<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article article-type="research-article" dtd-version="2.3" xml:lang="EN" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">Front. Anal. Sci.</journal-id>
<journal-title>Frontiers in Analytical Science</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Front. Anal. Sci.</abbrev-journal-title>
<issn pub-type="epub">2673-9283</issn>
<publisher>
<publisher-name>Frontiers Media S.A.</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">1527110</article-id>
<article-id pub-id-type="doi">10.3389/frans.2025.1527110</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Analytical Science</subject>
<subj-group>
<subject>Original Research</subject>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Multi-energy calibration in plasma emission spectrometry: elemental analysis of animal feeds</article-title>
<alt-title alt-title-type="left-running-head">Cora Jofre et al.</alt-title>
<alt-title alt-title-type="right-running-head">
<ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3389/frans.2025.1527110">10.3389/frans.2025.1527110</ext-link>
</alt-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Cora Jofre</surname>
<given-names>Florencia</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/2940735/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
<role content-type="https://credit.niso.org/contributor-roles/validation/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
<role content-type="https://credit.niso.org/contributor-roles/data-curation/"/>
<role content-type="https://credit.niso.org/contributor-roles/formal-analysis/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Barros</surname>
<given-names>Ariane I.</given-names>
</name>
<xref ref-type="aff" rid="aff3">
<sup>3</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/585125/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
<role content-type="https://credit.niso.org/contributor-roles/methodology/"/>
<role content-type="https://credit.niso.org/contributor-roles/supervision/"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>N&#xf3;brega</surname>
<given-names>Joaquim A.</given-names>
</name>
<xref ref-type="aff" rid="aff4">
<sup>4</sup>
</xref>
<uri xlink:href="https://loop.frontiersin.org/people/627255/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/supervision/"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
<role content-type="https://credit.niso.org/contributor-roles/funding-acquisition/"/>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name>
<surname>Savio</surname>
<given-names>Marianela</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
<xref ref-type="corresp" rid="c001">&#x2a;</xref>
<uri xlink:href="https://loop.frontiersin.org/people/1907678/overview"/>
<role content-type="https://credit.niso.org/contributor-roles/supervision/"/>
<role content-type="https://credit.niso.org/contributor-roles/Writing - review &#x26; editing/"/>
<role content-type="https://credit.niso.org/contributor-roles/conceptualization/"/>
<role content-type="https://credit.niso.org/contributor-roles/investigation/"/>
<role content-type="https://credit.niso.org/contributor-roles/validation/"/>
<role content-type="https://credit.niso.org/contributor-roles/writing-original-draft/"/>
</contrib>
</contrib-group>
<aff id="aff1">
<sup>1</sup>
<institution>Facultad Ciencias Exactas y Naturales</institution>, <institution>Universidad Nacional de La Pampa (UNLPam)</institution>, <addr-line>Santa Rosa</addr-line>, <addr-line>La Pampa</addr-line>, <country>Argentina</country>
</aff>
<aff id="aff2">
<sup>2</sup>
<institution>Instituto de Ciencias de la Tierra y Ambientales de La Pampa (Consejo Nacional de Investigaciones Cient&#xed;ficas y T&#xe9;cnicas - Universidad Nacional de La Pampa), INCITAP</institution>, <addr-line>Mendoza</addr-line>, <country>Argentina</country>
</aff>
<aff id="aff3">
<sup>3</sup>
<institution>Study Group on Soil Residues and Organic Matter</institution>, <institution>Department of Rural and Soil Engineering</institution>, <institution>Faculty of Agronomy and Zootechnics</institution>, <institution>Federal University of Mato Grosso</institution>, <addr-line>Mato Grosso</addr-line>, <country>Brazil</country>
</aff>
<aff id="aff4">
<sup>4</sup>
<institution>Group for Applied Instrumental Analysis</institution>, <institution>Department of Chemistry</institution>, <institution>Federal University of S&#xe3;o Carlos</institution>, <addr-line>S&#xe3;o Carlos</addr-line>, <country>Brazil</country>
</aff>
<author-notes>
<fn fn-type="edited-by">
<p>
<bold>Edited by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/774762/overview">Elefteria Psillakis</ext-link>, Technical University of Crete, Greece</p>
</fn>
<fn fn-type="edited-by">
<p>
<bold>Reviewed by:</bold> <ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/979176/overview">Alessandra Cincinelli</ext-link>, University of Florence, Italy</p>
<p>
<ext-link ext-link-type="uri" xlink:href="https://loop.frontiersin.org/people/1066068/overview">Ashok K. Shakya</ext-link>, Al-Ahliyya Amman University, Jordan</p>
</fn>
<corresp id="c001">&#x2a;Correspondence: Marianela Savio, <email>msavio@exactas.unlpam.edu.ar</email>
</corresp>
</author-notes>
<pub-date pub-type="epub">
<day>27</day>
<month>02</month>
<year>2025</year>
</pub-date>
<pub-date pub-type="collection">
<year>2025</year>
</pub-date>
<volume>5</volume>
<elocation-id>1527110</elocation-id>
<history>
<date date-type="received">
<day>12</day>
<month>11</month>
<year>2024</year>
</date>
<date date-type="accepted">
<day>03</day>
<month>02</month>
<year>2025</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#xa9; 2025 Cora Jofre, Barros, N&#xf3;brega and Savio.</copyright-statement>
<copyright-year>2025</copyright-year>
<copyright-holder>Cora Jofre, Barros, N&#xf3;brega and Savio</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.</p>
</license>
</permissions>
<abstract>
<p>This study evaluates the effectiveness of Multi-Energy Calibration (MEC) for multielemental analysis in animal feeds using plasma-based optical emission spectrometry (ICP-OES and MIP-OES). The aim was to improve accuracy in detecting essential minerals by overcoming matrix interferences that affect instrumental techniques. Swine feed samples from different growth stages were analyzed, focusing on essential minerals for animal health and productivity, such as Ca, Co, Cu, Fe, K, Mg, Mn, Na, P, and Zn. The MEC strategy utilizes multiple wavelengths per element, reducing calibration complexity and enhancing accuracy by using only two calibration solutions per sample. Results demonstrate that MEC improves recoveries (80%&#x2013;105%) when compared to traditional external calibration (EC). The limits of quantification (LOQs) ranged from 0.09&#xa0;mg&#xa0;kg&#x207b;<sup>1</sup> for Mn to 31&#xa0;mg&#xa0;kg&#x207b;<sup>1</sup> for Ca and Na using MEC-ICP-OES, and from 0.08&#xa0;mg&#xa0;kg&#x207b;<sup>1</sup> for Mn to 354&#xa0;mg&#xa0;kg&#x207b;<sup>1</sup> for P using MEC-MIP-OES. For EC, they ranged from 0.4&#xa0;mg&#xa0;kg&#x207b;<sup>1</sup> for Co to 195&#xa0;mg&#xa0;kg&#x207b;<sup>1</sup> for K with ICP-OES and from 2.0&#xa0;mg&#xa0;kg&#x207b;<sup>1</sup> for Mg to 607&#xa0;mg&#xa0;kg&#x207b;<sup>1</sup> for Fe with MIP-OES. MEC provides high precision and matrix-matching capabilities. This makes MEC a reliable method for complex feed matrices, supporting more accurate feed formulations to ensure optimal livestock nutrition.</p>
</abstract>
<kwd-group>
<kwd>multi-energy calibration</kwd>
<kwd>animal feed</kwd>
<kwd>multielemental determination</kwd>
<kwd>ICP-OES</kwd>
<kwd>MIP-OES</kwd>
</kwd-group>
<custom-meta-wrap>
<custom-meta>
<meta-name>section-at-acceptance</meta-name>
<meta-value>Environmental Analysis</meta-value>
</custom-meta>
</custom-meta-wrap>
</article-meta>
</front>
<body>
<sec id="s1">
<title>1 Introduction</title>
<p>The rapid growth of the global population, projected to reach nearly 10 billion by 2050, is driving a significant increase in food demand, emphasizing the need for sustainable agricultural practices (<xref ref-type="bibr" rid="B16">Beily et al., 2011</xref>). In alignment with the Sustainable Development Goals (SDGs), which focus on eradicating hunger, achieving food security, improving nutrition, and promoting sustainable agriculture, many countries are adopting tailored strategies to boost food production (<xref ref-type="bibr" rid="B34">SDGs, 2024</xref>). One major area of focus is livestock production, where confined animal systems have become prevalent, increasing the demand for nutritionally balanced feed supplements (<xref ref-type="bibr" rid="B26">McDowell, 1992</xref>). These supplements must provide adequate concentrations of essential nutrients such as proteins, vitamins, and minerals to ensure animal health and productivity (<xref ref-type="bibr" rid="B37">Sol&#xe0;-Oriol and Gasa, 2017</xref>; <xref ref-type="bibr" rid="B35">Shurson et al., 2011</xref>; <xref ref-type="bibr" rid="B38">Spears and Weiss, 2008</xref>). The mineral content of feed is critical, as both deficiencies and excesses can lead to diseases, affecting not only animal wellbeing but also the quality of animal-derived food products consumed by humans (<xref ref-type="bibr" rid="B30">Patience, 1996</xref>; <xref ref-type="bibr" rid="B28">Novo et al., 2018</xref>).</p>
<p>Swine production offers advantages such as high efficiency in converting plant protein into animal protein, adaptability to thermal variations, and shorter production cycles compared to other livestock (<xref ref-type="bibr" rid="B38">Spears and Weiss, 2008</xref>). Efficient feed management, accounting for about 70% of production costs, is essential for profitability, particularly as pigs require specific nutrients at different life stages, from reproduction to growth. Therefore, the accurate measurement of essential minerals like calcium (Ca), chlorine (Cl), cobalt (Co), copper (Cu), iodine (I), iron (Fe), magnesium (Mg), manganese (Mn), phosphorus (P), potassium (K), selenium (Se), sodium (Na), sulfur (S), zinc (Zn), among others, in animal feed is crucial for ensuring optimal growth and productivity (<xref ref-type="bibr" rid="B11">National Research Council, 2012</xref>).</p>
<p>The complexity of agro-food matrices, which include pastures, grains, and rations, implies challenges for analytical techniques used in trace element determination. Sample preparation is a critical step, as it can introduce errors, with residual organic carbon and suspended solids potentially causing spectral and non-spectral interferences (<xref ref-type="bibr" rid="B3">Analytical Methods Committee, 2013</xref>). In recent years, different sample treatments employing microwave, infrared and/or ultrasound radiations have been proposed to improve the analyte extraction (<xref ref-type="bibr" rid="B25">Matusiewicz, 2017</xref>; <xref ref-type="bibr" rid="B27">N&#xf3;brega et al., 2012</xref>; <xref ref-type="bibr" rid="B22">Jofre and Savio, 2024</xref>). Additionally, calibration is a crucial aspect of analytical procedures, as it ensures the accurate translation of signal intensities into analyte concentrations. Traditional methods like external calibration (EC) are widely used for simple matrices, but for complex matrices, alternatives like internal standardization (IS) and standard additions (SA) are often necessary to correct for interferences (<xref ref-type="bibr" rid="B8">Carter et al., 2018</xref>; <xref ref-type="bibr" rid="B6">Barros, Pinheiro, and N&#xf3;brega, 2019</xref>; <xref ref-type="bibr" rid="B14">Donati and Amais, 2019</xref>).</p>
<p>To address conventional methods limitations, a novel calibration technique known as Multi-Energy Calibration (MEC) has been developed (<xref ref-type="bibr" rid="B40">Virgilio et al., 2017</xref>). When applying MEC to plasma emission spectrometry, multiple emission lines (wavelengths) for each element are measured simultaneously for calibration, instead of relying on a single emission line. Since inductively coupled plasma optical emission spectrometry (ICP-OES) and microwave induced plasma optical emission spectrometry (MIP-OES) plasmas can reach high temperatures (<italic>ca</italic>. 10,000&#xa0;K and <italic>ca</italic>. 5,000K, respectively), they effectively atomize, excite, and ionize many elements, generating multiple characteristic atomic and ionic emission lines. MEC takes advantage of this fact, offering several significant advantages that make it a powerful calibration strategy in plasma emission spectrometry. By utilizing multiple wavelengths, it mitigates interferences through the identification and elimination of affected wavelengths. A fundamental advantage of the MEC strategy is its ability to facilitate the visual identification of emission lines impacted by interferences, which appear as outliers on the calibration plot (<xref ref-type="bibr" rid="B8">Carter et al., 2018</xref>). This method is highly efficient, requiring only two calibration solutions per sample, thereby streamlining the analytical process and reducing both time and resource demands. Furthermore, its compatibility with existing instrumentation ensures that no modifications are necessary, making MEC a straightforward and adaptable technique for diverse analytical applications (<xref ref-type="bibr" rid="B41">Virgilio et al., 2020</xref>).</p>
