et al., 2020</xref>). In contrast, we used in-line Clark electrodes to validate the measurement of peri-cellular oxygen using laser-cut semicircular sensors, the VisiSensTD system, and physiological flow rates through our HT-&#xb5;UPS system in a 96-well plate (<xref ref-type="fig" rid="F3">Figure 3A</xref>). Our system demonstrated appropriate responsiveness to changes in media oxygen concentration and flow. During a 30&#xa0;min recording, media flow began at 500&#xa0;ml/min, was reduced to 200&#xa0;ml/min, and then restored to 500&#xa0;ml/min (<xref ref-type="fig" rid="F3">Figure 3A</xref>). Oxygen values from the Clark electrode positioned at the inlet of the plate indicated that media oxygenation was near 100% and remained constant (<xref ref-type="fig" rid="F3">Figure 3B</xref>). Oxygen values from the Clark electrode positioned after the plate aligned with values measured optically from the sensor at the bottom of the first well. The diameter and length of tubing and the time of the peak oxygen value (85%) measured at the bottom of the well (<xref ref-type="fig" rid="F3">Figure 3C</xref>, green line) corresponded to the flow rate of 500&#xa0;ml/min. The drop in oxygenation at 200&#xa0;ml/min indicated a loss of oxygen as the media traveled more slowly through the connection at the entrance of the HT-&#xb5;UPS cover.</p>
</sec>
<sec id="s3-4">
<title>3.4 Optimal exposure time</title>
<p>Excitation light was not uniformly distributed across the bottom of 96-well plates. This increased the spatial variance (well-to-well differences) of red:green emission ratios from the sensors for short excitation light exposure times. The dependence of sensor emission ratio variability on illumination exposure times between 0.15 and 1.5&#xa0;s was measured to identify exposure times where spatial variation was minimized (<xref ref-type="fig" rid="F4">Figure 4A</xref>). Spatial variation was highest for exposure times less than 0.4&#xa0;s. Spatial variation was lowest for exposure times between 0.4 and 0.9&#xa0;s. An optimal exposure time of 0.8&#xa0;s was chosen within this range as a duration for the follow up experiments. The red:green ratio for different wells of a 96-well plate for an exposure time of 0.8&#xa0;s at two levels of oxygenation (0% and 100% air-saturation) and 2&#xa0;cell culture media (hiPSC-CMs and cardiac fibroblast) varied within &#xb1;6% (<xref ref-type="fig" rid="F4">Figures 4B, C</xref>). The standard deviation for hiPSC-CM media was 6% and 2%, for Cal0 and Cal100, respectively; the standard deviation for cardiac fibroblasts media was 3.5% and 1.7% for Cal0 and Cal100, respectively. This variability was much lower than the typical variability between experimental groups of cultured cells.</p>
<fig id="F4" position="float">
<label>FIGURE 4</label>
<caption>
<p>Influence of exposure time on ratio readouts and their spatial spread in a 96-well plate. <bold>(A)</bold>. Oxygen readout (ratio values) spread across the 96-well plate as exposure time varies between 0.15 and 1.5&#xa0;s, dot plots and mean &#xb1; SD. To minimize the spread, exposure was chosen in the 0.4&#x2013;0.9&#xa0;s range. <bold>(B)</bold>. Spatial variation across the 96-well plate with 0% oxygen (Cal0), blue, and air saturated (Cal100) oxygen for culture medium used to grow human cardiac myocytes, CM (top), and human cardiac fibroblasts, cFB (bottom). 5% Na<sub>2</sub>SO<sub>3</sub> in the medium was used for 0% oxygen calibration; exposure time set to 0.8&#xa0;s.</p>
</caption>
<graphic xlink:href="fbioe-11-1214493-g004.tif"/>
</fig>
</sec>
<sec id="s3-5">
<title>3.5 Temperature effect and time-dependent system calibration</title>
<p>Temperature had a significant effect on the red:green emission ratio for each sensor, which was evident after placing a 96-well plate at room temperature in the incubator maintained at 37&#xb0;C. The effect of temperature on emission ratio, as a plate was warmed to 37&#xb0;C, was measured over 4&#xa0;h after placing a plate in the incubator (<xref ref-type="fig" rid="F5">Figure 5A</xref>). Wells contained media for hiPSC-CMs or media for cardiac fibroblasts, and wells had an oxygen level of either 0% or 100% air-saturation. Oxygen images were acquired every 5&#xa0;min. The average red:green ratio for each combination of media and oxygenation changed over the first 40&#x2013;90&#xa0;min (40&#xa0;min for the cFB media and 90&#xa0;min for the hiPSC-CM media) (<xref ref-type="fig" rid="F5">Figure 5A</xref>). Ratios for wells having media at 100% air-saturation were similar throughout the 4&#xa0;h and changed approximately 10% in the first hour. Ratios for wells having media at 0% changed as much as 60% in the first 2&#xa0;hours and the change was greater for wells with fibroblast media. This result was likely due to differences in the content of the two types of media. The Stern-Volmer <italic>ksv</italic> values (Eq. <xref ref-type="disp-formula" rid="e1">1</xref>) computed from the ratios for wells having media at 0% also varied within the first 40&#x2013;90&#xa0;min (<xref ref-type="fig" rid="F5">Figure 5A</xref>, inset). These results necessitated the development of a protocol to correct for the effect of changes in well temperature as a plate was warmed to 37&#xb0;C and for the effect of cell culture media content that determines media color.</p>
<fig id="F5" position="float">
<label>FIGURE 5</label>
<caption>
<p>Time-dependent calibration, effects of pH and medium color on the oxygen readings. <bold>(A)</bold>. Time-dependent calibration over 4&#xa0;h, done in culture medium for human cFBs and human iPSC-CMs in a 37&#xb0;C cell culture incubator, <italic>n</italic> &#x3d; 96 wells. Over the first 40&#x2013;90 min, there is a temperature-dependent rise in the ratio reading for the Cal0 values. Inset shows that the derived Stern-Volmer coefficient, KSV, varies in this initial period for both culture media. <bold>(B)</bold>. Time-dependent calibration changes of CM medium with different pH &#x3d; 4, 7.4 (standard) and 10. Oxygen readouts were continuously recorded for an hour in 5&#xa0;min intervals. The mean ratio of air-saturated CM medium with standard and altered pH was plotted over time (mean &#xb1; SD, <italic>n</italic> &#x3d; 12&#x2013;24 samples). <bold>(C)</bold>. Same as <bold>(B)</bold>, but for cFB culture medium. <bold>(D)</bold>. Full 96-well plate characterization of medium color and pH&#x2019;s influence on oxygen reading. Conditions are listed in the plate layout. Although pH visibly altered culture medium color (bottom-up view), the analyzed oxygen data were not influenced by medium color or pH difference.</p>
</caption>
<graphic xlink:href="fbioe-11-1214493-g005.tif"/>
</fig>
</sec>
<sec id="s3-6">
<title>3.6 Effects of media color and pH</title>