<p>As shown in <xref ref-type="fig" rid="F1">Figure 1</xref>, laser-induced breakdown spectroscopy (LIBS) demonstrates the highest number of publications, particularly in 2020, while MIP-OES and ICP-OES show a more consistent distribution across the years. (<xref ref-type="bibr" rid="B32">Santos et al., 2024</xref>; <xref ref-type="bibr" rid="B7">Carneiro and Dias, 2021</xref>; <xref ref-type="bibr" rid="B41">Virgilio et al., 2020</xref>; <xref ref-type="bibr" rid="B31">Pereira et al., 2020</xref>; <xref ref-type="bibr" rid="B13">Cruz et al., 2024</xref>; <xref ref-type="bibr" rid="B23">Li et al., 2020</xref>; <xref ref-type="bibr" rid="B18">Garde et al., 2020</xref>; <xref ref-type="bibr" rid="B12">Cruz et al., 2020</xref>; <xref ref-type="bibr" rid="B19">Gon&#xe7;alves et al., 2019</xref>; <xref ref-type="bibr" rid="B20">Higuera, Silva, and Nogueira, 2019</xref>; <xref ref-type="bibr" rid="B6">Barros, Pinheiro, and N&#xf3;brega, 2019</xref>; <xref ref-type="bibr" rid="B24">Machado et al., 2018</xref>; <xref ref-type="bibr" rid="B40">Virgilio et al., 2017</xref>; <xref ref-type="bibr" rid="B10">Castro, Babos, and Pereira-Filho, 2020</xref>; <xref ref-type="bibr" rid="B9">Carvalho et al., 2019</xref>; <xref ref-type="bibr" rid="B39">Vieira et al., 2019</xref>; <xref ref-type="bibr" rid="B2">Augusto et al., 2018</xref>; <xref ref-type="bibr" rid="B4">Babos et al., 2019</xref>; <xref ref-type="bibr" rid="B5">Babos et al., 2018</xref>; <xref ref-type="bibr" rid="B17">Fortunato et al., 2019</xref>; <xref ref-type="bibr" rid="B36">Soares, Donati, and Rocha, 2022</xref>). Notably, no MEC-related publications associated with these techniques are reported for the years 2022 and 2023 Comparative studies between ICP-OES and MIP-OES are limited to publications from 2017 to 2020, highlighting the need for additional research to provide comprehensive comparative data on these two techniques. As demonstrated in prior studies (<xref ref-type="bibr" rid="B32">Santos et al., 2024</xref>; <xref ref-type="bibr" rid="B31">Pereira et al., 2020</xref>; <xref ref-type="bibr" rid="B24">Machado et al., 2018</xref>; <xref ref-type="bibr" rid="B19">Gon&#xe7;alves et al., 2019</xref>; <xref ref-type="bibr" rid="B20">Higuera, Silva, and Nogueira, 2019</xref>; <xref ref-type="bibr" rid="B8">Carter et al., 2018</xref>), MEC has proven particularly effective for complex matrices such as food, beverages, and biological samples, among others. Its versatility and robust performance in identifying interferences and delivering accurate results position MEC as a significant advancement in plasma spectrometry calibration strategies.</p>
<fig id="F1" position="float">
<label>FIGURE 1</label>
<caption>
<p>Distribution of MEC publications with MIP-OES, ICP-OES, LIBS, and HR-CS AAS from 2017 to 2024.</p>
</caption>
<graphic xlink:href="frans-05-1527110-g001.tif"/>
</fig>
<p>This study aims to evaluate the potential of MEC as a matrix-matching calibration strategy for the determination of minerals such as Ca, Co, Cu, Fe, K, Mg, Mn, Na, P, and Zn in animal feed samples using ICP-OES and MIP-OES; ensuring reliable quantification of mineral content. Additionally, the study seeks to assess the nutritional value of the feed, as this information is critical for formulating balanced rations that directly impact pig growth and development.</p>
</sec>
<sec sec-type="materials|methods" id="s2">
<title>2 Materials and methods</title>
<sec id="s2-1">
<title>2.1 Sampling and sample preservation</title>
<p>Thirteen swine feed samples covering different physiological stages in pork life were obtained from a local farm in La Pampa, Argentina. The following different growth stages were considered: Growth stages I (3&#x2013;5&#xa0;kg), II (5&#x2013;10&#xa0;kg), III (10&#x2013;20&#xa0;kg), and IV (20&#x2013;50&#xa0;kg); Development phases I (20&#x2013;50&#xa0;kg), II (20&#x2013;50&#xa0;kg) and III (50&#x2013;80&#xa0;kg); Completion phase I (20&#x2013;50&#xa0;kg), II (50&#x2013;80&#xa0;kg) and III (50&#x2013;80&#xa0;kg); Bristle (80&#x2013;120&#xa0;kg); Bristle in gestation; and Bristle in lactation. All samples were gathered into polyethylene bags and stored in a dry and dark place. The samples were then pulverized using cryogenic milling equipment (model MA 775, Marconi, Piracicaba, SP, Brazil).</p>
</sec>
<sec id="s2-2">
<title>2.2 Sample preparation</title>
<p>Samples for ICP-OES determination were prepared according to the method proposed by <xref ref-type="bibr" rid="B33">Savio et al. (2019)</xref>, using an UltraWAVE&#x2122; microwave oven with a single reaction chamber design (SRC, Milestone, Sorisole, Italy) (<xref ref-type="bibr" rid="B27">N&#xf3;brega et al., 2012</xref>). For MIP-OES determination, samples were prepared following the method by Cora Jofre et al., using an infrared radiation digestion prototype (IRAD) (<xref ref-type="bibr" rid="B21">Jofre et al., 2020</xref>).</p>
</sec>
<sec id="s2-3">
<title>2.3 Instrumentation</title>
<p>Multielemental determinations were carried out by ICP-OES iCAP 7,000 from Thermo with dual view configuration (Thermo Fisher Scientific, Madison, WI, United States) and by MIP-OES, Agilent model MP AES 4210, operating in conventional conditions as shown in <xref ref-type="table" rid="T1">Table 1</xref>. Argon (99.999%, White Martins-Praxair) was used in all measurements.</p>
<table-wrap id="T1" position="float">
<label>TABLE 1</label>
<caption>
<p>Operating conditions for ICP-OES and MIP-OES determinations, including selected wavelength lines (discarded wavelengths are indicated in bold).</p>
</caption>
<table>
<thead valign="top">
<tr>
<th rowspan="2" align="center">Instrumental parameter</th>
<th colspan="2" align="center">Operating condition</th>
</tr>
<tr>
<th align="center">ICP-OES</th>
<th align="center">MIP-OES</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="center">Radio frequency applied power [kW]</td>
<td align="center">1.2</td>
<td align="center">1.0</td>
</tr>
<tr>
<td align="center">Plasma gas flow rate [L min<sup>-1</sup>]</td>
<td align="center">12</td>
<td align="center">20</td>
</tr>
<tr>
<td align="center">Auxiliary gas flow rate [L min<sup>-1</sup>]</td>
<td align="center">1</td>
<td align="center">1</td>
</tr>
<tr>
<td align="center">Nebulization gas flow rate [L min<sup>-1</sup>]</td>
<td align="center">0.70</td>
<td align="center">1.0</td>
</tr>
<tr>
<td align="center">Peristaltic pump speed [rpm]</td>
<td align="center">12</td>
<td align="center">15</td>
</tr>
<tr>
<td align="center">View</td>
<td align="center">axial</td>
<td align="center">radial</td>
</tr>
<tr>
<td align="center">Stabilization time [s]</td>
<td align="center">15</td>
<td align="center">15</td>
</tr>
<tr>
<td align="center">Integration time [s]</td>
<td align="center">3</td>
<td align="center">3</td>
</tr>
<tr>
<td align="center">Nebulizer</td>
<td align="center">concentric</td>
<td align="center">concentric</td>
</tr>
<tr>
<td align="center">Nebulization chamber</td>
<td align="center">cyclonic, double path</td>
<td align="center">Single Pass</td>
</tr>
<tr>
<td align="center">Replicates</td>
<td align="center">3</td>
<td align="center">3</td>
</tr>
<tr>
<td align="center">Analyte</td>
<td colspan="2" align="center">Wavelength [nm]&#x002A;</td>
</tr>
<tr>
<td align="center">Ca</td>
<td align="center">
<bold>183.801</bold>; <bold>184.006</bold>; 315.887; 317.933; 318.128; <bold>370.603</bold>; <bold>373.690</bold>; 393.366; 396.847; 422.673; 431.865</td>
<td align="center">393.366; <bold>396.847</bold>; <bold>422.673</bold>; <bold>430.253</bold>; <bold>445.478</bold>; <bold>616.217</bold>
</td>
</tr>
<tr>
<td align="center">Co</td>
<td align="center">195.742; 228.616; 230.786; <bold>231.160</bold>; <bold>235.342</bold>; 237.862; 238.892</td>
<td align="center">
<bold>240.725</bold>; <bold>340.512</bold>; 341.234; <bold>345.351</bold>; <bold>350.228</bold>; <bold>350.631</bold>
</td>
</tr>
<tr>
<td align="center">Cu</td>
<td align="center">
<bold>204.379</bold>; <bold>211.209</bold>; <bold>213.598</bold>; 214.897; <bold>217.894</bold>; <bold>219.958</bold>; <bold>221.810</bold>; <bold>224.700</bold>; <bold>324.754</bold>; <bold>327.396</bold>
</td>
<td align="center">
<bold>216.510</bold>; <bold>217.895</bold>; <bold>223.008</bold>; <bold>324.754</bold>; <bold>327.395</bold>; <bold>510.554</bold>
</td>
</tr>
<tr>
<td align="center">Fe</td>
<td align="center">
<bold>218.719</bold>; <bold>233.280</bold>; <bold>234.349</bold>; <bold>238.204</bold>; <bold>239.562</bold>; <bold>240.488</bold>; <bold>259.837</bold>; <bold>259.940</bold>; <bold>261.187</bold>; <bold>271.441</bold>; <bold>273.074</bold>; <bold>274.932</bold>; <bold>322.775</bold>; <bold>371.994</bold>
</td>
<td align="center">
<bold>259.940</bold>; <bold>358.119</bold>; 371.993; <bold>373.486</bold>; <bold>373.713</bold>; <bold>385.991</bold>
</td>
</tr>
<tr>
<td align="center">K</td>
<td align="center">
<bold>404.414</bold>; <bold>404.721</bold>; <bold>766.490</bold>; <bold>769.896</bold>
</td>
<td align="center">344.738; <bold>404.414</bold>; <bold>404.721</bold>; 693.877; <bold>766.491</bold>; <bold>769.897</bold>
</td>
</tr>
<tr>
<td align="center">Mg</td>
<td align="center">
<bold>202.582</bold>; 279.079; <bold>279.553</bold>; 279.806; <bold>280.270</bold>; <bold>285.213</bold>
</td>
<td align="center">279.553; <bold>280.271</bold>; 285.213; 383.230; <bold>383.829</bold>; <bold>517.268</bold>; <bold>518.360</bold>
</td>
</tr>
<tr>
<td align="center">Mn</td>
<td align="center">
<bold>191.510</bold>; <bold>257.610</bold>; <bold>259.373</bold>; 260.589; <bold>279.482</bold>; <bold>293.930</bold>; <bold>294.920</bold>; <bold>348.291</bold>; 403.076; <bold>403.307</bold>
</td>
<td align="center">257.610; <bold>259.372</bold>; 279.482; <bold>403.076</bold>; <bold>403.307</bold>; <bold>403.449</bold>
</td>
</tr>
<tr>
<td align="center">Na</td>
<td align="center">330.237; 330.298; 568.820; <bold>588.995</bold>; <bold>589.592</bold>; <bold>818.326</bold>
</td>
<td align="center">330.237; 330.298; <bold>568.263</bold>; <bold>568.820</bold>; 588.995; <bold>589.592</bold>
</td>
</tr>
<tr>
<td align="center">P</td>
<td align="center">
<bold>177.495</bold>; 178.284; <bold>178.766</bold>; <bold>185.891</bold>; <bold>185.942</bold>; <bold>213.618</bold>; 214.914</td>
<td align="center">213.618; <bold>214.915</bold>; <bold>253.560</bold>; <bold>255.326</bold>; 764.934</td>
</tr>
<tr>
<td align="center">Zn</td>
<td align="center">
<bold>202.548</bold>; <bold>206.200</bold>; <bold>213.856</bold>; <bold>328.233</bold>; <bold>330.259</bold>; <bold>334.502</bold>; <bold>472.216</bold>; 481.053</td>
<td align="center">202.548; <bold>206.200</bold>; <bold>213.857</bold>; 328.233; <bold>472.215</bold>; <bold>481.053</bold>
</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn>
<p>&#x2a; Emission lines employed for MEC calibration are listed in bold.</p>
</fn>
</table-wrap-foot>
</table-wrap>
</sec>
<sec id="s2-4">
<title>2.4 Reagents, standards, and solutions</title>
<sec id="s2-4-1">
<title>2.4.1 For MEC-ICP-OES determination</title>
<p>All reagents were of analytical grade, and all solutions were prepared using distilled-deionized water. A Millipore ultrapure water system (Millipore, Billerica, MA, United States) was utilized, which generates ultrapure deionized water (resistivity &#x2265;18.2&#xa0;M&#x3a9;&#xa0;cm). Concentrated HNO<sub>3</sub> (Merck, Darmstadt, Germany) was obtained using a sub-boiling device (Milestone). Concentrated hydrogen peroxide (30% w w<sup>&#x2212;1</sup>), Labsynth, Diadema, SP, Brazil) was also employed.</p>
<p>Standard solutions for MEC experiments were prepared by diluting of 1,000&#xa0;mg&#xa0;L<sup>-1</sup> solution of Ca, Co, Cu, Fe, K, Mg, Mn, Na, P, and Zn (Qhemis, S&#xe3;o Paulo, SP, Brasil; Titrisol-Merck, Darmstadt, Germany and Fluka, Buchs St. Gallen, Switzerland) in 0.14&#xa0;mol&#xa0;L<sup>-1</sup> HNO<sub>3</sub> solution. To assess the accuracy of the method, two reference materials (RM-Agro E3001a - Bovine Liver and MRC20 - Corn grain) and a proficiency test material &#x201c;animal mineral supplement&#x201d; (SM18-03) produced by EMBRAPA Pecu&#xe1;ria Sudeste (S&#xe3;o Carlos, SP, Brazil), were used.</p>
</sec>
<sec id="s2-4-2">
<title>2.4.2 For MEC-MIP-OES determination</title>
<p>All solutions were prepared using ultrapure water sourced from a Millipore<sup>&#xae;</sup> ultrapure water system (Mili-Q) as described previously. For sample digestion, nitric acid (HNO&#x2083;, 65% w w<sup>&#x2212;1</sup>, MERCK) was purified using a Berghoff<sup>&#xae;</sup> sub-boiling mineral acid distillation system to produce ultrapure, metal-free acid. Hydrogen peroxide (H&#x2082;O&#x2082;, 30% w w<sup>&#x2212;1</sup>, SIGMA-ALDRICH) was also utilized. Standard solutions were prepared by diluting individual 1,000&#xa0;mg&#xa0;L&#x207b;<sup>1</sup> stock solutions of Ca, Co, Cu, Fe, K, Mg, Mn, Na, P, and Zn (Sigma-Aldrich) for MEC analytical calibration. The proposed method was validated using the same reference materials as <xref ref-type="sec" rid="s10">Section 2.4.1</xref>.</p>
</sec>
</sec>
<sec id="s2-5">
<title>2.5 Preparation of solutions and calculations for MEC experiments</title>
<p>For preparing the calibration curves based on MEC strategy two solutions per sample and a mixing proportion of 1:1 (v v<sup>&#x2212;1</sup>) were adopted. The solution 1 (S1) was comprised of 50% (v v<sup>&#x2212;1</sup>) of the digested sample and 50% (v v<sup>&#x2212;1</sup>) of the standard solutions containing all analytes (Ca, Co, Cu, Fe, K, Mg, Mn, Na, P, and Zn) at varying concentrations (C_std) determined according to the expected analyte concentrations in the samples, as outlined by Carter et al. (<xref ref-type="bibr" rid="B8">Carter et al., 2018</xref>). Solution 2 (S2) consisted of 50% (v v<sup>&#x2212;1</sup>) of the digested sample and 50% (v v<sup>&#x2212;1</sup>) of an analytical blank solution (<xref ref-type="bibr" rid="B40">Virgilio et al., 2017</xref>; <xref ref-type="bibr" rid="B24">Machado et al., 2018</xref>). For the construction of MEC calibration curve, emission intensities at multiple wavelengths were recorded for each analyte, where the signals for S1 and S2 are plotted on the x and y-axes, respectively, resulting in a straight line. Once the MEC calibration curves were established, the concentration of each analyte was calculated using the following <xref ref-type="disp-formula" rid="e1">Equation 1</xref> proposed by <xref ref-type="bibr" rid="B40">Virgilio et al. (2017)</xref>:<disp-formula id="e1">
<mml:math id="m1">
<mml:mrow>
<mml:msub>
<mml:mrow>
<mml:mi>C</mml:mi>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:mi>A</mml:mi>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:mrow>
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mi>m</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x3d;</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:mi>s</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>o</mml:mi>
<mml:mi>p</mml:mi>
<mml:mi>e</mml:mi>
<mml:mo>&#xd7;</mml:mo>
<mml:msub>
<mml:mi>C</mml:mi>
<mml:mrow>
<mml:mi>S</mml:mi>
<mml:mi>t</mml:mi>
<mml:mi>d</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:mn>1</mml:mn>
<mml:mo>&#x2212;</mml:mo>
<mml:mi>s</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>o</mml:mi>
<mml:mi>p</mml:mi>
<mml:mi>e</mml:mi>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:mfrac>
</mml:mrow>
</mml:math>
<label>(1)</label>
</disp-formula>
</p>
<p>All experiments were carried out in triplicate, and the results were expressed as the mean of the measurements &#xb1; a confidence interval (&#x3b1; &#x3d; 0.05).</p>
</sec>
<sec id="s2-6">
<title>2.6 Statistical analysis</title>
<p>Microsoft Office Professional Plus Excel&#x2122; was utilized for all computations, including calibrations, performance metrics, recovery analyses, correlation assessments, comparisons, and associated statistical tests.</p>
<p>For MEC, the calculation of limits of detection (LODs) and quantification (LOQs) were made following error propagation approach, employing the concentration of the standard solution (C_std), the standard deviation of the slope (S_slope), and the slope itself, as described by <xref ref-type="bibr" rid="B41">Virgilio et al. (2020)</xref>. The following <xref ref-type="disp-formula" rid="e2">Equations 2</xref>, <xref ref-type="disp-formula" rid="e3">3</xref> were applied:<disp-formula id="e2">
<mml:math id="m2">
<mml:mrow>
<mml:mi>L</mml:mi>
<mml:mi>O</mml:mi>
<mml:mi>D</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>3</mml:mn>
<mml:mo>&#x2a;</mml:mo>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:mfrac>
<mml:mrow>
<mml:msub>
<mml:mi>C</mml:mi>
<mml:mrow>
<mml:mi>s</mml:mi>
<mml:mi>t</mml:mi>
<mml:mi>d</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x2a;</mml:mo>
<mml:msub>
<mml:mi>S</mml:mi>
<mml:mrow>
<mml:mi>s</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>o</mml:mi>
<mml:mi>p</mml:mi>
<mml:mi>e</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:msup>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:mn>1</mml:mn>
<mml:mo>&#x2212;</mml:mo>
<mml:mi>s</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>o</mml:mi>
<mml:mi>p</mml:mi>
<mml:mi>e</mml:mi>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:mn>2</mml:mn>
</mml:msup>
</mml:mfrac>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:mrow>
</mml:math>
<label>(2)</label>
</disp-formula>
<disp-formula id="e3">
<mml:math id="m3">
<mml:mrow>
<mml:mi>L</mml:mi>
<mml:mi>O</mml:mi>
<mml:mi>Q</mml:mi>
<mml:mo>&#x3d;</mml:mo>
<mml:mn>10</mml:mn>
<mml:mo>&#x2a;</mml:mo>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:mfrac>
<mml:mrow>
<mml:msub>
<mml:mi>C</mml:mi>
<mml:mrow>
<mml:mi>s</mml:mi>
<mml:mi>t</mml:mi>
<mml:mi>d</mml:mi>
</mml:mrow>
</mml:msub>
<mml:mo>&#x2a;</mml:mo>
<mml:msub>
<mml:mi>S</mml:mi>
<mml:mrow>
<mml:mi>s</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>o</mml:mi>
<mml:mi>p</mml:mi>
<mml:mi>e</mml:mi>
</mml:mrow>
</mml:msub>
</mml:mrow>
<mml:msup>
<mml:mrow>
<mml:mfenced open="(" close=")" separators="&#x7c;">
<mml:mrow>
<mml:mn>1</mml:mn>
<mml:mo>&#x2212;</mml:mo>
<mml:mi>s</mml:mi>
<mml:mi>l</mml:mi>
<mml:mi>o</mml:mi>
<mml:mi>p</mml:mi>
<mml:mi>e</mml:mi>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
<mml:mn>2</mml:mn>
</mml:msup>
</mml:mfrac>
</mml:mrow>
</mml:mfenced>
</mml:mrow>
</mml:mrow>
</mml:math>
<label>(3)</label>
</disp-formula>
</p>
</sec>
</sec>
<sec sec-type="results|discussion" id="s3">
<title>3 Results and discussion</title>
<sec id="s3-1">
<title>3.1 Multi-energy calibration strategy optimization</title>
<p>For the MEC method, optimal analytical lines were selected based on their sensitivity and interference absence. Each one, presented in <xref ref-type="table" rid="T1">Table 1</xref>, was used to obtain the calibration curve. Lines that deviate from the expected calibration model, indicated as outliers, were systematically excluded (emission lines employed for MEC calibration are listed in <xref ref-type="table" rid="T1">Table 1</xref> in bold).</p>
<p>In the present study, the MEC strategy was applied to multielement determinations using both ICP-OES and MIP-OES. Signals from S1 (x-axis) and S2 (y-axis) were used to construct the MEC plots (<xref ref-type="bibr" rid="B40">Virgilio et al., 2017</xref>; <xref ref-type="bibr" rid="B24">Machado et al., 2018</xref>). <xref ref-type="fig" rid="F2">Figures 2</xref>, <xref ref-type="fig" rid="F3">3</xref> display the calibration curves for the 10 analytes determined by ICP-OES and MIP-OES using MEC, based on the reference material RM-Agro E3001a (Bovine Liver). <xref ref-type="sec" rid="s10">Supplementary Tables S1, 2</xref> show the average intensities (n &#x3d; 3) and SD used for MEC-ICP-OES and MEC-MIP-OES curves construction. Similarly, <xref ref-type="sec" rid="s10">Supplementary Figures S1, 2</xref>, exhibit the calibration curves for the 10 analytes measured by ICP-OES and MIP-OES using MEC, based on Corn Grain reference material. The slopes and R<sup>2</sup> values are compared in <xref ref-type="table" rid="T2">Table 2</xref> and <xref ref-type="sec" rid="s10">Supplementary Table S3</xref> for 10 analytes across different sample types (e.g., maize, bovine liver, and animal mineral supplement), using both MEC-ICP-OES and MEC-MIP-OES. The calibration plots linearity was evaluated, and curves with emission lines that exhibited R<sup>2</sup> values above 0.9692 for ICP-OES and 0.9025 for MIP-OES were retained for further analysis (<xref ref-type="table" rid="T2">Table 2</xref> and <xref ref-type="sec" rid="s10">Supplementary Table S3</xref>), where a R<sup>2</sup> near 1.000 suggests that the selected wavelengths are likely free from interferences (<xref ref-type="bibr" rid="B31">Pereira et al., 2020</xref>). The slopes of the calibration curves were carefully assessed to ensure all angular coefficients fell within the acceptable range (0.1 &#x3c; slope &#x3c;0.9), as slopes outside this range could indicate potential inaccuracies (<xref ref-type="bibr" rid="B41">Virgilio et al., 2020</xref>).</p>
<fig id="F2" position="float">
<label>FIGURE 2</label>
<caption>
<p>Multi-energy calibration curves for <bold>(A)</bold> Ca, <bold>(B)</bold> Co, <bold>(C)</bold> Cu, <bold>(D)</bold> Fe, <bold>(E)</bold> K, <bold>(F)</bold> Mg, <bold>(G)</bold> Mn, <bold>(H)</bold> Na, <bold>(I)</bold> P and <bold>(J)</bold> Zn determined in RM-Agro E3001a - Bovine Liver by ICP-OES.</p>
</caption>
<graphic xlink:href="frans-05-1527110-g002.tif"/>
</fig>
<fig id="F3" position="float">
<label>FIGURE 3</label>
<caption>
<p>Multi-energy calibration curves for <bold>(A)</bold> Ca, <bold>(B)</bold> Co, <bold>(C)</bold> Cu, <bold>(D)</bold> Fe, <bold>(E)</bold> K, <bold>(F)</bold> Mg, <bold>(G)</bold> Mn, <bold>(H)</bold> Na, <bold>(I)</bold> P and <bold>(J)</bold> Zn determined in RM-Agro E3001a - Bovine Liver by MIP-OES.</p>
</caption>
<graphic xlink:href="frans-05-1527110-g003.tif"/>
</fig>
<table-wrap id="T2" position="float">
<label>TABLE 2</label>
<caption>
<p>Slopes and R<sup>2</sup> values comparison for the 10 analytes analyzed across MEC-ICP-OES and MEC-MIP-OES techniques in RM-Agro E3001a - Bovine Liver and MRC20-Corn grain.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="left"/>
<th colspan="4" align="center">MEC- ICP-OES</th>
<th colspan="4" align="center">MEC- MIP-OES</th>
</tr>
<tr>
<th rowspan="2" align="center">Analytes</th>
<th colspan="2" align="center">RM-agro E3001a (Bovine Liver)</th>
<th colspan="2" align="center">MRC20 (corn Grain)</th>
<th colspan="2" align="center">RM-agro E3001a (Bovine Liver)</th>
<th colspan="2" align="center">MRC20 (corn Grain)</th>
</tr>
<tr>
<th align="center">Slope</th>
<th align="center">R<sup>2</sup>
</th>
<th align="center">Slope</th>
<th align="center">R<sup>2</sup>
</th>
<th align="center">Slope</th>
<th align="center">R<sup>2</sup>
</th>
<th align="center">Slope</th>
<th align="center">R<sup>2</sup>
</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="center">Ca</td>
<td align="center">0.0141</td>
<td align="center">0.9998</td>
<td align="center">
<bold>0.0084</bold>
</td>
<td align="center">0.9857</td>
<td align="center">0.4151</td>
<td align="center">1.000</td>
<td align="center">0.1866</td>
<td align="center">1.000</td>
</tr>
<tr>
<td align="center">Co</td>
<td align="center">0.2292</td>
<td align="center">1.000</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">0.9150</td>
<td align="center">0.9983</td>
<td align="center">-</td>
<td align="center">-</td>
</tr>
<tr>
<td align="center">Cu</td>
<td align="center">0.5478</td>
<td align="center">0.9998</td>
<td align="center">
<bold>0.0117</bold>
</td>
<td align="center">0.9939</td>
<td align="center">0.5572</td>
<td align="center">0.9999</td>
<td align="center">0.3398</td>
<td align="center">0.9660</td>
</tr>
<tr>
<td align="center">Fe</td>
<td align="center">0.5004</td>
<td align="center">0.9990</td>
<td align="center">0.1037</td>
<td align="center">0.9998</td>
<td align="center">0.4117</td>
<td align="center">0.9921</td>
<td align="center">0.5521</td>
<td align="center">0.9894</td>
</tr>
<tr>
<td align="center">K</td>
<td align="center">0.5043</td>
<td align="center">1.000</td>
<td align="center">0.2236</td>
<td align="center">1.000</td>
<td align="center">0.4955</td>
<td align="center">0.9953</td>
<td align="center">0.4638</td>
<td align="center">1.000</td>
</tr>
<tr>
<td align="center">Mg</td>
<td align="center">0.2094</td>
<td align="center">1.000</td>
<td align="center">0.3575</td>
<td align="center">1.000</td>
<td align="center">0.4170</td>
<td align="center">0.9990</td>
<td align="center">0.4423</td>
<td align="center">0.9993</td>
</tr>
<tr>
<td align="center">Mn</td>
<td align="center">
<bold>0.0358</bold>
</td>
<td align="center">0.9989</td>
<td align="center">