<p>The substrate, salt, and chemical content of the hiPSC-CM media and the cardiac fibroblast media were different, resulting in each culture media having a distinct color. Media pH also determines media color and changes in pH could have an independent effect on sensor luminescence. The effect of media color and pH on sensor emission ratio was studied using 96-well plates and the VisiSensTD system. Wells contained either PBS, hiPSC-CM media, or cardiac fibroblast media and the pH of each well was set to be either 4 or 10 (<xref ref-type="fig" rid="F5">Figure 5B</xref>, plate layout). Differences in the color of the media in each well were clearly visible (<xref ref-type="fig" rid="F5">Figure 5B</xref>, bottom-up plate view). However, color differences were not evident in images of the emission ratio (<xref ref-type="fig" rid="F5">Figure 5B</xref>, raw oxygen data). Color differences were also not evident in pseudocolor images after computing the percent oxygen concentration of each well using the emission ratios (<xref ref-type="fig" rid="F5">Figure 5B</xref>, analyzed oxygen data). To determine if pH had a direct effect on sensor luminescence, the emission ratio of each media having 100% air-saturation at standard pH of 7 or a pH of 4 or 10 was measured once every 5&#xa0;min for 1&#xa0;hour using the VisiSensTD system (<xref ref-type="fig" rid="F5">Figures 5C</xref>, D). No significant difference was detected between media having a pH of 7 and 4. The emission ratio was consistently lower for media having a pH of 10, which is highly alkaline and has less biological relevance for cell culture experiments.</p>
</sec>
<sec id="s3-7">
<title>3.7 Long-term monitoring of peri-cellular oxygen concentration in cardiac cells</title>
<p>After validation, characterization, and the development of a robust calibration protocol, the VisiSensTD oxygen imaging system was used to continuously measure peri-cellular oxygen concentration from cardiac cells cultured in a 96-well plate. Using an upright microscope with a water-immersion objective, we confirmed that human iPSC-CMs formed a dense cellular syncytium on top of the oxygen sensors after coating with fibronectin (<xref ref-type="fig" rid="F6">Figure 6A</xref>, lower image). The transparent half of the glass-bottom of each well that was not covered by a sensor enabled human iPSC-CMs and human cardiac fibroblasts to be monitored to confirm healthy growth. This corroborated no adverse effects of the sensors as cells thrived as a syncytium equally well on top of each sensor and on the glass-bottom portion of the well that was not covered by a sensor. In monitoring cell function over several days, we confirmed that sensor readouts were stable and did not alter cell growth. Typical images of human iPSC-CMs and human cFBs grown on fibronectin-coated glass-bottom portion are shown in <xref ref-type="fig" rid="F6">Figure 6A</xref>, upper image and <xref ref-type="fig" rid="F6">Figure 6C</xref>, respectively. Studies were conducted for time intervals ranging from 24 to 48&#xa0;h (<xref ref-type="fig" rid="F6">Figure 6</xref>). In one experiment, peri-cellular oxygen was measured every 10&#xa0;min over 48&#xa0;h from hiPSC-CMs plated in every other row of a 96-well plate (<xref ref-type="fig" rid="F6">Figure 6A</xref>). Two control wells had oxygen sensors and media but no cells. Peri-cellular oxygen dropped dramatically to &#x3c;5% within 10&#xa0;h in all wells that had cells. Oxygen concentration in control wells was constant at 18.6%, corresponding to the equilibration of the media with the incubator oxygen concentration. In wells having cells, two patterns of peri-cellular oxygen dynamics emerged after 10&#xa0;h (<xref ref-type="fig" rid="F6">Figure 6B</xref>): one of monotonic oxygen depletion and another of intermittent depletion. In cases of monotonic depletion, after the initial oxygen drop to &#x3c;5%, peri-cellular oxygen monotonically and slowly decreased to a steady-state level. In intermittent depletion, peri-cellular oxygen oscillated intermittently after the initial oxygen drop. For the results shown in <xref ref-type="fig" rid="F6">Figure 6B</xref>, monotonic depletion was observed in 11 out of 38 wells (29%) and intermittent depletion occurred in 27 out of 38 wells (71%). Oscillatory intermittent depletion occurred in different wells within the rows of a plate, confirming that oxygen dynamics were independent of the position of a well within a plate.</p>
<fig id="F6" position="float">
<label>FIGURE 6</label>
<caption>
<p>Optical measurements of peri-cellular oxygen in human iPSC-cardiomyocytes and human cardiac fibroblasts, cFBs. <bold>(A)</bold>. Full plate hiPSC-CM oxygen measurement plate layout and still images of hiPSC-CMs grown on glass bottom half of the well (upper image) and on the oxygen sensor (lower image). In the upper image, the hiPSC-CMs grown on glass were antibody-labeled for alpha-actinin (red), nuclei were labeled using Hoechst dye (blue). The lower image of hiPSC-CMs growing on top of the oxygen sensors, were collected using an upright microscope with a water immersion lens; the eYFP signal from channelrhodopsin2-eYFP infected cardiomyocytes is shown. <bold>(B)</bold>. Continuous optical sensing of peri-cellular O<sub>2</sub> in human iPSC-CMs over 48&#xa0;h. Peri-cellular oxygen levels dropped to &#x3c;5% in &#x3c;10&#xa0;h for most samples. Two types of hypoxia responses were seen: (1) monotonic O<sub>2</sub> depletion to a steady state, and (2) intermittent O<sub>2</sub> dynamics after an O<sub>2</sub> dip below 5% (black arrows). Type 1 was observed in about 30% of the samples in this plate, while type 2 was observed in the remaining 70% of the measured <italic>n</italic> &#x3d; 40 wells. The specific type of response was independent of spatial location&#x2014;traces from the four different rows in the plate having samples are shown (rows A, C, E, G). 18.6% oxygenation corresponds to the maximum (100%) oxygen saturation in a CO<sub>2</sub> incubator. <bold>(C)</bold>. Experimental design of hiPSC-CM and cFBs hypoxia study, and still image of cFBs on the glass bottom portion of a well. F-actin (green) highlights the cytoskeleton of the cells, and nuclei (Hoechst labeled) are indicated in blue. <bold>(D)</bold>. Example images and calibrated traces of hiPSC-CMs and cFB peri-cellular O<sub>2</sub> over 24h, under normoxic and hypoxic conditions. Peri-cellular O<sub>2</sub> in cFBs decreased slower and stabilized to a higher steady-state level; induced hypoxia (filling the wells with solution to the top and sealing them) sped up the O<sub>2</sub> depletion in cFB. The hiPSC-CMs showed rapid depletion of O<sub>2</sub> within 6&#xa0;h with a faster initial phase of drop in the sealed samples, which then bounced back to slightly higher steady-state values.</p>
</caption>
<graphic xlink:href="fbioe-11-1214493-g006.tif"/>
</fig>
<p>Dynamic patterns of peri-cellular oxygen were studied in cardiac fibroblast and hiPSC-CM cultures over 24&#xa0;h to determine if depletion occurs more rapidly in cells having higher metabolic rate (<xref ref-type="fig" rid="F6">Figures 6C</xref>, D). Depletion was hypothesized to occur more rapidly in hiPSC-CM cultures due to the higher oxygen consumption of contracting cells. The two cell types were cultured in separate sets of six wells of the same plate. Two of those wells were filled with the typical 200&#xa0;ml of media to provide normoxia while the other four wells were filled with 300&#xa0;ml of media and sealed with oxygen-impermeable tape to generate hypoxia (<xref ref-type="fig" rid="F6">Figure 6C</xref>). Peri-cellular oxygen was depleted within 6&#xa0;h for normoxic and hypoxic cultures of hiPSC-CMs. Oxygen depletion was much slower for fibroblasts, where over 24&#xa0;h oxygen did not drop below 10% for normoxic cultures and most hypoxic cultures maintained an oxygen level above 5% (<xref ref-type="fig" rid="F6">Figure 6D</xref>). These results confirm the hypothesis and also demonstrate the utility of optical oxygen sensing in providing long-term measurements that reveal cell-type differences in the baseline and fluctuations of peri-cellular oxygen concentration.</p>
</sec>
</sec>
<sec sec-type="discussion" id="s4">
<title>4 Discussion</title>
<p>Oxygen consumption and defense mechanisms against hypo-/hyperoxia are critical to sustaining life, as O<sub>2</sub> is a key component of energy (ATP) production in the mitochondria. However, when in excess, oxygen is inherently toxic due to its chemical reactivity and the generation of reactive oxygen species (ROS) (<xref ref-type="bibr" rid="B16">Keeley and Mann, 2019</xref>). Although the need for measuring peri-cellular oxygen levels in cell culture has been recognized since at least 1970 (<xref ref-type="bibr" rid="B16">Keeley and Mann, 2019</xref>), doing so is not routine in cell culture studies.</p>
<p>Recent developments have included scalable solutions to control dissolved (bulk) oxygen levels in custom-designed 96-well plates. For example, in one study the well bottoms of a 96-well plate were modified to use special actuation posts, driven by magnetic field to increase oxygen availability (<xref ref-type="bibr" rid="B6">Fisher et al., 2021</xref>). In other studies, elegant microfluidics-based solutions with concentration gradients have been deployed to control dissolved oxygen levels in custom-designed 96-well plates with oxygen-permeable bottom (<xref ref-type="bibr" rid="B48">Yao et al., 2018</xref>; <xref ref-type="bibr" rid="B49">Yao et al., 2021</xref>). Fiber-optic probe was used to perform sequential measurements in different wells and confirm oxygen levels close to the well bottom, which for cells with low metabolic needs may approach peri-cellular oxygen levels.</p>
<p>In bacterial cell culture applications, more advanced high-throughput monitoring solutions have been implemented. For example, oxygen-sensing fluorophores have been embedded in hydrogel inserts to monitor dissolved oxygen levels in custom 96-well plates up to several hours (<xref ref-type="bibr" rid="B46">Wu et al., 2018</xref>). Another bacterial cell culture study monitored peri-cellular oxygen by methods similar to the ones reported here, including the use of a commercial 96-well OxoPlate by Presens (<xref ref-type="bibr" rid="B10">Glauche et al., 2015</xref>). In one variant, circular sensor patches were cut and glued in standard 96-well plates; a robotic arm was moving the plate between a shaker and a plate reader to track oxygen levels as function of shaking speeds to optimize microbial culture conditions. Because of the discontinuous readouts, the study purposefully sought to develop oxygen sensors with slower response time than the ones deployed here. OxoPlate (Presens) was also used to study antibiotic resistance in microbial cell culture based on longitudinal tracking of peri-cellular oxygen (<xref ref-type="bibr" rid="B1">Almatrood et al., 2022</xref>).</p>
<p>Overall, high-throughput peri-cellular oxygen measurements in mammalian cell culture are rare, and no long-term measurements are available from cultures of human iPSC-CMs. A major obstacle has been the lack of user-friendly monitoring systems and reliable non-invasive methods for long-term oxygen monitoring in common cell culture formats such as 96-well plates.</p>
<p>In this study, the Presens ratiometric optical oxygen sensors and camera-based imaging system were adopted to track peri-cellular oxygen dynamics in human cardiac cells cultured in glass-bottom 96-well plates. We developed a scalable technique for reproducible cutting and positioning of semicircular optical oxygen sensors into glass-bottom HT plates (<xref ref-type="fig" rid="F1">Figure 1</xref>), to cover half of each well, leaving the other half for multimodal structural and functional imaging. We validated the optical oxygen readings with traditional Clark electrodes positioned in line in bulk measurements and during perfusion within 96 wells using our specialized microfluidics-based cover. The spectral, spatial, and temporal properties of the system were systematically characterized (<xref ref-type="fig" rid="F2">Figures 2</xref>&#x2013;<xref ref-type="fig" rid="F4">4</xref>). Optimization of the exposure time and the two-point calibration (<xref ref-type="fig" rid="F4">Figures 4</xref>, <xref ref-type="fig" rid="F5">5</xref>) allowed continuous oxygen measurements in a standard incubator that were robust and reliable.</p>
<p>Compared to prior studies, the following new and useful aspects are demonstrated here: 1) to our knowledge, this is the first mammalian culture study to track long-term peri-cellular oxygen in standard glass-bottom 96-well plates, that are the industry standard and are used in preclinical testing; 2) the first study to do so in human cardiomyocytes over long term, with continuous frequent sampling of peri-cellular oxygen levels during cell growth in a standard cell culture incubator, providing novel insights on cardiomyocyte oxygen consumption dynamics; 3) our approach in using half of each well for optical oxygen sensing (semicircular sensors) allows multimodal structural and functional observations in the same samples through the transparent glass bottom part, compatible with standard microscopy and with all-optical electrophysiology systems.</p>
<p>Our results are in agreement with <italic>in vivo</italic> estimates of peri-cellular oxygen levels in the heart, where oxygen tension in the immediate vicinity of the cardiomyocytes is in the range of 3%&#x2013;6% (<xref ref-type="bibr" rid="B16">Keeley and Mann, 2019</xref>). Namely, for human iPSC-CMs, in the static culture conditions of a glass-bottom 96-well plate, we observed a drop to &#x3c;5% oxygen within several hours of media exchange. After this initial drop, the cells either settled to a steady state of low pericellular oxygen, likely due to the balance between active oxygen consumption and passive diffusion, or exhibited an intermittent oxygen dynamics (<xref ref-type="fig" rid="F6">Figure 6</xref>). These two types of responses are interesting novel observations and require further investigation. In contrast to the cardiomyocytes, the non-contracting cardiac fibroblasts exhibited higher peri-cellular oxygen levels after dropping to a stable steady-state, as expected for cells with lower oxygen demand.</p>
<p>
<italic>In vivo</italic>, cardiac cell normoxia is maintained by feedback mechanisms that tightly regulate coronary blood (<xref ref-type="bibr" rid="B13">Hoffman and Buckberg, 2014</xref>) and by oxygen-on-demand provided by the excellent oxygen carrying capacity of hemoglobin. <italic>Ex vivo</italic>, in the absence of adequate oxygen buffering, perfused working hearts experience hypoxic conditions (<xref ref-type="bibr" rid="B7">Garrott et al., 2017</xref>; <xref ref-type="bibr" rid="B26">Kuzmiak-Glancy et al., 2018</xref>). <italic>In vitro</italic>, cardiomyocytes may experience hyperoxic, normoxic or hypoxic conditions (<xref ref-type="bibr" rid="B16">Keeley and Mann, 2019</xref>) depending on their density, electromechanical activity, mass transport conditions and the shortest path to the ambient oxygen supply. For human iPSC-CMs, oxygen tension was recognized in early work as a key variable for optimizing cellular differentiation and maturation; transient control of oxygen level is used during the differentiation of iPS cells into cardiomyocytes (<xref ref-type="bibr" rid="B28">Lian et al., 2015</xref>; <xref ref-type="bibr" rid="B31">Lyra-Leite et al., 2022</xref>). Hypoxia signaling is also a foundational physiologic component of mature cardiomyocytes, where it intimately regulates electromechanical function, including ion channel currents and protein expression (<xref ref-type="bibr" rid="B17">Keeley et al., 2018</xref>; <xref ref-type="bibr" rid="B16">Keeley and Mann, 2019</xref>; <xref ref-type="bibr" rid="B33">Pressler et al., 2022</xref>). Based on this, longitudinal label-free monitoring of peri-cellular oxygen, in a high-throughput manner, provides unique insights into the metabolic state of the cells, and potentially can be correlated with their level of maturation.</p>