<bold>0.0301</bold>
</td>
<td align="center">0.9994</td>
<td align="center">0.5274</td>
<td align="center">0.9963</td>
<td align="center">0.5011</td>
<td align="center">0.9991</td>
</tr>
<tr>
<td align="center">Na</td>
<td align="center">0.4494</td>
<td align="center">1.000</td>
<td align="center">
<bold>0.0450</bold>
</td>
<td align="center">1.000</td>
<td align="center">0.4323</td>
<td align="center">0.9999</td>
<td align="center">0.5649</td>
<td align="center">1.000</td>
</tr>
<tr>
<td align="center">P</td>
<td align="center">0.5533</td>
<td align="center">0.9979</td>
<td align="center">0.2430</td>
<td align="center">0.9991</td>
<td align="center">0.4834</td>
<td align="center">0.9999</td>
<td align="center">0.4477</td>
<td align="center">0.9025</td>
</tr>
<tr>
<td align="center">Zn</td>
<td align="center">
<bold>0.0643</bold>
</td>
<td align="center">0.9987</td>
<td align="center">
<bold>0.0114</bold>
</td>
<td align="center">0.9970</td>
<td align="center">0.4990</td>
<td align="center">0.9944</td>
<td align="center">0.5182</td>
<td align="center">0.9984</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>Slope values for ICP-OES falls outside the recommended range, particularly in bovine liver where it could be seen a lower range for Ca, Mn and Zn (between 0.0141 (Ca) and 0.0643 (Zn)), while for Co, Cu, Fe, K, Mg, Na and P the range was 0.2292 (Co) and 0.5533 (P); in the case of maize 0.0084 (Ca) and 0.045 (Na) for Ca, Cu, Mn, Na and Zn, while for Fe, K, Mg and P the range was 0.1037 (Fe) and 0.243 (P). MIP-OES has slope values in the range between 0.4117 (Fe) and 0.5572 (Cu) and Co showing a value close to 0.9150, for bovine liver (<xref ref-type="table" rid="T2">Table 2</xref>). Whereas for corn grains, the lowest slope corresponds to Ca (0.1866) and the highest to Na (0.5649). According to Santos et al. and Virgilio et al., this discrepancy in slopes could be due to an imbalance between the analyte concentrations in the calibration solutions (C_std) and the sample (C_sam) (<xref ref-type="bibr" rid="B32">Santos et al., 2024</xref>; <xref ref-type="bibr" rid="B41">Virgilio et al., 2020</xref>). This mismatch between the standard and sample concentrations can lead to slope values outside the ideal range. Therefore, adjusting the concentrations of the calibration solutions to be closer to those of the sample, would help to better align the slopes with the optimal range (<xref ref-type="bibr" rid="B32">Santos et al., 2024</xref>). As was discussed above, some ICP-OES calibration slopes fall outside the recommended range; however, MEC still maintains high recovery rates (<xref ref-type="table" rid="T3">Table 3</xref>), demonstrating that it can handle non-ideal slope values while preserving accuracy. To assess the concentration mismatch in the reference material, a proficiency test material, &#x201c;Animal Mineral Supplements&#x201d; (SM18-03), was analyzed. As shown in <xref ref-type="sec" rid="s10">Supplementary Table S3</xref> and <xref ref-type="sec" rid="s10">Supplementary Figure S3</xref>, the slopes for elements Ca, Co, Cu, Fe, K, Mg, Mn, Na, P, and Zn ranged from 0.2221 (P) to 0.9907 (Ca). Thus, it is evident that the use of multiple wavelengths for calibration compensates for spectral and matrix interferences.</p>
<table-wrap id="T3" position="float">
<label>TABLE 3</label>
<caption>
<p>Comparative concentration results (mean &#xb1; confidence interval; n &#x3d; 3 replicates) and recovery percentages (%) for the determination of Ca, Co, Cu, Fe, K, Mg, Mn, Na, P, and Zn (mg kg&#x207b;<sup>1</sup>) in the reference material RM-Agro E3001a - Bovine Liver, using EC and MEC calibrations with ICP-OES and MIP-OES.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th rowspan="4" align="left">Analytes</th>
<th colspan="9" align="center">RM-agro E3001a - Bovine Liver</th>
</tr>
<tr>
<th rowspan="3" align="center">Certified value [mg kg<sup>-1</sup>]</th>
<th colspan="4" align="center">ICP-OES</th>
<th colspan="4" align="center">MIP-OES</th>
</tr>
<tr>
<th colspan="2" align="center">EC</th>
<th colspan="2" align="center">MEC</th>
<th colspan="2" align="center">EC</th>
<th colspan="2" align="center">MEC</th>
</tr>
<tr>
<th align="center">Found concentration [mg kg<sup>-1</sup>]</th>
<th align="center">Recovery [%]</th>
<th align="center">Found concentration [mg kg<sup>-1</sup>]</th>
<th align="center">Recovery [%]</th>
<th align="center">Found concentration [mg kg<sup>-1</sup>]</th>
<th align="center">Recovery [%]</th>
<th align="center">Found concentration [mg kg<sup>-1</sup>]</th>
<th align="center">Recovery [%]</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="center">Ca</td>
<td align="center">182 &#xb1; 12</td>
<td align="center">190 &#xb1; 10</td>
<td align="center">104</td>
<td align="center">143 &#xb1; 1</td>
<td align="center">79</td>
<td align="center">218 &#xb1; 35</td>
<td align="center">120</td>
<td align="center">141 &#xb1; 3</td>
<td align="center">78</td>
</tr>
<tr>
<td align="center">Co</td>
<td align="center">0.3 &#xb1; 0.1</td>
<td align="center">0.3 &#xb1; 0.1</td>
<td align="center">93</td>
<td align="center">0.3 &#xb1; 0.1</td>
<td align="center">97</td>
<td align="center">0.3 &#xb1; 0.1</td>
<td align="center">102</td>
<td align="center">0.4 &#xb1; 0.1</td>
<td align="center">102</td>
</tr>
<tr>
<td align="center">Cu</td>
<td align="center">233 &#xb1; 6</td>
<td align="center">202 &#xb1; 37</td>
<td align="center">87</td>
<td align="center">244 &#xb1; 11</td>
<td align="center">105</td>
<td align="center">201 &#xb1; 1</td>
<td align="center">82</td>
<td align="center">238 &#xb1; 28</td>
<td align="center">102</td>
</tr>
<tr>
<td align="center">Fe</td>
<td align="center">200 &#xb1; 30</td>
<td align="center">141 &#xb1; 49</td>
<td align="center">71</td>
<td align="center">196 &#xb1; 4</td>
<td align="center">98</td>
<td align="center">231 &#xb1; 2</td>
<td align="center">115</td>
<td align="center">163 &#xb1; 1</td>
<td align="center">81</td>
</tr>
<tr>
<td align="center">K</td>
<td align="center">11,330 &#xb1; 910</td>
<td align="center">10,100 &#xb1; 200</td>
<td align="center">89</td>
<td align="center">10,149 &#xb1; 200</td>
<td align="center">90</td>
<td align="center">10,448 &#xb1; 240</td>
<td align="center">92</td>
<td align="center">11,198 &#xb1; 144</td>
<td align="center">99</td>
</tr>
<tr>
<td align="center">Mg</td>
<td align="center">773 &#xb1; 95</td>
<td align="center">500 &#xb1; 100</td>
<td align="center">65</td>
<td align="center">660 &#xb1; 16</td>
<td align="center">85</td>
<td align="center">661 &#xb1; 6</td>
<td align="center">86</td>
<td align="center">789 &#xb1; 36</td>
<td align="center">102</td>
</tr>
<tr>
<td align="center">Mn</td>
<td align="center">8 &#xb1; 1</td>
<td align="center">7 &#xb1; 1</td>
<td align="center">88</td>
<td align="center">8 &#xb1; 1</td>
<td align="center">100</td>
<td align="center">9 &#xb1; 1</td>
<td align="center">108</td>
<td align="center">8 &#xb1; 1</td>
<td align="center">101</td>
</tr>
<tr>
<td align="center">Na</td>
<td align="center">2,631 &#xb1; 72</td>
<td align="center">2,300 &#xb1; 400</td>
<td align="center">87</td>
<td align="center">2,395 &#xb1; 169</td>
<td align="center">91</td>
<td align="center">2,579 &#xb1; 513</td>
<td align="center">98</td>
<td align="center">2,164 &#xb1; 46</td>
<td align="center">82</td>
</tr>
<tr>
<td align="center">P</td>
<td align="center">15,650 &#xb1; 1,280</td>
<td align="center">12,500 &#xb1; 700</td>
<td align="center">80</td>
<td align="center">12,809 &#xb1; 264</td>
<td align="center">82</td>
<td align="center">13,306 &#xb1; 27</td>
<td align="center">85</td>
<td align="center">12,975 &#xb1; 1744</td>
<td align="center">83</td>
</tr>
<tr>
<td align="center">Zn</td>
<td align="center">176 &#xb1; 7</td>
<td align="center">137 &#xb1; 29</td>
<td align="center">78</td>
<td align="center">172 &#xb1; 1</td>
<td align="center">98</td>
<td align="center">125 &#xb1; 1</td>
<td align="center">71</td>
<td align="center">140 &#xb1; 7</td>
<td align="center">80</td>
</tr>
</tbody>
</table>
</table-wrap>
</sec>
<sec id="s3-2">
<title>3.2 MEC vs. EC recoveries</title>
<p>The traditional EC and MEC methods accuracy was evaluated by analysis of the reference material RM-Agro E3001a (Bovine Liver). The concentrations of Ca, Co, Cu, Fe, K, Mg, Mn, Na, P, and Zn determined using EC by ICP-OES and MIP-OES; and MEC by ICP-OES and MIP-OES are presented in <xref ref-type="table" rid="T3">Table 3</xref>. The concentrations for MEC were calculated according to <xref ref-type="sec" rid="s2-5">Section 2.5</xref>; <xref ref-type="disp-formula" rid="e1">Equation 1</xref>. For ICP-OES analysis, recoveries ranged from 80% to 104% for EC (Fe, Mg, and Zn did not reach 80% recovery), and from 82% to 105% for MEC. For MIP-OES, recoveries ranged from 82% to 120% for EC (Zn did not reach 80% recovery), and from 80% to 102% for MEC. In both MEC-ICP-OES and MEC-MIP-OES, Ca recoveries are nearly identical, approaching 80%. As could be seen, MEC showed similar recovery improvements in both ICP-OES and MIP-OES, with quantitative recoveries, indicating that it provides a reliable calibration for both plasma techniques. Although concentration imbalance can influence the slope, MEC, however, is less dependent on slope values because it relies on multiple calibration points derived from different energy transitions. This means that even if the slope is slightly outside range (0.1&#x2013;0.9), MEC can still produce accurate results, as observed with elements like Ca, Cu, Mn, Na, and Zn. Quantitative recoveries indicate that MEC effectively mitigates matrix effects, which might otherwise skew results in complex samples like bovine liver. This is especially evident where MEC provides significantly better recoveries compared to EC (e.g., Zn in ICP-OES and MIP-OES). Additionally, <xref ref-type="sec" rid="s10">Supplementary Table S4</xref> compares analytes recoveries in reference material MRC20-Maize grain by ICP-OES and MIP-OES using MEC.</p>
<p>To continue comparing the results of MEC with EC calibration for ICP-OES and MIP-OES, key figures of merit such as LOD, LOQ, and precision (%Relative Standard Deviation (RSD)) were evaluated.</p>
</sec>
<sec id="s3-3">
<title>3.3 Analytical performance</title>
<p>LOD and LOQ calculated according to IUPAC guidelines may not be fully appropriated for the MEC calibration method, as they mainly consider deviations in blank measurements as the primary error source (<xref ref-type="bibr" rid="B41">Virgilio et al., 2020</xref>). In contrast, for multi-signal calibration methods like MEC, it is essential to incorporate errors arising from both the slope and the intercept, as multiple calibration plots are generated based on the number of replicates (<xref ref-type="sec" rid="s2-6">Section 2.6</xref>; <xref ref-type="disp-formula" rid="e2">Equations 2</xref>, <xref ref-type="disp-formula" rid="e3">3</xref>).</p>
<p>The analytical performance results are shown in <xref ref-type="table" rid="T4">Table 4</xref>. The developed procedure achieved LOQs ranging from 0.4&#xa0;mg&#xa0;kg&#x207b;<sup>1</sup> for Co to 195&#xa0;mg&#xa0;kg&#x207b;<sup>1</sup> for K by EC-ICP-OES and 0.09&#xa0;mg&#xa0;kg&#x207b;<sup>1</sup> for Mn to 31&#xa0;mg&#xa0;kg&#x207b;<sup>1</sup> for Ca and Na by MEC-ICP-OES; and 2.0&#xa0;mg&#xa0;kg&#x207b;<sup>1</sup> for Mg to 607&#xa0;mg&#xa0;kg&#x207b;<sup>1</sup> for Fe by EC-MIP-OES and 0.08&#xa0;mg&#xa0;kg&#x207b;<sup>1</sup> for Mn to 354&#xa0;mg&#xa0;kg&#x207b;<sup>1</sup> for P by MEC-MIP-OES. Consistently with Alencar et al. and Gon&#xe7;alvez et al. MEC can often yield LODs an order of magnitude lower than EC calibration (<xref ref-type="bibr" rid="B1">Alencar et al., 2019</xref>; <xref ref-type="bibr" rid="B19">Gon&#xe7;alves et al., 2019</xref>). As it could be seen in <xref ref-type="table" rid="T4">Table 4</xref>, MEC achieves lower LOQs compared to EC, except for Co and Na in MIP-OES, and for Co in ICP-OES; while Cu, Na and Zn have the same order of magnitude in ICP. This is primarily because MEC can leverage multiple wavelengths (or energy levels) for calibration, increasing signal-to-noise ratios and enhancing sensitivity. In contrast, EC relies on single wavelengths for each analyte, which may limit sensitivity. EC methods could suffer from higher background noise in complex matrices, making LOQs typically higher than those observed with MEC, especially in the lower plasma temperature, where reductions of up to two orders of magnitude can be observed in MIP-OES (Ca, Cu, Fe, Mg, and Mn) (<xref ref-type="bibr" rid="B1">Alencar et al., 2019</xref>; <xref ref-type="bibr" rid="B29">Oliveira et al., 2018</xref>).</p>
<table-wrap id="T4" position="float">
<label>TABLE 4</label>
<caption>
<p>Analytical figures of merits for EC and MEC, by ICP-OES and MIP-OES.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th align="left"/>
<th colspan="6" align="center">ICP-OES</th>
<th colspan="6" align="center">MIP-OES</th>
</tr>
<tr>
<th rowspan="2" align="center">Analytes</th>
<th colspan="3" align="center">EC</th>
<th colspan="3" align="center">MEC</th>
<th colspan="3" align="center">EC</th>
<th colspan="3" align="center">MEC</th>
</tr>
<tr>
<th align="center">LOD [mg kg<sup>-1</sup>]</th>
<th align="center">LOQ [mg kg<sup>-1</sup>]</th>
<th align="center">RSD [%]</th>
<th align="center">LOD [mg kg<sup>-1</sup>]</th>
<th align="center">LOQ [mg kg<sup>-1</sup>]</th>
<th align="center">RSD [%]</th>
<th align="center">LOD [mg kg<sup>-1</sup>]</th>
<th align="center">LOQ [mg kg<sup>-1</sup>]</th>
<th align="center">RSD [%]</th>
<th align="center">LOD [mg kg<sup>-1</sup>]</th>
<th align="center">LOQ [mg kg<sup>-1</sup>]</th>
<th align="center">RSD [%]</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="center">Ca</td>
<td align="center">16</td>
<td align="center">53</td>
<td align="center">2.6</td>
<td align="center">9</td>
<td align="center">31</td>
<td align="center">3.5</td>
<td align="center">1.9</td>
<td align="center">5.7</td>
<td align="center">2.7</td>
<td align="center">0.08</td>
<td align="center">0.28</td>
<td align="center">0.6</td>
</tr>
<tr>
<td align="center">Co</td>
<td align="center">0.12</td>
<td align="center">0.40</td>
<td align="center">2.2</td>
<td align="center">0.50</td>
<td align="center">1.6</td>
<td align="center">8.8</td>
<td align="center">3.3</td>
<td align="center">9.9</td>
<td align="center">0.7</td>
<td align="center">68</td>
<td align="center">227</td>
<td align="center">1.2</td>
</tr>
<tr>
<td align="center">Cu</td>
<td align="center">0.15</td>
<td align="center">0.49</td>
<td align="center">4.5</td>
<td align="center">0.20</td>
<td align="center">0.70</td>
<td align="center">7.7</td>
<td align="center">2.6</td>
<td align="center">7.9</td>
<td align="center">8</td>
<td align="center">0.05</td>
<td align="center">0.16</td>
<td align="center">0.7</td>
</tr>
<tr>
<td align="center">Fe</td>
<td align="center">1</td>
<td align="center">2</td>
<td align="center">3.5</td>
<td align="center">0.10</td>
<td align="center">0.50</td>
<td align="center">2.3</td>
<td align="center">200</td>
<td align="center">607</td>
<td align="center">5.2</td>
<td align="center">1.0</td>
<td align="center">3.3</td>
<td align="center">0.7</td>
</tr>
<tr>
<td align="center">K</td>
<td align="center">58</td>
<td align="center">195</td>
<td align="center">3.9</td>
<td align="center">1.5</td>
<td align="center">4.8</td>
<td align="center">4.2</td>
<td align="center">4.3</td>
<td align="center">11</td>
<td align="center">2.3</td>
<td align="center">0.30</td>
<td align="center">0.99</td>
<td align="center">0.4</td>
</tr>
<tr>
<td align="center">Mg</td>
<td align="center">5</td>
<td align="center">17</td>
<td align="center">2.9</td>
<td align="center">0.70</td>
<td align="center">2.2</td>
<td align="center">4.5</td>
<td align="center">0.67</td>
<td align="center">2.0</td>
<td align="center">4.8</td>
<td align="center">0.03</td>
<td align="center">0.11</td>
<td align="center">0.8</td>
</tr>
<tr>
<td align="center">Mn</td>
<td align="center">0.18</td>
<td align="center">0.59</td>
<td align="center">5.3</td>
<td align="center">0.03</td>
<td align="center">0.09</td>
<td align="center">4.7</td>
<td align="center">2.8</td>
<td align="center">8.5</td>
<td align="center">3</td>
<td align="center">0.02</td>
<td align="center">0.08</td>
<td align="center">1.1</td>
</tr>
<tr>
<td align="center">Na</td>
<td align="center">14</td>
<td align="center">47</td>
<td align="center">3.2</td>
<td align="center">9</td>
<td align="center">31</td>
<td align="center">5.3</td>
<td align="center">3.9</td>
<td align="center">11.7</td>
<td align="center">6.5</td>
<td align="center">32</td>
<td align="center">107</td>
<td align="center">0.1</td>
</tr>
<tr>
<td align="center">P</td>
<td align="center">22</td>
<td align="center">75</td>
<td align="center">4.2</td>
<td align="center">8</td>
<td align="center">28</td>
<td align="center">2.6</td>
<td align="center">156</td>
<td align="center">474</td>
<td align="center">2.6</td>
<td align="center">106</td>
<td align="center">354</td>
<td align="center">5.0</td>
</tr>
<tr>
<td align="center">Zn</td>
<td align="center">0.32</td>
<td align="center">1.08</td>
<td align="center">5.7</td>
<td align="center">0.30</td>
<td align="center">0.90</td>
<td align="center">1.2</td>
<td align="center">7.8</td>
<td align="center">23</td>
<td align="center">2.1</td>
<td align="center">0.40</td>
<td align="center">1.40</td>
<td align="center">1.2</td>
</tr>
</tbody>
</table>
</table-wrap>
<p>As shown in <xref ref-type="table" rid="T5">Table 5</xref>, the use of MEC as a methodology in this study resulted in exceptional LODs for several elements. The best LODs for Ca, Cu, K, and Mg were achieved in this work using MEC-MIP-OES, demonstrating its capability to enhance sensitivity for these elements. For Co, the LODs reported by <xref ref-type="bibr" rid="B6">Barros et al., 2019</xref> for a urine matrix were lower than those obtained in this study, highlighting that matrix effects can influence LODs even when using advanced calibration methods like MEC.</p>
<table-wrap id="T5" position="float">
<label>TABLE 5</label>
<caption>
<p>Comparison of LODs achieved with MEC using ICP-OES and MIP-OES.</p>
</caption>
<table>
<thead valign="top">
<tr>
<th colspan="10" align="center">LOD [&#xb5;g L<sup>-1</sup>]</th>
<th rowspan="2" align="center">Technique</th>
<th rowspan="2" align="left">References</th>
</tr>
<tr>
<th align="center">Ca</th>
<th align="center">Co</th>
<th align="center">Cu</th>
<th align="center">Fe</th>
<th align="center">K</th>
<th align="center">Mg</th>
<th align="center">Mn</th>
<th align="center">Na</th>
<th align="center">P</th>
<th align="center">Zn</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="center">1</td>
<td align="center">1</td>
<td align="center">1</td>
<td align="center">15</td>
<td align="center">4</td>
<td align="center">0.5</td>
<td align="center">0.3</td>
<td align="center">0.5</td>
<td align="center">1,610</td>
<td align="center">6</td>
<td rowspan="2" align="center">MIP-OES</td>
<td rowspan="4" align="left">this work</td>
</tr>
<tr>
<td align="center">0.08&#x2a;</td>
<td align="center">68&#x2a;</td>
<td align="center">0.05&#x2a;</td>
<td align="center">1&#x2a;</td>
<td align="center">0.30&#x2a;</td>
<td align="center">0.03&#x2a;</td>
<td align="center">0.02&#x2a;</td>
<td align="center">&#x2a;32</td>
<td align="center">106&#x2a;</td>
<td align="center">0.4&#x2a;</td>
</tr>
<tr>
<td align="center">200</td>
<td align="center">10</td>
<td align="center">4</td>
<td align="center">3</td>
<td align="center">29</td>
<td align="center">14</td>
<td align="center">1</td>
<td align="center">188</td>
<td align="center">167</td>
<td align="center">5</td>
<td rowspan="2" align="center">ICP-OES</td>
</tr>
<tr>
<td align="center">9&#x2a;</td>
<td align="center">0.50&#x2a;</td>
<td align="center">0.20&#x2a;</td>
<td align="center">0.10&#x2a;</td>
<td align="center">1.5&#x2a;</td>
<td align="center">0.70&#x2a;</td>
<td align="center">0.03&#x2a;</td>
<td align="center">9</td>
<td align="center">8</td>
<td align="center">0.30</td>
</tr>
<tr>
<td align="center">11.88&#x2a;</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">2.35&#x2a;</td>
<td align="center">2.57&#x2a;</td>
<td align="center">3.05&#x2a;</td>
<td align="center">5.78&#x2a;</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">MIP-OES</td>
<td align="left">
<xref ref-type="bibr" rid="B32">Santos et al. (2024)</xref>
</td>
</tr>
<tr>
<td align="center">50</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">9</td>
<td align="center">59</td>
<td align="center">-</td>
<td align="center">131</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">MIP-OES</td>
<td align="left">
<xref ref-type="bibr" rid="B13">Cruz et al. (2024)</xref>
</td>
</tr>
<tr>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">1.3</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">0.15</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">3.1</td>
<td align="center">MIP-OES</td>
<td align="left">
<xref ref-type="bibr" rid="B7">Carneiro and Dias (2021)</xref>
</td>
</tr>
<tr>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">1</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">ICP-OES</td>
<td align="left">
<xref ref-type="bibr" rid="B41">Virgilio et al. (2020)</xref>
</td>
</tr>
<tr>
<td align="center">0.6&#x2a;</td>
<td align="center">-</td>
<td align="center">0.1&#x2a;</td>
<td align="center">-</td>
<td align="center">1.5&#x2a;</td>
<td align="center">0.06&#x2a;</td>
<td align="center">0.02&#x2a;</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">0.03&#x2a;</td>
<td align="center">ICP-OES</td>
<td align="left">
<xref ref-type="bibr" rid="B31">Pereira et al. (2020)</xref>
</td>
</tr>
<tr>
<td align="center">20</td>
<td align="center">-</td>
<td align="center">10</td>
<td align="center">1</td>
<td align="center">100</td>
<td align="center">2</td>
<td align="center">-</td>
<td align="center">200</td>
<td align="center">50</td>
<td align="center">60</td>
<td rowspan="2" align="center">ICP-OES</td>
<td rowspan="2" align="left">
<xref ref-type="bibr" rid="B20">Higuera et al. (2019)</xref>
</td>
</tr>
<tr>
<td align="center">6&#x2a;</td>
<td align="center">-</td>
<td align="center">3&#x2a;</td>
<td align="center">0.3&#x2a;</td>
<td align="center">0.4&#x2a;</td>
<td align="center">0.7&#x2a;</td>
<td align="center">-</td>
<td align="center">0.6&#x2a;</td>
<td align="center">0.1&#x2a;</td>
<td align="center">19&#x2a;</td>
</tr>
<tr>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">1</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">ICP-OES</td>
<td align="left">
<xref ref-type="bibr" rid="B19">Gon&#xe7;alves et al. (2019)</xref>
</td>
</tr>
<tr>
<td align="center">15</td>
<td align="center">2.9</td>
<td align="center">5.7</td>
<td align="center">-</td>
<td align="center">70</td>
<td align="center">43</td>
<td align="center">-</td>
<td align="center">120</td>
<td align="center">-</td>
<td align="center">9.8</td>
<td align="center">ICP-OES</td>
<td align="left">
<xref ref-type="bibr" rid="B6">Barros, Pinheiro, and N&#xf3;brega (2019)</xref>
</td>
</tr>
<tr>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">2</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">MIP-OES</td>
<td rowspan="2" align="left">
<xref ref-type="bibr" rid="B40">Virgilio et al. (2017)</xref>
</td>
</tr>
<tr>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">0.7</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">0.8</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">-</td>
<td align="center">ICP-OES</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn>
<p>&#x2a;[&#xb5;g g<sup>-1</sup>].</p>
</fn>
</table-wrap-foot>
</table-wrap>
<p>The LODs for Cu obtained in this study are consistent with those reported in the literature, falling within the same order of magnitude, showcasing MEC&#x2019;s reliability in achieving comparable performance. For Fe, while <xref ref-type="bibr" rid="B20">Higuera et al., 2019</xref> reported the lowest LODs in &#x3bc;g&#xa0;L&#x207b;<sup>1</sup> for a meat matrix using ICP-OES, the best LODs expressed in &#x3bc;g&#xa0;g&#x207b;<sup>1</sup> were obtained in this study when MEC-ICP-OES was employed, underscoring the robustness of MEC for solid sample matrices. Similarly, for Mn, the LODs achieved using both MEC-MIP-OES and MEC-ICP-OES are similar to those reported by <xref ref-type="bibr" rid="B31">Pereira et al., 2020</xref>, further supporting MEC&#x2019;s effectiveness across techniques.</p>
<p>A particularly noteworthy result was observed for Na, where the MEC-MIP-OES methodology yielded LODs that were four orders of magnitude lower than those reported in other studies, demonstrating a significant improvement in sensitivity. In contrast, for P, the LODs obtained using MEC in this study were four (ICP-OES) and five (MIP-OES) orders of magnitude higher than those reported by <xref ref-type="bibr" rid="B20">Higuera et al., 2019</xref>, suggesting potential challenges in achieving optimal sensitivity for this element under the tested conditions.</p>
<p>Finally, for Zn, the LODs achieved in this study are of the same order of magnitude as those reported by <xref ref-type="bibr" rid="B7">Carneiro and Dias 2021</xref> for MIP-OES and <xref ref-type="bibr" rid="B6">Barros et al., 2019</xref> for ICP-OES, with the best sensitivity observed in Carneiro and Dias&#x2019; study. These findings highlight MEC&#x2019;s significant advantages in improving sensitivity and addressing matrix effects while indicating opportunities for refinement in certain cases. Overall, MEC demonstrates its utility as a powerful calibration strategy for improving the detection of multiple elements in complex matrices.</p>