<p>The system described here is best suited for imaging the oxygen concentration of two-dimensional multi-cell structures, such as monolayers. This is a limitation, considering the growing popularity of three-dimensional cell constructs, including cell spheroids and microtissues. A potential way to extend the described label-free oxygen sensing approach to 3D structures is inspired by the recent work of others, where optical sensors have been mounted on transparent prisms (<xref ref-type="bibr" rid="B32">Peniche Silva et al., 2020</xref>) and oxygen-sensing cell culture vessels have been thermoform-molded to line the wells of spheroidal plates (<xref ref-type="bibr" rid="B11">Gr&#xfc;n et al., 2023</xref>). Future work includes automating the placement of sensors into 96-well plates using the scalable technique described and manually demonstrated here. Combination of the high-throughput monitoring of peri-cellular oxygen with microfluidics-based solutions of controlling oxygenation (<xref ref-type="bibr" rid="B44">Wei et al., 2020</xref>; <xref ref-type="bibr" rid="B49">Yao et al., 2021</xref>) can yield feedback-controlled growth environment for cardiac tissue engineering. Coupling label-free measurements of peri-cellular oxygen with label-free measurements of cardiac electromechanical waves (<xref ref-type="bibr" rid="B30">Liu et al., 2023</xref>) will also provide valuable insights into the interplay between cellular activity and oxygenation state.</p>
</sec>
</body>
<back>
<sec sec-type="data-availability" id="s5">
<title>Data availability statement</title>
<p>The original contributions presented in the study are included in the article/Supplementary Material, further inquiries can be directed to the corresponding authors.</p>
</sec>
<sec id="s6">
<title>Author contributions</title>
<p>WL and DM contributed equally to this work and share the first authorship. WL was responsible for all cell-based experiments and analysis, developed the calibration procedure and contributed to the writing of the first draft. DM developed the laser cutting and sensor mounting procedure, the microfluidic cover, conducted characterization experiments with the Clark electrodes and wrote parts of the first draft. JK did the initial system setup, testing and optimization. JK, DM, and GK conducted spectral characterization and validation experiments, RR assisted in the experiments and writing. EE took the lead on the manuscript writing, with input from all authors. ZL, MK, and EE developed the concept, and experimental design, oversaw the project, and secured funding; they share senior authorship. All authors contributed to the article and approved the submitted version.</p>
</sec>
<sec id="s7">
<title>Funding</title>
<p>This work was supported in part by grants from the NIH-NHLBI R01HL144157 and from the NSF EFMA1830941.</p>
</sec>
<sec sec-type="COI-statement" id="s8">
<title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec sec-type="disclaimer" id="s9">
<title>Publisher&#x2019;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<ref-list>
<title>References</title>
<ref id="B1">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Almatrood</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Nakouti</surname>
<given-names>I.</given-names>
</name>
<name>
<surname>Hobbs</surname>
<given-names>G.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Microtiter plate with built-in oxygen sensors: A novel approach to investigate the dynamics of <italic>Pseudomonas aeruginosa</italic> growth suppression in the presence of divalent cations and antibiotics</article-title>. <source>Archives Microbiol.</source> <volume>204</volume>, <fpage>297</fpage>. <pub-id pub-id-type="doi">10.1007/s00203-022-02877-y</pub-id>
</citation>
</ref>
<ref id="B2">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Divakaruni</surname>
<given-names>A. S.</given-names>
</name>
<name>
<surname>Rogers</surname>
<given-names>G. W.</given-names>
</name>
<name>
<surname>Murphy</surname>
<given-names>A. N.</given-names>
</name>
</person-group> (<year>2014</year>). <article-title>Measuring mitochondrial function in permeabilized cells using the Seahorse XF analyzer or a clark-type oxygen electrode</article-title>. <source>Curr. Protoc. Toxicol.</source> <volume>60</volume>, <fpage>1</fpage>&#x2013;<lpage>16</lpage>. <pub-id pub-id-type="doi">10.1002/0471140856.tx2502s60</pub-id>
</citation>
</ref>
<ref id="B3">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Burridge</surname>
<given-names>P. W.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>Y. F.</given-names>
</name>
<name>
<surname>Matsa</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Wu</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Ong</surname>
<given-names>S. G.</given-names>
</name>
<name>
<surname>Sharma</surname>
<given-names>A.</given-names>
</name>
<etal/>
</person-group> (<year>2016</year>). <article-title>Human induced pluripotent stem cell-derived cardiomyocytes recapitulate the predilection of breast cancer patients to doxorubicin-induced cardiotoxicity</article-title>. <source>Nat. Med.</source> <volume>22</volume>, <fpage>547</fpage>&#x2013;<lpage>556</lpage>. <pub-id pub-id-type="doi">10.1038/nm.4087</pub-id>
</citation>
</ref>
<ref id="B4">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Chen</surname>
<given-names>I. Y.</given-names>
</name>
<name>
<surname>Matsa</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Wu</surname>
<given-names>J. C.</given-names>
</name>
</person-group> (<year>2016</year>). <article-title>Induced pluripotent stem cells: At the heart of cardiovascular precision medicine</article-title>. <source>Nat. Rev. Cardiol.</source> <volume>13</volume>, <fpage>333</fpage>&#x2013;<lpage>349</lpage>. <pub-id pub-id-type="doi">10.1038/nrcardio.2016.36</pub-id>
</citation>
</ref>
<ref id="B5">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Clark</surname>
<given-names>L. C.</given-names>
</name>
</person-group> (<year>1956</year>). <article-title>Monitor and control of blood and tissue oxygen tensions</article-title>. <source>Asaio J.</source> <volume>2</volume>, <fpage>41</fpage>&#x2013;<lpage>48</lpage>.</citation>
</ref>
<ref id="B6">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Fisher</surname>
<given-names>J. T.</given-names>
</name>
<name>
<surname>Gurney</surname>
<given-names>T. O.</given-names>
</name>
<name>
<surname>Mason</surname>
<given-names>B. M.</given-names>
</name>
<name>
<surname>Fisher</surname>
<given-names>J. K.</given-names>
</name>
<name>
<surname>Kelly</surname>
<given-names>W. J.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Mixing and oxygen transfer characteristics of a microplate bioreactor with surface-attached microposts</article-title>. <source>Biotechnol. J.</source> <volume>16</volume>, <fpage>2000257</fpage>. <pub-id pub-id-type="doi">10.1002/biot.202000257</pub-id>
</citation>
</ref>