<p>In all cases, the MEC precision, expressed as %RSD, was better than 8.8% in ICP-OES and 1.2% in MIP-OES. For ICP-OES, only Fe, Mn, P and Zn exhibited lower RSD in MEC compared to EC. MEC-MIP-OES consistently demonstrated lower RSD for all analytes, indicating more precise measurements.</p>
<p>MEC demonstrated enhanced accuracy over EC, largely due to its matrix-matching capabilities, which provided higher trueness and precision. Analytes such as Co, Fe, Na, and P are more effectively determined by MEC-ICP-OES, while Ca, Cu, K, and Mg are better suited to MEC-MIP-OES, but both instrumental techniques led to accurate results for all analytes. Manganese and Zn show comparable performance with both methods.</p>
</sec>
<sec id="s3-4">
<title>3.4 Analytical application for animal feed quality assurance</title>
<p>The MEC method was applied to analyze animal feed samples and assess the mineral nutritional composition of the feed. This data is essential for formulating balanced rations and could directly influence pig growth.</p>
<p>The excesses or deficiencies of minerals such as Ca, Co, Cu, Fe, K, Mg, Mn, Na, P, and Zn can lead to nutritional imbalances in swine, affecting their health and productivity (<xref ref-type="bibr" rid="B26">McDowell, 1992</xref>; <xref ref-type="bibr" rid="B30">Patience, 1996</xref>; <xref ref-type="bibr" rid="B15">Fab&#xe0; et al., 2019</xref>). To address this, the developed MEC-ICP-OES and MEC-MIP-OES procedure was applied to determine these essential mineral nutrients in pig feed samples (<xref ref-type="fig" rid="F4">Figure 4</xref>).</p>
<fig id="F4" position="float">
<label>FIGURE 4</label>
<caption>
<p>Determination of Ca, Co, Cu, Fe, K, Mg, Mn, Na, P, and Zn by MEC-MIP-OES and MEC-ICP-OES in different categories of animal feed samples. Results are reported as mean &#xb1; confidence interval (n &#x3d; 3). Dietary mineral requirements for growing pigs, gestating sows, and lactating sows, as specified by <xref ref-type="bibr" rid="B11">National Research Council (2011)</xref>, are indicated by a black line in the graph for reference.</p>
</caption>
<graphic xlink:href="frans-05-1527110-g004.tif"/>
</fig>
<p>The mineral concentrations obtained were then compared to the dietary mineral requirements for different physiological stages of swine (marked by a black line in <xref ref-type="fig" rid="F4">Figure 4</xref>), including growing pigs, gestating sows, and lactating sows, as defined by the Nutrient Requirements of Swine (<xref ref-type="bibr" rid="B11">National Research Council, 2012</xref>) (<xref ref-type="fig" rid="F4">Figure 4</xref>). The comparison revealed that most physiological stage samples did not meet the required nutritional levels exceeding the recommended values. However, certain minerals, such as Ca, Na, and P, in a few samples were nearly aligned with NRC guidelines. Given the variability in nutrient requirements based on numerous factors, it is essential for feed suppliers to enhance their ability to accurately define and evaluate feed ingredients. This necessitates continuous reevaluation of feed formulations to ensure they meet the minimum nutritional requirements for animals. Increased emphasis on quality control is critical to ensure accurate feed formulations for supporting optimal growth and health in swine.</p>
</sec>
<sec id="s3-5">
<title>3.5 Conclusion</title>
<p>MEC strategy has demonstrated robust and consistent performance for ICP-OES and MIP-OES. The results confirm that MEC is an effective calibration method for rapid, accurate multielement analysis with optical plasma techniques, reliably quantifying essential elements like Ca, Co, Cu, Fe, K, Mg, Mn, Na, P, and Zn with accurate recoveries.</p>
<p>This approach excels at matrix-matching in complex samples, such as biological tissues and animal feeds, offering a flexible solution that does not require instrument modifications. For laboratories already using ICP-OES or MIP-OES, MEC is an easy-to-implement enhancement to the existing instrument, reducing the need for labor-intensive matrix-matching standards and improving calibration efficiency. By optimizing the calibration process, MEC can significantly increase sample throughput and reduce analysis time.</p>
<p>While MEC presents clear advantages for multielement determination, some challenges remain. For instance, all calculations could be easier performed if proper data treatment was implemented in the built-in software that controls modern instruments. As an additional bonus, emission lines affected by interferences are easily spotted in the analytical calibration curve because they do not follow the expected linear response with analyte concentration. In this sense, if analytical chemistry can be seen as a science to generate chemical information about samples, MEC is a powerful ally because it allows bettering exploiting multiple analytical signals typically obtained when applying instrumental analysis.</p>
<p>In the context of nutritional research, such as in animal feed analysis, MEC can support improved efficiency in swine production by enabling precise mineral analysis. This is highly beneficial for producers, as reliable analytical data allow for precise feed formulation, leading to cost savings and optimized nutrition. Quality control in agri-foods, facilitated by MEC, is thus essential for ensuring that feed formulations meet nutritional standards, ultimately benefiting both suppliers and producers.</p>
</sec>
</sec>
</body>
<back>
<sec sec-type="data-availability" id="s4">
<title>Data availability statement</title>
<p>The original contributions presented in the study are included in the article/<xref ref-type="sec" rid="s10">Supplementary Material</xref>, further inquiries can be directed to the corresponding author.</p>
</sec>
<sec sec-type="author-contributions" id="s5">
<title>Author contributions</title>
<p>FC: Conceptualization, Investigation, Validation, Writing&#x2013;original draft, Writing&#x2013;review and editing, Data curation, Formal Analysis. AB: Writing&#x2013;review and editing, Methodology, Supervision. JN: Supervision, Writing&#x2013;review and editing, Funding acquisition. MS: Supervision, Writing&#x2013;review and editing, Conceptualization, Investigation, Validation, Writing&#x2013;original draft.</p>
</sec>
<sec sec-type="funding-information" id="s6">
<title>Funding</title>
<p>The author(s) declare that financial support was received for the research, authorship, and/or publication of this article. This work was financially supported by the Special fund for Universidad Nacional de La Pampa. This study was financed in part by Conselho Nacional de Desenvolvimento Cient&#xed;fico e Tecnol&#xf3;gico (CNPq &#x2013; grants 303107/2013-8, 307452/2023-9 and 428558/2018-6); Coordena&#xe7;&#xe3;o de Aperfei&#xe7;oamento de Pessoal de N&#xed;vel Superior Brasil (CAPES) &#x2013; Finance Code 001; Instituto Nacional de Ci&#xea;ncias e Tecnologias Anal&#xed;ticas Avan&#xe7;adas &#x2013; CNPq, Grant No. 573894/2008-6 and FAPESP and Grant No. 2014/50951-4.</p>
</sec>
<ack>
<p>The authors are grateful to the Consejo Nacional de Investigaciones Cientif&#xed;cas y Te&#x107;nicas (CONICET), Agencia Nacional de Promoci&#xf3;n Cientif&#xed;ca y Tecnol&#xf3;gica (ANPCYT) and Universidad Nacional de La Pampa; Conselho Nacional de Desenvolvimento Cient&#xed;fico e Tecnol&#xf3;gico (CNPq), and Coordena&#xe7;&#xe3;o de Aperfei&#xe7;oamento de Pessoal de N&#xed;vel Superior (CAPES/PNPD &#x2013; Graduate Program in Chemistry, Federal University of S&#xe3;o Carlos). We also acknowledge the technical support provided by Anal&#xed;tica (S&#xe3;o Paulo, SP, Brazil), Milestone (Sorisole, BG, Italy) and Thermo Scientific. The authors also would like to express their gratitude to the Instituto Nacional de Ci&#xea;ncias e Tecnologias Anal&#xed;ticas Avan&#xe7;adas (INCTAA), Instituto Nacional de Tecnolog&#xed;a Agropecuaria (INTA) and to swines&#x2019; producers that kindly provided samples.</p>
</ack>
<sec sec-type="COI-statement" id="s7">
<title>Conflict of interest</title>
<p>The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.</p>
</sec>
<sec sec-type="ai-statement" id="s8">
<title>Generative AI statement</title>
<p>The author(s) declare that no Generative AI was used in the creation of this manuscript.</p>
</sec>
<sec sec-type="disclaimer" id="s9">
<title>Publisher&#x2019;s note</title>
<p>All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.</p>
</sec>
<sec id="s10">
<title>Supplementary material</title>
<p>The Supplementary Material for this article can be found online at: <ext-link ext-link-type="uri" xlink:href="https://www.frontiersin.org/articles/10.3389/frans.2025.1527110/full#supplementary-material">https://www.frontiersin.org/articles/10.3389/frans.2025.1527110/full&#x23;supplementary-material</ext-link>
</p>
<supplementary-material xlink:href="DataSheet1.docx" id="SM1" mimetype="application/docx" xmlns:xlink="http://www.w3.org/1999/xlink"/>
</sec>
<ref-list>
<title>References</title>
<ref id="B1">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Alencar</surname>
<given-names>M. C.</given-names>
</name>
<name>
<surname>Gon&#xe7;alves</surname>
<given-names>D. A.</given-names>
</name>
<name>
<surname>Nicolodelli</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Oliveira</surname>
<given-names>S. L.</given-names>
</name>
<name>
<surname>Donati</surname>
<given-names>G. L.</given-names>
</name>
<name>
<surname>Caires</surname>
<given-names>A. R. L.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Evaluating the applicability of multi-energy calibration as an alternative method for quantitative molecular spectroscopy analysis</article-title>. <source>Spectrochimica Acta - Part A Mol. Biomol. Spectrosc.</source> <volume>221</volume> (<issue>October</issue>), <fpage>117221</fpage>. <pub-id pub-id-type="doi">10.1016/j.saa.2019.117221</pub-id>
</citation>
</ref>
<ref id="B2">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Augusto</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Castro</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Speran&#xe7;a</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Pereira</surname>
<given-names>E.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Combination of multi-energy calibration (MEC) and laser-induced breakdown spectroscopy (LIBS) for dietary supplements analysis and determination of Ca, Mg and K</article-title>. <source>J. Braz. Chem. Soc.</source> <pub-id pub-id-type="doi">10.21577/0103-5053.20180211</pub-id>
</citation>
</ref>
<ref id="B3">
<citation citation-type="journal">
<collab>Analytical Methods Committee</collab> (<year>2013</year>). <article-title>&#x201c;What Causes most errors in chemical analysis?&#x201d;</article-title>. <source>Anal. Methods</source> <volume>5</volume> (<issue>12</issue>), <fpage>2914</fpage>&#x2013;<lpage>2915</lpage>. <pub-id pub-id-type="doi">10.1039/C3AY90035E</pub-id>
</citation>
</ref>
<ref id="B4">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Babos</surname>
<given-names>D. V.</given-names>
</name>
<name>
<surname>Barros</surname>
<given-names>A. I.</given-names>
</name>
<name>
<surname>N&#xf3;brega</surname>
<given-names>J. A.</given-names>
</name>
<name>
<surname>Pereira-Filho</surname>
<given-names>E. R.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Calibration strategies to overcome matrix effects in laser-induced breakdown spectroscopy: direct calcium and phosphorus determination in solid mineral supplements</article-title>. <source>Spectrochim. Acta Part B At. Spectrosc.</source> <volume>155</volume> (<issue>1</issue>), <fpage>90</fpage>&#x2013;<lpage>98</lpage>. <pub-id pub-id-type="doi">10.1016/j.sab.2019.03.010</pub-id>
</citation>
</ref>
<ref id="B5">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Babos</surname>
<given-names>D. V.</given-names>
</name>
<name>
<surname>Virgilio</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Costa</surname>
<given-names>V. C.</given-names>
</name>
<name>
<surname>Donati</surname>
<given-names>G. L.</given-names>
</name>
<name>
<surname>Pereira-Filho</surname>
<given-names>E. R.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Multi-energy calibration (MEC) applied to laser-induced breakdown spectroscopy (LIBS)</article-title>. <source>J. Anal. Atomic Spectrom.</source> <volume>33</volume> (<issue>10</issue>), <fpage>1753</fpage>&#x2013;<lpage>1762</lpage>. <pub-id pub-id-type="doi">10.1039/C8JA00109J</pub-id>