<ref id="B7">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Garrott</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Kuzmiak-Glancy</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Wengrowski</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Rogers</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Kay</surname>
<given-names>M. W.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>K<sub>ATP</sub>channel inhibition blunts electromechanical decline during hypoxia in left ventricular working rabbit hearts: K<sub>ATP</sub>channel inhibition during hypoxia in LV working rabbit hearts</article-title>. <source>J. physiology</source> <volume>595</volume>, <fpage>3799</fpage>&#x2013;<lpage>3813</lpage>. <pub-id pub-id-type="doi">10.1113/jp273873</pub-id>
</citation>
</ref>
<ref id="B8">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Gerencser</surname>
<given-names>A. A.</given-names>
</name>
<name>
<surname>Neilson</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Choi</surname>
<given-names>S. W.</given-names>
</name>
<name>
<surname>Edman</surname>
<given-names>U.</given-names>
</name>
<name>
<surname>Yadava</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Oh</surname>
<given-names>R. J.</given-names>
</name>
<etal/>
</person-group> (<year>2009</year>). <article-title>Quantitative microplate-based respirometry with correction for oxygen diffusion</article-title>. <source>Anal. Chem.</source> <volume>81</volume>, <fpage>6868</fpage>&#x2013;<lpage>6878</lpage>. <pub-id pub-id-type="doi">10.1021/ac900881z</pub-id>
</citation>
</ref>
<ref id="B9">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Gintant</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Burridge</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Gepstein</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Harding</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Herron</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Hong</surname>
<given-names>C.</given-names>
</name>
<etal/>
</person-group> (<year>2019</year>). <article-title>Use of human induced pluripotent stem cell-derived cardiomyocytes in preclinical cancer drug cardiotoxicity testing: A scientific statement from the American heart association</article-title>. <source>Circ. Res.</source> <volume>125</volume>, <fpage>e75</fpage>&#x2013;<lpage>e92</lpage>. <pub-id pub-id-type="doi">10.1161/res.0000000000000291</pub-id>
</citation>
</ref>
<ref id="B10">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Glauche</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>John</surname>
<given-names>G. T.</given-names>
</name>
<name>
<surname>Arain</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Knepper</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Neubauer</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Goelling</surname>
<given-names>D.</given-names>
</name>
<etal/>
</person-group> (<year>2015</year>). <article-title>Toward microbioreactor arrays: A slow-responding oxygen sensor for monitoring of microbial cultures in standard 96-well plates</article-title>. <source>J. laboratory automation</source> <volume>20</volume>, <fpage>438</fpage>&#x2013;<lpage>446</lpage>. <pub-id pub-id-type="doi">10.1177/2211068215573924</pub-id>
</citation>
</ref>
<ref id="B11">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Gr&#xfc;n</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Pfeifer</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Liebsch</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Gottwald</surname>
<given-names>E.</given-names>
</name>
</person-group> (<year>2023</year>). <article-title>O(2)-sensitive microcavity arrays: A new platform for oxygen measurements in 3D cell cultures</article-title>. <source>Front. Bioeng. Biotechnol.</source> <volume>11</volume>, <fpage>1111316</fpage>. <pub-id pub-id-type="doi">10.3389/fbioe.2023.1111316</pub-id>
</citation>
</ref>
<ref id="B12">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Heinson</surname>
<given-names>Y. W.</given-names>
</name>
<name>
<surname>Han</surname>
<given-names>J. L.</given-names>
</name>
<name>
<surname>Entcheva</surname>
<given-names>E.</given-names>
</name>
</person-group> (<year>2023</year>). <article-title>Portable low-cost macroscopic mapping system for all-optical cardiac electrophysiology</article-title>. <source>J. Biomed. Opt.</source> <volume>28</volume>, <fpage>016001</fpage>. <pub-id pub-id-type="doi">10.1117/1.jbo.28.1.016001</pub-id>
</citation>
</ref>
<ref id="B13">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hoffman</surname>
<given-names>J. I. E.</given-names>
</name>
<name>
<surname>Buckberg</surname>
<given-names>G. D.</given-names>
</name>
</person-group> (<year>2014</year>). <article-title>The myocardial oxygen supply:demand index revisited</article-title>. <source>J. Am. Heart Assoc.</source> <volume>3</volume>, <fpage>e000285</fpage>. <pub-id pub-id-type="doi">10.1161/jaha.113.000285</pub-id>
</citation>
</ref>
<ref id="B14">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Invernizzi</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>D&#x27;Amato</surname>
<given-names>I.</given-names>
</name>
<name>
<surname>Jensen</surname>
<given-names>P. B.</given-names>
</name>
<name>
<surname>Ravaglia</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Zeviani</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Tiranti</surname>
<given-names>V.</given-names>
</name>
</person-group> (<year>2012</year>). <article-title>Microscale oxygraphy reveals OXPHOS impairment in MRC mutant cells</article-title>. <source>Mitochondrion</source> <volume>12</volume>, <fpage>328</fpage>&#x2013;<lpage>335</lpage>. <pub-id pub-id-type="doi">10.1016/j.mito.2012.01.001</pub-id>
</citation>
</ref>
<ref id="B15">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Karbassi</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Fenix</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Marchiano</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Muraoka</surname>
<given-names>N.</given-names>
</name>
<name>
<surname>Nakamura</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Yang</surname>
<given-names>X.</given-names>
</name>
<etal/>
</person-group> (<year>2020</year>). <article-title>Cardiomyocyte maturation: Advances in knowledge and implications for regenerative medicine</article-title>. <source>Nat. Rev. Cardiol.</source> <volume>17</volume>, <fpage>341</fpage>&#x2013;<lpage>359</lpage>. <pub-id pub-id-type="doi">10.1038/s41569-019-0331-x</pub-id>
</citation>
</ref>
<ref id="B16">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Keeley</surname>
<given-names>T. P.</given-names>
</name>
<name>
<surname>Mann</surname>
<given-names>G. E.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Defining physiological normoxia for improved translation of cell physiology to animal models and humans</article-title>. <source>Physiol. Rev.</source> <volume>99</volume>, <fpage>161</fpage>&#x2013;<lpage>234</lpage>. <pub-id pub-id-type="doi">10.1152/physrev.00041.2017</pub-id>
</citation>
</ref>
<ref id="B17">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Keeley</surname>
<given-names>T. P.</given-names>
</name>
<name>
<surname>Siow</surname>
<given-names>R. C. M.</given-names>
</name>
<name>
<surname>Jacob</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Mann</surname>