</citation>
</ref>
<ref id="B6">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Barros</surname>
<given-names>A. I.</given-names>
</name>
<name>
<surname>Pinheiro</surname>
<given-names>F. C.</given-names>
</name>
<name>
<surname>N&#xf3;brega</surname>
<given-names>J. A.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Calibration strategies to correct for matrix effects in direct analysis of urine by ICP OES: internal standardization and multi-energy calibration</article-title>. <source>Anal. Methods</source> <volume>11</volume> (<issue>27</issue>), <fpage>3401</fpage>&#x2013;<lpage>3409</lpage>. <pub-id pub-id-type="doi">10.1039/C9AY00907H</pub-id>
</citation>
</ref>
<ref id="B16">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Beily</surname>
<given-names>M. E.</given-names>
</name>
<name>
<surname>Brunori</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Campagna</surname>
<given-names>D. A.</given-names>
</name>
<name>
<surname>Cottura</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>Crespo</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Denegri</surname>
<given-names>G. D.</given-names>
</name>
</person-group> (<year>2011</year>). &#x201c;<article-title>Buenas Pr&#xe1;cticas Pecuarias (BPP) para la producci&#xf3;n y comercializaci&#xf3;n porcina familiar</article-title>,&#x201d; in <source>Instituto Nacional de Tecnolog&#xed;a Agropecuaria; Organizaci&#xf3;n de las Naciones Unidas para la Agricultura y la Alimentaci&#xf3;n</source> <volume>277</volume>. <comment>Available at: <ext-link ext-link-type="uri" xlink:href="https://www.fao.org/3/i2094s/i2094s.pdf">https://www.fao.org/3/i2094s/i2094s.pdf</ext-link>.</comment>
</citation>
</ref>
<ref id="B7">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Carneiro</surname>
<given-names>C. N.</given-names>
</name>
<name>
<surname>Dias</surname>
<given-names>F. de S.</given-names>
</name>
</person-group> (<year>2021</year>). <article-title>Multiple response optimization of ultrasound-assisted procedure for multi-element determination in Brazilian wine samples by microwave-induced plasma optical emission spectrometry</article-title>. <source>Microchem. J.</source> <volume>171</volume> (<issue>December</issue>), <fpage>106857</fpage>. <pub-id pub-id-type="doi">10.1016/j.microc.2021.106857</pub-id>
</citation>
</ref>
<ref id="B8">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Carter</surname>
<given-names>J. A.</given-names>
</name>
<name>
<surname>Barros</surname>
<given-names>A. I.</given-names>
</name>
<name>
<surname>N&#xf3;brega</surname>
<given-names>J. A.</given-names>
</name>
<name>
<surname>Donati</surname>
<given-names>G. L.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Traditional calibration methods in atomic spectrometry and new calibration strategies for inductively coupled plasma mass spectrometry</article-title>. <source>Front. Chem.</source> <volume>6</volume> (<issue>November</issue>), <fpage>504</fpage>. <pub-id pub-id-type="doi">10.3389/fchem.2018.00504</pub-id>
</citation>
</ref>
<ref id="B9">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Carvalho</surname>
<given-names>A. A. C.</given-names>
</name>
<name>
<surname>Cozer</surname>
<given-names>L. A.</given-names>
</name>
<name>
<surname>Luz</surname>
<given-names>M. S.</given-names>
</name>
<name>
<surname>Nunes</surname>
<given-names>L. C.</given-names>
</name>
<name>
<surname>Rocha</surname>
<given-names>F. R. P.</given-names>
</name>
<name>
<surname>Nomura</surname>
<given-names>C. S.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Multi-energy calibration and sample fusion as alternatives for quantitative analysis of high silicon content samples by laser-induced breakdown spectrometry</article-title>. <source>J. Anal. Atomic Spectrom.</source> <volume>34</volume> (<issue>8</issue>), <fpage>1701</fpage>&#x2013;<lpage>1707</lpage>. <pub-id pub-id-type="doi">10.1039/C9JA00149B</pub-id>
</citation>
</ref>
<ref id="B10">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Castro</surname>
<given-names>J. P.</given-names>
</name>
<name>
<surname>Babos</surname>
<given-names>D. V.</given-names>
</name>
<name>
<surname>Pereira-Filho</surname>
<given-names>E. R.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Calibration strategies for the direct determination of rare Earth elements in hard disk magnets using laser-induced breakdown spectroscopy</article-title>. <source>Talanta</source> <volume>208</volume> (<issue>February</issue>), <fpage>120443</fpage>. <pub-id pub-id-type="doi">10.1016/j.talanta.2019.120443</pub-id>
</citation>
</ref>
<ref id="B12">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Cruz</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Lizeth</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Guerrero Esperanza</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Wrobel</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Yanez Barrientos</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Aguilar</surname>
<given-names>F. J. A.</given-names>
</name>
<etal/>
</person-group> (<year>2020</year>). <article-title>Determination of major and minor elements in Mexican red wines by microwave-induced plasma optical emission spectrometry, evaluating different calibration methods and exploring potential of the obtained data in the assessment of wine provenance</article-title>. <source>Spectrochim. Acta Part B At. Spectrosc.</source> <volume>164</volume> (<issue>February</issue>), <fpage>105754</fpage>. <pub-id pub-id-type="doi">10.1016/j.sab.2019.105754</pub-id>
</citation>
</ref>
<ref id="B13">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Cruz</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Lizeth</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Wrobel</surname>
<given-names>K.</given-names>
</name>
<name>
<surname>Barrientos</surname>
<given-names>E. Y.</given-names>
</name>
<name>
<surname>Escobosa</surname>
<given-names>A. R. C.</given-names>
</name>
<name>
<surname>Garay-Sevilla</surname>
<given-names>Ma E.</given-names>
</name>
<etal/>
</person-group> (<year>2024</year>). <article-title>Determination of sodium, potassium, calcium and magnesium in urine, using microwave plasma - atomic emission spectrometry and multi-energy calibration</article-title>. <source>J. Mexican Chem. Soc.</source> <volume>68</volume> (<issue>1</issue>), <fpage>18</fpage>&#x2013;<lpage>28</lpage>. <pub-id pub-id-type="doi">10.29356/jmcs.v68i1.1906</pub-id>
</citation>
</ref>
<ref id="B14">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Donati</surname>
<given-names>G. L.</given-names>
</name>
<name>
<surname>Amais</surname>
<given-names>R. S.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Fundamentals and new approaches to calibration in atomic spectrometry</article-title>. <source>J. Anal. Atomic Spectrom.</source> <volume>34</volume> (<issue>12</issue>), <fpage>2353</fpage>&#x2013;<lpage>2369</lpage>. <pub-id pub-id-type="doi">10.1039/C9JA00273A</pub-id>
</citation>
</ref>
<ref id="B15">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Fab&#xe0;</surname>
<given-names>L.</given-names>
</name>
<name>
<surname>Gasa</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Tokach</surname>
<given-names>M. D.</given-names>
</name>
<name>
<surname>Font-i-Furnols</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Vilarrasa</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Sol&#xe0;-Oriol</surname>
<given-names>D.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Effects of additional organic micro-minerals and methionine on carcass composition, gait score, bone characteristics, and osteochondrosis in replacement gilts of different growth rate</article-title>. <source>Animal Feed Sci. Technol.</source> <volume>256</volume> (<issue>September</issue>), <fpage>114262</fpage>. <pub-id pub-id-type="doi">10.1016/j.anifeedsci.2019.114262</pub-id>
</citation>
</ref>
<ref id="B17">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Fortunato</surname>
<given-names>F. M.</given-names>
</name>
<name>
<surname>Catelani</surname>
<given-names>T. A.</given-names>
</name>
<name>
<surname>Pomares-Alfonso</surname>
<given-names>M. S.</given-names>
</name>
<name>
<surname>Pereira-Filho</surname>
<given-names>E. R.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Application of multi-energy calibration for determination of chromium and nickel in nickeliferous ores by laser-induced breakdown spectroscopy</article-title>. <source>Anal. Sci.</source> <volume>35</volume> (<issue>2</issue>), <fpage>165</fpage>&#x2013;<lpage>168</lpage>. <pub-id pub-id-type="doi">10.2116/analsci.18P286</pub-id>
</citation>
</ref>
<ref id="B18">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Garde</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Nakadi</surname>
<given-names>F. V.</given-names>
</name>
<name>
<surname>Garc&#xed;a-Ruiz</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Resano</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Introducing multi-energy ratios as an alternative to multi-energy calibration for Br determination <italic>via</italic> high-resolution continuum source graphite furnace molecular absorption spectrometry. A case study</article-title>. <source>J. Anal. Atomic Spectrom.</source> <volume>35</volume> (<issue>11</issue>), <fpage>2606</fpage>&#x2013;<lpage>2619</lpage>. <pub-id pub-id-type="doi">10.1039/D0JA00359J</pub-id>
</citation>
</ref>
<ref id="B19">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Gon&#xe7;alves</surname>
<given-names>D. A.</given-names>
</name>
<name>
<surname>Domingos de Souza</surname>
<given-names>I.</given-names>
</name>
<name>
<surname>Rosa</surname>
<given-names>A. C. G.</given-names>
</name>
<name>
<surname>Melo</surname>
<given-names>E. S. P.</given-names>
</name>
<name>
<surname>Goncalves</surname>
<given-names>A. M. B.</given-names>
</name>
<name>
<surname>de Oliveira</surname>
<given-names>L. C. S.</given-names>
</name>
<etal/>
</person-group> (<year>2019</year>). <article-title>Multi-wavelength calibration: determination of trace toxic elements in medicine plants by ICP OES</article-title>. <source>Microchem. J.</source> <volume>146</volume> (<issue>May</issue>), <fpage>381</fpage>&#x2013;<lpage>386</lpage>. <pub-id pub-id-type="doi">10.1016/j.microc.2019.01.021</pub-id>
</citation>
</ref>
<ref id="B20">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Higuera</surname>
<given-names>J. M.</given-names>
</name>
<name>
<surname>Silva</surname>
<given-names>A. B. S.</given-names>
</name>
<name>
<surname>Nogueira</surname>
<given-names>A. R. A.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Multi-energy calibration: a practical method for determination of macro and micro nutrients in meat by ICP OES</article-title>. <source>J. Braz. Chem. Soc.</source> <volume>30</volume> (<issue>12</issue>), <fpage>2575</fpage>&#x2013;<lpage>2581</lpage>. <pub-id pub-id-type="doi">10.21577/0103-5053.20190171</pub-id>
</citation>
</ref>
<ref id="B21">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Jofre</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Florencia</surname>
<given-names>D. N. L.</given-names>
</name>
<name>
<surname>Savio</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>An eco-friendly infrared method for rapid soil sample preparation for multielemental determination by microwave induced plasma atomic emission spectrometry</article-title>. <source>Microchem. J.</source> <volume>159</volume> (<issue>December</issue>), <fpage>105448</fpage>. <pub-id pub-id-type="doi">10.1016/j.microc.2020.105448</pub-id>
</citation>
</ref>
<ref id="B22">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Jofre</surname>
<given-names>F. C.</given-names>
</name>
<name>
<surname>Savio</surname>
<given-names>M.</given-names>
</name>
</person-group> (<year>2024</year>). <article-title>Infrared radiation: a sustainable and promising sample preparation alternative for inorganic analysis</article-title>. <source>TrAC Trends Anal. Chem.</source> <volume>170</volume> (<issue>1</issue>), <fpage>117469</fpage>. <pub-id pub-id-type="doi">10.1016/j.trac.2023.117469</pub-id>
</citation>
</ref>
<ref id="B23">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Li</surname>
<given-names>X.</given-names>
</name>
<name>
<surname>Zhao</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Zhong</surname>
<given-names>Q.</given-names>
</name>
<name>
<surname>Nie</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Xiao</surname>
<given-names>H.</given-names>
</name>
<name>
<surname>Zhao</surname>
<given-names>S.</given-names>
</name>
<etal/>
</person-group> (<year>2020</year>). <article-title>Iterative multi-energy calibration and its application in online alloy smelting process monitoring using laser-induced breakdown spectroscopy</article-title>. <source>J. Anal. Atomic Spectrom.</source> <volume>35</volume> (<issue>10</issue>), <fpage>2171</fpage>&#x2013;<lpage>2178</lpage>. <pub-id pub-id-type="doi">10.1039/D0JA00247J</pub-id>
</citation>
</ref>
<ref id="B24">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Machado</surname>
<given-names>R. C.</given-names>
</name>
<name>
<surname>Silva</surname>
<given-names>A. B. S.</given-names>
</name>
<name>
<surname>Donati</surname>
<given-names>G. L.</given-names>
</name>
<name>
<surname>Nogueira</surname>
<given-names>A. R. A.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Multi-energy calibration as a strategy for elemental analysis of fertilizers by microwave-induced plasma optical emission spectrometry</article-title>. <source>J. Anal. Atomic Spectrom.</source> <volume>33</volume> (<issue>7</issue>), <fpage>1168</fpage>&#x2013;<lpage>1172</lpage>. <pub-id pub-id-type="doi">10.1039/c8ja00077h</pub-id>
</citation>
</ref>
<ref id="B25">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Matusiewicz</surname>
<given-names>H.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>Sample preparation for inorganic trace element analysis</article-title>. <source>Phys. Sci. Rev.</source> <volume>2</volume> (<issue>5</issue>). <pub-id pub-id-type="doi">10.1515/psr-2017-8001</pub-id>
</citation>
</ref>
<ref id="B26">
<citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname>McDowell</surname>
<given-names>L. R.</given-names>
</name>
</person-group> (<year>1992</year>). <source>Minerals in animal and human nutrition: comparative aspects to human nutrition animal feeding and nutrition</source>. <publisher-name>Elsevier Science</publisher-name>.</citation>
</ref>
<ref id="B27">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>N&#xf3;brega</surname>
<given-names>J. A.</given-names>
</name>
<name>
<surname>Pirola</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Fialho</surname>
<given-names>L. L.</given-names>
</name>
<name>
<surname>Rota</surname>
<given-names>G.</given-names>
</name>
<name>
<surname>de Campos Jord&#xe3;o</surname>
<given-names>C. E. K. M. A.</given-names>
</name>
<name>
<surname>Pollo</surname>
<given-names>F.</given-names>
</name>
</person-group> (<year>2012</year>). <article-title>Microwave-assisted digestion of organic samples: how simple can it become?</article-title> <source>Talanta</source> <volume>98</volume> (<issue>August</issue>), <fpage>272</fpage>&#x2013;<lpage>276</lpage>. <pub-id pub-id-type="doi">10.1016/j.talanta.2012.06.079</pub-id>
</citation>
</ref>
<ref id="B11">
<citation citation-type="book">
<collab>National Research Council</collab> (<year>2012</year>). <source>Nutrient requirements of Swine: Eleventh revised edition</source>. <publisher-loc>Washington, DC</publisher-loc>: <publisher-name>The National Academies Press</publisher-name>. <pub-id pub-id-type="doi">10.17226/13298</pub-id>
</citation>
</ref>
<ref id="B28">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Novo</surname>
<given-names>D. L. R.</given-names>
</name>
<name>
<surname>Pereira</surname>
<given-names>R. M.</given-names>
</name>
<name>
<surname>Costa</surname>
<given-names>V. C.</given-names>
</name>
<name>
<surname>Hartwig</surname>
<given-names>C. A.</given-names>
</name>
<name>
<surname>Mesko</surname>
<given-names>M. F.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>A novel and eco-friendly analytical method for phosphorus and sulfur determination in animal feed</article-title>. <source>Food Chem.</source> <volume>246</volume> (<issue>April</issue>), <fpage>422</fpage>&#x2013;<lpage>427</lpage>. <pub-id pub-id-type="doi">10.1016/j.foodchem.2017.11.036</pub-id>
</citation>
</ref>
<ref id="B29">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Oliveira</surname>
<given-names>A. F.</given-names>
</name>
<name>
<surname>Gonzalez</surname>
<given-names>M. H.</given-names>
</name>
<name>
<surname>Nogueira</surname>
<given-names>A. R. A.</given-names>
</name>
</person-group> (<year>2018</year>). <article-title>Use of multiple lines for improving accuracy, minimizing systematic errors from spectral interferences, and reducing matrix effects in MIP OES measurements</article-title>. <source>Microchem. J.</source> <volume>143</volume> (<issue>December</issue>), <fpage>326</fpage>&#x2013;<lpage>330</lpage>. <pub-id pub-id-type="doi">10.1016/j.microc.2018.08.032</pub-id>
</citation>
</ref>
<ref id="B30">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Patience</surname>
<given-names>J. F.</given-names>
</name>
</person-group> (<year>1996</year>). <article-title>Precision in swine feeding programs: an integrated approach</article-title>. <source>Animal Feed Sci. Technol.</source> <volume>59</volume> (<issue>1&#x2013;3</issue>), <fpage>137</fpage>&#x2013;<lpage>145</lpage>. <pub-id pub-id-type="doi">10.1016/0377-8401(95)00894-2</pub-id>
</citation>
</ref>
<ref id="B31">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Pereira</surname>
<given-names>H. S.</given-names>
</name>
<name>
<surname>Nogueira da Silva</surname>
<given-names>K. R.</given-names>
</name>
<name>
<surname>Melo</surname>
<given-names>E. S. de P.</given-names>
</name>
<name>
<surname>Arag&#xe3;o do Nascimento</surname>
<given-names>V.</given-names>
</name>
<name>
<surname>Raposo</surname>
<given-names>J. L.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Multi-energy calibration: an easy strategy for fast and accurate determination of macro- and micro-nutrients in biomass waste samples by ICP OES</article-title>. <source>J. Anal. Atomic Spectrom.</source> <volume>35</volume> (<issue>8</issue>), <fpage>1558</fpage>&#x2013;<lpage>1565</lpage>. <pub-id pub-id-type="doi">10.1039/D0JA00189A</pub-id>
</citation>
</ref>
<ref id="B32">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Santos</surname>
<given-names>T. S.</given-names>
</name>
<name>
<surname>Arruda dos Santos</surname>
<given-names>E.</given-names>
</name>
<name>
<surname>Victor Soares de Ara&#xfa;jo</surname>
<given-names>J.</given-names>
</name>
<name>
<surname>Jad&#xe1;n-Piedra</surname>
<given-names>C.</given-names>
</name>
<name>
<surname>Jorgensen Cassella</surname>
<given-names>R.</given-names>
</name>
<name>
<surname>Duyck</surname>
<given-names>C.</given-names>
</name>
<etal/>
</person-group> (<year>2024</year>). <article-title>Multi-energy calibration and induced plasma optical emission spectrometry (MEC-MIP OES) as an alternative method for the multi-elemental determination of essential elements in cocoa</article-title>. <source>J. Food Compos. Analysis</source> <volume>136</volume> (<issue>1</issue>), <fpage>106798</fpage>. <pub-id pub-id-type="doi">10.1016/j.jfca.2024.106798</pub-id>
</citation>
</ref>
<ref id="B33">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Savio</surname>
<given-names>M.</given-names>
</name>
<name>
<surname>Fialho</surname>
<given-names>L. L.</given-names>
</name>
<name>
<surname>N&#xf3;brega</surname>
<given-names>J. A.</given-names>
</name>
</person-group> (<year>2019</year>). <article-title>Greening microwave-assisted acid digestion of animal feed samples</article-title>. <source>Anal. Methods</source> <volume>11</volume> (<issue>46</issue>), <fpage>5857</fpage>&#x2013;<lpage>5863</lpage>. <pub-id pub-id-type="doi">10.1039/C9AY01586H</pub-id>
</citation>
</ref>
<ref id="B34">
<citation citation-type="web">
<collab>SDGs</collab> (<year>2024</year>). <article-title>Sustainable development Goals</article-title>. <comment>Available at: <ext-link ext-link-type="uri" xlink:href="https://www.Un.Org/Sustainabledevelopment/">https://www.Un.Org/Sustainabledevelopment/</ext-link>.</comment>
</citation>
</ref>
<ref id="B35">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Shurson</surname>
<given-names>G. C.</given-names>
</name>
<name>
<surname>Salzer</surname>
<given-names>T. M.</given-names>
</name>
<name>
<surname>Koehler</surname>
<given-names>D. D.</given-names>
</name>
<name>
<surname>Whitney</surname>
<given-names>M. H.</given-names>
</name>
</person-group> (<year>2011</year>). <article-title>Effect of metal specific amino acid complexes and inorganic trace minerals on vitamin stability in premixes</article-title>. <source>Animal Feed Sci. Technol.</source> <volume>163</volume> (<issue>2&#x2013;4</issue>), <fpage>200</fpage>&#x2013;<lpage>206</lpage>. <pub-id pub-id-type="doi">10.1016/j.anifeedsci.2010.11.001</pub-id>
</citation>
</ref>
<ref id="B36">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Soares</surname>
<given-names>S.</given-names>
</name>
<name>
<surname>Donati</surname>
<given-names>G. L.</given-names>
</name>
<name>
<surname>Rocha</surname>
<given-names>F. R. P.</given-names>
</name>
</person-group> (<year>2022</year>). <article-title>Digital-image photometry with multi-energy calibration</article-title>. <source>Microchem. J.</source> <volume>182</volume> (<issue>November</issue>), <fpage>107938</fpage>. <pub-id pub-id-type="doi">10.1016/j.microc.2022.107938</pub-id>
</citation>
</ref>
<ref id="B37">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sol&#xe0;-Oriol</surname>
<given-names>D.</given-names>
</name>
<name>
<surname>Gasa</surname>
<given-names>J.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>Feeding strategies in pig production: sows and their piglets</article-title>. <source>Animal Feed Sci. Technol.</source> <volume>233</volume> (<issue>November</issue>), <fpage>34</fpage>&#x2013;<lpage>52</lpage>. <pub-id pub-id-type="doi">10.1016/j.anifeedsci.2016.07.018</pub-id>
</citation>
</ref>
<ref id="B38">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Spears</surname>
<given-names>J. W.</given-names>
</name>
<name>
<surname>Weiss</surname>
<given-names>W. P.</given-names>
</name>
</person-group> (<year>2008</year>). <article-title>Role of antioxidants and trace elements in health and immunity of transition dairy cows</article-title>. <source>Veterinary J.</source> <volume>176</volume> (<issue>1</issue>), <fpage>70</fpage>&#x2013;<lpage>76</lpage>. <pub-id pub-id-type="doi">10.1016/j.tvjl.2007.12.015</pub-id>
</citation>
</ref>
<ref id="B39">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Vieira</surname>
<given-names>A. L.</given-names>
</name>
<name>
<surname>Gon&#xe7;alves</surname>
<given-names>D. A.</given-names>
</name>
<name>
<surname>Virgilio</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Ferreira</surname>
<given-names>E. C.</given-names>
</name>
<name>
<surname>Jones</surname>
<given-names>B. T.</given-names>
</name>
<name>
<surname>Donati</surname>
<given-names>G. L.</given-names>
</name>
<etal/>
</person-group> (<year>2019</year>). <article-title>Multi-energy calibration for the determination of non-metals by high-resolution continuum source molecular absorption spectrometry</article-title>. <source>J. Anal. Atomic Spectrom.</source> <volume>34</volume> (<issue>5</issue>), <fpage>972</fpage>&#x2013;<lpage>978</lpage>. <pub-id pub-id-type="doi">10.1039/C9JA00006B</pub-id>
</citation>
</ref>
<ref id="B40">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Virgilio</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Gon&#xe7;alves</surname>
<given-names>D. A.</given-names>
</name>
<name>
<surname>McSweeney</surname>
<given-names>T.</given-names>
</name>
<name>
<surname>Gomes Neto</surname>
<given-names>J. A.</given-names>
</name>
<name>
<surname>N&#xf3;brega</surname>
<given-names>J. A.</given-names>
</name>
<name>
<surname>Donati</surname>
<given-names>G. L.</given-names>
</name>
</person-group> (<year>2017</year>). <article-title>Multi-energy calibration applied to atomic spectrometry</article-title>. <source>Anal. Chim. Acta</source> <volume>982</volume> (<issue>August</issue>), <fpage>31</fpage>&#x2013;<lpage>36</lpage>. <pub-id pub-id-type="doi">10.1016/j.aca.2017.06.040</pub-id>
</citation>
</ref>
<ref id="B41">
<citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Virgilio</surname>
<given-names>A.</given-names>
</name>
<name>
<surname>Silva</surname>
<given-names>A. B. S.</given-names>
</name>
<name>
<surname>Nogueira</surname>
<given-names>A. R. A.</given-names>
</name>
<name>
<surname>N&#xf3;brega</surname>
<given-names>J. A.</given-names>
</name>
<name>
<surname>Donati</surname>
<given-names>G. L.</given-names>
</name>
</person-group> (<year>2020</year>). <article-title>Calculating limits of detection and defining working ranges for multi-signal calibration methods</article-title>. <source>J. Anal. Atomic Spectrom.</source> <volume>35</volume> (<issue>8</issue>), <fpage>1614</fpage>&#x2013;<lpage>1620</lpage>. <pub-id pub-id-type="doi">10.1039/D0JA00212G</pub-id>
</citation>
</ref>
</ref-list>
</back>
</article>