<given-names>G. E.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Reduced SERCA activity underlies dysregulation of Ca(2&#x2b;) homeostasis under atmospheric O(2) levels</article-title>. <source>Faseb J.</source> <volume>32</volume>, <fpage>2531</fpage>&#x2013;<lpage>2538</lpage>. <pub-id pub-id-type="doi">10.1096/fj.201700685rrr</pub-id>
</citation>
</ref>
<ref id="B18">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kellner</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Liebsch</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Klimant</surname>
<given-names>I.</given-names>
</name>
<name>
<surname>Wolfbeis</surname>
<given-names>O. S.</given-names>
</name>
<name>
<surname>Blunk</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Schulz</surname>
<given-names>M. B.</given-names>
</name>
<etal/>
</person-group> (<year>2002</year>). <article-title>Determination of oxygen gradients in engineered tissue using a fluorescent sensor</article-title>. <source>Biotechnol. Bioeng.</source> <volume>80</volume>, <fpage>73</fpage>&#x2013;<lpage>83</lpage>. <pub-id pub-id-type="doi">10.1002/bit.10352</pub-id>
</citation>
</ref>
<ref id="B19">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kiyose</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Hanaoka</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Oushiki</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Nakamura</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Kajimura</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Suematsu</surname>
<given-names>M.</given-names>
</name>
<etal/>
</person-group> (<year>2010</year>). <article-title>Hypoxia-sensitive fluorescent probes for <italic>in vivo</italic> real-time fluorescence imaging of acute ischemia</article-title>. <source>J. Am. Chem. Soc.</source> <volume>132</volume>, <fpage>15846</fpage>&#x2013;<lpage>15848</lpage>. <pub-id pub-id-type="doi">10.1021/ja105937q</pub-id>
</citation>
</ref>
<ref id="B20">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Klimant</surname>
<given-names>I.</given-names>
</name>
<name>
<surname>Meyer</surname>
<given-names>V.</given-names>
</name>
<name>
<surname>K&#xfc;hl</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>1995</year>). <article-title>Fiber-optic oxygen microsensors, a new tool in aquatic biology</article-title>. <source>Limnol. Oceanogr.</source> <volume>40</volume>, <fpage>1159</fpage>&#x2013;<lpage>1165</lpage>. <pub-id pub-id-type="doi">10.4319/lo.1995.40.6.1159</pub-id>
</citation>
</ref>
<ref id="B21">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Klimas</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Ortiz</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Boggess</surname>
<given-names>S. C.</given-names>
</name>
<name>
<surname>Miller</surname>
<given-names>E. W.</given-names>
</name>
<name>
<surname>Entcheva</surname>
<given-names>E.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Multimodal on-axis platform for all-optical electrophysiology with near-infrared probes in human stem-cell-derived cardiomyocytes</article-title>. <source>Prog. Biophys. Mol. Biol.</source> <volume>154</volume>, <fpage>62</fpage>&#x2013;<lpage>70</lpage>. <pub-id pub-id-type="doi">10.1016/j.pbiomolbio.2019.02.004</pub-id>
</citation>
</ref>
<ref id="B22">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kostov</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Comte</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Scheper</surname>
<given-names>T.</given-names>
</name>
</person-group> (<year>1998</year>). <article-title>Solid state luminescence phase-shift oxygen sensor for biotechnology</article-title>. <source>Chem. Biochem. Eng. Q.</source> <volume>12</volume>, <fpage>201</fpage>&#x2013;<lpage>205</lpage>.</citation>
</ref>
<ref id="B23">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kostov</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Harms</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Pilato</surname>
<given-names>R. S.</given-names>
</name>
<name>
<surname>Rao</surname>
<given-names>G.</given-names>
</name>
</person-group> (<year>2000a</year>). <article-title>Ratiometric oxygen sensing: Detection of dual-emission ratio through a single emission filter</article-title>. <source>Analyst</source> <volume>125</volume>, <fpage>1175</fpage>&#x2013;<lpage>1178</lpage>. <pub-id pub-id-type="doi">10.1039/b002348p</pub-id>
</citation>
</ref>
<ref id="B24">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kostov</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Rao</surname>
<given-names>G.</given-names>
</name>
</person-group> (<year>1999</year>). <article-title>Low-cost device for ratiometric fluorescence measurements</article-title>. <source>Rev. Sci. Instr.</source> <volume>70</volume>, <fpage>4466</fpage>&#x2013;<lpage>4470</lpage>. <pub-id pub-id-type="doi">10.1063/1.1150098</pub-id>
</citation>
</ref>
<ref id="B25">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kostov</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Van Houten</surname>
<given-names>K. A.</given-names>
</name>
<name>
<surname>Harms</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Pilato</surname>
<given-names>R. S.</given-names>
</name>
<name>
<surname>Rao</surname>
<given-names>G.</given-names>
</name>
</person-group> (<year>2000b</year>). <article-title>Unique oxygen analyzer combining a dual emission probe and a low-cost solid-state ratiometric fluorometer</article-title>. <source>Appl. Spectrosc.</source> <volume>54</volume>, <fpage>864</fpage>&#x2013;<lpage>868</lpage>. <pub-id pub-id-type="doi">10.1366/0003702001950238</pub-id>
</citation>
</ref>
<ref id="B26">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kuzmiak-Glancy</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Covian</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Femnou</surname>
<given-names>A. N.</given-names>
</name>
<name>
<surname>Glancy</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Jaimes</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Wengrowski</surname>
<given-names>A. M.</given-names>
</name>
<etal/>
</person-group> (<year>2018</year>). <article-title>Cardiac performance is limited by oxygen delivery to the mitochondria in the crystalloid-perfused working heart</article-title>. <source>Am. J. Physiol. Heart Circ. Physiol.</source> <volume>314</volume>, <fpage>H704</fpage>&#x2013;<lpage>H715</lpage>. <pub-id pub-id-type="doi">10.1152/ajpheart.00321.2017</pub-id>
</citation>
</ref>
<ref id="B27">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Li</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Han</surname>
<given-names>J. L.</given-names>
</name>
<name>
<surname>Entcheva</surname>
<given-names>E.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Syncytium cell growth increases Kir2.1 contribution in human iPSC-cardiomyocytes</article-title>. <source>Am. J. Physiol. Heart Circ. Physiol.</source> <volume>319</volume>, <fpage>H1112</fpage>&#x2013;<lpage>h1122</lpage>. <pub-id pub-id-type="doi">10.1152/ajpheart.00148.2020</pub-id>
</citation>
</ref>
<ref id="B28">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lian</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Bao</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Zilberter</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Westman</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Fisahn</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Hsiao</surname>
<given-names>C.</given-names>
</name>
<etal/>
</person-group> (<year>2015</year>). <article-title>Chemically defined, albumin-free human cardiomyocyte generation</article-title>. <source>Nat. Methods</source> <volume>12</volume>, <fpage>595</fpage>&#x2013;<lpage>596</lpage>. <pub-id pub-id-type="doi">10.1038/nmeth.3448</pub-id>
</citation>
</ref>
<ref id="B29">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Liebsch</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Klimant</surname>
<given-names>I.</given-names>
</name>
<name>
<surname>Frank</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Holst</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Wolfbeis</surname>
<given-names>O. S.</given-names>
</name>
</person-group> (<year>2000</year>). <article-title>Luminescence lifetime imaging of oxygen, pH, and carbon dioxide distribution using optical sensors</article-title>. <source>Appl. Spectrosc.</source> <volume>54</volume>, <fpage>548</fpage>&#x2013;<lpage>559</lpage>. <pub-id pub-id-type="doi">10.1366/0003702001949726</pub-id>
</citation>
</ref>
<ref id="B30">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Liu</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Han</surname>
<given-names>J. L.</given-names>
</name>
<name>
<surname>Tomek</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Bub</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Entcheva</surname>
<given-names>E.</given-names>
</name>
</person-group> (<year>2023</year>). <article-title>Simultaneous widefield voltage and dye-free optical mapping quantifies electromechanical waves in human induced pluripotent stem cell-derived cardiomyocytes</article-title>. <source>ACS Photonics</source> <volume>10</volume>, <fpage>1070</fpage>&#x2013;<lpage>1083</lpage>. <pub-id pub-id-type="doi">10.1021/acsphotonics.2c01644</pub-id>
</citation>
</ref>
<ref id="B31">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lyra-Leite</surname>
<given-names>D. M.</given-names>
</name>
<name>
<surname>Guti&#xe9;rrez-Guti&#xe9;rrez</surname>
<given-names>&#xd3;.</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Zhou</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Cyganek</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Burridge</surname>
<given-names>P. W.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>A review of protocols for human iPSC culture, cardiac differentiation, subtype-specification, maturation, and direct reprogramming</article-title>. <source>Star. Protoc.</source> <volume>3</volume>, <fpage>101560</fpage>. <pub-id pub-id-type="doi">10.1016/j.xpro.2022.101560</pub-id>
</citation>
</ref>
<ref id="B32">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Peniche Silva</surname>
<given-names>C. J.</given-names>
</name>
<name>
<surname>Liebsch</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Meier</surname>
<given-names>R. J.</given-names>
</name>
<name>
<surname>Gutbrod</surname>
<given-names>M. S.</given-names>
</name>
<name>
<surname>Balmayor</surname>
<given-names>E. R.</given-names>
</name>
<name>
<surname>van Griensven</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>A new non-invasive technique for measuring 3D-oxygen gradients in wells during mammalian cell culture</article-title>. <source>Front. Bioeng. Biotechnol.</source> <volume>8</volume>, <fpage>595</fpage>. <pub-id pub-id-type="doi">10.3389/fbioe.2020.00595</pub-id>
</citation>
</ref>
<ref id="B33">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Pressler</surname>
<given-names>M. P.</given-names>
</name>
<name>
<surname>Horvath</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Entcheva</surname>
<given-names>E.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Sex-dependent transcription of cardiac electrophysiology and links to acetylation modifiers based on the GTEx database</article-title>. <source>Front. Cardiovasc Med.</source> <volume>9</volume>, <fpage>941890</fpage>. <pub-id pub-id-type="doi">10.3389/fcvm.2022.941890</pub-id>
</citation>
</ref>
<ref id="B34">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Rana</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Anson</surname>
<given-names>B.</given-names>
</name>
<name>
<surname>Engle</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Will</surname>
<given-names>Y.</given-names>
</name>
</person-group> (<year>2012</year>). <article-title>Characterization of human-induced pluripotent stem cell-derived cardiomyocytes: Bioenergetics and utilization in safety screening</article-title>. <source>Toxicol. Sci. official J. Soc. Toxicol.</source> <volume>130</volume>, <fpage>117</fpage>&#x2013;<lpage>131</lpage>. <pub-id pub-id-type="doi">10.1093/toxsci/kfs233</pub-id>
</citation>
</ref>
<ref id="B35">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Rogers</surname>
<given-names>G. W.</given-names>
</name>
<name>
<surname>Brand</surname>
<given-names>M. D.</given-names>
</name>
<name>
<surname>Petrosyan</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Ashok</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Elorza</surname>
<given-names>A. A.</given-names>
</name>
<name>
<surname>Ferrick</surname>
<given-names>D. A.</given-names>
</name>
<etal/>
</person-group> (<year>2011</year>). <article-title>High throughput microplate respiratory measurements using minimal quantities of isolated mitochondria</article-title>. <source>PLoS One</source> <volume>6</volume>, <fpage>e21746</fpage>. <pub-id pub-id-type="doi">10.1371/journal.pone.0021746</pub-id>
</citation>
</ref>
<ref id="B36">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sandhu</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Kydd</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Jaworski</surname>
<given-names>J.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>Luminescent probe based techniques for hypoxia imaging</article-title>. <source>J. Nanomed Res.</source> <volume>6</volume>, <fpage>00160</fpage>. <pub-id pub-id-type="doi">10.15406/jnmr.2017.06.00160</pub-id>
</citation>
</ref>
<ref id="B37">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sekine</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Kagawa</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Maeyama</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Ota</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Haraguchi</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Matsuura</surname>
<given-names>K.</given-names>
</name>
<etal/>
</person-group> (<year>2014</year>). <article-title>Oxygen consumption of human heart cells in monolayer culture</article-title>. <source>Biochem. Biophys. Res. Commun.</source> <volume>452</volume>, <fpage>834</fpage>&#x2013;<lpage>839</lpage>. <pub-id pub-id-type="doi">10.1016/j.bbrc.2014.09.018</pub-id>
</citation>
</ref>
<ref id="B38">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Severinghaus</surname>
<given-names>J. W.</given-names>
</name>
</person-group> (<year>2004</year>). <article-title>First electrodes for blood Po2 and Pco2 determination</article-title>. <source>J. Appl. Physiology</source> <volume>97</volume>, <fpage>1599</fpage>&#x2013;<lpage>1600</lpage>. <pub-id pub-id-type="doi">10.1152/classicessays.00021.2004</pub-id>
</citation>
</ref>
<ref id="B39">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Shi</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Inoue</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Wu</surname>
<given-names>J. C.</given-names>
</name>
<name>
<surname>Yamanaka</surname>
<given-names>S.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>Induced pluripotent stem cell technology: A decade of progress</article-title>. <source>Nat. Rev. Drug Discov.</source> <volume>16</volume>, <fpage>115</fpage>&#x2013;<lpage>130</lpage>. <pub-id pub-id-type="doi">10.1038/nrd.2016.245</pub-id>
</citation>
</ref>
<ref id="B40">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Strauss</surname>
<given-names>D. G.</given-names>
</name>
<name>
<surname>Blinova</surname>
<given-names>K.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>Clinical trials in a dish</article-title>. <source>Trends Pharmacol. Sci.</source> <volume>38</volume>, <fpage>4</fpage>&#x2013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.1016/j.tips.2016.10.009</pub-id>
</citation>
</ref>
<ref id="B41">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Tschiersch</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Liebsch</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Borisjuk</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Stangelmayer</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Rolletschek</surname>
<given-names>H.</given-names>
</name>
</person-group> (<year>2012</year>). <article-title>An imaging method for oxygen distribution, respiration and photosynthesis at a microscopic level of resolution</article-title>. <source>New Phytol.</source> <volume>196</volume>, <fpage>926</fpage>&#x2013;<lpage>936</lpage>. <pub-id pub-id-type="doi">10.1111/j.1469-8137.2012.04295.x</pub-id>
</citation>
</ref>
<ref id="B42">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wang</surname>
<given-names>X. D.</given-names>
</name>
<name>
<surname>Meier</surname>
<given-names>R. J.</given-names>
</name>
<name>
<surname>Link</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Wolfbeis</surname>
<given-names>O. S.</given-names>
</name>
</person-group> (<year>2010</year>). <article-title>Photographing oxygen distribution</article-title>. <source>Angew. Chem. Int. Ed. Engl.</source> <volume>49</volume>, <fpage>5027</fpage>&#x2013;<lpage>5029</lpage>. <pub-id pub-id-type="doi">10.1002/ange.201001305</pub-id>
</citation>
</ref>
<ref id="B43">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wang</surname>
<given-names>X. D.</given-names>
</name>
<name>
<surname>Wolfbeis</surname>
<given-names>O. S.</given-names>
</name>
</person-group> (<year>2014</year>). <article-title>Optical methods for sensing and imaging oxygen: Materials, spectroscopies and applications</article-title>. <source>Chem. Soc. Rev.</source> <volume>43</volume>, <fpage>3666</fpage>&#x2013;<lpage>3761</lpage>. <pub-id pub-id-type="doi">10.1039/c4cs00039k</pub-id>
</citation>
</ref>
<ref id="B44">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wei</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Entcheva</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>Z.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Microfluidics-enabled 96-well perfusion system for high-throughput tissue engineering and long-term all-optical electrophysiology</article-title>. <source>Lab. Chip</source> <volume>20</volume>, <fpage>4031</fpage>&#x2013;<lpage>4042</lpage>. <pub-id pub-id-type="doi">10.1039/d0lc00615g</pub-id>
</citation>
</ref>
<ref id="B45">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wolff</surname>
<given-names>P.</given-names>
</name>
<name>
<surname>Heimann</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Liebsch</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Meier</surname>
<given-names>R. J.</given-names>
</name>
<name>
<surname>Gutbrod</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>van Griensven</surname>
<given-names>M.</given-names>
</name>
<etal/>
</person-group> (<year>2019</year>). <article-title>Oxygen-distribution within 3-D collagen I hydrogels for bone tissue engineering</article-title>. <source>Mater. Sci. Eng. C, Mater. Biol. Appl.</source> <volume>95</volume>, <fpage>422</fpage>&#x2013;<lpage>427</lpage>. <pub-id pub-id-type="doi">10.1016/j.msec.2018.02.015</pub-id>
</citation>
</ref>
<ref id="B46">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Wu</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Wu</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Yi</surname>
<given-names>Z.</given-names>
</name>
<name>
<surname>Zeng</surname>
<given-names>F.</given-names>
</name>
<name>
<surname>Wu</surname>
<given-names>W.</given-names>
</name>
<name>
<surname>Qiao</surname>
<given-names>Y.</given-names>
</name>
<etal/>
</person-group> (<year>2018</year>). <article-title>Hydrogel-based fluorescent dual pH and oxygen sensors loaded in 96-well plates for high-throughput cell metabolism studies</article-title>. <source>Sensors</source> <volume>18</volume>, <fpage>564</fpage>. <pub-id pub-id-type="doi">10.3390/s18020564</pub-id>
</citation>
</ref>
<ref id="B47">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yang</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Ribeiro</surname>
<given-names>A. J. S.</given-names>
</name>
<name>
<surname>Pang</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Strauss</surname>
<given-names>D. G.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Use of human iPSC-CMs in nonclinical regulatory studies for cardiac safety assessment</article-title>. <source>Toxicol. Sci. official J. Soc. Toxicol.</source> <volume>190</volume>, <fpage>117</fpage>&#x2013;<lpage>126</lpage>. <pub-id pub-id-type="doi">10.1093/toxsci/kfac095</pub-id>
</citation>
</ref>
<ref id="B48">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yao</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Sattler</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Rabbani</surname>
<given-names>Z. N.</given-names>
</name>
<name>
<surname>Pulliam</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Walker</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Gamcsik</surname>
<given-names>M. P.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Mixing and delivery of multiple controlled oxygen environments to a single multiwell culture plate</article-title>. <source>Am. J. Physiology-Cell Physiology</source> <volume>315</volume>, <fpage>C766</fpage>&#x2013;<lpage>C775</lpage>. <pub-id pub-id-type="doi">10.1152/ajpcell.00276.2018</pub-id>
</citation>
</ref>
<ref id="B49">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yao</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Walker</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Gamcsik</surname>
<given-names>M. P.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>A multiwell plate-based system for toxicity screening under multiple static or cycling oxygen environments</article-title>. <source>Sci. Rep.</source> <volume>11</volume>, <fpage>4020</fpage>. <pub-id pub-id-type="doi">10.1038/s41598-021-83579-1</pub-id>
</citation>
</ref>
<ref id="B50">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yoshihara</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Hirakawa</surname>
<given-names>Y.</given-names>
</name>
<name>
<surname>Hosaka</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Nangaku</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Tobita</surname>
<given-names>S.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>Oxygen imaging of living cells and tissues using luminescent molecular probes</article-title>. <source>J. Photochem. Photobiol. C Photochem. Rev.</source> <volume>30</volume>, <fpage>71</fpage>&#x2013;<lpage>95</lpage>. <pub-id pub-id-type="doi">10.1016/j.jphotochemrev.2017.01.001</pub-id>
</citation>
</ref>
</ref-list>
</back>
</article>